10th Trento Workshop on Radiation Detectors HVCMOS Sensors for LHC Upgrade Felix Michael Ehrler, Robert Eber Daniel Münstermann, Branislav Ristic, Mathieu.

Slides:



Advertisements
Similar presentations
Ivan Peric, HV-CLICPIX measurements Chip-Top ATLAS Type A (as in CCPDv2 and v1) with the preamplifier made entirely of enclosed T and linear long feedback.
Advertisements

Studies and status of CMOS-based sensors research and development for ATLAS strip detector upgrade 1 Vitaliy Fadeyev, Zach Galloway, Herve Grabas, Alexander.
Snowmass 2005 SOI detector R&D Massimo Caccia, Antonio Bulgheroni Univ. dell’Insubria / INFN Milano (Italy) M. Jastrzab, M. Koziel, W. Kucewicz, H. Niemiec.
Chronopixel R&D status – May 2014 N. B. Sinev University of Oregon, Eugene In collaboration with J.E.Brau, D.M.Strom (University of Oregon, Eugene, OR),
Development of HV CMOS sensors for 3D integration
Ivan Peric, Monolithic Detectors for Strip Region 1 CMOS periphery.
Ivan Peric, WIT Active Pixel Sensors in high-voltage CMOS technologies for ATLAS Ivan Perić University of Heidelberg, Germany.
Ivan Perić University of Heidelberg, Germany
Overview of HV/HR-CMOS Pixel Sensors
SPiDeR  First beam test results of the FORTIS sensor FORTIS 4T MAPS Deep PWell Testbeam results CHERWELL Summary J.J. Velthuis.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
CLICPix/CCPD/Mu3e (HVCMOS)
Background Issues: Real Time Radiation Measurement S.M.Yang EPC.IHEP Mini-Workshop on BEPCII Background Study March 2008 Institute of High Energy.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Pierpaolo Valerio.  CLICpix is a hybrid pixel detector to be used as the CLIC vertex detector  Main features: ◦ small pixel pitch (25 μm), ◦ Simultaneous.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
2. Super KEKB Meeting, DEPFET Electronics DEPFET Readout and Control Electronics Ivan Peric, Peter Fischer, Christian Kreidl Heidelberg University.
Medipix sensors included in MP wafers 2 To achieve good spatial resolution through efficient charge collection: Produced by Micron Semiconductor on n-in-p.
VI th INTERNATIONAL MEETING ON FRONT END ELECTRONICS, Perugia, Italy A. Dorokhov, IPHC, Strasbourg, France 1 NMOS-based high gain amplifier for MAPS Andrei.
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
1 An introduction to radiation hard Monolithic Active Pixel Sensors Or: A tool to measure Secondary Vertices Dennis Doering*, Goethe University Frankfurt.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Specifications & motivation 2  Lowering integration time would significantly reduce background  Lowering power would significantly reduce material budget.
LEPSI ir e s MIMOSA 13 Minimum Ionising particle Metal Oxyde Semi-conductor Active pixel sensor GSI Meeting, Darmstadt Sébastien HEINI 10/03/2005.
IWLC 2010 – Ivan Peric 1 Particle pixel detectors in high-voltage CMOS technology Ivan Peric University of Heidelberg.
Foundry Characteristics
Update on Micron productions - Comparison of AC & DC coupled devices - Marko Milovanovic*, Phil Allport, Gianluigi Casse, Sergey Burdin, Paul Dervan, Ilya.
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Ivan Peric, CLIC Workshop HVCMOS for CLICPix V2.
1 Radiation Hardness of Monolithic Active Pixel Sensors Dennis Doering, Goethe-University Frankfurt am Main on behalf of the CBM-MVD-Collaboration Outline.
PHASE-1B ACTIVITIES L. Demaria – INFN Torino. Introduction  The inner layer of the Phase 1 Pixel detector is exposed to very high level of irradiation.
Effects of long term annealing in p-type strip detectors irradiated with neutrons to Φ eq =1·10 16 cm -2, investigated by Edge-TCT V. Cindro 1, G. Kramberger.
Update on Simulation and Sensor procurement for CLICPix prototypes Mathieu Benoit.
AMS HVCMOS status Raimon Casanova Mohr 14/05/2015.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
Technology Overview or Challenges of Future High Energy Particle Detection Tomasz Hemperek
65 nm CMOS analog front-end for pixel detectors at the HL-LHC
A. Rivetti Villa Olmo, 7/10/2009 Lepix: monolithic detectors for particle tracking in standard very deep submicron CMOS technologies. A. RIVETTI I.N.F.N.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
Experiment Electronics UMC 0.18µm radiation hardness studies Progress since last Collaboration Meeting Sven Löchner GSI Darmstadt 15 th CBM Collaboration.
9 th “Trento” Workshop on Advanced Silicon Radiation Detectors Genova, February 26-28, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
CERN Detector Seminar 1 CMOS sensors Ivan Perić. CERN Detector Seminar 2 Introduction.
CMOS MAPS with pixel level sparsification and time stamping capabilities for applications at the ILC Gianluca Traversi 1,2
Gossip/GridPix – guidelines, facts, and questions for review Version 1: Norbert Version 2: Tatsuo Version 3: Werner.
LHCb Vertex Detector and Beetle Chip
W. Kucewicz a, A. A.Bulgheroni b, M. Caccia b, P. Grabiec c, J. Marczewski c, H.Niemiec a a AGH-Univ. of Science and Technology, Al. Mickiewicza 30,
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
Ideas for Super LHC tracking upgrades 3/11/04 Marc Weber We have been thinking and meeting to discuss SLHC tracking R&D for a while… Agenda  Introduction:
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
Ivan Peric, 2nd CHIPP Workshop on Detector R&D 1 High-Voltage CMOS Technology Ivan Peric University of Heidelberg, Germany.
L. Ratti a,b, M. Dellagiovanna a, L. Gaioni a,b, M. Manghisoni b,c, V. Re b,c, G. Traversi b,c, S. Bettarini d,e, F. Morsani e, G. Rizzo d,e a Università.
Ideas on MAPS design for ATLAS ITk. HV-MAPS challenges Fast signal Good signal over noise ratio (S/N). Radiation tolerance (various fluences) Resolution.
Hybrid CMOS strip detectors J. Dopke for the ATLAS strip CMOS group UK community meeting on CMOS sensors for particle tracking , Cosenors House,
Comparison of the AC and DC coupled pixels sensors read out with FE-I4 electronics Gianluigi Casse*, Marko Milovanovic, Paul Dervan, Ilya Tsurin 22/06/20161.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1,Gregor Kramberger 1, Marko.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1, Marko Zavrtanik 1,
Pixel Sensors for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
Clear Performance and Demonstration of a novel Clear Concept for DEPFET Active Pixel Sensors Stefan Rummel Max-Planck-Institut für Physik – Halbleiterlabor.
TCT measurements of HV-CMOS test structures irradiated with neutrons I. Mandić 1, G. Kramberger 1, V. Cindro 1, A. Gorišek 1, B. Hiti 1, M. Mikuž 1,2,
ASICs1 Drain Current Digitizer Chip (DCD) Status and Future Plans.
Ivan Peric, Christian Kreidl, Peter Fischer University of Heidelberg
HEC I chip design Short summary (J.Bán).
Charge sensitive amplifier
HV-MAPS Designs and Results I
Ivan Peric for ATLAS and CLIC HVCMOS R&D and Mu3e Collaborations
HVCMOS Detectors – Overview
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Presentation transcript:

10th Trento Workshop on Radiation Detectors HVCMOS Sensors for LHC Upgrade Felix Michael Ehrler, Robert Eber Daniel Münstermann, Branislav Ristic, Mathieu Benoit, Javier Bilbao De Mendizabal, Sergio Gonzalez Sevilla, Didier Ferrere, Ivan Peric for HVCMOS collaborations 1

10th Trento Workshop on Radiation Detectors Introduction HVCMOS detectors are depleted active segmented detectors implemented in a CMOS process The sensor element is an n-well diode in a p-type substrate The electronics is placed inside the n-well sensor electrode. High voltage is used to deplete a part of the substrate. The main charge collection mechanism is drift of the charge signal from the depleted region 2 NMOSPMOS HVCMOS N-well P-substrate Depleted

10th Trento Workshop on Radiation Detectors Applications We are developing HVCMOS sensors for the following experiments: ATLAS pixels, strips (ATLAS, CMS), CLIC, Mu3e 3

10th Trento Workshop on Radiation Detectors Substrate resistivity HVCMOS can be implemented in standard CMOS technologies These technologies have substrate resistances of 10 to 20 Ωcm. The HVCMOS structure can be improved by taking a substrate of higher resistance (for instance 100 – 1000 Ωcm) instead of the standard one. (Non-standard CMOS process) The transistors will be not affected since they are placed in n-wells and not is in the substrate itself 4 Deep-n-well +- Deep-n-well +- Particle

10th Trento Workshop on Radiation Detectors Sensor architectures - monolithic Depending on proposed application we have several sensor architectures. For Mu3e and strips we have the monolithic sensors. Active pixels contain usually only the analog circuits like the charge sensitive amplifier. The pixels are connected to the readout cells placed at the chip periphery. Every pixel has its readout cell. These RO cells do zero-suppression and generate hit-addresses. RO-cells contain hit buffers (Mu3e) of hit multiplexer (strips) Instead of analog pixels we are investigating the use the pixels with comparators that generate pixel addresses and transmit the addresses to the periphery. 5 Row/Col Addr + TS One RO cell /pixel Pixel contains a charge sensitive amplifier CSA

10th Trento Workshop on Radiation Detectors Sensor architectures - hybrid For ATLAS pixels and CLIC we propose the smart sensor concept We use the existing readout chips (FEI4 in the case of ATLAS and CLIC-pix in the case of CLIC) for the readout of HVCMOS sensors. Advantages in comparison with the standard hybrid sensors: The signal transmission between sensor- and readout chip can be done capacitively, without bumps Capacitively coupled pixel detectors - CCPD Another advantage can be increased spatial resolution. Many smaller pixels can be coupled to one channel of the readout chip 6 + TOT = sub pixel address Readout pixel Size: 50 µm x 250 µm Size: 33 µm x 125 µm Different pulse shapes

10th Trento Workshop on Radiation Detectors 350nm and 180nm technologies We have started HVCMOS developments in AMS H35 (350nm) technology Since 2011 we investigate also AMS H18 (180nm) because this technology allows smaller pixels and potentially better radiation tolerance of transistors For certain applications - like large area strip sensors - H35 technology has some advantages: Cheaper production and better standard substrate. (20 Ωcm instead of 10 Ωcm) In 2015 we are planning at least two engineering runs: H35, for large pixels and strips and H18 for small pixels. Within these runs we will implement sensors on various substrates. 7

10th Trento Workshop on Radiation Detectors Collaborations The development of HVCMOS sensors is done within following collaborations Mu3e collaboration (Heidelberg, PSI, KIT, University and ETH Zuerich) ATLAS pixel HVCMOS collaboration (subset of the larger ATLAS CMOS collaboration) ATLAS Strip CMOS collaboration and KIT CLIC detector R&D group 8

10th Trento Workshop on Radiation Detectors HVCMOS pixels for strip layers in 350nm technology - experimental results 9

10th Trento Workshop on Radiation Detectors Test chip for strip layers HVStrip Measurements on CMOS strip test chip implemented in AMS 350nm technology - HVStripV1 Pixel detector with long pixels. Pixel signals are transferred to the periphery where zero suppression and hit-address generation is done. We have not done efficiency measurement yet. We expect similar results as in the case of H18 detectors (see later) Here shown: Tests of radiation tolerance of the H35 technology at KIT, Karlsruhe 10

10th Trento Workshop on Radiation Detectors Single transistor measurements Ids vs Vgs characteristics of a PMOS transistor, before irradiation, after a dose of 60Mrad (X-ray irradiation) and after irradiation with protons (at KIT) to n eq (probably 600 MRad) The PMOS transistors are radiation tolerant (no leakage current) 11

10th Trento Workshop on Radiation Detectors Single transistor measurements Ids vs Vgs characteristics of a standard linear NMOS. The NMOS has a leakage current of about 100nA after 60Mrad. This leakage current is not large and in most cases will not cause a problem (analog circuits). The measurement has been done after annealing – leakage current was larger in the dose range 1-10MRad (without annealing) 12

10th Trento Workshop on Radiation Detectors Single transistor measurements Ids vs Vgs characteristics of a enclosed NMOS. This device is radiation tolerant – no leakage current 13

10th Trento Workshop on Radiation Detectors Nonionizing irradiation effects in sensor We have also investigated the influence of irradiation to sensor diode. Results after irradiation with protons n eq. Increased noise at room temperature. Test diode of the same size as the pixel diode for leakage current measurements. Leakage current increased after irradiation. Leakage current causes noise – this effect is well known and can be seen in simulation. Leakage current can be decreased by cooling to about 1nA at -30C – exponential dependence (Temperature of the chip not precisely known) 14

10th Trento Workshop on Radiation Detectors Nonionizing irradiation effects in sensor Before irradiation the beta signal (Sr90) was about 2300e. The result was obtained by comparing the amplitudes in the case of strontium illumination with the amplitudes we obtain when the illuminate the sensor with x-rays from different targets mV ~ 2300e Calibration with x-raysStrontium-90 illumination – spectrum Not irradiated A/D units

10th Trento Workshop on Radiation Detectors Nonionizing irradiation effects in sensor After irradiation with protons n eq the strontium signal is higher – it is up to 3800e. This result was confirmed with a new calibration. Similar result has been measured in 2010 Signal to noise ratio measured with injection circuit is about mV A/D units Strontium-90 illumination – spectrum irradiated Strontium-90 illumination – spectrum irradiated Old measurement on “capsens” detector

10th Trento Workshop on Radiation Detectors HVCMOS pixels for ATLAS in 180nm technology - experimental results 17

10th Trento Workshop on Radiation Detectors CCPD test-chips We present here HVCMOS detector-prototype for ATLAS pixels that has been implemented in H18 AMS technology Smart sensor readout by FEI4 – bumpless signal transmission CCPD The latest test chip is rather small – it contains several small pixel matrices with pixels of different types. 18 CCPDv1CCPDv2CCPDv3CCPDv4 4mm

10th Trento Workshop on Radiation Detectors The main pixel type employs the pixels with discriminators. Three pixels are grouped and coupled to one FEI4 channel. Digital comparator outputs are transmitted capacitively to the readout chip. We have also a smaller pixel matrix with analog pixels that do not have comparators TOT = sub pixel address Readout pixel Size: 50 µm x 250 µm Size: 33 µm x 125 µm Different pulse shapes

10th Trento Workshop on Radiation Detectors Test beam results University of Geneva group has done a test beam measurement in November % detection efficiency with the latest prototype (left). (Pixels with comparators.) The measurement has been done under suboptimal conditions – the bias voltage was only 12V. 20

10th Trento Workshop on Radiation Detectors Test beam results Several chips irradiated with neutrons at Jozef Stefan institute in Ljubljana. Detection efficiency with an irradiated chip (fluence n eq ) 96% (right) Bias voltage was reduced – 35V 21

10th Trento Workshop on Radiation Detectors Efficiency of irradiated detector The efficiency increases when we increase the high voltage bias. Due to a damage it was not possible to increase the bias more than 35V 22

10th Trento Workshop on Radiation Detectors There are several possibilities to improve the signal to noise ratio One is to examine which structure limits the bias voltage to ~80V. This is probably the guard ring around the N-wells. This guard ring is too close to the n-well and is in present designs shorted with the bias. We will leave it floating on the next test chip. We hope in this way to increase the maximum bias voltage, which should improve signal. Another possibility is to use high resistive substrates – we are planning an engineering run in H18 technology with this detector design. The capacitive signal transmission works well!! 23

10th Trento Workshop on Radiation Detectors Time resolution Still not satisfactory: Time resolution was about 100ns – we need 25ns This time uncertainty is mostly caused by the time walk effect The problem is that the preamplifier is designed to have a peaking time > 100ns. The peaking time can be adjusted – in the test beam measurement the slow setting was used. Using of long peaking time allows us to operate the detector in low-power mode – long peaking time reduces noise for an equal bias current (power). However if the signal spread is large (landau distribution, we will have a time walk – time skew. 24 TW Tpeak Th Sig

10th Trento Workshop on Radiation Detectors There are a few way to improve time resolution One is to make the amplifier faster. This is possible, however it increases the noise. If we make amplifier faster we will probably need to increase the signal – which can be done by using high resistive substrate. More elegant way to improve the timing - compensation Bases of the fact that the time walk is proportional to the signal amplitude 25

10th Trento Workshop on Radiation Detectors Several pixels with analog output – the signal they produce in FEI4 is proportional to the input charge signal. If we plot the arrival time vs the TOT (charge amplitude) we see a clear dependence. This means for certain amplitude the time walk is smaller that when we consider all the amplitudes. It is of the order of 50ns. This means that if we use the amplitude information we can correct for time walk ns all amplitudes 50ns one amplitude +

10th Trento Workshop on Radiation Detectors Time walk compensation 27

10th Trento Workshop on Radiation Detectors We have implemented on the test chip a time walk compensating comparator. Its rise time is longer for signal with high amplitudes. This means a signal with higher amplitude has a faster threshold crossing, but the comparator output is slower. A signal with lower amplitude has a later threshold crossing but the comparator output is faster. As consequence of this the comparator outputs for all amplitudes can cross in one point. By adding another comparator we can make the response time independent of amplitude. 28 Slow down Higher amplitude Lower amplitude 2

10th Trento Workshop on Radiation Detectors We have implemented on the test chip a time walk compensating comparator. Its rise time is longer for signal with high amplitudes. This means a signal with higher amplitude has a faster threshold crossing, but the comparator output is slower. A signal with lower amplitude has a later threshold crossing but the comparator output is faster. As consequence of this the comparator outputs for all amplitudes can cross in one point. By adding another comparator we can make the response time independent of amplitude. 29

10th Trento Workshop on Radiation Detectors Finally I will mention the development for CLIC. We have here 25 x 25um pixels on HVCMOS. The sensor is capacitivelly coupled to the CLIC pix ASIC. Test beam has been done – the detection efficiency is better than 99%. The pixels on the CLIC HVCMOS contain only amplifiers – the output is analog. Similar results are achieved with Mu3e sensors as well. 30

10th Trento Workshop on Radiation Detectors Summary We are developing sensors for LHC strips, pixels CLIC and Mu3e We have the following structures: CCPD for ATLAS pixels - the HVCMOS sensor is readout by FEI4 chip Monolithic sensors for ATLAS (or CMS) strips and Mu3e – the readout parts are on the periphery of the sensor chip CCPD with small pixels for CLIC We measure 99% efficiency for ATLAS pixels, CLIC, Mu3e. The strip detectors will be tested soon After irradiation n eq we measure efficiency of >95% (preliminary, suboptimal settings) We are planning engineering runs in AMS H35 and H18 technologies that will bring us the possibility to test different substrate resistances and improve SNR For the strip project we are using H35 technology For the pixel project we are using both technologies: for inner pixels H18 and for outer pixels H35 Irradiation results on H35 test detector have been shown Enclosed NMOS and PMOS transistors are radiation tolerant – no leakage current after irradiation with x-rays (60MRad) and with protons (2 x n eq ) We measure increased beta-particle signal (Sr-90) after irradiation with protons (2 x n eq ) The signal is 3800e 31

10th Trento Workshop on Radiation Detectors Thank you 32