The Inter-American Metrology System (SIM) Common-View GPS Comparison Network Michael A. Lombardi and Andrew N. Novick National Institute of Standards and.

Slides:



Advertisements
Similar presentations
Lecture 1: Logical, Physical & Casual Time (Part 2) Anish Arora CSE 763.
Advertisements

CENAMEP AIP: Time and Frequency Laboratory current status Raul Fernando Solis Betancur Queretaro, 2012.
Reporting Measurement Uncertainties According to the ISO Guide Duane Deardorff Dept. of Physics and Astronomy The University of North Carolina at Chapel.
Use of Kalman filters in time and frequency analysis John Davis 1st May 2011.
Judah Levine, Pulsar-Timing-2005: 1 Coordinated Universal Time (UTC) Judah Levine JILA –- Time and Frequency Div. NIST and Univ. of Colorado Boulder, Colorado.
CMCs and the BIPM Key Comparison Database Raul Fernando Solís Betancur 2012.
Primary and Derived Measures Terminology Prioritization 1.
CMCs and the BIPM Key Comparison Database Raul Fernando Solís Betancur 2015.
QARTOD 2: Remote Currents Working Group Definitions: Level 1 – refers to radials Level 2 – refers to total vectors Level 3 – refers to higher level data.
Common-View Measurements, the SIM Time Network (SIMTN), and Contributing to Coordinated Universal Time (UTC) Michael Lombardi Chair, SIM Time and Frequency.
1 Time Scales Virtual Clocks and Algorithms Ricardo José de Carvalho National Observatory Time Service Division February 06, 2008.
Principles of Time Scales
International Comparisons of Network Time Protocol Servers Michael A. Lombardi, NIST, USA, Judah Levine, NIST, USA J. Mauricio Lopez.
Discussion Topics For SIM Time and Frequency Metrology Working Group SIM Time and Frequency Metrology Working Group Workshop and Planning Meeting Panama.
V-1 Common-View LORAN-C for Precision Time and Frequency Recovery Tom Celano, Timing Solutions Corp LT Kevin Carroll, USCG Loran Support Unit Michael Lombardi,
SVY 207: Lecture 4 GPS Description and Signal Structure
The Global Positioning System (GPS) and Common-View Time Transfer
Error Analysis Accuracy Closeness to the true value Measurement Accuracy – determines the closeness of the measured value to the true value Instrument.
Global Positioning System (GPS). n 24 satellite constellation u Semi-synchronous, circular orbits (~20,200 km/10,900 nautical miles altitude) u Six orbital.
Effects of ionospheric small- scale structures on GNSS G. WAUTELET Royal Meteorological Institute of Belgium Ionospheric Radio Systems & Techniques (IRST)
Modern Navigation Thomas Herring MW 11:00-12:30 Room A
NGS GPS ORBIT DETERMINATION Positioning America for the Future NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION National Ocean Service National Geodetic.
Judah Levine, NIST, CENAM, Sept 2012: 1 Introduction to Time and Timekeeping Judah Levine Time and Frequency Division NIST/Boulder
10/7/ Innovative Solutions International Satellite Navigation Division ION NTM 01 Capabilities of the WAAS and EGNOS For Time Transfer SBAS, an Alternate.
BSJ National Time Realization. Background The Bureau of Standards, Jamaica embarked on a Time and Frequency Program Its aim was to establish a national.
Traceability and Legal Metrology
How Does GPS Work ?. Objectives To Describe: The 3 components of the Global Positioning System How position is obtaining from a radio timing signal Obtaining.
IGS Workshop 2008 The Galileo Ground Mission Segment Performances Francisco Amarillo-Fernandez, Massimo Crisci, Alexandre Ballereau John Dow, Martin Hollreiser,
Network Computing Laboratory Radio Interferometric Geolocation Miklos Maroti, Peter Volgesi, Sebestyen Dora Branislav Kusy, Gyorgy Balogh, Andras Nadas.
Lecturer: Jinglin Wang Student name: Hao Li Student ID:
OAS SIM Project July 2005-November 2006 SIM GA Ottawa September 2007.
Time and Frequency activities at CENAMEP Panama, 2015.
Parallel and Distributed Simulation Synchronizing Wallclock Time.
J. Mauricio Lopez R. 1, Michael A. Lombardi 2, N. Diaz-Mu ñ oz 1 and Eduardo de Carlos Lopez 1 1 Centro Nacional de Metrología (CENAM), Querétaro, Mexico.
Claudinei Rodrigues de Aguiar Federal University of Technology - Parana Paulo de Oliveira Camargo São Paulo State University.
Distributing UTC(NIST) to Industrial Time and Frequency Users Michael Lombardi NIST Time and Frequency Division Distributing UTC(NIST) to Industrial Time.
CGSIC Timing Subcommittee March 11, 2004 USNO Report U.S. Naval Observatory Washington, DC Francine Vannicola
1 Timing with loran Judah Levine Time and Frequency Division NIST/Boulder (303)
Calibration of geodetic (dual frequency) GPS receivers Implications for TAI and for the IGS G. Petit.
GSI Japan - 21st of June 1999 GPS-Positioning using Virtual Reference Stations - Theory, Analysis and Applications Herbert Landau Spectra Precision Terrasat.
APPLICATION OF GPS TECHNOLOGY TO ARCHAEOLOGY GROUP PROJECT.
POOLED DATA DISTRIBUTIONS GRAPHICAL AND STATISTICAL TOOLS FOR EXAMINING COMPARISON REFERENCE VALUES Alan Steele, Ken Hill, and Rob Douglas National Research.
Lecture 5 – Differential Correction
January 14, 2003GPS Meteorology Workshop1 Information from a Numerical Weather Model for Improving Atmosphere Delay Estimation in Geodesy Arthur Niell.
M. Gende, C. Brunini Universidad Nacional de La Plata, Argentina. Improving Single Frequency Positioning Using SIRGAS Ionospheric Products.
2010 SIM TFWG Workshop and Planning Meeting, Lima, Peru March 9-12, 2010 The SIM Time Network and its role in the time and frequency laboratory Michael.
ICALEPCS 2005 Geneva, Oct. 12 The ALMA Telescope Control SystemA. Farris The ALMA Telescope Control System Allen Farris Ralph Marson Jeff Kern National.
The SIM Network: Improved Time Coordination for North, Central, and South America Michael A. Lombardi National Institute of Standards and Technology (NIST),
1 Module One: Measurements and Uncertainties No measurement can perfectly determine the value of the quantity being measured. The uncertainty of a measurement.
1 SVY 207: Lecture 12 Modes of GPS Positioning Aim of this lecture: –To review and compare methods of static positioning, and introduce methods for kinematic.
Principles of the Global Positioning System Lecture 09 Prof. Thomas Herring Room A;
Kenneth Johnston US Naval Observatory Presented by Jules McNeff International Committee on GNSS Provider’s Forum Bangalore, India 4 September 2007 GPS.
GPS ANTENNA CALIBRATION AT THE NATIONAL GEODETIC SURVEY Dr. Gerald L. Mader Geosciences Research Division National Geodetic Survey, NOS/NOAA Silver Spring,
1 Chapter 01 Measurement And Error. 2 Summary Instrument – a device or mechanism used to determine the present value of a quantity Measurement – a process.
2006 NCSL International Workshop and Symposium August 07 Management of the AC-DC voltage transfer difference comparison in the SIM region Sara Campos CENAM.
Scenario use cases Szymon Mueller PSNC. Agenda 1.General description of experiment use case. 2.Detailed description of use cases: 1.Preparation for observation.
Vladimír Smotlacha, CESNET Alexander Kuna, IPE Time and Frequency Transfer in All-optical Network TNC 2011 Prague 17 May 2011.
The Use of GPS Disciplined Oscillators as Primary Frequency Standards for Calibration Laboratories NCSLI – August 2008 Michael Lombardi National Institute.
Calibration Techniques for Stopwatches and Timers
GPS receiver calibration: a tutorial Michael Wouters, NMIA Bruce Warrington, NMIA.
CSIR National Metrology Laboratory Your measurement technology partner for global competitiveness.
The SIMT Time Scale J. Mauricio López R. Centro Nacional de Metrologia, CENAM, El Marques, Qro. Mexico.
4 August An Interlaboratory Comparison of 3.5 mm Coaxial 2-Port Vector Network Analyzer Measurements 4 August 2008 Li Pi Su, Dexter Shelton, George.
MECH 373 Instrumentation and Measurements
Measurement Uncertainty and Traceability
NTP Clock Discipline Modelling and Analysis
Introduction to Electrical Measurement
CORS-Based Coordinate System WHAT IS CORS
Primary and Derived Measures Terminology Prioritization
Presentation transcript:

The Inter-American Metrology System (SIM) Common-View GPS Comparison Network Michael A. Lombardi and Andrew N. Novick National Institute of Standards and Technology (NIST) Boulder, Colorado, United States Jose Mauricio Lopez Centro Nacional de Metrología (CENAM) Querétaro, Mexico Jean-Simon Boulanger and Raymond Pelletier National Research Council (NRC) Ottawa, Canada I. Introduction II. Description of Measurement System III. System Calibration IV. Common-View Data Reduction V. Measurement Results VI. Uncertainty Analysis VII. Summary SIM is the Sistema Interamericano de Metrologia, or the Inter-American Metrology System. It consists of national metrology institutes (NMIs) located in 34 countries in North, Central, and South America. At present, thirteen SIM nations are members of the BIPM’s Metre Convention, and at least ten operate national laboratories that maintain time and frequency standards. To advance the state of metrology throughout the SIM region, we have developed a common-view GPS comparison network that is capable of automating continuous, near real-time comparisons between the national time and frequency standards located at SIM NMIs. This paper describes the common-view network, and presents the results of comparisons between the national time scales located at the Centro Nacional de Metrologia (CENAM) in Queretaro, Mexico, the National Research Council (NRC) in Ottawa, and Canada, and the National Institute of Standards and Technology (NIST) in Boulder, Colorado, in the United States. Type A and B uncertainties have been evaluated as prescribed in the ISO GUM. The time deviation, σ x ( τ), is used as the Type A uncertainty U a. Type B uncertainties are summarized in the table and combined using the square root of the sum of the squares method to produce U b. The combined expanded uncertainty U c is estimated (where k is the coverage area) as I.SIM Baselines in the NORAMET Region BaselineLengthUsable DataData Lost Calibration6 m minNone CNM/NIST km8 100 min22 % NRC/NIST km8 200 min21 % NRC/CNM km7 600 min27 % Systems are calibrated for 10 d at NIST using the same antenna and cable that will be shipped to the SIM laboratory. Method of calibration is short-baseline common-view, using UTC(NIST) as a common-clock. Baseline length is 6 meters, coordinates are surveyed to an estimated uncertainty of 20 cm. The time stability, σ x ( τ), is typically near 0.2 ns at τ = 1 day. Continuous measurements between CENAM, NRC, and NIST began in early June Results below compare SIM links to links between common-view receivers that submit data to the BIPM. Green diamonds show results from the BIPM Circular-T, calculated at 5 d intervals. I.SIM Nations Belonging to the II.Metre Convention Country Member or Associate? Maintains Time and Frequency Standards? Contributes to UTC? ArgentinaMemberYes BrazilMemberYes CanadaMemberYes ChileMemberYes Costa RicaAssociateYesNo Dominican Republic MemberUnknownNo EcuadorAssociateYesNo JamaicaAssociateYesNo MexicoMemberYes PanamaAssociateYes United States MemberYes UruguayMemberUnknownNo VenezuelaMemberUnknownNo 8-channel GPS receiver with standard L1 carrier frequency antenna. Time interval counter with 30 ps resolution that accepts a 5 or 10 MHz external time base. Stores 10 min and 1 min averages from all satellites in view. Does not follow any tracking schedule, but 1 min data can be converted to the BIPM format. Uploads data via Internet FTP every 10 min to a web server. Software records measurements and other system parameters including temperature. Common-view data reduction is done “on-the-fly” in near real- time. Requests for measurement data are processed instantly from any Java-enabled web browser. The “pure” common-view method is now supported, but support for the “all-in-view” method can be easily added to the web software. Web-based software produces: 10 min, 1 hour, and 1 d averages for intervals as long as 200 days. Graphs of 1 hour or 1 day data. Fast calculations of Allan deviation and time deviation. Near real-time grid that shows results from the most recent 10 minute comparison. The Phase and stability of the SIM links agree well with corresponding BIPM links. Time offset between SIM and BIPM links falls within the coverage area of estimated measurement uncertainties as discussed in Section VI. SIM system collects about min of data per day at each site with no dead time or gaps between measurements, as compared to 624 min collected by single-channel BIPM submission receivers. SIM data and BIPM submission data apply modeled ionospheric corrections (MDIO), Circular-T data has the measured ionospheric (MSIO) corrections applied. As expected, BIPM submission data correlates very strongly to the Circular-T data. The SIM common-view GPS comparison network began operation at three NORAMET NMIs in June Measurement results agree well with BIPM submission links, but the SIM results have the distinct advantage of being available in near real-time. Future work will focus on increasing the number of participating labs, reducing the measurement uncertainties, exploring the use of the “all-in-view” method, and perhaps the eventual creation of a UTC(SIM) time scale. I.Results from NORAMET Baselines BaselineMean Offset Between Links σ x (τ) at 1 dσ y (τ) at 1 d SIMBIPMSIMBIPM CNM/NIST2.3 ns1.2 ns 2.4E-142.5E-14 NRC/NIST7.2 ns1.5 ns1.1 ns3.1E-142.2E-14 NRC/CNM13.0 ns2.1 ns1.9 ns4.3E-143.8E-14 I.Type B Time Uncertainties ComponentExplanation Estimated Uncertainty Delay calibration errors Short-baseline common-clock calibrations are not exactly repeatable and can introduce systematic errors due to seasonal delay variations and differences between the multipath environment at the calibration site and the measurement site. 5 ns Ionospheric Delay Errors SIM common-view system does not apply MSIO corrections. 3 ns Antenna Coordinates Error Assumes that antenna position (x, y, z) is known to within 1 m. 3 ns Time interval counter The absolute accuracy of the SIM system counter is near 2 ns. 2 ns Environmental variations Receiver delays can change due to temperature or voltage fluctuations from power supplies, antenna cable delays can change due to temperature. 2 ns Estimate of D REF This is generally done with time interval counter and is subject to errors near 2 ns. 2 ns Resolution Uncertainty SIM software allows delay values to only be entered with 1 ns resolution. 0.5 ns For k = 2 coverage, U c is nearly identical for all three baselines: 15.0 ns for CNM/NIST comparison ns for NRC/NIST comparison ns for CNM/NRC comparison. The differences between the SIM and BIPM submission links fall well within the coverage areas of these uncertainties.