EIChroM I N D U S T R I E S, I N C. Introduction of Eichrom TEVA Disc: Tc-99 Analysis Anil H. Thakkar, Lawrence Jassin, Michael Fern Eichrom Industries,

Slides:



Advertisements
Similar presentations
New QC Procedure for Eichrom Resins: Why We’re Changing Joel Williamson, Jill Bernstein, Dan McAlister and Phil Horwitz Eichrom Technologies, Inc.
Advertisements

Ra in Water using MnO2 Resin: New Developments
What are these pieces of equipment called? Garden sieve Colander Kitchen sieve What are they used for?
Anomalous Behavior of TEVA Resin Prepacked Columns: A Technical Update Anil Thakkar November 1st 2004 Cincinnati, OH.
Advantages to Automating the 1664 Method Joe Boyd March 28, 2012.
InfraCal TOG/TPH Analyzer, Model HATR-T2 Extraction Procedure.
Measurements of Ra Isotopes via MnO2 Resin
1 Anil Gupta, 2 Sonali Bhade, 2 P. J. Reddy, 1 P. K. Kale, 1 K. Narayanan Kutty, 2 D.A.R. Babu, 1 R. G. Purohit and 1 Dr. P. K. Sarkar 1 Health Physics.
InfraCal TOG/TPH Analyzer, Model CVH Extraction Procedure.
D. P. DiPrete, C. C. DiPrete, and R. A. Sigg
Technical Updates on UTEVA, TEVA and TRU Resins
Introduction into LS theory and practice. Agenda  Energy deposition  Overview of the LSC process  Theory of operation  Quenching  Machine  Uses.
Detecting Melamine in the Food Supply Michael Parks CHEM 4101, Fall /04/09.
Methods Monitoring Polar Compounds Using Membrane Extraction and High-Speed Gas Chromatography Authors: Jonathan Maurer, Dr. Anthony J. Borgerding* Department.
Rapid Separation Methods for Bioassay Samples S. L. Maxwell, III and D. J. Fauth Westinghouse Savannah River Site.
Water Pollution… and how to clean it up! Experiment with different types of water pollution Make your own water filter.
Distillation and Chromatography. Objectives Separate the components of a solution using distillation and chromatography Determine physical or chemical.
MnO 2 Resin: Concentration of Radium Isotopes Deok-Soo Moon Bill Burnett Department of Oceanography Florida State University Tallahassee, Florida.
GROSS ALPHA DETERMINATION IN DRINKING WATER USING A HIGHLY SPECIFIC RESIN AND LSC
The Determination of 226 Ra in Water Samples Anil H. Thakkar Eichrom Technologies, Inc. eichrom TECHNOLOGIES INC.
The Determination Of 226 Ra In Soil Samples Lawrence D. Morris General Engineering Laboratories, Inc. Anil H. Thakkar Eichrom Technologies, Inc.
The Determination of 224 Ra, 226 Ra, & 228 Ra in Water Samples Michael Fern Eichrom Technologies, Inc.
Applications of Extraction Chromatography in Marine Geochemistry
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
Determination of Sr-89/Sr-90 in primary cooling water
Ultra-Trace PCB Sampling
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Radioactive Materials Analytical Laboratory Eichrom Technologies Inc. User Group Meeting May 2001 J.M. Giaquinto, L.D. Bible, D.C. Glasgow, J.M. Keller.
Actinide Analysis from Large- Volume Seawater Samples Bill Burnett & Guebuem Kim Department of Oceanography Florida State University and Phil Horwitz PG.
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene Research at The University Of Akron C. Shin and G. G. Chase Polymer Nanofibers from Recycling.
Rapid Actinide Analysis for Large Soil Samples-Update Sherrod L. Maxwell, III Westinghouse Savannah River Company.
MnO 2 Resin: Concentration of Radium Isotopes Deok-Soo Moon Bill Burnett Department of Oceanography Florida State University Tallahassee, Florida.
Elution and Mounting Techniques for Americium using Eichrom TRU Resin Mitch Abbate Radiochemistry Technical Director Severn Trent Services St. Louis May.
General Engineering Laboratories Use of Eichrom Resins for Bioassay Pa-231 Bob Timm - GEL Tim Chandler - GEL Bill Burnett - FSU Mike Schultz - PerkinElmer.
Developments in Environmental Radiochemistry* Environmental Radioactivity Measurement Facility Department of Oceanography Florida State University Tallahassee,
The Determination of 226Ra in Water Samples
Updates from Eichrom’s Tech Support Lab Anil Thakkar May 4 th 2004 Charleston, SC.
New Extraction Methods for Actinides in Urine at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Th, Pu & U Separation Using TEVA and UTEVA Resin
Performance Testing of Selected Liquid Scintillators Julian Dean Centre for Ionising Radiation Metrology, NPL.
Recent Improvements in Rapid Column Separation Methods at SRS
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
 Extraction of OM  Rock-Eval (Pyrolysis)  Elemental analysis  GC, HPLC & MS  SIRMS.
Rapid actinide measurements in environmental samples Dr Phil Warwick Geosciences Advisory Unit Southampton Oceanography Centre.
Determination of 210 Pb in mineral waters using Eichrom Resin Alžbeta Ďurecová, Dagmar Bursová, František Ďurec, Daniela Borošová State Institute of Public.
DILUTION CALCULATIONS Molarity of Mixture = total moles of chemical in which we are interested total volume of mixture Dilute Solution – a solution with.
On-line Actinide Quantification with Extractive Scintillating Resins Timothy A. DeVol, James E. Roane, Lara D. Hughes Clemson University Eichrom Users’
New Fecal Method for Plutonium and Americium at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Optimizing Radiochemical Methods at SRS (Ni-63, I-129, Actinides) Sherrod L. Maxwell, III Westinghouse Savannah River Company.
One-Column Separation and Analysis of Isotopic Am and Pu in Soil Samples Nidal M. Jadalla, Eberline Services, Albuquerque, NM Anil Thakkar, Eichrom Technologies,
THC in Oral Fluid by LC-MS/MS Kristine Van Natta 24 Sep 2010.
An Improved Method for Determination of Ra-228 * Jamie Christoff & Bill Burnett Department of Oceanography Florida State University “The Double-Pass Approach”
James Byrd, Marta Kozak 28 Apr 2011
Anil H.Thakkar Eichrom Industries, Inc.. Darien, IL
M. Iammarino, D. dell’Oro, N. Bortone, A. E. Chiaravalle*
The Determination of 226Ra in Water Samples
Crystallization & Filtration
Strontium Extraction from Urine Samples
Kun-Ho Chung, Mun-Ja Kang Korea Atomic Energy Research Institute
The common lysis solutions contain A. sodium chloride.
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene
Extraction and isomerization rates of α-acids for bittering beer
Ra in Water using MnO2 Resin: Update
Extraction Procedure (2)
Technical Updates on TRU and TEVA Resins
Technetium-99 in Urine Tabitha Liebrecht & Buzz Vickery
Rapid Emergency Methods for Actinides and Sr-89/90
Eichrom Resin Columns: A New breakthrough
National Air and Radiation Environmental Lab
Darrell Clinton and H. Dorota Inerowicz Purdue University
Presentation transcript:

EIChroM I N D U S T R I E S, I N C. Introduction of Eichrom TEVA Disc: Tc-99 Analysis Anil H. Thakkar, Lawrence Jassin, Michael Fern Eichrom Industries, Inc. and John Sisler EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. Current Eichrom Tc-99 Method TEVA Resin column Industry standard Flow rate limitation EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. Proposition Perform Tc-99 analysis rapidly with a new chromatographic configuration of the TEVA Resin EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. TEVA Disc Glass fiber filter 47 mm diameter 0.5 g silica based TEVA Resin EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. Outline of Proposed Method Place TEVA Disc on a filtering funnel Pass 1 liter of sample (at pH 2) through disc (NO vacuum necessary) Rinse disc with 0.01M HNO 3 Transfer disc to LSC vial EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. Method (continued) Add 15 mL Packard’s Ultima Gold LLT ® cocktail Stir or shake to form a gel Count on liquid scintillation counter EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. LSC Parameters Counter: Packard Tri Carb 2550 TR/AB Beta window: keV tSIE: Typically Counting efficiency 90% Count time: 30 minutes Detection limit: 1.77 pCi/L EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. Flow rate Typical 33 mL/minutes (30 minutes for 1 liter sample) Achievable at gravity flow 200 mL/minute under vacuum EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. %Tc-99 Recoveries DI Water (1 Liter)

EIChroM I N D U S T R I E S, I N C. %Tc-99 Recoveries Simulated Hanford Ground Water (1 liter)

EIChroM I N D U S T R I E S, I N C. %Tc-99 Recoveries Large Volume SHGW Samples

EIChroM I N D U S T R I E S, I N C. Field Trial: Tc-99 Analysis Data Provided by John Sisler Method comparison (TBP vs. TEVA Disc) Performance comparison Waste reduction Time savings EIChroM I N D U S T R I E S, I N C.

EIChroM I N D U S T R I E S, I N C. TBP Extraction Method Make ~200 mL preserved ground water 6 N H 2 SO 4 (Requires 40 mL conc. H 2 SO 4 ) Add 1% KMnO 4 Add TBP and shake vigorously Collect the TBP and centrifuge Mix 4 mL extract with 0.2 mL 20% SnCl 2 -HCl and 12 mL Insta-Gel ® cocktail Count via LSC for 30 minutes

EIChroM I N D U S T R I E S, I N C. TEVA Disc Method Add 1% KMnO 4 to ~200 mL preserved ground water sample Condition TEVA Disc with 20 mL DI water Pass sample through disc Rinse with 50 mL DI water Transfer disc to LSC vial adding 16 mL Insta- Gel ® cocktail and 0.2 mL SnCl 2 -HCl Count via LSC for 30 minutes

EIChroM I N D U S T R I E S, I N C. Ground Water Analysis Data (ppm)

EIChroM I N D U S T R I E S, I N C. Comparison TBP vs. TEVA Disc

EIChroM I N D U S T R I E S, I N C. TEVA Disc Spike Recovery

EIChroM I N D U S T R I E S, I N C. Waste and Time Savings (Batch of 20)

EIChroM I N D U S T R I E S, I N C. Summary Eichrom TEVA resin disc provides fast separation of Tc-99 Extremely easy sample preparation steps Good, reproducible and consistent recoveries achievable EIChroM I N D U S T R I E S, I N C.