Area Problems You have 20” of string; figure the square area of: – A 5 X 5” square – A 4 X 6” rectangle – A 6.66 “ X 3.33” X 5.76” right triangle – A circle.

Slides:



Advertisements
Similar presentations
EVERYTHING YOU WANTED TO KNOW BUT WERE AFRAID TO ASK!!!!
Advertisements

Ch. 14 Four Radiographic Qualities Ch
Chapter 11 Prime Factors.
Electric Field Strength. EFS (by definition)  The electric field strength, E, is the force, F elec, per unit charge, q, at a point. The equation for.
Quality Control in Diagnostic Radiology
E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
Analyzing the Image Density. Density Overall blackening of the image.
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
CVT 102.  Time  Distance  Shielding.
Technical Artifacts and Errors
Basic quality control tests in medical radiography
Factors affecting the X-Ray output
X-Ray Production & Emission
X-Ray Production & Emission
1.7: Find Perimeter, Circumference, and Area
Introduction to Fluoroscopy & Radiation Safety
Example 1: Effects of Changing One Dimension
Quiz-Warm Up! Remember 5 minutes only!
P RIMARY E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Quality Control.
Northern California SGNA Meeting September 22, 2012.
RAD 354 Chapt. 11 Control of Scatter Break down into: Those that reduce pt. dose and those that are geometrical in nature and those NOT! 3 factors affecting.
What is the inverse Square Law Formula? I2I2 I1I1 = (D 1 ) 2 (D 2 ) 2 Next hint.
INVERSE SQUARE LAW. The picture above demonstrates the typical x-ray tube used to produce a point source of x-rays. Then as radiation exits the tube it.
Equipment Design for Radiation Protection
Resident Physics Lectures
Introduction to Perimeter, Circumference and Area
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
Factors affecting CT image RAD
Exposure Factors or Prime Factors
FIND THE AREA OF A RECTANGLE THROUGH MULTIPLICATION OF THE SIDE LENGTHS MATH UNIT 4 LESSON 8.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
1.7 Perimeter, Circumference, & Area
Definition: Rectangle A rectangle is a quadrilateral with four right angles.
Worktext p. 181 Worktext p ___ units × ___ units = ___ square units 1 6 units
PRINCIPLES OF TECHNIQUE AND EXPOSURE
5-Minute Check Name a quadrilateral that has opposite sides parallel and 4 right angles. Name a quadrilateral that has exactly 1 pair of parallel sides.
RAD 354 Chapt. 8 X-ray emission
RAD 354 Chap. 13 Radiographic Technique
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
Chapter 10 Exposure Mathematics. Exposure Mathematics u We have seen in Chapter Seven that there are several exposure factors that are predetermined before.
P5 – Space for reflection Lesson 1 – circular motion.
Newton’s Law of Universal Gravitation
1.7 Perimeter, Area, & Circumference HMWK: pp. 55 – 57, #s 15 – 29 odd, 40 – 46 even Game Plan: Today I will be able to … Calculate area, perimeter, &
How many …?. What shape can you see? I can see some _____. Q1 Q1 stars.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
 Make and type of x-ray machine  Incoming line voltage  Kilovoltage  Milliamperage and exposure time  Focal film distance/source-imagine distance.
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
Exposure Factors or Prime Factors
Lesson 29 Area of a Combined Figure. Get the Idea Sometimes, you need to find the area of a figure that is not a common shape. You can often do this by.
EVERYTHING YOU WANTED TO KNOW BUT WERE AFRAID TO ASK!!!!
Chapters 21 & 22.
Direct Proportions (field sizes, collimator changes, film, transformer turns ratios, etc) If you had a 10 X 12” col. Size at 36”, what would the size be.
Step Two: Using your circles and squares, line up your shapes to show a one-to-one relationship. Cut shapes when necessary. Glue them onto your paper.
Perimeter and Area Word Problems (Using One Variable) Taught by the Bestest of all the besterest who are not bestless, Mr. Peter Richard.
Stacy Kopso, M.Ed., RT(R)(M)
Factors Effecting the Production
Class Greeting.
Shapes.
Lesson – Teacher Notes Standard: 7.G.A.1
SPLITTING OF COMBINED SHAPES
1. How many matchsticks would be used to make figure 10?
Area of combined figures
Radiation at a Distance
Can you work out the next shape in the pattern?
4.2 Graphing a Function Rule HW: 4.2
Can you work out the next shape in the pattern?
Presentation transcript:

Area Problems You have 20” of string; figure the square area of: – A 5 X 5” square – A 4 X 6” rectangle – A 6.66 “ X 3.33” X 5.76” right triangle – A circle with a periphery of 20” (R= 3.183”)

Steps Draw the DAMN picture! Write the equation Fill in the knowns and unknowns on the picture Work the problem Re-read the question to see if you did what it asked Do a “quick mental check”

Problems If you had collimator settings of 8 X 10” at 40” SID, what would the resultant field size be at 50” SID if NO changes in collimator settings were done (direct proportion)? If you were in fluoro and standing 24” away from the fluoro tube and received a dose of 20mR, what dose would you receive at 48” (inverse square law)?

More problems If you were doing a PCXR and used 10 mAs and 80 kVp at an SID of 40”, what distance would receive only 2.5 mAs (inv. sq. law)? If you had a great technique for a CXR of 115 kVp and 10 mAs at 40: SID, what mAs would you need to use at 80” SID to get the SAME radiographic density (Old mAs/New mAs)?

No more clues! You did a PCSR yesterday using 10 mAs, 70 40” SID. Today, you can only get a 50” SID. What technique would give you the same radiographic density as yesterday’s? You received a dose of 2Ft. From the fluoro table in 5 minutes. How far away would you need to stand to only receive 2.5 mR in 5 minutes?

Con’t A man was stabbed with a 4” blade. The blade shows up as 6” long on the image SID. How far away from the film/receptor is the blade? You totaled 182 pts. Of 200 possible in this class, what is your percentage of the total pts?

More You used sec with 70 kVp, but got motion on the image. What new time can you use to lesson motion if you now use 500 mA? If you had a great SID with 6 mAs/70kVp, but could only get a 50”SID on a follow up, what new mAs would you use?

Ditto If you were receiving 4 R/min. during 20” from the fluoro table, how far away would you need to stand to only receive 2 R/min? An x-ray unit puts out 80 40” SID. How far away from the same unit with the same factors would receive only 20mR?

Double ditto A portable machine exposure is 20 40” SID. What is the new exposure at 80 SID (w/o technique changes)? You are using a technique of 20 mAs and 70 kVp. You must double your exposure density, but you have exceeded tube limits. What should you do to be able to make a more dense OD, but NOT exceed tube limits?