Experimental Procedure

Slides:



Advertisements
Similar presentations
The Care and Feeding of Burets
Advertisements

Determination of Calcium Carbonate in Eggshells
Acidity Constant by pH Titration Curves
Purpose Background - The Power of Antacids
SURVEY OF CHEMISTRY LABORATORY I CHEM 1151L ANTACID EVALUATION.
Antacids Titration Lab. Teacher Preparation 1.Gather all materials and place them in trays at each lab station. Have extra flasks, beakers & graduated.
Standardising potassium permanganate solution with iron(II) sulfate
ORYX Microbatch Screening Ran Meged -1-. Microbatch oil protein & reagent solution -2-
Titration By Dr H W Winter.
1 Objective:The objective of this experiment is to determine the mass of acetylsalicylic acid (ASA) in an Aspirin tablet. Chemicals Potassium hydrogen.
Laboratory Techniques I: Dilution Go to browse and set to full screen.
Calcium Determination Using EDTA THEORY AND INTRODUCTION
CHEMISTRY 1105 Determination of Absolute Zero using Vernier Equipment.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions BioRad Set Up 8 groups Grossmont Kit.
Preparation of Aspirin Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
Titration Pre-lab.
Chemistry e-lab: Acid-Base Titration
Exp 4C: How Much Acetic Acid is in Vinegar?
Experimental Procedure Lab 402. Overview Three different experiments are complete in a calorimeter. Each experiment requires careful mass, volume, and.
Lab Equipment Biology Foothill Technology High School.
RECRYSTALLIZATION, MELTING POINT, and HPLC ANALYSIS of ANALGESICS
Laboratory Techniques II: Titration
Performing a titration A bluffers guide! Preparing a standard solution 4 Accurately weigh a weighing bottle, recording the mass 4 Add approximately x.
TITRATION This involves removing small samples from the reaction mixture at different times and then titrating the sample to determine the concentration.
Column Chromatography
Experimental Procedure. Overview The supernatant from a saturated calcium hydroxide solution is titrated with a standardized hydrochloric acid solution.
Initial HClFinal HCl HCl added Initial NaOH Final NaOH NaOH added Molarity of NaOH 0.00 mL1.10 mL 3.00 mL5.35 mL 0.85 mL 1.10 mL2.10 mL 1.00 mL0.77 mL.
Redox Titration Part 1: To determine the percentage of H 2 O 2 in aqueous solution Part 2: To determine the percentage of ascorbic acid in vitamin C Handout.
Recrystallization Lab # 2.
Experimental Procedure. Overview The pH meter is used in conjunction with a titration apparatus and a standardized sodium hydroxide solution to determine.
Titration and Buffers Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
HCl (aq) + NaOH (aq)  NaCl (aq) + H2O (l)
Acid/Base Titration Thurston High School Chemistry.
A buret is used to deliver solution in precisely-measured, variable volumes. Burets are used primarily for titration, to deliver one reactant until the.
Volumetric Analysis Topic 8.4 Titration readings in a normal titration you are usually advised to carry out at least one rough and two accurate.
Experimental Procedure Lab 406. Overview A known mass of starting material is used to synthesize the potassium alum. The synthesis requires the careful.
Section 8.4 – pg  Experimental designs discussed so far have been QUALitative (flame test, solution colour, litmus test, conductivity, solubility)
Overview Crystalline aspirin is synthesized and then purified by the procedure of recrystallization. The melting point and the percent purity of the aspirin.
Experiment 5. A Rate Law and Activation Energy
Experiment 8. Thermodynamics of the Dissolution of Borax
Lab Instructions. Materials and Equipment Distilled Water Zinc metal Filter Paper Plastic Wash Bottle Copper II sulfate Tap water Pencil (not a pen) Plastic.
Valdosta State University Experiment 5 NaOH Standardization Valdosta State University.
General chemistry Lab 2. Chemistry Analytical Chemistry Gravimetric Analysis Oxidation and Reduction Reactions Oxidation and Reduction Reactions Instrumental.
Introduction The Equipment The Terms The Process Calculations
Preparing Solutions.
Exp. 10 Vinegar Analysis: Acid-Base Titrations Purpose – To use quantitative analysis and titrations to find the concentration of an acid or base. In this.
Titration Analysis.
Introduction to Titration Go to browse and set to full screen.
Experiment: Solutions Preparation, Part 1 1CHE116.
General Laboratory Techniques Dry Lab Chemistry 1105.
枣庄学院化学化工与材料科学学院 Preparation of Solution. 枣庄学院化学化工与材料科学学院 1. Grasp the basic Method and Operation of Preparing Solution 2. Study the Method of Use about.
Lab 24Date: Acids, Bases and Indicators…oh my! Purpose Background Observe a neutralization rxn & work with indicators. Bases will turn red litmus blue.
Trinity College Dublin, The University of Dublin Titration Demonstration.
Practical Analytical Chemistry (1) Practical (8) Faculty of Pharmacy Department of Pharmaceutical Chemistry.
Identification of Substances by Physical Properties.
Walk-In Take out notebook, folder, pencil box.
How much acid is there in a solution
Law ManWai(09) Lai MeiLing(28) Mo WanI(32)
Lab Techniques How to do a Titration.
Determining the Acidity of Soda… An Acid Base Titration
Gel Electrophoresis Teacher Instructions BioRad Set Up 12 groups
Analysis of vinegar via titration
Acid Base Titration.
Determination of Absolute Zero using Vernier Equipment
Introduction to Titration
Laboratory Techniques: Titration
Acid/Base Titration Purpose- to find the concentration of four HCl samples, by titrating them with 0.100M NaOH Solution(titrant).
Procedures Reading from the text.
Revised 1/08, RJE.
Presentation transcript:

Experimental Procedure Experiment 7. Aspirin Analysis: Melting point, Titration, and 1H NMR Spectra (2nd Week) Experimental Procedure

PART B. Melting Point of the Aspirin Sample (Vernier Melt Station)

Example Procedure for Computer-Based Data Collection Obtain and wear goggles. Check the control dial on the Melt Station to confirm that it is in the Off position. Connect the Melt Station power supply to a powered electrical outlet. Connect the Melt Station sensor cable to a LabQuest or computer interface. Obtain a small amount of a solid organic compound. The solid should be in powder form. If it is not, use a mortar and pestle to carefully grind the solid to a powder.

5. Prepare a sample for melting. Pack a capillary tube 3–4 mm (~1/8 inch) deep with your sample by inserting the open end into a small pile of the solid. A small amount of the solid will be pushed up into the tube. Wipe off any loose solid that is on the outside of the capillary tube. Tap the closed end of the capillary tube on the desk top to compress the sample into the closed end. (optional) To further pack down the sample in the tube, drop the capillary tube (closed end down) down a section of glass tubing that has been set up for this purpose. Carefully insert the capillary tube of solid into one of the three slots in the heating block of the Melt Station. You may rotate the Melt Station toward you slightly for a better look at the heating block. Rotate the Melt Station up or down slightly to get the best view of the solid sample through the viewing lens.

6. Start the data-collection program, and then choose New from the File menu. You are now set up to take melting temperature data for up to 20 minutes. 7. In the first trial, you will want to observe the melting process and make a rough estimate of the melting temperature of your sample. Do not worry if the heating rate is a bit too rapid, and the sample melts too quickly. To do this: Start data collection. On the Melt Station, turn the control knob to a setting of 180ºC. The red light will turn on indicating active heating. Carefully observe your sample. If the solid begins to melt, click Mark to mark the temperature on your graph (or press the D key on the computer.) When the entire solid has completely melted, click Mark again. The two values marked on your graph describe the estimated melting temperature range of your substance.

If the solid does not melt by the time the temperature gets to 150ºC, turn the control knob to the 220ºC setting. Continue observing your sample, and if the sample begins to melt, mark the temperatures on the graph as previously described. If the sample has not melted by the time the temperature gets to 190ºC, turn the knob to the Rapid Heat setting. When the sample finally begins to melt, mark the graph as previously indicated. When you have determined the approximate melting temperature range for the sample, stop data collection. Store the run by tapping the File Cabinet icon in LabQuest, or choosing Store Latest Run from the Experiment menu in Logger Pro. Discard the capillary tube and sample as directed by your instructor. On the Melt Station, turn the control knob to the Fan/Cooling setting to get ready for the next trial. The blue light will turn on indicating that the fan is cooling the Melt Station.

8. Now that you have a rough idea of the melting temperature, a more accurate determination can be made. Prepare a new sample in a capillary tube, as described in Step 5, to determine the melting temperature. Start data collection. On the Melt Station, turn the control knob to the Rapid Heat setting. Carefully observe the temperature vs. time graph. When the temperature is within approximately 10ºC of the lowest possible melting temperature of your sample, turn the control knob to a temperature setting corresponding to your expected melting temperature. Carefully observe your sample. When the solid begins to melt, click Mark to mark the temperature on your graph. When the entire solid has completely melted, click Mark again. The two values marked on your graph describe the estimated melting temperature range of your substance. When you are finished with this step, stop data collection. Store the run. Discard the capillary tube and sample as directed by your instructor. On the Melt Station, turn the control knob to the Fan/Cooling setting to get ready for the next trial.

9. At the end of the experiment, record the melting temperature range and turn the control knob on the Melt Station to Off. 10. Complete the Data Analysis section before exiting Logger Pro or the LabQuest App. Print a copy of your graph and/or save your data, as directed by your instructor.

PART C. Percent Acetylsalicylic acid in the Aspirin Sample

Three trials are to be completed in the analysis of the aspirin Three trials are to be completed in the analysis of the aspirin. Prepare three clean 250-mL Erlenmeyer flasks and determine the mass of three aspirin samples while occupying the balance. Obtain a 50-mL buret. Prepare the aspirin sample for analysis. Assuming 100% purity of your aspirin sample, calculate the mass of aspirin that requires 20 mL of 0.1 M NaOH to reach the stoichiometric point. Weighing paper, measure the calculated mass (±0.001 g) of the aspirin you have just prepared and transfer it to the flask. Add 10 mL of 95% ethanol, followed by about 50 mL of deionized water, and swirl to dissolve the aspirin. Add 2 drops of phenolphthalein indicator. Repeat for trials 2 and 3.

2. Prepare the buret for titration 2. Prepare the buret for titration. Prepare a clean buret, rinse, and fill it with a standardized 0.1 M NaOH solution. Be sure that no air bubbles are present in the buret tip. After 10-15 seconds, read and record the volume, and the actual molar concentration of the NaOH solution. 3. Titrate the sample. Slowly add the NaOH solution from the buret to the dissolved aspirin sample until the endpoint is reached. The endpoint in the titration should be within one-half drop of a faint pink color. The color should persist for 30 seconds. Read and record the final volume of NaOH in the buret.

PART D. Observation of 1H NMR Spectra by Using a Benchtop NMR Spectrometer (Spinsolve)

Prepare and load a sample Put sample in tube Put the samples in a standard 5 mm diameter NMR tube at least 7 inches long. The fill height must be at least 30 mm from the bottom of the tube. This is about 0.5 mL in volume. 2. Put tube in tube holder Insert the sample tube into the top of the sample holder and push it all the way down. You may have to pull it from the bottom. Be careful not to pull too far: the cap can come off inside the holder.

The correct position should measure 145 mm from the base of the plastic holder to the base of the sample tube.

3. Check sample level Put the sample tube and holder into the supplied Spinsolve sample depth gauge. Press the sample holder down firmly to ensure it sits on top of the sample gauge. Put the bottom of the sample tube into the rounded base of the gauge. Ensure the top of the sample liquid is above the black marker line on the gauge.

Left: empty sample depth gauge. Middle: holder too high in gauge. Right: sample holder correct.

Left: empty gauge. Middle: sample holder in gauge but not in rounded base. Right: gauge with sample holder in rounded base and liquid above marker.

4. Put tube and holder into spinsolve Put the sample holder and tube into the sample bore of the Spinsolve. Let the sample holder drop straight down in the centre of the bore. If it does not drop down completed by it self you can push it gently.

Do not break the sample tube. Take care when pushing it into the bore. Note: Pushing on an angle will break the tube. Do not break the sample tube. Take care when pushing it into the bore.

Run a protocol Select [STANDARDSCAN:1MINUTE]. Press the green START button. Check progress of scan. Use Mnova software for visualization, processing, analysis and reporting of the 1-D NMR spectrum (consult your TA for details).

DISPOSAL Discard the solution in the Waste Organic Solvent container.