Filipe Castro Departamento de Física & i3n Universidade de Aveiro C S I(N A ) W AVELENGTH - SHIFTING FIBER GAMMA CAMERA USING S I PM S LIP Lisboa Apr.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Instruments for Radiation Detection and Measurement Lab # 4.
Advanced GAmma Tracking Array
Comparison of 3 types of scintillator strips and 2 types of reflector films Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured.
Gamma Camera Technology
Tests of scintillators CsI, CsI(Na), BGO, NaI(Tl) CsI(Tl)
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Performance Evaluation of SiPM Arrays under Strong Magnetic Fields
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
8/18/2015G.A. Fornaro Characterization of diffractive optical elements for improving the performance of an endoscopic TOF- PET detector head Student: G.
Xiaodong Wang ( 王晓冬 ) School of Nuclear Science and Technology Lanzhou University, Lanzhou, China MPGD activities at Lanzhou University July 5, 2013.
Photon detection Visible or near-visible wavelengths
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
Development of New Detectors for PET Imaging at BNL DOE/JLAB Meeting Bethesda, MD May 20, 2004 Craig Woody Physics Dept Brookhaven National Lab RatCAPBeta.
SiPM: Development and Applications
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Active Pixel Sensors in Nuclear Medicine Imaging RJ Ott, N Evans, P Evans, J Osmond, A Clark, R Turchetta Physics Department Institute of Cancer Research.
F.Murtas1IMAGEM DDG GEM technology for X-ray and Gamma imaging IMAGEM l Detector setup l First results on X-ray imaging l First results on Gamma ray imaging.
Diego Gonzalez Diaz (Univ. Zaragoza and CERN)
Development of a Gamma Camera Based on an 88 Array of LaBr3(Ce) Scintillator Pixels Coupled to a 64-channel Multi-anode PMT Hidetoshi Kubo, K.Hattori,
Seoul National University Functional & Molecular Imaging System Lab Progress in Nuclear Imaging Mikiko Ito, PhD Dept. of Nuclear Medicine, Seoul National.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Enhancing InBeam PET with single Photon (Compton) Detection CERN September 2nd 2008 VALENCIA GROUP, IFIMED José M. Benlloch (PET hardware, speaker) José.
Photomultipliers: Uniformity measurements L. Pereira 1, A. Morozov 1, M. M. Fraga 1, L. M. S. Margato 1, P. Assis 2, R. Conceição 2, F. A. F. Fraga 1 1.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
R. Pani Department of Experimental Medicine and Pathology University of Rome La Sapienza-Italy. Flat Panel PMT: advances in position sensitive photodetection.
A Single Photon Emission Computer Tomograph for breast cancer imaging S. Vecchio a, N. Belcari a, P. Bennati b, M. Camarda a, R. Campanini c, M. N. Cinti.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Towards a high-resolution fluorescence telescope B. Tomé (LIP) IDPASC School on Digital Counting Photosensors for Extreme Low Light Levels, Lisboa,
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
MPPC Test Setup Alam Toro S. 1. Objective Characterize main variables in ideal conditions To provide a setup to characterize multiple devices To provide.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Peter Dendooven LaBr 3 and LYSO monolithic crystals coupled to photosensor arrays for TOF-PET Physics for Health in Europe Workshop February 2-4, 2010,
Jornadas do LIP 2012 L. Pereira 1 Gaseous Anger Camera Emulation An experimental system to study the design and optimization of gaseous detectors with.
Acquisition time6 min1 min 12 s Collimator height25 mm (Anger)12 mm (HiSens) Detector1 layer, 1 pixel / hole3 layers, 1 pixel / hole3 layers, 4 pixels.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.
Multimodality Intraoperative Imaging for Cancer Surgery Laboratoire Imagerie et Modélisation en Neurobiologie et Cancérologie (UMR 8165) F. Bogalhas, M.A.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Nuclear Medicine Introduction
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Muhammad Musaddiq.
SiPM readout ASIC for CTA N. Fouque, R. Hermel, G. Lamanna, F. Mehrez, J.L. Panazol, J. Prast, S. Rosier LAPP Annecy le Vieux.
Molecular Breast Imaging – state of art of design, analysis and optimization processes in industrial context F. Cirillo 1, F. Garibaldi 2,3, S. Gioia 1,
Nuclear Medicine Physics
IFR Detector R&D status
IFR Detector R&D status
Activities at SMI/Vienna in testing the performance of SiPMs
Performance of scintillation pixel detectors with MPPC read-out and digital signal processing Mihael Makek with D. Bosnar, V. Gačić, L. Pavelić, P. Šenjug.
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
FINAL YEAR PROJECT 4SSCZ
Image quality and Performance Characteristics
Development of a Compton Camera for online range monitoring
Image quality and Performance Characteristics
Detailed simulations of a full-body RPC-PET scanner
E > 100 keV activities at DTU Space ½ MeV Telescope Design
Development of a High Precision Axial 3-D PET for Brain Imaging
Lecture 1: Development of the Analog Gamma Camera
Application of Nuclear Physics
3x3-MPPC-SMDx16ch SiPM tileable modules from Hamamatsu
HE instrument and in-orbit performance
md-NUV PET project meeting
Assist. Prof. Dr. Ilker Ozsahin Oct
Presentation transcript:

Filipe Castro Departamento de Física & i3n Universidade de Aveiro C S I(N A ) W AVELENGTH - SHIFTING FIBER GAMMA CAMERA USING S I PM S LIP Lisboa Apr IDPASC School on Digital Counting Photosensors for Extreme Low Light Levels

2 Improve sensitivity of scintigraphy exams Typical radionuclide: 99m Tc (140 keV, T 1/2 = 6.02 h ) Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera Bénard and Turcotte, Breast Cancer Research (2005) Mammoscintigraphy images with 99m Tc-MIBI: Better spatial resolution Better positioning with compact portable app.-specific camera Earlier detection of smaller tumours Reduce rate of negative biopsies MOTIVATION

3 Design Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera 1x1 mm 2 Hamamatsu SiPM MPPC S U λ -shifting fibers to read out γ -rays’ position of interaction in the crystal SiPMs to detect light from optical fibers (also Ma-PMTs) E-PMT to provide energy signal and trigger for acquisition 64 anode Hamamatsu Ma-PMT C S I(N A ) WAVELENGTH-SHIFTING FIBER GAMMA CAMERA Patent number WO A2

Photon detection components and characteristics Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera C S I(N A ) WAVELENGTH-SHIFTING FIBER GAMMA CAMERA Crystal with embedded fibers: Photodetector efficiency: nm to 494 nm trapping efficiency > 5.6%

5 Assembling and testing small prototype with 10x10 SiPMs (1cm 2 ) Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera EXPERIMENTAL SETUP SiPMs E-PMT TRIGGER SiPMs SiPM E-PMT TRIGGER

6 Readout electronics Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera EXPERIMENTAL SETUP With larger initial RC and final CR–RC shaping With lower initial RC and no last stage

7 Readout electronics Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera EXPERIMENTAL SETUP With larger initial RC and final CR–RC shaping With lower initial RC and no last stage

8 Temperature influence Intro Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera RESULTS T = 25˚C Constant gain T = 20 ºCT = 25 ºC

9 Imaging with 57 Co (122 keV) Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera RESULTS – 10 X 10 S I PM PROOF - OF - CONCEPT PROTOTYPE Two positioning algorithms, based on maximum values: 1 mm hole Pb collimator manual positioning over (x,y) positions, i = SiPM with max. signal, for the n neighboring SiPMs which signal sum is maximum (1,1)(2,2)(3,3)(4,4)(5,5)(6,6)(7,7)(8,8)(9,9) (10, 10) E res ~ 23% FWHM V bias common to each 10 SiPM, T = 20ºC

10 Imaging with 57 Co (122 keV) : 4-hole Pb collimator Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera RESULTS – 10 X 10 S I PM PROOF - OF - CONCEPT PROTOTYPE

11 Imaging with 99m Tc (140 keV) Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera Parallel-hole collimator from large FOV gamma camera L=40 mm, d= 2 mm, t ≈ 200 µm RESULTS – 10 X 10 S I PM PROOF - OF - CONCEPT PROTOTYPE Syringe needle with 99m Tc

12 Imaging with 99m Tc (140 keV) Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera RESULTS – 10 X 10 S I PM PROOF - OF - CONCEPT PROTOTYPE A ~ 100 uCi E res ~ 20% FWHM V bias common to each 10 SiPM, T = 20ºC

larger crystal assembled with fibers glued to SiPM-coupling pieces 4 E-PMTs to read out crystal biasing SiPMs in groups of 8 Larger prototype (10x10 cm 2  100x100 SiPMs): Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera 13 ONGOING AND FUTURE WORK 16 channel SiPM power supply PCB developed by ISA S.A. (Coimbra), 8 bit DAC to adjust ~ V

biasing R6236 E-PMTs with individual compact PCB HV supplies readout with VA32HDR14.2 chips  DAQ with X3-10M (also V bias control) SiPM cooling Small animal or phantom studies, prototype characterization Larger prototype (10x10 cm 2  100x100 SiPMs): Motivation Exp. setup Results Ongoing and future work CsI(Na)-WSF gamma camera 14 ONGOING AND FUTURE WORK Hamamatsu C drawn to scale

Questions? Doubts? Ideas? Remarks? 15 Coffee? THANKS FOR THE ATTENTION! Acknowledgments: DRIM UA (João Veloso, Carlos Azevedo, Ana Luísa, Lara, Moutinho, …) A.J.D. Soares (project mentor) Jorge Isidoro (Nuclear HUC) ISA S.A. (Rodrigo Ferreira, Miguel Ferreira)

16 Conventional gamma camera Main componentsFunction Collimator (Pb) accept only γ -rays alligned with holes Scintillation crystal, e.g. NaI(Tl) convert γ -rays into visible light Photodetectors, e.g. PMT convert light into electric signals Electronics and softwaresignal processing and image formation