Interdisciplinary Project with South Texas Project Funded by The Nuclear Power Institute 1.

Slides:



Advertisements
Similar presentations
Extended Surfaces Chapter Three Section 3.6 Lecture 6.
Advertisements

Transient Conduction: The Lumped Capacitance Method
Conduction Conceptests
Quiz – An organic liquid enters a in. ID horizontal steel tube, 3.5 ft long, at a rate of 5000 lb/hr. You are given that the specific.
Chapter 3c : One-dimensional, Steady state conduction (with thermal energy generation) (Section 3.5 – Textbook) 3.1 Implications of energy generation Involve.
Extended Surfaces Chapter Three Section 3.6.
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Todd Nelson Kendall Thacker ME 340 Semester Project Winter 2014.
Chapter 2: Overall Heat Transfer Coefficient
Analysis of Simple Cases in Heat Transfer P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Gaining Experience !!!
One Dimensional Steady State Heat Conduction
Thermal Analysis of short bake out jacket version 1 12-Nov-2013.
One-Dimensional Steady-State Conduction
Enclosure Fire Dynamics
Solutions of the Conduction Equation P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Idea Generates More Mathematics….
LINEAR SECOND ORDER ORDINARY DIFFERENTIAL EQUATIONS
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski and M. D. Hageman Woodruff School of Mechanical Engineering Extrapolating Experimental Results for Model Divertor.
Transient Conduction: The Lumped Capacitance Method
Dynamic Reduced-order Model for the Air Temperature Field Inside a Data Center G.W. Woodruff School of Mechanical Engineering Georgia Institute of Technology.
Conduction & Convection.
CHAPTER 8 APPROXIMATE SOLUTIONS THE INTEGRAL METHOD
Feasibility Analysis h T1 T2 T3 T4 T5 One Dimensional Transient Analysis One Dimensional Finite Difference Steady State Analysis T1 and T5 will be known.
Heat Transfer Rates Conduction: Fourier’s Law
Chapter 3: Unsteady State [ Transient ] Heat Conduction
Chapter 4 TRANSIENT HEAT CONDUCTION
Chapter 2 HEAT CONDUCTION EQUATION
CBE 150A – Transport Spring Semester 2014 Heat Transfer Introduction.
Introduction to Heat Transfer
Tutorial 5: Numerical methods - buildings Q1. Identify three principal differences between a response function method and a numerical method when both.
Heat Transfer in Structures
STEADY HEAT TRANSFER AND THERMAL RESISTANCE NETWORKS
1 Calorimeter Thermal Analysis with Increased Heat Loads September 28, 2009.
Chapter 2 HEAT CONDUCTION EQUATION
Thermal Model of MEMS Thruster Apurva Varia Propulsion Branch Code 597.
Dynamic Thermal Ratings for Overhead Lines Philip Taylor, Irina Makhkamova, Andrea Michiorri Energy Group, School of Engineering Durham University.
Chapter 3 Part 1 One-Dimensional, Steady-State Conduction.
Senior Design Team #18 Lacey Ednoff Brianna Beconovich Jarimy Passmore Jesse Poorman.
CHAPTER 5 MESB 374 System Modeling and Analysis Thermal Systems
Module 4 Multi-Dimensional Steady State Heat Conduction.
One-Dimensional Steady-State Conduction
Alex Gee Jon Locke Joe Cooper Kylie Rhoades Clara Echavarria Ice Energy Extraction.
BLACK&DECKER Jess Dibelka Mark Steimer Laura Traub Julianne Twomey 12/10/07.
HEAT CONDUCTION EQUATION
Chapter 1: Fourier Equation and Thermal Conductivity
Calculation of Cooling Time for an AISI 304 Steel Heating Rod Sayantan Ghosh Avinesh Ojha.
Convection: Internal Flow ( )
Chapter 27 Current and Resistance. Electrical Conduction – A Model Treat a conductor as a regular array of atoms plus a collection of free electrons.
Time Calculation of the Temperature Rise in an Electric Iron.
Chapter 2: Heat Conduction Equation
Heat Transfer System By Team Awesome: Sub-team Awesomer.
ERT 216 HEAT & MASS TRANSFER Sem 2/ Dr Akmal Hadi Ma’ Radzi School of Bioprocess Engineering University Malaysia Perlis.
Exercises for Q1. Insulated copper tube A thin walled 10 mm copper tube is used to transport a low-temperature refrigerant with a temperature that is.
STEADY HEAT CONDUCTION IN PLANE WALLS, Ch.3
Solution to Homework 1 qi h1 h2 q1 qo a1 a2 v1 v2
One-Dimensional Steady-State Conduction
One Dimensional Steady State Heat Conduction
INTRODUCTION : Convection: Heat transfer between a solid surface and a moving fluid is governed by the Newton’s cooling law: q = hA(Ts-Tɷ), where Ts is.
Minimum Cooling Time for Metallurgy Applications
Heat and Mass Transfer Heat is ……… Heat Transfer ……
Power Magnetic Devices: A Multi-Objective Design Approach
Extended Surface Heat Transfer
Thermal analysis Friction brakes are required to transform large amounts of kinetic energy into heat over very short time periods and in the process they.
Finite Volume Method for Unsteady Flows
Transient Heat Conduction
Thermal behavior of the LHCb PS VFE Board
Heat Transfer In Channels Flow
Steady-State Heat Transfer (Initial notes are designed by Dr
Heat Transfer in common Configuration
What are Fins ? Fins are extended surfaces used to increase the rate of heat transfer. It is made of highly conductive materials such as aluminum.
Egyptian Atomic Energy Authority (EAEA), Egypt
Presentation transcript:

Interdisciplinary Project with South Texas Project Funded by The Nuclear Power Institute 1

 Team Members: Matt Langston – CHEN: Senior Kyle Bowzer – MEEN: Junior Ryan Bigelow – MEEN: Junior Matthew King – MEEN: Junior Richard Colunga – ELEN: Sophomore Jennifer Banegas – CVEN: Freshman George Campa – CHEN: Freshman Brent Mayorga – AERO: Freshman  Mentors Graduate Mentor: Andron Creary TAMU Mentor: Mr. Cable Kurwitz STP Mentor: Mr Rick Grantom 2

Agenda  Motivation & Project Components  Project Objectives  CFD Analysis  Lumped Parameter Simulations  Experimental Results  Summary  Future Work

Motivation & Project Components  Motivation Provide STP’s Probabilistic Risk Assessment (PRA) Team with air temperature profile data after a hypothetical loss of HVAC. Provide STP’s Probabilistic Risk Assessment (PRA) Team with air temperature profile data after a hypothetical loss of HVAC.  Project Components CFD Analysis CFD Analysis ○ Using a SolidWorks created model of room and electrical cabinets Analytical Calculations Analytical Calculations ○ Perform calculations in Matlab using a Lumped Parameter Method Laboratory Experiments Laboratory Experiments ○ Run experiments investigating the heat transfer and energy storage within a solid material

Simulation Objectives  Determine air and metal heat up rates during various HVAC failure scenarios  Gain information on when and where the air temperature reaches manufacturer’s critical temperature (104 ° F)  Investigate the effect of energy storage within metal in the transformers using a cabinet CFD model

CFD - SolidWorks Model Inlets Inlets Outlets Heater Rods 6

Distribution of Heat Loss watts 3131 watts 1966 watts watts 200 watts 2234 watts 1759 watts 2519 watts 1523 watts watts

CFD Simulations  Computer Simulations Case 1: Steady State ○ Simulates the EAB room’s “Normal Operating Conditions” (50 ° F inlet air temp and cfm) Case 2: Transient ○ Simulates the loss of one of the HVAC trains (50% air flow) Case 3: Transient ○ Simulates the HVAC chiller failure (73°F inlet air temp instead of 50 ° F) Case 4: Transient ○ Simulates the total loss of HVAC 8

Case 1 - Temperature Profile for “Normal Operating Conditions” 9 64°F average

Case 1 - Maximum Temperature “Normal Operating Conditions” 10 Max air temp ~78 °F (above main cabinet) Max air temp between cabinets ~64°F (at 5ft) 5 ft

Case 2 - Temperature Profile “Half-flow Simulation” 11 68°F average SS after ~ 21min

Case 3 - Temperature Profile “HVAC Chiller Failure” 12 83°F average SS after ~ 19 min

Temperature Profile “Total HVAC Failure” When Critical Temperature (104 ° F) is Reached 13 Critical temperature (104F) location After ~19 minutes

Final Results Plot 14 Case 1 Case 3 Case 2 Case ° F

Energy Storage in Transformers  The HVAC failure problem is more complicated because it is a transient problem Stored thermal energy flow is important in the temperature history In particular, the heat up of the transformer’s copper windings and iron cores due to the high specific heat capacity.  Bounding the Specific Heat  Based on manufacturer’s specifications of transformer cabinets in the EAB room, metal mass composition values were assumed: Stainless steel: 15-20% Aluminum: 5-20% Iron: 20-60% Copper: 40-60%

Bounded Values  Using Matlab, all possible mass combinations were computed Used to determine max, min, mean of lumped specific heat Min CpAvg CpMax Cp J/kg*K J/kg*K J/kg*K

Transformer Cabinet Model

Cabinet Simulations  Steady state conditions with a uniform air flow across the cabinet’s outer surface  Transient simulation with no forced flow using: Maximum specific heat Minimum specific heat

Cabinet Temperature Profile: Steady State

Front View of Air Velocity Profile: Steady State

Side View of Air Velocity Profile: Steady State

Cabinet Simulation Results

Lumped Parameter Simulations (1/5)  Objective: Create a theoretical model of the EAB room’s thermal activity Provide an alternative solution method that will predict air heat up rate. ○ Provide confidence in computational model. Allow an additional means of connecting the simulation results with the experimental results. 23

In our current analytical approach, the room is reduced to two heat-storing masses, the cabinets and the air. From the basic equation for heat storage, two differential equations can be derived for the air temperature and cabinet surface temperature: Lumped Parameter Simulations (2/5) 24 and

Lumped Parameter Simulations (3/5) The two equations on the previous slide can be arranged in a heterogeneous linear system of equations, which can be solved simultaneously through matrix methods to yield: 25 and Where:is the second eigenvalue. (λ 1 = 0)

Lumped Parameter Simulations (4/5) To confirm simulation validity, geometric parameters were taken from SolidWorks model P g = heat generation = W = Btu/hr M air = mass of air in room = 5657 lbs M m = mass of cabinets = lbs Cp a = air heat capacity = Btu/lb °F Cp m = metal heat capacity =.117 Btu/lb °F 26

Lumped Parameter Simulations (5/5) Once all parameters are known, the constants C 1 and C 2 can be determined from initial conditions (t = 0). Initial conditions used: T air (0) = 63.4 °F and T m (0) = °F Once constants are known, equation for T air = 104°F can be solved for t, which may be used to determine T m at that time 27 From SS simulation under normal operating conditions

Analytical Solution Assumptions  Uniform heat generation.  The convection coefficient does not vary spatially.  The convection coefficient is fairly constant over the temperature range. 28

Overall Approaches  Three approaches: Perform calculations by hand/in Excel spreadsheet. Model simplified version in FloWorks with cabinets lumped together. Use differential equation solver ODE45 in MATLAB 29

Analytical Solution Results  Hand Calculations/Excel file (with h = 6 W/m 2 °C = Btu/hr ft 2 °F: 30

Analytical Solution Results 31 Simplified FloWorks Simulation (h calculated automatically by FloWorks a CFD package):

Experiment Overview 1. Goal 2. Approach 3. Experimental setup 4. Tests 5. Results

Experiment Goals  Determine thermal conductivity (k)  Benchmark the FloWorks CFD package using experimental results

3.7in 2.5in Experimental Setup ( 1 /2 ) Fourier’s Law

Experiment Setup (2/2 )  Aluminum & steel blocks 2.5x2.5x3.7 in  200 W cartridge heater Approximately 95% Efficiency  Block system: Cartridge heater and thermocouples are covered with silicone grease to remove insulating effects of air

4. Tests  Test 1: Insulated aluminum block Power remains constant Determine the thermal heat generation and conductivity (k)

5. Results Test 1: Temp Deviation at (deg C) k avg (W/m*K) k_standard (W/m*K)% Error in k

 Convection experiment using same setup  Conduct testing with different materials  Create FloWorks model with the same material and conditions to benchmark simulation results Experiment Future Work

Project Accomplishments Used computer simulation results to predict the heat-up rate of the EAB room. Normal Operating Conditions : ~63°F Half flow single train failure: ~79°F HVAC chiller failure: ~ 82.6°F Total HVAC failure: ~19 minutes after total failure (104°F) Derived equations to analytically calculate the heat-up rate using lumped parameter model. Heat-up rate: ~7 minutes after total failure (104°F) Designed an experimental setup that can be easily compared with a Cosmos FloWorks CFD package. 39

Andron Creary, Kyle Bowzer, Brent Mayorga, Matthew King, Ryan Bigelow, George Campa, Jennifer Banegas, Matt Langston, Richard Colunga QUESTIONS?