C. Joram1 Demonstrating the AX-PET concept with digital Silicon PMs Cagliari, 6 October 2011 In collaboration with Philips Corporate Technologies The DSiPM.

Slides:



Advertisements
Similar presentations
New developments of Silicon Photomultipliers (for PET systems)
Advertisements

SiPM Interconnections to 3D electronics Jelena Ninkovic Max-Planck-Institute for Physics, Munich, Germany SiMPs basics Why do we need 3D interconnections.
Specific requirements for analog electronics of a high counting rate TRD Vasile Catanescu NIHAM - Bucharest CBM 10th Collaboration Meeting Sept 25 – 28,
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
Using the EUDET pixel telescope for resolution studies on silicon strip sensors with fine pitch Thomas Bergauer for the SiLC R&D collaboration 21. May.
20 Feb 2002Readout electronics1 Status of the readout design Paul Dauncey Imperial College Outline: Basic concept Features of proposal VFE interface issues.
Silicon Photomultiplier Readout Electronics for the GlueX Tagger Microscope Hall D Electronics Meeting, Newport News, Oct , 2007 Richard Jones, Igor.
17 May 2007LCWS analysis1 LCWS physics analysis work Paul Dauncey.
Trigger-less and reconfigurable data acquisition system for J-PET
A High-speed Adaptively-biased Current- to-current Front-end for SSPM Arrays Bob Zheng, Jean-Pierre Walder, Henrik von der Lippe, William Moses, Martin.
Low Cost TDC Using FPGA Logic Cell Delay Jinyuan Wu, Z. Shi For CKM Collaboration Jan
Introduction on SiPM devices
Photon detection Visible or near-visible wavelengths
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Second generation Front-end chip for H-Cal SiPM readout : SPIROC DESY Hamburg – le 13 février 2007 M. Bouchel, F. Dulucq, J. Fleury, C. de La Taille, G.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
MR (7/7/05) T2K electronics Beam structure ~ 8 (9?) bunches / spill bunch width ~ 60 nsec bunch separation ~ 600 nsec spill duration ~ 5  sec Time between.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
VC Feb 2010Slide 1 EMR Construction Status o General Design o Electronics o Cosmics test Jean-Sebastien Graulich, Geneva.
K.C.RAVINDRAN,GRAPES-3 EXPERIMENT,OOTY 1 Development of fast electronics for the GRAPES-3 experiment at Ooty K.C. RAVINDRAN On Behalf of GRAPES-3 Collaboration.
1 Digital Active Pixel Array (DAPA) for Vertex and Tracking Silicon Systems PROJECT G.Bashindzhagyan 1, N.Korotkova 1, R.Roeder 2, Chr.Schmidt 3, N.Sinev.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
CMS ECAL End Cap Meeting CERN 18 Oct to 22 Oct ECAL End Cap High Voltage and Fibre Optic Monitoring Systems Progress. Progress on High Voltage and.
COMPET Electronics and Readout
Planar Edgeless Silicon Detectors for the TOTEM Experiment 1.E-09 1.E-06 1.E /T, 1e3/K Current, A (294K) (256K)(227K)(204K) Gennaro Ruggiero,
AMS HVCMOS status Raimon Casanova Mohr 14/05/2015.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Sensor testing and validation plans for Phase-1 and Ultimate IPHC_HFT 06/15/ LG1.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
SPIROC update Felix Sefkow Most slides from Ludovic Raux HCAL main meeting April 18, 2007.
Gain stability and the LYSO beam radiation monitor measurements
Prague, Marcel Trimpl, Bonn University DEPFET-Readout Concept for TESLA based on Current Mode Signal Processing Markus Schumacher on behalf.
C. Joram1 The AX-PET project What was achieved ? What’s left to be done ? Are there ideas for a continuation ? Practicalities concerning the completion.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
11 October 2002Paul Dauncey - CDR Introduction1 CDR Introduction and Overview Paul Dauncey Imperial College London.
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
7 october 20111T. Schneider Test bench for digital sensor New Philips Digital Light Sensor Outer dimensions 32.6*32.6mm 2 8*8 pixel array Pixel pitch 4*4mm.
5 May 2006Paul Dauncey1 The ILC, CALICE and the ECAL Paul Dauncey Imperial College London.
Solar Power Charge Controller. Solar Power Charge Controller Introduction  A charge controller, or charge regulator is basically.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Hybrid CMOS strip detectors J. Dopke for the ATLAS strip CMOS group UK community meeting on CMOS sensors for particle tracking , Cosenors House,
C.Beigbeder, D.Breton, M.El Berni, J.Maalmi, V.Tocut – LAL/In2p3/CNRS L.Leterrier, S. Drouet - LPC/In2p3/CNRS P. Vallerand - GANIL/CNRS/CEA SuperB -Collaboration.
Pixel Sensors for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
Clear Performance and Demonstration of a novel Clear Concept for DEPFET Active Pixel Sensors Stefan Rummel Max-Planck-Institut für Physik – Halbleiterlabor.
Silicon Photomultiplier (SiPM) Readout Application Specific Integrated Chip (ASIC) for Timing Huangshan Chen.
ASICs1 Drain Current Digitizer Chip (DCD) Status and Future Plans.
IFR Detector R&D status
IFR Detector R&D status
Matteo VIGNETTI *a (WP2 ESR PhD Student)
LHC1 & COOP September 1995 Report
Results achieved so far to improve the RPC rate capability
KRB proposal (Read Board of Kyiv group)
K. Sedlak, A. Stoykov, R. Scheuermann
Planar Edgeless Silicon Detectors for the TOTEM Experiment
Next generation 3D digital SiPM for precise timing resolution
Status of n-XYTER read-out chain at GSI
X. Zhu1, 3, Z. Deng1, 3, A. Lan2, X. Sun2, Y. Liu1, 3, Y. Shao2
BESIII EMC electronics
MSP432™ MCUs Training Part 6: Analog Peripherals
The LHCb Front-end Electronics System Status and Future Development
On behalf of the CEPC MOST2 Vertex detector design team
Presentation transcript:

C. Joram1 Demonstrating the AX-PET concept with digital Silicon PMs Cagliari, 6 October 2011 In collaboration with Philips Corporate Technologies The DSiPM principle A possible AX-PET test set-up Practicalities (contractual, financial, schedule) Most of the material shown in this talk is from T. Frach (Philips), talk at NDIP 2011, Lyon, and proceedings articles of the Philips group from recent IEEE NSS-MIC conferences.

C. Joram2

3 Different from analog SiPMs: Upon the detection of a photon, the avalanche is actively quenched using a dedicated transistor, and a different transistor is used to quickly recharge the diode back to its sensitive state.

C. Joram4 Each cell provides a fast asynchronous trigger signal and a slower synchronous data output signal. TDC measurement range : ns.

C. Joram5 Philips terminology: 1 single cell = SPAD (30 x 50  m 2 ) 1 pixel 1 chip a 4-pixel chip

C. Joram6 backside Test card (not part of kit)  all pixels are individually readable, but there are only 16 trigger logics. DLS  the 4x4 chips are mounted on a PCB. Every chip has 2x2 = 4 pixels. Currently the largest device... and of main interest for AX-PET

C. Joram7 Quite well adapted for readout of crystals (1000 detected photons).  No sizable saturation to be expected.

C. Joram8 Power consumption: 600 mW for the whole array.

C. Joram9  < 1  s Expect readout rate up to O(1 MHz) trigger

C. Joram10 Depending on the combinations of And/Or, the trigger level of a pixel can be 1, ≥ 2, ≥ 3, ≥ 4 photons Except for the first photon trigger level, any diode breakdown is assumed to be a dark count and is automatically reset if it does not lead to a trigger within 10 to 15 ns from its occurrence. This embedded refresh logic prevents dark counts from accumulating and, eventually, reaching the trigger threshold. System can also be triggered externally. Details to be clarified! Pixel is subdivided in 4 sub-pixels (with 1600 cells each)

C. Joram11 Triggering on coincidences of sub-pixels is a statistical process ! The 2 nd photon can also come from the same sub-pixel as the 1 st  no coincidence ! The total trigger generation probability for the number of detected photons as a function of the selected trigger level. The trigger generation probability for the n-th photon as a function of the selected trigger level. If you have 2 photons, the probability that they come from the same sub-pixel is ¼.  The ≥2 photon trigger probability is therefore 1 - ¾ = 75%. Watch out for AX-PET WLS signals. The WLS cross-section is small compared to the pixel size. We may not touch all sub-pixels. The signal amplitude can be small (~10 ph).

C. Joram12 T. Frach, 2009 IEEE Nuclear Science Symposium Conference Record A second, higher-level energy-like threshold is implemented in a similar way to distinguish valid events from dark counts. The pixel is subdivided into 64 mutually exclusive regions to allow the adjustment of the validation threshold to up to the minimum of 64 photons. The validation signal is tested at a user-defined time after the trigger has been detected and a fast pixel reset is issued in case of a dark count event to minimize sensor dead time. The validation logic

C. Joram13 T. Frach, 2009 IEEE Nuclear Science Symposium Conference Record Collection and Readout If the validation threshold is reached, the state machine changes to the state COLLECT. The collection time is user-defined between 5 and 2560 ns. The photons impinging on the sensor are detected and stored in the cells for later readout. After the expiration of the COLLECT timer, the pixel state machine goes to the state READOUT. Each line of the sensor is selected separately and the number of photons detected in the line is added to the photon accumulator. While reading out one line, the preceding line is recharged to avoid large current surges during the global reset of the pixel. Finally, the pixel controller goes to the RESET state for global pixel recharge and TDC reset, and then back to the READY state.

C. Joram14

C. Joram15

C. Joram16 DLD8K (783  m 2 pixel size)

C. Joram17 (2954  m 2 pixel size) My interpretations...  Expect ~280 cps per SPAD for the DLS chip (cell size 1500  m 2 ).  Deadtime per cell: 280 Hz · >20 ns = 5.6  s / s  negligible  Deadtime per pixel: 280 Hz · 6400 · 20 ns = 36 ms / s ~ 4%  still small.  Dark count rate per sub-pixel: 280 Hz · 1600 = 450 kHz  Dark count rate per pixel at 4 photon level: (450 kHz) 4 · (10 ns) 3 = 0.04 Hz

C. Joram18

C. Joram19 Digital SiPM has a number of attractive features which makes it interesting for a concept like AX-PET -The digital approach is ‘in principle’ simpler than the analog one. It avoids the conversion of number of fired cells to charge. -No need of analog readout electronics -High intrinsic time precision -Lower sensitivity to bias voltage and temperature variations However, the DSiPM requires a dedicated readout. One has, at least initially, to use the readout which Philips provides. Is this a serious limitation? The performance in terms of  E and  t demonstrated with LYSO crystals are comparable to analog systems. Nota bene: The current DSiPM approach leads to an asynchronous PET device operated in time-stamped list mode. One records only single hits. Selection of energy (e.g. 511 keV in a crystal matrix) and coincidences must be made at a later stage (for the time being offline). For a full system, the data rates become large and it will require a more detailed study if/how they can be handled. Summary (part 1) and some conclusions

C. Joram20 A test set-up is proposed -To demonstrate the AX-PET basic features with digital readout -Energy resolution with long LYSO crystals (3x3x100 or 3x3x150) -Axial resolution from WLS strip arrays -In addition: time resolution in view of TOF-PET capability This test set-up will be completely independent of the available AX-PET set-up. Sketch by Philips ACAD drawing 4 LYSO Crystals (3x3 mm 2 ) 2 WLS strips (0.9 mm) These quadrants correspond only to a fourth of the DSiPM surface

C. Joram21 Crystals fit well on pixels, allowing for am active edge of ≥ 0.1 mm around.

C. Joram22

C. Joram23 Configuration for standard AX-PET measurements Set-up to measure time resolution. Use mean time between two DSiPMs or correct time by axial position. = 0.5·(T1 + T2) Tagged Na-22 source

C. Joram24 Optional: coincidence set-ups

C. Joram25 Practicalities DSiPM have a very thin entrance window (100  m glass). In the interest of reusing the DSiPM, avoid glue. Use optical grease instead.  Thomas will propose some mechanics which holds all components in place without glue. Set-up will then be operated in a dark box. An offer has been requested from Saint Gobain for 5 LYSO crystals 3 x 3 x LYSO crystals 3 x 3 x 150 Philips offers an evaluation kit, consisting of 3 (or 4) sensor arrays DLS FPGA based readout unit, capable of handling up to 4 sensor arrays Power supplies Laptop Installation, training and user support The user buys the right to evaluate the kit. In principle the kit has to be given back to Philips at the end of a 3-years evaluation period.

C. Joram26 The kit is not cheap (~ ). Discussions were held with potentially interested groups. The kit will probably be shared by 4 partners: ETH-Z, CERN-PH/DT, CERN- ATLAS, Tampere (not yet confirmed). ETH-Z and CERN-PH/DT will build the presented set-up and evaluate its performance (until summer 2012) Tampere is interested in building a prototype of a small special PET scanner (until end of 2012) CERN-ATLAS is interested in the readout of scintillating fibres (2013) Philips indicated a 25% discount on the normal prize as in-kind contribution to the project. If demonstration is successful, further steps could lead to the development by Philips of a scalable/integratable PET module based on the Axial Concept.