Medium Voltage SERVICE HPA development Information.

Slides:



Advertisements
Similar presentations
SHS2 Gas insulated switch–disconnector / isolator
Advertisements

© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
GENERATOR PROTECTION.
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
Resource Data Needed For Dynamic Simulations
GCB Service Earthing Switch Retrofit Kit for HGC-3 & HEC 3..6 ABB High Current Systems Services © ABB Group April 15, 2017 | Slide 1.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
Problem #2-8 A 480 – 120 V, 60 Hz transformer has its high voltage winding connected to a 460 V system, and its low voltage winding connected to a 24/32.8°Ω.
Today’s Topics 1- The per unit system 2-Transformer Voltage Regulation
Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
EE 369 POWER SYSTEM ANALYSIS
MV SF6 circuit-breakers for secondary distribution
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
Multi-function apparatus for secondary distribution
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Symmetrical Faults Instructor: MOHAMMAD ABDUL BASEER
Current Contribution from Wind Plant for a System Fault Working Group C17 May 2010 Meeting.
1.6 Real Single-Phase Transformer.
TRISHUL Winding Solutions Pvt Ltd ROTOR COILS  It is the moving part of a rotary system.
Chapter 17 Section 3 (pages )
Controls and Electrical Preferred Technologies Steve Pavis PH-DT-DI CERN Advel Power Supplies and ABB Circuit Breakers.
Electricity & Magnetism Chapter 19 and 20 Review for Test April 19, 2005.
All rights reserved MV SWITCHGEAR.
Electric network faults seen by a wind farm – analysis of measurement data Sanna Uski, Seppo Hänninen, Bettina Lemström.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
1 Department of Electrical & Communication Engineering CHAPTER 1 Per Unit Calculations 1.Power System Representation Power Component SymbolPower ComponentSymbol.
Lecture 18 Fault Analysis Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
ECE 476 Power System Analysis Lecture 17: OPF, Symmetrical Faults Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Three Phase Motors Maths
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
Department of Electrical Engineering
Submitted To:- Submitted By:- Mr.
A PRESENTATION On 400KV GSS SURPURA JODHPUR
Per-Unit System.
Formative Assessment. question practice problems.
Government Engineering College Rajkot
ECE 476 Power System Analysis
3AH5 Vacuum Circuit-Breaker For Standard Applications
Per-Unit System.
HD SIGNAL CONDITIONER SERIES
Name, department/event, date
Overview of PowerCube Units and ANSI frames
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Direct Replacement Retrofitting Solution
SION Vacuum Circuit-Breaker For Standard Applications
K4 Schematic Analysis and Pictorial Diagram
Exercise 7 Power systems.
Technical sheet N°1 Using at frequency 60 Hz All cb’s
Inside a plug Ms. Edwina.
K5 Schematic Analysis and Pictorial Diagram
Direct Replacement Retrofitting Solution
Exercise Session 2 Power systems.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Schematic to Pictorial
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Power System Analysis (EELE 4351)
Its strengths, your benefits
Prepared by: Ismael K. Saeed
Exercise Session 11 Power systems.
Exercise 9 Power systems.
ELECTROMAGNETISM.
Exercise 6 Power systems.
Presentation transcript:

Medium Voltage SERVICE HPA development Information

© ABB PT. - Page 2 Medium Voltage Service Necessary details for HD4-HPA Retrofit solution development  Essential technical data Name plate on the existing breaker with Serial number Type Rated Voltage Rated Current Short Time withstand Current Auxiliary voltage for coils and spring charging motor  Clarification of electrical/mechanical interchangeability Front, Rear, Side CB pictures (prefereable bottom side and front top) Internal view of the MV panel enclosure (preferable bottom side and rear side) Shutters condition Anti-introduction interlock position Main contacts resin insulation Existing CB schematic diagram In case of Generator CB, to be filled the relevant data sheet

© ABB PT. - Page 3 Medium Voltage Service Necessary details for Retrofit solution Picture of name plate Positioned on the CB Front For every breaker type

© ABB PT. - Page 4 Medium Voltage Service Necessary details for Retrofit solution Front, rear, side Pictures Bottom side and Front Top details

© ABB PT. - Page 5 Medium Voltage Service Necessary details for Retrofit solution Enclosure Internal view Shutters condition

© ABB PT. - Page 6 Medium Voltage Service Necessary details for Retrofit solution Anti-introduction interlock position Verify the pins position Left or Right side Interlock No Interlock

© ABB PT. - Page 7 Medium Voltage Service Necessary details for Retrofit solution Main Contacts Resin Insulation Verify whether the resin Insulation is present on the main contacts

© ABB PT. - Page 8 Medium Voltage Service Necessary details for Retrofit solution Existing Panel Schematic diagram Schematic diagram clarify the accessories included into the existing breaker and the aux. contacts wired to the sliding plug

© ABB PT. - Page 9 Medium Voltage Service Necessary details for Retrofit solution Generator Breaker Data sheet 2. Technical data of generator: Rated voltageU r [kV] Rated apparent powerS r [MVA] Rated frequencyf r [Hz] Subtransient direct axis reactance (saturated)X d ‘‘[%] Transient direct axis reactance (saturated)X d ‘[%] Synchronous direct axis reactance (saturated)X d [%] Subtransient short-circuit time constantT d ‘‘[ms] Transient short-circuit time constantT d ‘[ms] Armature short-circuit time constantT a [ms] 3. Data of network: Short circuit power of high voltage networkS k ’’[MVA] Rated power of main transformerS r [MVA] Impedance voltage of main transformeru k [%] Rated power of auxiliary transformer *) S r [MVA] Impedance voltage of auxiliary transformer *) u k [%] Rated power of connected medium voltage motor(s) *) P r [MW] Rated motor current related to motor starting current *) I r /I a [p.u.] Single line diagram of network Generator Information Net Information

© ABB PT. - Page 10