SCIPP Santa Cruz Institute for Particle Physics

Slides:



Advertisements
Similar presentations
Semiconductor detectors
Advertisements

Radiation damage in silicon sensors
Epitaxial Silicon Detectors for Particle Tracking Overview on Radiation Tolerance at Extreme Hadron Fluence G. Lindström (a), E. Fretwurst (a), F. Hönniger.
The ATLAS Pixel Detector
ATLAS SCT Endcap Detector Modules Lutz Feld University of Freiburg for the ATLAS SCT Collaboration Vertex m.
Evaluation of the Radiation Tolerance of SiGe Heterojunction Bipolar Transistors Under Gamma Exposure J. Metcalfe, D.E. Dorfan, A. A. Grillo, A. Jones,
E.N. Spencer SCIPP-UCSC 18 May 2006 FEE Perugia Silicon Germanium BICMOS: Irradiation Resistance and Low Power Analog Applications 1 FEE2006 Workshop on.
Hartmut Sadrozinski US-ATLAS 9/22/03 Detector Technologies for an All-Semiconductor Tracker at the sLHC Hartmut F.W. Sadrozinski SCIPP, UC Santa Cruz.
LHC SPS PS. 46 m 22 m A Toroidal LHC ApparatuS - ATLAS As large as the CERN main bulding.
Department of Physics VERTEX 2002 – Hawaii, 3-7 Nov Outline: Introduction ISE simulation of non-irradiated and irradiated devices Non-homogeneous.
LHC Experiments at Liverpool E2V Visit – Nov 2005 Introduction Si Technology Upgrade/Maintenance Summary.
For high fluence, good S/N ratio thanks to: Single strip leakage current I leak  95nA at T  -5C Interstrip capacitance  3pF SVX4 chip 10 modules fully.
Radiation Effects in Microelectronics EE-698a Course Seminar by Aashish Agrawal.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
The SLHC and the Challenges of the CMS Upgrade William Ferguson First year seminar March 2 nd
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
A Serializer ASIC for High Speed Data Transmission in Cryogenic and HiRel Environment Tiankuan Liu On behalf of the ATLAS Liquid Argon Calorimeter Group.
Hartmut Sadrozinski, SCIPP RD50 Sensor Meeting Trento, Feb. 28, Electronics Issues for sLHC Tracking Detectors Noise, Threshold Signal Signal/Threshold.
U.S. ATLAS Executive Meeting Upgrade R&D August 3, 2005Toronto, Canada A. Seiden UC Santa Cruz.
E.N. Spencer SCIPP-UCSC ATLAS 10-Nov-05 1 Electronics Issues, Frontend 1 (Strips that is, not Pixels) US-ATLAS Upgrade R&D Meeting UCSC 10-Nov-2005 A.A.
X-ray radiation damage of silicon strip detectors AGH University of Science and Technology Faculty of Physics and Applied Computer Science, Kraków, Poland.
CMOS technologies in the 100 nm range for rad-hard front-end electronics in future collider experiments V. Re a,c, L. Gaioni b,c, M. Manghisoni a,c, L.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Detectors and electronics for Super-LHC: IRRADIATION RESULTS Andrea Candelori INFN Sezione di Padova.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Online Radiation Dose Measurement System for ATLAS experiment I. Mandić a, representing ATLAS collaboration a Jožef Stefan Institute, Jamova 39, Ljubljana,
June 3rd, 2009Studies of Depletion Voltage Jessica Metcalfe University of New Mexico Capacitance Measurements and Depletion Voltage for Annealed Fz and.
Gunnar Lindstroem – University of HamburgHamburg workshop 24-Aug-061 Radiation Tolerance of Silicon Detectors The Challenge for Applications in Future.
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
Study of leakage current and effective dopant concentration in irradiated epi-Si detectors I. Dolenc, V. Cindro, G. Kramberger, I. Mandić, M. Mikuž Jožef.
Faster tracking in hadron collider experiments  The problem  The solution  Conclusions Hans Drevermann (CERN) Nikos Konstantinidis ( Santa Cruz)
Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure Jessica Metcalfe D.E.
Radiation Tests on IHP’s SiGe Technologies for the Front-End Detector Readout in the S-LHC M. Ullán, S. Díez, F. Campabadal, G. Pellegrini, M. Lozano CNM.
SLHC SG: ATLAS Pixel G. Darbo - INFN / Genova SLHC SG, July 2004 ATLAS Pixel at SLHC G. Darbo - INFN / Genova Talk overview: A table with different High.
Radiation Damage in Bipolar Transistors Caused by Thermal Neutrons I. Mandić, V. Cindro, G. Kramberger, E. S. Krištof, M. Mikuž, D. Vrtačnik Jožef Stefan.
A.A. Grillo SCIPP-UCSC ATLAS 19-Jul SiGe biCMOS for Next Gen Strip Readout Evaluation of SiGe biCMOS Technologies for Next Generation Strip Readout.
First Results from the Online Radiation Dose Monitoring System in ATLAS Experiment ______________________________________________________________________________________________________.
Evaluation of Two SiGe HBT Technologies for the ATLAS sLHC Upgrade Miguel Ullán & the SiGe Group.
Si-detector macroscopic damage parameters during irradiation from measurements of dark current evolution of with fluence Craig Buttar, University of Sheffield.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
Technology Overview or Challenges of Future High Energy Particle Detection Tomasz Hemperek
A.A. Grillo SCIPP-UCSC ATLAS 3-May Evaluation of SiGe Technology – Status Report US-ATLAS Upgrade Meeting Evaluation of SiGe Technology - Status.
G. Steinbrück, University of Hamburg, SLHC Workshop, Perugia, 3-4 April Epitaxial Silicon Detectors for Particle Tracking Overview on Radiation Tolerance.
p-on-n Strip Detectors: ATLAS & CMS
Gossip/GridPix – guidelines, facts, and questions for review Version 1: Norbert Version 2: Tatsuo Version 3: Werner.
LHCb Vertex Detector and Beetle Chip
Celso Figueiredo26/10/2015 Characterization and optimization of silicon sensors for intense radiation fields Traineeship project within the PH-DT-DD section.
The LHCb Vertex Locator Lars Eklund LHCb VELO Group of the LHCb Collaboration CERN (Geneva), EPFL (Lausanne), NIKHEF (Amsterdam), University of Glasgow,
Ideas for Super LHC tracking upgrades 3/11/04 Marc Weber We have been thinking and meeting to discuss SLHC tracking R&D for a while… Agenda  Introduction:
Fabiola Gianotti, 14/10/20031  s = 28 TeV upgrade L = upgrade “SLHC = Super-LHC” vs Question : do we want to consider also the energy upgrade option.
1 Updates on Punch-through Protection H. F.–W. Sadrozinski with C. Betancourt, A. Bielecki, Z. Butko, A. Deran, V. Fadeyev, S. Lindgren, C. Parker, N.
The BTeV Pixel Detector and Trigger System Simon Kwan Fermilab P.O. Box 500, Batavia, IL 60510, USA BEACH2002, June 29, 2002 Vancouver, Canada.
Ideas on MAPS design for ATLAS ITk. HV-MAPS challenges Fast signal Good signal over noise ratio (S/N). Radiation tolerance (various fluences) Resolution.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1, Marko Zavrtanik 1,
E.N. Spencer SCIPP-UCSC ATLAS 13-September-05 1 SiGe biCMOS for Next Gen Strip Readout 1 Evaluation of SiGe biCMOS Technologies for Next Generation Strip.
Progress on Radiation Hardness Tests on SiGe Technologies for S-LHC Miguel Ullán, F. Campabadal, S. Díez, C. Fleta, M. Lozano, G. Pellegrini, J. M. Rafí.
Tracking Upgrade R&D Meeting. Columbia University A. Seiden September 22, 2003.
Detector building Notes of our discussion
 Silicon Vertex Detector Upgrade for the Belle II Experiment
Charge sensitive amplifier
M. Manghisoni, L. Ratti, V. Re, V. Speziali, G. Traversi
Results achieved so far to improve the RPC rate capability
Sep th Hiroshima Xi’an Test-beam evaluation of newly developed n+-in-p planar pixel sensors aiming for use in high radiation environment.
Update on Annealing Studies for Severely Irradiated Silicon Detectors
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Radiation Damage Studies for Solid State Sensors Subject to Mrad Doses
Results from the first diode irradiation and status of bonding tests
HVCMOS Detectors – Overview
Grounding, Power Distribution
Presentation transcript:

SCIPP Santa Cruz Institute for Particle Physics Evaluation of the Radiation Tolerance of SiGe Heterojunction Bipolar Transistors Under 24GeV Proton Exposure J. Metcalfe, D.E. Dorfan, A. A. Grillo, M Rogers, H. F.-W. Sadrozinski, A. Seiden, E. Spencer, M. Wilder SCIPP, University of California Santa Cruz, 95064, USA A. Sutton,G. Prakash, J.D. Cressler Georgia Tech, Atlanta, GA 30332-0250, USA

Rad Tolerance of SiGe HBT J. Metcalfe SCIPP Why SiGe? Advantages of SiGe Bipolar Over CMOS for Silicon Strip Detectors A key element in the design of low noise, fast shaping, charge amplifiers is high transconductance in the first stage. With CMOS technologies, this requires relatively larger bias currents than with bipolar technologies. The changes that make SiGe Bipolar technology operate at 100 GHz for the wireless industry coincide with the features that enhance performance in high energy particle physics applications. Small feature size increases radiation tolerance. Extremely small base resistance (of order 10-100 W) affords low noise designs at very low bias currents. These design features are important for applications with: Large capacitive loads (e.g. 5-15 pF silicon strip detectors) Fast shaping times (e.g. accelerator experiments with beam crossing times of tens of nanoseconds in order to identify individual beam crossing events) 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Challenges for ATLAS Upgrade SCIPP Challenges for ATLAS Upgrade Inner Pixel Mid-Radius Short Strips Outer-Radius “SCT” Fluence [1014 neq/cm2] The LHC upgrade will increase the luminosity by a factor of 10! Fluences in the inner detector will reach as high as 1016 neq/cm2! The challenge is to find front-end electronics resistant to radiation damage that will also reduce power consumption with acceptable noise. Our efforts focus on fluences achieved in the mid to outer radii of silicon strip detectors. 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Rad Tolerance of SiGe HBT J. Metcalfe SCIPP Silicon Germanium (SiGe) Heterojunction Bipolar Transistors (HBTs) (First Generation IBM Process) Origin of radiation tolerance: Small active volume of the transistor Thin emitter-base spacer oxide (weakest spot) Irradiation Procedure: Devices were sent to CERN and exposed to a 24GeV proton source with the highest fluence taking 5 days to accumulate. The leads were grounded during irradiation --> worst case scenario. The transistors were annealed to improve performance. Special thanks to the RD50 collaboration, especially, Michael Moll and Maurice Glaser. Device Sizes: 0.5x1 mm2 0.5x2.5 mm2 0.5x10 mm2 0.5x20 mm2 4x5 mm2 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

The Effects of Proton Irradiation SCIPP The Effects of Proton Irradiation Pre-rad 1.15 x 1014 4.15 x 1013 3.50 x 1014 1.34 x 1015 3.58 x 1015 1.05 x 1016 ATLAS Upgrade Outer Radius Mid Radius Inner Radius 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Radiation Damage Mechanisms SCIPP Radiation Damage Mechanisms Forward Gummel Plot for 0.5x2.5 mm2 Ic,Ib vs. Vbe Pre-rad and After 1x1015 p/cm2 & Anneal Steps Radiation damage increases base current causing the gain of the device to degrade. Gain=Ic/Ib (collector current/base current) Collector current remains the same Ic , Ib [A] Base current increases after irradiation Vbe [V] Ionization Damage (in the spacer oxide layers) The charged nature of the particle creates oxide trapped charges and interface states in the emitter-base spacer increasing the base current. Displacement Damage (in the oxide and bulk) The incident mass of the particle knocks out atoms in the lattice structure shortening hole lifetime, which is inversely proportional to the base current. 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Annealing Effects SCIPP Current Gain, b Ic [A] Annealing of 0.5x2.5 mm2: Current Gain, b, vs. Ic Pre-rad and After 1x1015 p/cm2 & Anneal Steps Before Irradiation After Irradiation After Irradiation & Full Annealing We studied the effects of annealing. The performance improves appreciably. In the case above, the gain is now over 50 at 10mA entering into the region where an efficient chip design may be implemented with this technology. The annealing effects are expected to be sensitive to the biasing conditions. We plan to study this in the future. 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Initial Results: SCIPP Current Gain, b Current Gain, b, vs. Ic for 0.5x10 mm2 Pre-rad and for All Fluences Including Full Annealing Ic [A] Before Irradiation Increasing Fluence Lowest Fluence Current Gain, b Highest Fluence After irradiation, the gain decreases as the fluence level increases. Performance is still very good at a fluence level of 1x1015 p/cm2. A typical Ic for transistor operation might be around 10 mA where a b of around 50 is required for a chip design. At 3x1015, operation is still acceptable for certain applications. 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Universality of Results: SCIPP Universality of Results: D(1/b) Post-rad & Anneal to Pre-rad @ Jc=10mA Ratio of Current Gain, b Post-rad & Anneal to Pre-rad @ Jc=10 mA 1/b(final) - 1/b(initial) Ratio b(final)/b(initial) Proton Fluence [p/cm2] Proton Fluence [p/cm2] Universal behavior is independent of transistor geometry when compared at the same current density Jc. For a given current density D(1/b) scales linearly with the log of the fluence. This precise relation allows the gain after irradiation to be predicted for other SiGe HBTs. Note there is little dependence on the initial gain value. 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Feasibility for ATLAS Inner Detector Upgrade SCIPP Feasibility for ATLAS Inner Detector Upgrade Qualifications for a good transistor: A gain of 50 is a good figure of merit for a transistor to use in a front-end circuit design. Low currents translate into increased power savings. At 1.34x1015 closer to the mid radius (20 cm), where short (3 cm) silicon strip detectors with capacitance around 5pF will be used, the collector current Ic is still good for a front transistor, which requires a larger current while minimizing noise. We expect better results from 3rd generation IBM SiGe HBTs. At 3.5x1014 in the outer region (60 cm), where long (10 cm) silicon strip detectors with capacitances around 15pF will be used, the collector current Ic is low enough for substantial power savings over CMOS! 10/26 Rad Tolerance of SiGe HBT J. Metcalfe

Rad Tolerance of SiGe HBT J. Metcalfe SCIPP Conclusions We extended the radiation testing of SiGe Bipolar transistors by a factor 100 in fluence thanks to the RD50 radiation program. The 5HP technology we examined is far superior to that used for the current ATLAS silicon strip detectors. The 5HP demonstrates utility--power savings and low noise--for the entire analog front-end in the outer region and for the front transistor in the mid radius of ATLAS Upgrade. Future generations (smaller sizes) of SiGe HBTs show huge potential for power savings with low noise at extreme radiation levels. Investigation is currently under way to determine the benefits of the next generations of SiGe HBTs in future collider experiments (i.e. sLHC). 10/26 Rad Tolerance of SiGe HBT J. Metcalfe