Ultramicrotomy Sections: 50-70 nm thick 0.1-0.5 mm square Resin good morphology Cryo good immuno-labelling Knives Glass Diamond

Slides:



Advertisements
Similar presentations
Advances in Bioscience Education Summer Workshop Fluorescence and Electron Microscopy June , 2007 Biological Electron Microscope Facility Pacific.
Advertisements

IFFAT FATIMA UOG. ELECTRON MICROSCOPE Contents History LM Vs EM Electron microscope Principle Types of EM Application & importance.
Microtoming with Leica UC-6. Why? Basic method to prepare polymeric and biology TEM samples Has also been used in other sample preparation. –Can reduce.
CHAPTER 3 DECALCIFICATION Learning Objectives:
Immunolocalization for EM Using immunoglobulin molecules as tags for select proteins and carbohydrates. Visualized by using colloidal gold or enzyme reactions.
Tissue Submission All tissue submitted to the core should be accurately described on both form and vial. We can process, embedding and sectioning without.
Immunolabeling of Cells and Transmission Electron Microscopy Ike Miguel June 30, 2006 ABE Workshop 2006.
Immunolabeling and Transmission Electron Microscopy.
PREPARATION OF HISTOLOGICAL SPECIMENS
Tissue Processing All lectures will emphasize information relevant to labs.
Sectioning or Microtomy
Electron Microscope.
Electron Microscope. Light vs EM Which is which? What are the main differences?
Electron Microscopy.
Transmission Electron Microscopy
CYTOLOGY BY Dr. TAREK ATIA Histology and Cell Biology.
Measurement & Microscopes
Immuno-labelling for TEM cryo-chambertemp. control liquid nitrogen sectioning control Sample processing 1.Fix 4% PFA 2.Wash/Quench 3.Harvest cells/tissue.
Histology 1.2.: Immunohistochemistry. Immunohistochemistry uses the principle of immunity: During development the immune system recognizes foreignDuring.
Histology Histology is the study of the tissues of the body and how these tissues are arranged to constitute organs Literally, histology means tissue or.
Histology and Embryology
Preparation Of Carrot Explants 1.) Wash carrot taproots in warm, soapy water. Break or cut carrot taproots into pieces 7 cm or less in length. Be careful.
Standard Preparation Tissue TEM SEM Chem. Fixation Cryo Fixation Chem.
The scale of things د. عمر عبد القادر. Detection light microscopy: photons interact with the specimen electron microscopy: electrons interact with the.
组织胚胎学课件 七年制英文医学班专用 中国医科大学 基础医学院 组胚 — 英文教学组. Chapter 1 Introduction.
Histology Techniques CLS 322
Procedures Fixation Tissues must be immersed in fixative immediately after removal from the body . 10% Neutral Buffered Formalin is the routine fixative.
Lecturer of Biochemistry
Light Microscope. Light Microscope Light Microscope The light microscope depends on light passing through an object in order for it to be seen. The result.
Starter: Microscopes Which image is from the light microsope? How do you know?
Microscopy as an analytical tool Dr Imran. Wavelength and resolution Resolution (r) = λ / (2NA) R= resolution λ = wavelength of light used for imaging.
SELECTION OF THE TISSUE BLOCK
Lab 2: Tissue Processing
Introduction.
Grids Cleaning_ A very important step for a successful data collection from cryo electron microscopy Zongli Li Oct. 11, 2004.
实验十四 紫外线灭菌  一、实验背景及目的:  灭菌是一种杀灭微生物的措施。紫外线灭菌 是物理灭菌因素之一。  1. 了解紫外线灭菌的原理;  2. 学习、掌握紫外线灭菌的方法。 版权所有 未经作者同意 请勿使用.
 machines that cut extremely thin sections from a sample for applications in histology or pathology  use special metal, glass, or diamond blades, depending.
PRACTICAL -2 TISSUE PROCESSING 1 Dr.Nessrin Alabdallat.
Professor KI-JONG RHEE Teaching assistant MIN HO LEE.
Preparation of Plant tissues for histological study
MICROSCOPICAL TECHNIQUES PREPARATIONS. Preparations by hand samples into the stem of elder (Sambucus nigra), by a blade generally cross sections fast,
The reading is 7.38 mm. The reading is 7.72 mm.
Outline History(TEM) Background Components Specimen Preparation Imaging method Contrast formation Modifications STEM References.
Electron Microscopes. We will be discussing The history of the electron microscope Two major difference between the electron microscope and light microscope.
Click on image for SEM images electron microscope Principles and limitations of scanning and transmission EM Difference between magnification and.
Immunolocalization for EM Using immunoglobulin molecules as tags for select proteins and carbohydrates. Visualized by using colloidal gold or enzyme reactions.
10 mm is the same as... 1 cm. 20 mm is the same as... 2 cm.
Light Microscope Terms and Practices.
Introduction to Histology Light and Electron Microscopes
Go to this link and complete questions 1 +2 only!
Standard Operating Procedure Reichert-Jung Ultramicrotome
Histology introduction
Protocol of preparing Adhesion Assay imaging
THE LIGHT MICROSCOPE AND THE ELECTRON MICROSCOPE
College of Education Biology Dept.
INTRODUCTION TO HISTOLOGY
Starter: Microscopes Which image is from the light microsope? How do you know?
THE LIGHT MICROSCOPE AND THE ELECTRON MICROSCOPE
Jominy test for hardenability calculations
Methods and Materials: Microscopic & Drug Distribution Studies
Supplemental Figure 1 HA-GIPR WT Untransfected HA-C46S HA-G198C
Laboratory Technique {Histological Technique}
General Principles of Tissue Preparation and Staining
Concept: Cell Biology tools - microscopy & chemistry
Methods of Sample Preparation
Histology and Embryology
How to look at bacteria &
THE LIGHT MICROSCOPE AND THE ELECTRON MICROSCOPE
L2036H1 grid6 First cut x x x x x x x x x x x x x x x x x x x x x x x
Presentation transcript:

Ultramicrotomy Sections: nm thick mm square Resin good morphology Cryo good immuno-labelling Knives Glass Diamond 3mm diamond

Ultramicrotomy Sections: nm thick mm square Resin good morphology Cryo good immuno-labelling Knives Glass Diamond specimen knife speed/thickness controller

Processing for resin sectioning Protocol: 1.Fix (4% paraformaldehyde, 2.5% glutaradehyde)4hrs-o/n 2.Wash and quench (50mM glycine)5 min 3.1% OsO 4 1.5hrs 4.5% alcoholic uranyl acetate1.5hrs 5.Dehydrate (50%, 70%, 90%, 100% ethanol, 100% acetone) 1.5hrs 6.Infiltrate (araldite resin; 30:70, 70:30, 100%)4 hrs 7.Polymerise 60ºCo/n Sample: eg. cells in 1 x 6cm dish. Final pellet ≤1mm 3

Processing for resin sectioning 1. Trim block (≤0.3mm 2 face) 3. Collect sections on EM grid 2. Sectioning 50-70nm (silver/gold colour)