EUCARD WP12 DESY 2015 Slide 1 EuCARD-2 is co-funded by the partners and the European Commission under Capacities 7th Framework Programme, Grant Agreement.

Slides:



Advertisements
Similar presentations
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
Advertisements

Progress of the sub-harmonic bunching system (i.e. upgrading progress of BEPCII present bunching system) Pei Shilun for the SHBS team Accelerator center,
Synchronization system for CLIC crab cavities Amos Dexter, Ben Woolley, Igor Syratchev. LCWS12, UTA October 2012.
Particle Accelerator Engineering, London, October 2014 Phase Synchronisation Systems Dr A.C. Dexter Overview Accelerator Synchronisation Examples Categories.
High gradient test results from X-BOX1 Ben Woolley XBOX Team CERN, Switzerland February 2014.
1 X-band Single Cell and T18_SLAC_2 Test Results at NLCTA Faya Wang Chris Adolphsen Jul
Design of Standing-Wave Accelerator Structure
RF Synchronisation Issues
Stefan Simrock 3 rd LC School, Oak Brook, IL, USA, 2008, Radio Frequency Systems 1 Timing and Synchronization S. Simrock and Axel Winter DESY, Hamburg,
R. Corsini, CLIC Project Meeting - 24 th May 2013 CTF3 1 CTF3: Highlights of the 1 st run R. Corsini for the CTF3 Team 1.
Alessandro Cappelletti for CTF3 collaboration 5 th May 2010 RESULTS OF BEAM BASED RF POWER PRODUCTION IN CTF3.
LLRF Phase Reference System The LCLS linac is broken down into 4 separate linac sections. The LCLS injector will reside in an off axis tunnel at the end.
1 Timing and RF Distribution NLC -> ILC Josef Frisch.
SLHC-PP – WP7 Critical Components for Injector Upgrade Plasma Generator – CERN, DESY, STFC-RAL Linac4 2MHz RF source Thermal Modeling Gas Measurement and.
Andrew Moss ASTeC 7 th December 2011 MICE RF System.
ATF2 Q-BPM System 19 Dec Fifth ATF2 Project Meeting J. May, D. McCormick, T. Smith (SLAC) S. Boogert (RH) B. Meller (Cornell) Y. Honda (KEK)
HIGH RF POWER TESTING FOR THE CLIC PETS International Workshop on Linear Colliders 20 th October 2010 Alessandro Cappelletti for the CLIC team with.
RF Distribution Alternatives R.A.Yogi & FREIA group Uppsala University.
Test Facilities and Component Developments Sami Tantawi SLAC May 15, 2008.
Xbox-3 LLRF Ben Woolley Stephane Rey & Heiko Damerau.
Clustered Surface RF Production Scheme Chris Adolphsen Chris Nantista SLAC.
Solid State Microwave Oscillators Convert dc energy to microwave signals Can be used as generators in all communication systems, radars, electronic counter.
Andrew Moss ASTeC CM32 9t h February 2012 RAL MICE RF System.
IWLC10 CLIC Crab Cavities Amos Dexter (on behalf of the LC Crab System Collaborations) CERN 20 th October 2010.
Anders Sunesson RF Group ESS Accelerator Division
Frank Ludwig, DESY Content : 1 Stability requirements for phase and amplitude for the XFEL 2 Next LLRF system for optimized detector operation 3 Limitations.
Modulator and overmoded RF components status for the 12GHz Test Stand at CERN - RF meeting – 17/03/2010.
XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser 1 Frank Ludwig, DESY XFEL-LLRF-ATCA Meeting, 3-4 December 2007 Downconverter Cavity Field.
LLRF for EUCARD Crab Cavities Graeme Burt (on behalf of Amos Dexter) Paris May 2011.
CLARA Gun Cavity Optimisation NVEC 05/06/2014 P. Goudket G. Burt, L. Cowie, J. McKenzie, B. Militsyn.
CLIC crab cavity design Praveen Ambattu 24/08/2011.
Measurements of the X-ray/pump laser pulse timing Valery Dolgashev, David Fritz, Yiping Feng, Gordon Bowden SLAC 48th ICFA Advanced Beam Dynamics Workshop.
EnEfficient RF Sources Workshop. June 2014 I. Syratchev X-band high RF power testing activity at CERN I.Syratchev.
Femtosecond phase measurement Alexandra Andersson CLIC Beam Instrumentation workshop.
HIE-ISOLDE diagnostic boxes Esteban D. Cantero CERN BE-BI-PM HIE-ISOLDE meeting for BE/BI 28 March 2014 The research leading to these results has received.
BEPC II TIMING SYSTEM EPICS Seminar Presented by Ma zhenhan IHEP 20.August 2002.
Status of high gradient experiments at Nextef Kazue Yokoyama, Toshiyasu Higo, Yasuo Higashi, Shuji Matsumoto, Shigeki Fukuda Accelerator Laboratory, KEK.
Peak temperature rise specification for accelerating structures: a review and discussion CLIC meeting
High Power RF Measurements Ben Woolley, Amos Dexter, Igor Syratchev. Jan Kovermann, Joseph Tagg HG2013, Trieste June 2013.
CLIC-UK Programme Status Philip Burrows John Adams Institute Oxford University 1.
High precision phase monitoring Alexandra Andersson, CERN Jonathan Sladen, CERN This work is supported by the Commission of the European Communities under.
High gradient test results from X-BOX1 Ben Woolley XBOX Team CERN, Switzerland December 2013.
Instrumentation at ATF / TTF Accelerator Test Facility (KEK) Tesla Test Facility – FLASH (DESY) ESA / LCLS (SLAC) Marc Ross, SLAC.
Accelerating structure prototypes for 2011 (proposal) A.Grudiev 6/07/11.
FLASH RF gun developments. Sven Pfeiffer for the LLRF team FEL Seminar Hamburg,
C/S band RF deflector for post interaction longitudinal phase space optimization (D. Alesini)
ALBA RF Systems Francis Perez.
RF Commissioning D. Jacquet and M. Gruwé. November 8 th 2007D. Jacquet and M. Gruwé2 RF systems in a few words (I) A transverse dampers system ACCELERATING.
Status of Vertical Test Stand at RRCAT P Shrivastava, P Mohania,D.Baxy, Vikas Rajput S C Joshi, S Raghavendra,S K Suhane RRCAT, Indore November 26, 2012.
CarterFest 14 th July 2010 Stabilised Magnetrons Presentation to mark Professor Richard Carter’s contributions to Vacuum Electronics Delivered by Amos.
High Power Crab Cavity Testing Ben Woolley HG2016 Argonne National Lab. 8 th June 2016.
EUCARD WP10.3 Daresbury April 2010 LLRF for EUCARD Crab Cavities Amos Dexter and Imran Tahir Daresbury 7 th April 2010.
Areal RF Station A. Vardanyan
Communication 40 GHz Anurag Nigam.
CLIC Crab Synchronisation
Development of X-band 50MW klystron in BVERI
CLIC Crab Synchronisation
An X-band system for phase space linearisation on CLARA
Ben Woolley CLIC Workshop 2016 (LCWS16) CERN, Switzerland 18/01/2016
RF Synchronisation Issues
12 GHz High Power RF components requirements for CEA activities
Developments on Proposed
WP02 PRR: Master Oscillator and RF Reference Distribution
Update of CLIC accelerating structure design
Recent high-gradient testing results from the CLIC XBoxes
CEPC RF Power Sources System
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
CLIC Feasibility Demonstration at CTF3
Undulator Cavity BPM Status
Breakout Session SC3 – Undulator
Presentation transcript:

EUCARD WP12 DESY 2015 Slide 1 EuCARD-2 is co-funded by the partners and the European Commission under Capacities 7th Framework Programme, Grant Agreement Speaker A. C. Dexter On behalf of crab cavity and Xbox teams Synchronization issues and crab cavity update

EUCARD WP12 DESY 2015 Slide 2 Overview Categories of timing problems Clock to accelerator cavity CLIC crab cavity synchronisation Double balance mixer measurements Active waveguide path length control experiments Crab cavity testing

EUCARD WP12 DESY 2015 Slide 3 Categories of Timing Problems Stability  Oscillators shift period with temperature, vibration etc.  Voltage Controlled Oscillator (VCO) shifts period with applied voltage  Atomic clock  f/f ~ ~ 60 fs per minute Synchronisation  Two clocks with different periods at same place (Phase Locked Loop)  Identical delivery time/phase at two places (Crab Cavity Problem)  Same clock at two places  Resynchronisation requires constant propagation time of signal  Detector with high resolution and low noise Trigger an event at a later and a different location  Needs two stable clocks which are synchronised (FEL problem)  Must be able to generate event from clock pulse with tiny jitter  Work at DESY and MIT suggest 10fs achievable

EUCARD WP12 DESY 2015 Slide 4 Clock to cavity Optical clock signal Locked microwave oscillator Solid state amplifier IQ modulator Solid state amplifier TWT amplifier Klystron Pulse compressor Waveguide Cavity sensitive to temperature Extremely sensitive to modulator voltage LLRF control - feedforward to next pulse based on last pulse and environment measurements Absolute timing impossible as every component and connector adds phase uncertainty

EUCARD WP12 DESY 2015 Slide 5 CLIC Cavity Synchronisation Cavity to Cavity Phase synchronisation requirement Target max. luminosity loss fraction S f (GHz)  x (nm)  c (rads)  rms (deg)  t (fs) Pulse Length (  s) So need RF path lengths identical to better than c  t ~ 1.3 microns CLIC bunches ~ 45 nm horizontal by 0.9 nm vertical size at IP.

EUCARD WP12 DESY 2015 Slide 6 RF path length measurement 48MW 200ns pulsed GHz Klystron repetition 50Hz Vector modulation Control Phase Shifter 12 GHz Oscillator Main beam outward pick up From oscillator Phase shifter trombone (High power joint has been tested at SLAC) Magic Tee Waveguide path length phase and amplitude measurement and control 4kW 5  s pulsed 11.8 GHz Klystron repetition 5kHz LLRF Phase shifter trombone LLRF Cavity coupler 0dB or -40dB Expansion joint Single moded copper plated Invar waveguide losses over 40m ~ 3dB -30 dB coupler Forward power main pulse 12 MW Reflected power main pulse ~ 600 W Reflected power main pulse ~ 500 W Waveguide from high power Klystron to magic tee can be over moded Expansion joint RF path length is continuously measured and adjusted

EUCARD WP12 DESY 2015 Slide 7 Layout for initial waveguide test GHz Magic Tee C   C Moveable Short E bend H bend E bend H bend gas valve Power detector +33 dBm -10 dBm C C 10 dB Diode Switch Power detector Moveable Short C C 20 dB p s s p p s s s s p p p p s s s p s p s p s p s p s s s p s p p s p s p p p p p = plane s = groove seal s power/phase calibration gas valve s p s p Power ws Attenuator

EUCARD WP12 DESY 2015 Slide 8 Double balanced mixer We plan to use mixer with LO and RF inputs that are equal in magnitude and frequency. And it is of interest to consider performance for this case. LO RF IF Balancing transformer for RF input (Balun) s t u v Simplistic noise calculations indicate that resolution at the level of 1 milli-degree for a micro second pulse is theoretically possible with packaged double balanced mixers. Propose using Mini-circuits 20GHz SIM_24MH+ level 13 mixer, for 12 GHz LO input at 13dBm and low power GHz RF input, Conversion loss = 5.8 dB, LO-RF isolation =36dB, LO-IF isolation~19dB, VSWR RF = 2.0, VSWR LO ~ 3.5

EUCARD WP12 DESY 2015 Slide 9 DBM with equal inputs

EUCARD WP12 DESY 2015 Slide GHz Power Detector +20 dBm -10 dBm Diode Switch Power Detector ws Attenuator National Instruments PXI Crate 16 bit A to D conversion at 120Mb/s on 4 channels channel 1 = DBM (range~ 30 o ) channel 2 = LPD (range ~ 360 o ) channel 3 = power 1 channel 4 = power 2 ws = Wilkinson splitter phase shifters DBM power/phase calibration LPF PCB Calibrating phase measurement PCB DBM voltage output depends on power input. Need to shift one path on board by 90 so that zero output corresponds to identical phases arriving from waveguides.

EUCARD WP12 DESY 2015 Slide 11 Primary DBM RF input 1 RF input 2 Linear phase detector Mix down DBM Power detection Power out 1 Power out 2 Phase diff. (d.c.) Phase measurement PCB Signal is split before primary DBM so that power on both channels can be measured. Additional signals can be mixed down and measured with a linear phase detector hence large phase shifts induced by waveguide trombones or short scan be calibrated.

EUCARD WP12 DESY 2015 Slide 12 Staged waveguide testing 1. Calibration of detector electronics 2. Accurate phase measurements on a minimal system in a controlled environment. 3. Measurements of phase fluctuations on longer lengths of copper waveguide in an accelerator environment. 4. Controlling phase of reflections using actuators on moveable shorts. 5. Use of interferometry to set transmission length at the measurement frequency below 11.9 GHz and then to check path synchronisation at the high power cavity RF frequency of GHz. 6. Development and testing of trombone sections or bespoke phase shifters to replace moveable shorts.

EUCARD WP12 DESY 2015 Slide 13 Schedule TaskEffort weeks StartFinish 1Fabricate and test structures and component on measurement pcb Fabricate, test and calibrate prototype measurement pcb Program PXI for data collection Procure amplifiers, diode switches and circulator Complete fabrication and testing of 12.0 GHz and 11.7 GHz PLLs Design corrections and fabrication of second measurement pcb Final calibration of phase measurement board Fabricate stand for minimal waveguide test stage Test stage 1 calibrations for minimal waveguide system Flow graph analysis on system reflections affecting accuracy of measurement Test stage 1 long term drifts of minimal system in environmental chamber Fabricate stands for extended waveguide tests stages Test stage 2 measure phase fluctuations in accelerator environment Design and procure actuators for moveable shorts Test stage 3 close loop to control transmission lengths Test stage 4 control at 11.9 GHz for transmission at 12.0 GHz Test stage 5 development of bespoke phase shifters Test stage 5 validation of bespoke phase shifter

EUCARD WP12 DESY 2015 Slide 14 centring V guiding the wire for bead- pull measurements nitrogen supply input (chosen and marked) tuning pins (4 per cell) temperature sensor cooling block output (marked ) E. Daskalaki, A. Degiovanni, C. Marrelli, M. Navarro Tapia, R. Wegner, B. Woolley Bead pull of undamped crab cavity

EUCARD WP12 DESY 2015 Slide 15 CI-SAC Dec 2011 E surf H surf S surf =(ExH) surf Peak electric and magnetic fields of the dipole mode are located 90 degrees from each other on the iris Surface Poynting flux S surf is however at 45 deg to both E and H Location of the breakdown on the iris provides critical information about the role of magnetic field in breakdown. The cavity has a large Sc but relatively low E and H fields at the surface so this also provides an independent verification of new theories. PropertyCrab cavityCLIC_G Mode120°, GHz Q V group -2.9 %c %c Kick2.55 MV Gradient26 MV/m100 MV/m Power13.35 MW42 MW E surf 103 MV/m190 MV/m H surf 348 kA/m410 kA/m ΔT (200ns)26 K21 K Sc3.32 W/mm W/mm 2 Crab cavity cell under test

EUCARD WP12 DESY 2015 Slide 16 Crab Cavity RF Load Incident Power Reflected Power Transmitted Power Ion gauge read out 60 dB directional coupler Upstream Faraday cup signal Downstrea m Faraday cup signal RF In From Pulse Compressor WR90 Waveguide Input coupler Output coupler Beam-pipe Dipole Magnet Collimator Readout Screen Uppsala Dark Current Spectrometer Single feed structure requires a different feed to the accelerating structures. We can take advantage of extra diagnostics with the Uppsala dark current spectrometer. Radiation Monitor High power crab cavity testing

EUCARD WP12 DESY 2015 Slide MW December 2014 No pulse compressor

EUCARD WP12 DESY 2015 Slide MW Run th March BDR: 3.2e-7

EUCARD WP12 DESY 2015 Slide MW Run 17 th March: BDR: 3.2e-5

EUCARD WP12 DESY 2015 Slide 20 Crab testing Very low breakdown rate at CLIC power level Acceptable breakdown rate at double CLIC power level More data needed to establish breakdown rate dependence on SC parameter For CLIC could consider less cells and a lower group velocity. (CLIC constraints, power flow >> worst case beamloading only have 50MW, after waveguide losses ~ 13 MW per cavity would like to reduces wakefields to reduce vertical kicks hence less cells could be beneficial.)

EUCARD WP12 DESY 2015 Slide 21 Progress this year Twelve cell undamped crab cavity tuned High power testing of undamped cavity commenced Manufacture of damped cavity cells underway Waveguide for stabilisation experiment procured NI PXI create for fast data capture procured Planning of tests well advanced Electronic boards still under development Calibration procedures being devised