FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter.

Slides:



Advertisements
Similar presentations
NEWTONIAN MECHANICS. Kinematic equations Frictional Force.
Advertisements

Short-range, high-LET recoil tracks in CR-39 plastic nuclear track detector E. R. Benton 1, C. E. Johnson 1, J. DeWitt 1, N. Yasuda 2, and E. V. Benton.
Beam Composition for Biology
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Preliminary studies for T2 primary target for the NA61 fragmentation beam run 11 th October 2010 – NA61 Collaboration Meeting M. Calviani on behalf of.
Tenth lecture Last lecture.
MURI Neutron-Induced Multiple-Bit Upset Alan D. Tipton 1, Jonathan A. Pellish 1, Patrick R. Fleming 1, Ronald D. Schrimpf.
Study of plastic scintillators for fast neutron measurements
Radiation Detectors / Particle Detectors
AP Physics Mr. Jean March 30 th, The plan: Review of slit patterns & interference of light particles. Quest Assignment #2 Polarizer More interference.
Optics 1. 2 The electromagnetic spectrum Visible light make up only a small part of the entire spectrum of electromagnetic waves. Unlike sound waves and.
LIGHT A FORM OF ELECTROMAGNETIC RADIATION THAT STIMULATES THE EYE.
1 Fundamentals of Microelectronics  CH1 Why Microelectronics?  CH2 Basic Physics of Semiconductors  CH3 Diode Circuits  CH4 Physics of Bipolar Transistors.
Update on Self Pinch Transport of Heavy Ion Beams for Chamber Transport D. V. Rose, D. R. Welch, Mission Research Corp. S. S. Yu, Lawrence Berkeley National.
LHCf: a LHC Detector for Astroparticle Physics LHCf: a LHC Detector for Astroparticle Physics Lorenzo Bonechi on behalf of the LHCf Collaboration * University.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Tumour Therapy with Particle Beams Claus Grupen University of Siegen, Germany [physics/ ] Phy 224B Chapter 20: Applications of Nuclear Physics 24.
Photon and Energy Fluence
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Lawrence Pinsky Physics Department University of Houston
LBNE R&D Briefing May 12, 2014 LBNE R&D Briefing May 12, 2014 LArIAT and LBNE Jim Stewart LArIAT EPAG Chair BNL LBNE LARIAT-EPAG J. Stewart BNL T. Junk.
Nuclear Tracks Sup. P.J.Apel 4/4/  A solid-state nuclear track detector or SSNTD (also known as an etched track detector or a dielectric track.
P. Scampoli - 24th ICNTS Bologna, September 4,
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Physics Modern Lab1 Electromagnetic interactions Energy loss due to collisions –An important fact: electron mass = 511 keV /c2, proton mass = 940.
Radius To use a Compton polarimeter, the possible range of the backscattered photons’ energy should be calculated. Applying the laws of conservation of.
ARDENT Advanced Radiation Dosimetry European Network Training initiative WP1: Gas Detectors S. Rollet.
11/12/2015NASA-JSC and DIAS1 Study of Sensitivity Fading of CR-39 Detectors during Long Time Exposure D. Zhou a, b, D. O’Sullivan c, E. Semones a, N. Zapp.
Special Relativity & Radiative Processes. Special Relativity Special Relativity is a theory describing the motion of particles and fields at any speed.
Energy calibration of the threshold of Medipix for ATLAS Céline Lebel Université de Montréal presenting for the Institut of Experimental.
1 dE/dx  Let’s next turn our attention to how charged particles lose energy in matter  To start with we’ll consider only heavy charged particles like.
Monte Carlo methods in ADS experiments Study for state exam 2008 Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Electrons Electrons lose energy primarily through ionization and radiation Bhabha (e+e-→e+e-) and Moller (e-e-→e-e-) scattering also contribute When the.
Radiation Detectors In particular, Silicon Microstrip Detectors by Dr. Darrel Smith.
FLUKA Meeting--INFN-Milan July 9, 2010 – L. Pinsky Houston FLUKA Activity Update 1 Toni Empl, Brandon Reddell, Nic Stoffel & Lawrence Pinsky University.
Detector Monte-Carlo ● Goal: Develop software tools to: – Model detector performance – Study background issues – Calculate event rates – Determine feasibility.
Applications of Monte Carlo Code for a Gamma Resonance System Analysis L. Wielopolski, A. Hanson, I. Dioszegi, M. Todosow, Brookhaven National Laboratory,
SS Space Science MO&DA Programs - August Page 1 ACE Instrument Status Report Cosmic Ray Isotope Spectrometer (CRIS) Normal Operation. Electron Proton.
1 Performance of a Magnetised Scintillating Detector for a Neutrino Factory Scoping Study Meeting Rutherford Appleton Lab Tuesday 25 th April 2006 M. Ellis.
Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector J. M. DeWitt 1, E. R. Benton 1, Y.
The Use of Accelerator Beams for Calibration and Characterization of Solid State Nuclear Track Detectors Eric Benton Department of Physics Oklahoma State.
Observation of latent image specks in nuclear emulsion for the purpose of precise estimation of local deposit energy Kimio Niwa* Toshiyuki Toshito** Ken'ichi.
Determining Radiation Intensity
NE Introduction to Nuclear Science Spring 2012 Classroom Session 4: Radioactive Decay Types Radioactive Decay and Growth Isotopes and Decay Diagrams.
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Workshop On Nuclear Data for Advanced Reactor Technologies, ICTP , A. Borella1 Monte Carlo methods.
Collection of Photoelectrons from a CsI Photocathode in Triple GEM Detectors C. Woody B.Azmuon 1, A Caccavano 1, Z.Citron 2, M.Durham 2, T.Hemmick 2, J.Kamin.
J. Alozy, S. George, F.Murtas, M. Silari 1 CERN GEMPIX detectors as hadron therapy beam monitors and radioactive waste detectors GEMPIX construction.
Radiation study of the TPC electronics Georgios Tsiledakis, GSI.
Metal micro-detector TimePix imaging synchrotron radiation beams at the ESRF Bio-Medical Beamline ID17 Andrii Chaus Institute for Nuclear Research National.
Marina Golubeva, Alexander Ivashkin Institute for Nuclear Research RAS, Moscow AGeV simulations with Geant4 and Shield Geant4 with Dpmjet-2.5 interface.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
Ali Ahmad FLUKA code validation of nuclear data required for the spallation target design in Accelerator Driven Subcritical Reactors ThorEA Meeting – Daresbury.
Achim Stahl RWTH Aachen Hadron Therapy, Jülich Oct, Workshop Nuclear Models for Use in Hadron Therapy October 8./ Achim Stahl – RWTH Aachen.
KISTI 2013 달 토양에서 지하 깊이에 따른 고에너지 우주선 환경 영향 분석 Jongdae Sohn, Yu Yi Dept. of Astronomy & Space Science, Chungnam National University.
Louisiana State University Radiation Safety Office
The BLAIRR Irradiation Facility Hybrid Spallation Target Optimization
INTERACTION OF PARTICLES WITH MATTER
BoNuS: Radial-Drift TPC using Curved GEMs
Interactions of Radiation With Matter
Lunar Reconnaissance Orbiter CRaTER Critical Design Review
N. Stoffle University of Houston
Arghya Chattaraj, T. Palani Selvam, D. Datta
Gamma-ray Albedo of the Moon Igor V. Moskalenko (Stanford) & Troy A
Physics Processes Missing from our Current Simulation Tools
CRaTER Science Requirements
Development of a Large Area Gamma-ray Detector
PHYS 3446 – Lecture #14 Wednesday,March 7, 2012 Dr. Brandt
Semiconductor Physics
Presentation transcript:

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 1 Adding Dose Equivalent Scoring for Heavy Ions in FLUKA Toni Empl & Lawrence Pinsky University of Houston

Current NASA Funding Status Dose Equivalent ScoringWe have a specific grant from NASA/JSC to add Dose Equivalent Scoring into FLUKA (to support Toni through July). Kerry Lee and Neal Zapp continue to use FLUKA for operational calculations. AdvancedFLUKA CourseNASA is interested in having an “Advanced” FLUKA Course at some point in the not too distant future. No word yet on possible extensions to validate codes for Light Fragments… Medipix (Si Charge Cluster) SimulationFunding to add a “Medipix (Si Charge Cluster) Simulation” to FLUKA is pending… Tom Wilson has a proposal in to fund the use of FLUKA to model Lunar habitats and potential Lunar-based experiments FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 2

Dose Equivalent for Heavy Ions Much of the effort has been done for protons and can be directly implemented for Heavy ions (We will use the NCRP 132 Q Factors)… Scoring at an interface is less problematic than within a volume, (except for neutrals). Principal Issues: –Neutrons (Multi-Group—Kerma)… –Double counting energetic  -rays… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 3

Neutron Issues When a (multi-group) neutron is propagating in a medium the Kerma is normally scored and the neutron’s group is changed. Scoring Dose Equivalent properly, one should propagate the neutron in detail and account for the energy deposits via any produced charged particles from interactions, much like a . This is problematic at surfaces. Proposed Solution: Update Kerma tables in FLUKA to account for the Oxygen in Water, using a water equivalent scoring. FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 4

LET ∞ Issues & Double Counting The NCRP definition of Dose Equivalent for Heavy Ions employs an LET ∞ –based formula. If one uses the actual Net Energy Lost by the particle over its track-length in a volume to be scored, and in addition propagates the long range  -rays does one count the deposition from them in addition to the energy lost by the primary, both when the d-ray remains entirely within that volume, and when it leaves the volume for an neighboring volume to be separately scored? The same issue occurs for gamma’s produced. A biological argument would be to score both… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 5

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 6 Recent Efforts in the Development of a TimePix-Based Active Dosimeter for Use in the Space Radiation Environment Lawrence Pinsky (& Others) University of Houston

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 7 A Report on the HIMAC In February, 2009

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 8 NIRS in Japan HIMAC - (Heavy Ion Medical Accelerator NIRS (National Institute for Radiological Sciences) in Chiba, Japan. Primarily a Cancer Therapy Center, but they give us free beam time

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 9 HIMAC Layout

Some “Standard” HIMAC Beams FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 10 The Numbers in BLACK are the dE/dx values in Si, and the “*” are Non-Standard Beams. The Numbers in RED are the maximum kinematically allowed  -Ray energies.

Measuring Charge AND Energy If you know  then measuring the charge is reasonably simple because of the Z 2 dependence. In accelerator experiments the interaction fragments from the projectile particle is generally moving at close to the projectile’s original velocity, at least for forward fragments. However, if you have no a priori velocity information, the problem is the BETHE- BLOCH Equation… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 11 All charge-1 particles. Higher charge particles are raised by the square of the charge at the same momenta

Same dE/dx, BUT, Different Z FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 12 Remember, these dE/dx values are from the Bethe-Bloch Equation!

dE/dx vs. Energy Deposited FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter MeV/A Si 600 MeV/A Si 100 MeV/A O 180 MeV/A Ne

High Energy  -Rays Because the number of  -rays produced per unit track length in the Air prior to entering the Si is much less than in the the Si… …The highest energy  -rays carry away more energy from the Si than enters from the air. HOWEVER—It is the High Energy d-rays that offer the prospect of telling the difference between the different particle velocities with the same dE/dx… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 14 TimePix  -Rays Air Incident Particle

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 15 TimePix in the HIMAC Beams Data were taken in a parasitic mode with 500 MeV/A, 290 & 180 MeV/A and 400 MeV/A The primary beams were: 600 & 800 MeV/A, –Ne at 180 MeV/A and 100 MeV/A, –all at Incident angles of 0 , 15 , 30 , 45 , 60  & 90  …With a TimePix clock of 20 MHz, IKRUM’s of 3, and with a Bias Voltages of 35V

Examples of Individual Tracks FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter MeV/A O 800 MeV/A Si 180 MeV/A Ne The high energy  -rays are clear in the higher energy tracks. These are not yet calibrated, and the study to be preformed is to explore the detailed resolution possible when all the information is included… The next goal is to be able to model these tracks in the FLUKA Monte Carlo code…

The “Volcano” (Plasma) Effect When the ionization creates a charge density that exceeds the doping density it can overwhelm them dielectric capability in the Si detector layer. When that happens the charges “see” each other, and recombination increases considerably… Also, when the track is parallel with respect to the bias field the recombination opportunity is a maximum. This can create a “hole” or dip in the center of the circular drift image, making the “lego-plot” look like a volcano… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 17

Close Up of the “Partial” Event The right-hand event is a “normal” iron event, which does show a clear “Volcano” Effect. The scale is so high that the  -rays are not visible. The left-hand event is a “Partial- Event.” One that was partially cutoff by the “Shutter.” Because the central hole essentially goes to zero, it would appear that this event occurred at the end of the Shutter window and was only the early part of the drift image… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 18

Another view of the Volcano Event… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 19

The Next Steps… The Chip has now been calibrated and absolute analyses in KeV are being started… …And, we will also complete the measurement program at HIMAC… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 20

Using the TimePix to Measure Interaction Cross Sections… There are many heavy ion interaction cross sections that will be needed to verify the existing event generators used to predict doses in astronauts will take on future space missions… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 21

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 22 Pixelman Frames from 11 ~90  From Last Year

Image of Time of Arrival of Charge at the Chip… We can examine the nature of the drift of the charge cloud by using the TDC capability of the TimePix… See separate ABCDView Plot… FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 23

FLUKA Meeting--INFN-Milan April 28, 2009 – L. Pinsky Adding Dose Equivalent Scoring and Recent Efforts in the Development of a TimePix-Based Active Dosimeter 24 Thank You for Your Attention