Vital Signs for Vital Organs™ Non-Invasive Blood Flow Measurements Using Ultrasound Modulated Diffused Light N. Racheli a, A. Ron a, Y. Metzger a, I. Breskin.

Slides:



Advertisements
Similar presentations
Foundations of Medical Ultrasonic Imaging
Advertisements

Temporal-Spectral Imaging of Functional States Randall L. Barbour NIRx Medical Technologies LLC SUNY Downstate Medical Center 4 th NIH Optical Imaging.
Tae Sun Yoo Department of Medical Biophysics University of Western Ontario Supervisor: Dr. Keith St Lawrence and Ph.D. candidate Jonathan Elliott.
إعداد : أ. بلسم فهد صوفي 1 Ultrasound in Medicine Ch.3 Ultrasound pictures of the body.
EE 5340, SMU Electrical Engineering Department, © Carlos E. Davila, Electrical Engineering Dept. Southern Methodist University slides can be viewed.
Validation of predicted path of thermally deflected ultrasonic waves (phD work on acoustic thermometry in SFR) Nicolas Massacret (PhD Student ) Directors:
Lecture 10. The time-dependent transport equation Spatial photon gradient Photons scattered to direction ŝ' Absorbed photons Photons scattered into direction.
高等輸送二 — 質傳 Lecture 7 Fundamentals of Mass Transfer
Chapter 5 Part Three Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
TeraHertz Kerr effect in GaP crystal
OEIC LAB National Cheng Kung University 1 Ching-Ting Lee Institute of Microelectronics, Department of Electrical Engineering, National Cheng Kung University.
Automated Method for Doppler Echocardiography Analysis in Patients with Atrial Fibrillation O. Shechner H. Greenspan M. Scheinowitz The Department of Biomedical.
Resonant Faraday Rotation in a Hot Lithium Vapor Scott Waitukaitis University of Arizona, Department of Physics May 2007.
Mechanical and fluidic integration of scintillating microfluidic channels into detector system 1 Davy Brouzet 10 th September 2014.
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
By: Katie Lawton, RN, SNNP July 7, 2014 GRNS 5632.
Body Composition Techniques 2
New developments in cerebral monitoring Tariq Alzahrani Demonstrator College of Medicine King Saud University.
Ultrasonography.
A statistical model in detecting small blood vessels with Power Doppler Imaging Department of Medical Biophysics 07/04/10.
Biomedical Engineering Overview
Measurements with the KSTAR Beam Emission Spectroscopy diagnostic system Máté Lampert Wigner Research Centre for Physics Hungarian Academy of Sciences.
Vladislav Toronov, Ph. D. Using Physics to Image Brain Function.
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
AUTOANALYZER T. Elsarnagawy 22/12/ Elsarnagawy, MASH
Resident Categorical Course
By P. Vainshtein and M. Shapiro Technion - Israel Institute of Technology Faculty of Mechanical Engineering An acoustic channel for aerosol particle focusing.
Equations Speckle contrast : K(T) = σ s / Decay rate of autocorrelation: g(T) = / Critical decay time: τ 0 = g(e -1 sec) Relative velocity:v = x/ τ 0 Algorithms.
A Novel Dermoscopic Probe for Determining Elasticity Measurements of the Skin Erica Bozeman 1, Markesha Cook 1, Stephanie Cruz 1 Advisor: Michael Miga,
Sino-German-Workshop, Oct , Shanghai, China 1 New possibilities for velocity measurements in metallic melts S. Eckert, G. Gerbeth, F. Stefani.
Multi Frequency Laser Driver for Near Infrared Optical Spectroscopy in Biomedical Application Chenpeng Mu Department of Electrical and Computer Engineering,
RITRIT Biomedical Engineering Department of Chemical and Biomedical Engineering Kate Gleason College of Engineering Rochester Institute of Technology.
Display of Motion & Doppler Ultrasound
Introduction to the Physics Echocardiography Introduction to the Physics Echocardiography Jose L. Rivera, M.D. January 9, 2010.
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
Michal Tepper Under the supervision of Prof. Israel Gannot.
Sowmya Vasa, Umar Alqasemi, Aditya Bhargava. Objectives This paper aims in bringing out a novel light microscopy method called Focal Modulation Microscopy.
Laser Treated Metallic Probes for Cancer Treatment in MRI Systems July 08, Advance Materials Processing and Analysis Center (AMPAC) Department of.
A neuroimaging technique (like a CT scan) that uses magnetic fields and radio waves to vibrate atoms in the brain’s neurons to produce and image of the.
Saudi Board of Radiology: Physics Refresher Course Kostas Chantziantoniou, MSc 2, DABR Head, Imaging Physics Section King Faisal Specialist Hospital &
Detecting Cerebral Autoregulation Thresholds Using a Noninvasive Cerebral Flow Monitor Introduction Cerebral autoregulation (CA) refers to brain’s vasculature.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
A 5-Pulse Sequence for Harmonic and Sub-Harmonic Imaging
Design and Implementation of a Smartphone-Based portable Ultrasound Pulsed-Wave Doppler device for blood flow measurement Huang, C. C., Lee, P. Y., Chen,
Image Compression in Optical Coherence Tomography Biomedical Engineering, Tambov State Technical University, Russia K.E.S.Ghaleb, A.Yu.Potlov, S.N.Abdulkareem,
Distributions of plasma parameters and observation of intermittency in edge plasma of SUNIST W H Wang, Y X He, and SUNIST Team Department of Engineering.
Blood Flow Detection > by the Doppler principle > by Electromagnetic principles © D. J. McMahon 2014 rev
N. Kuo, H.J. Kang, T. DeJournett, J. Spicer, and E. Boctor Proc. SPIE 7964, (2011); doi: / Photoacoustic Imaging of Prostate Brachytherapy.
Date of download: 7/3/2016 Copyright © 2016 SPIE. All rights reserved. Static autoregulation. The classic static autoregulation curve shows a plateau of.
Date of download: 7/6/2016 Copyright © 2016 SPIE. All rights reserved. (a) Responsivity phantom. (b) Setup to measure the diffuse transmittance factor.
Saturation Roi Levy. Motivation To show the deference between linear and non linear spectroscopy To understand how saturation spectroscopy is been applied.
ISMS 2017 at CHAMPAIGN-URBANA, ILLINOIS
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
Lecture on Ultrasonography
Carbon monoxide reduces near-infrared spectroscopy determined “total” hemoglobin: a human volunteer study Near-infrared spectroscopy determined brain and.
Technological Principles of Medical Instrumentation
Lecture 10 Technological Principles of Medical Instrumentation
Optical Coherence Tomography
Physiologic signals Lecture 5.
Spatially Varying Frequency Compounding of Ultrasound Images
Photo acoustic tomography
Establishing Patterns Correlation from Time Lapse Seismic
OPTICAL MONITORING OF PHOTOSENSITIZER DIFFUSION INTO TISSUE
P07021: Instrument to Detect Thromboemboli
Fluid distribution in a rough fracture
COLOR MAPPING OF ONE SPECIFIC VELOCITY OF A FLOW WITH COMPLEX GEOMETRY USING OPTICAL COHERENCE TOMOGRAPHY Potlov A.Yu, Frolov S.V., Proskurin S.G. Biomedical.
Denys W.1, Moerman A.1, De Somer F.2, Wouters P.1, De Hert S.1
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Functional Neuroimaging: a window on the working human brain
Photothermal spectroscopy Rotem Neeman & Yonat Milstein
Presentation transcript:

Vital Signs for Vital Organs™ Non-Invasive Blood Flow Measurements Using Ultrasound Modulated Diffused Light N. Racheli a, A. Ron a, Y. Metzger a, I. Breskin a, G. Enden b, M. Balberg a, R. Shechter a a Ornim Medical Ltd, Israel b Biomedical Engineering Department, Ben- Gurion University, Israel

Outline Background Phantom Setup Data analysis and Results In vivo evaluation Conclusions Future work

Ornim’s Regional Oximeter and Flowmeter Monitor Two Probes (multi-use) Single use adhesive pad Bed Side Monitor Cerebral & Tissue Oximeter – measures brain and muscle underneath the sensor Flow and oxygen saturation monitoring- simultaneously Two probes – independent readings Single use adhesive

Background Ornim’s patented technology utilizes principles of the acousto-optic effect The medium is irradiated with NIR coherent light Light is modulated in the tissue by a coded ultrasound series with a narrow autocorrelation: G(t): a series comprising of “1” and ” -1” bits, bit length = 4μ sec. f = 1MHz.

Background The detected light I(t) is correlated with the ultrasound series g(t):

Background

Background The amplitude of the UTL curve is proportional to: Photons’ density Ultrasound field Decorrelation time Movement of scatterers affects the amplitude of the cross correlation Flow Values [A.U]

Experimental setup Phantom Syringe pump Reservoir Tissue mimicking phantom with micro channels simulates small blood vessels Generate flow at the range of 0 to 2.5 mm/sec Deliver coherent light and Ultrasound into the phantom Record and analyze the light signal Fluid: 70% purified H 2 O; 10% Glycerol; 20% Spherotech Inc Polystyrene spheres, µm (5% W/V)

Data Analysis and Results Extracting the Flow Index ( CFI ) from the UTL curve N K

Data Analysis and Results The amplitude of the UTL curve decreases as flow through the channels increases CFI is linear as a function of the flow velocity Sensitivity to flow in deep channels is lower but measurable R 2 =0.97 R 2 =0.99 R 2 =0.90

Data Analysis and Results The effect of scatterers concentration was tested Diluted the original liquid from 1% to 0.66% of Polystyrene spheres (W/V) The CFI is linear as a function of the normalized velocity values R 2 =0.87

In vivo Evaluation Preclinical model – piglets Comparison to a commercial, invasive, Laser Doppler (LD) Moor Instrument DRT4, with DP3b probe Manipulations Flow increase - Epinephrine Flow decrease -Nitropruside/hyperventilation/occlusion

In vivo Evaluation CFI Laser Doppler Epinephrine Nitropruside Hyperventilation11 Epinephrine Injection Nitropruside Injection ROC analysis - AUC Hyperventilation

Cerox 3210F- Oxygen saturation and blood flow Combined display of saturation and flow per channel Saturation Flow Blood occlusionExercise Saturation

Conclusions A novel method for continuously and non invasively measuring flow in deep tissue based on ultrasound modulated diffused light was presented Data demonstrates a linear correlation of CFI to flow in channels deeper than 1cm in a synthetic phantom A very good in vivo correlation to Laser Doppler readings was demonstrated

Future Work Clinical studies – cerebral flow monitoring during surgeries Calibrate CFI Numerical model

Vital Signs for Vital Organs™ THANK YOU Vital Signs for Vital Organs™