XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.
Product Data - XAS 375 JD6
Settings/Shutdowns - XAS 375 JD6
AIR SYSTEM INLET VALVE Spring loaded in the open position Control Air closes the inlet Also serves as check valve
No Load/ Starting Load Load solenoid Load solenoid Regulating valve Min Press valve Min Press valve Unloading valve Unloading valve
Unload Blow Down Unloading valve Regulating valve Unloading valve Min Press valve Load solenoid Min Press valve Load solenoid
No Load/Starting Load
Unload Blow Down
REGULATING SYSTEM REG VALVE Spring loaded Adjusting receiver pressure by changing spring tension to pressure gauge and loading valve to speed regulator to unloading valve Regulating pressure: Receiver pressure In order to regulate the pressure inside the reciever tank of our compressor, the air intake and the engine speed have to be controlled. This is done pneumatically. For that reason, we need regulating pressure. The regulating valve reduces the pressure inside the tank, thus providing the regulating pressure. This regulating pressure is then supplied to the unloader valve and the speed regulator or RPS. The air receiver pressure can be set to another value by adjusting the spring tension of the regulating valve. This is done by turning the handle on top the valve. Increasing the spring tension, by turning in, will increase the regulating pressure and consequently the pressure inside the vessel. Turning out will decrease the pressure.
AIR SYSTEM MIN PRESS VALVE Maintains a minimum pressure of 58 PSI for oil flow Also contains the final check valve
Control Panel
Load Solenoid Valve – 1089 9515 02
Maintenance – XAS 375 JD6
XC 2002 Controllers
XC2002 Controller - XAS 375 JD
XC2002 Control Module Display Fuel Level Engine Coolant Temperature Engine Oil Pressure Engine RPM Battery Voltage Service Timers Engine Inlet Air Temperature Fuel Consumption (L/H) Engine Fuel Temperature Regulating Pressure Log List – Will Hold last 30 Historic Codes Alarm List – Shows Active Alarms Only Parameters – Choose Another Language, Reset Service Timers, Change Measuring Units, etc…
Control Module – 1604 9516 01
XC2002 Controller John Deere codes will display here
XC2002 Controller
XC2002 Controller
XC2002 Controller – * Unit Type 2
J1939 Canbus Communication
J1939 Canbus Communication . Cont…
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
John Deere Engine Fault Code List
Displaying of J1939 DM1 Alarms
Electrical System
Legend
Detailed Electrical Diagram
John Deere – Tier III – RPS in place of Pneumatic Speed Regulator Regulating Pressure Sensor “Speed Sensor”
*Preheat Relay K1 Controlled by JDEC Starter Relay
K1 – Preheat Relay – JDEC Warning
Troubleshooting - Information
Troubleshooting - Information
Troubleshooting - Information
Preventive Maintenance Filter Kits – XAS 375 JD6
Preventive Maintenance Filter Kits – XAS 375 CD6
Spare Parts Recommendation
Committed to sustainable productivity.