Electronic Timing Official Training Clinic – May 1, 2016 Update.

Slides:



Advertisements
Similar presentations
TUTORIAL 1 Getting Started with Excel
Advertisements

Administrative Official Training Clinic. Agenda Introductions Role of Administrative Official Certification Process Meet Setup in Hy-Tek Meet Manager.
Meet Manager Training Updated April Step 1: Set up your meet Download the meet template Restore the template Purge Old Data Setup Meet Information,
NSA Electronic Notary Log. Enter the name of the County that the Signing took place Orange The next time you run the program the County you entered will.
Quick Overview of program operation By Dave Abineri
MHSL - Dolphin Training Class
HY-TEK’s MEET MANAGER 4.0 Feature List Overview endurance.
Electronic Timing Official Training Clinic
Track & Field 1 SWIM MEET MAGAGER 5.0 NEW FEATURES Updated May 19, 2013.
Twin City Swim Conference
Page 1 of 11 Lessees can submit individual Unit Values for their Production Entities if they do not want to utilize the default unit value. If no Unit.
SL-10 Laboratory Hot Tack / Seal Tester TMI Group of Companies TMI Group of Companies.
XP New Perspectives on Microsoft Excel 2003, Second Edition- Tutorial 8 1 Microsoft Office Excel 2003 Tutorial 8 – Developing an Excel Application.
2008 COLLEGIATE CLINIC February 23, 2007  BAT INSPECTION PERMIT CORRECTIVE ACTION  HELMET INSPECTION WE NO LONGER DO THIS  CONFISCATED EQUIPMENT GIVE.
Approved by the BCSSA Rules & Regulations Committee February 2014 BC Summer Swimming Association Officials Certification Program.
Meet Directors Guide Steps for Running a Efficient and Effective Swim Meet.
EXCEL PART1. Objectives  Understand spreadsheet software  Tour the Excel 2010 window  Understand formulas  Enter labels and values and use the Sum.
Mountain High Swim League Scoring Presentation 2015 Scoring Committee 1.
Quick Start Guide. This 22 page introduction to the Financial Assessment Subsystem provides the user with a visual overview of the components of the system.
Electronic Timing Official Training Clinic. Agenda Introductions Role of ET Official Certification Process Equipment Setup Operating the Console Paperwork.
Committing to the future easyEmission – step 2 Software set-up for Engine Testing.
EASY TEAM MANAGER By Dave Abineri EASYWARE: PO Box 231, Milford, OHIO (Cincinnati) Phone: (513) Use UP arrow to move to the NEXT slide Use.
The Administrative Official Pacific Northwest Swimming May, 2013.
Timer Certification Clinic. Timer Certification A prerequisite for training and certification in all other positions (Descriptions in some of the following.
CPSC 203 Introduction to Computers T43, T46 & T68 TA: Jie (Jeff) Gao.
Label production Solution with Label Gallery programs Label Gallery is used for general label design and print GalleryForm is used to create data entry.
Approved by the BCSSA Rules & Regulations Committee ] BC Summer Swimming Association Officials Certification Program.
Important information & instructions for doing web upgrade :  User needs to backup all his data before doing web upgrade as the same will get deleted.
Committing to the future easyEmission - Testing Module for Engines.
Overview of Reading-Program Data Tools in the Member Center
Timing measures the swimmer’s performance, by accurately determining the time it takes each swimmer to cover the distance of the event. Final placement.
Thank you for your decision to try vTreePro Practice Tree Software! Your satisfaction is very important to us. Please feel free to send us an if.
Administrative Official Training Clinic. Agenda Introductions Role of Administrative Official Certification Process Meet Setup in Hy-Tek Meet Manager.
Week 25: Mon + Tues. (Watch video before taking survey) *Check to take Survey!!!
Using TEAM MANAGER & MEET MANAGER for High School Swim/Dive Meets Matt Stewart, Casey O’Hara
ADMINISTRATIVE OFFICIAL CLINIC Wisconsin Swimming LSC Version 1.4.
6 x 99 Think: round off 99 to 100 So… 6 x 99 becomes 6 x 100 = 600 Then subtract: 600 – 6 = x 79 4 x 80 = 320 – 4 = 316.
How to install Office 2007  Step 1: Insert the Microsoft Office 2007 Enterprise CD. If the Setup Wizard does not automatically begin, then click Start.
Forces & Motion Tutorial. Gravity An attraction between any two objects –All objects that have mass have gravity –Check out the website below: –
FOSTERING HEALTHY COMPETITION, TEAMWORK AND SPORTSMANSHIP SWIM OFFICIALS ADMINISTRATIVE OFFICIAL CERTIFICATION AQ336I – V1.0 OPTIONAL SLIDE DECK © 2014.
CALCULATING A REPLACEMENT TIME AKA EQUIVALENT ELECTRONIC TIME (EET)
Team Managers Package Indoor
SAM Payroll Processing Understanding and Using Payroll Features in SAM.
How to Setup and Score a Tournament May Let’s Get Organized The setup and organization outlined in this clinic are suggested steps however can be.
Internet Advancement Ore-Ida Council Boy Scouts of America.
Roles of the officials Orion Roberts. Identify officials Referee -The Referee is for watching the event. He will make decisions made by other judges and.
Administrative Official Training
Davisware GlobalEdge 2008 Payroll Main Menu Time Entry and Payroll Processing.
Remember…  Please do not…  Change the background.  Change the icons.  Change the font. Use Times New Roman (size 12 font).  Use color. We cannot print.
Electronic Timing Official Training Clinic. Agenda Introductions Role of ET Official Certification Process Equipment Setup Operating the Console Paperwork.
CALCULATING A REPLACEMENT TIME AKA EQUIVALENT ELECTRONIC TIME (EET) 8/08 update AB Church.
ASA East Region Swimming Officials Group Prepared by David Robinson 1.
Updated for the 2016 Season. Agenda GRAL Handbook Personnel & Equipment Flow of Information Table Worker Duties.
2011 IT Training Frederick Summer Swim League Welcome to IT Training 2011 Season.
SCORING/TRACKING MAJ Dan Kidd (845)
Excel Lesson 15 Working with Auditing and Analysis Tools
Chief Timekeeper RE 2016/03.
Scoring Program 2012 What’s New!
Getting Started Guide.
International Computer Driving Licence Syllabus version 5.0
NVSL – HyTek “Cheat Sheet” for Team Data Coordinators
Balance Sheet Micro-Pinoy.
Timing Console Clinic-CTS 6
Administrative Official Clinic
CALCULATING A REPLACEMENT TIME a/k/a EQUIVALENT ELECTRONIC TIME (EET)
CALCULATING A REPLACEMENT TIME a/k/a EQUIVALENT ELECTRONIC TIME (EET)
CALCULATING A REPLACEMENT TIME a/k/a EQUIVALENT ELECTRONIC TIME (EET)
Microsoft Office Excel 2003
5/20/2017 Bay Ridge Bruce Reiter
Presentation transcript:

Electronic Timing Official Training Clinic – May 1, 2016 Update

Adjustment for Timing System Difference D Effective May 1, 2016, back-up times no longer need to be adjusted for timing differences. No need to look at the current previous and next heats to provide a consistent average. Use button time reported by timing console. Note that Colorado automatically deducts 0.15 s but Daktronics does not. Both are acceptable.

Automatic/Semi-Automatic/Manual Buttons & Watches have different adjustments due to human reaction time Start Human Delay Button Pad Watch Finish Colorado Timing Console automatically deducts 0.15 Human Delay

Time Verification (Pad, Button & Watches) At least one button confirms pad time Y Use pad time Watches confirm one button time and faster than pad Y Collect order of finish and coach’s time. Compare with pad/watch/button times. Use best judgment. Watches confirm each other and faster than pad Y Use watch average N At least one watch confirms pad time Y N N N Buttons confirm each other and faster than pad Y N Use button average ET TIP: Calculate the adjusted button average, when the pad is not confirmed & 2 buttons agree, before watch times arrive to speed the process! Use button time

Lane Timing Adjustment Button times and watch times need to be adjusted by “timing system difference” Check that there are 3 valid lanes for comparison Calculate average difference between pad and valid button (or watch) times in that heat For further confirmation, optionally check the Order Of Finish (OOF) to see that the adjusted time fits the place order Further investigation is needed when: Buttons slower than pad confirm each other Times validated “just barely” by approximately 0.30 seconds

Colorado 6 Automatically calculates the now obsolete lane timing adjustment on the buttons. Button times already have built-in subtraction of 0.15 seconds Need to turn off the built-in averaging system after May 1 st 2016.

Colorado 6 (continued) 1. Use the softkeys on the right to select “Setups” 2. Use Up/Down softkeys to select “Timing” 3. Use Up/Down softkeys to select “Automatic Backup Time Adjustment” 4. Use Off softkey to turn off

Colorado 5 It is acceptable to use the built-in 0.15 adjustment applied to the button times.

Daktronics Does not do any button adjustment Beware that button averages on the Daktronics printout may be rounded up instead of down (depending upon version) When using optional PC interface, keeps a running race log with all touches and buttons that can be retrieved.

Hy-Tek Meet Manager Software on the Results Computer Set up meets Manage entries Seed races with swimmers Prints heat sheets & psych sheets Captures the times from the timing console Assimilates the results Scores the meet Prints awards labels Hy-Tek can print out lane timing adjustment worksheet for buttons (aka “calc sheet”)

Hy-Tek “Calc menu” Calculates the average button time Do NOT use “Accept Adjusted” as this will apply the obsolete timing adjustment.