FDR - NCSX Central Solenoid Support Structure Fred Dahlgren Joe Rushinski 6 Sept 2006.

Slides:



Advertisements
Similar presentations
Topsfield Engineering Service, Inc. Figure 1 Thermoelastic Analysis in Design William Bell & Paul-W. Young Topsfield Engineering Service, Inc. John Stewart,
Advertisements

Testing Test Setup TapLok Insert Shear Key Copper Threads Friction Tests Collar Shear Tests NSTX TF FLAG JOINT REVIEW 8/7/03 Michael Kalish.
Fasteners / Joint Design Michael Kalish NSTX TF FLAG JOINT REVIEW 8/7/03.
Second Peer Review for New MGI Valves for NSTX-U (Update on Valve Testing) R. Raman, et al. October 29,
N. Dhanaraj, Y. Orlov, R. Wands Thermal-Stress Analysis of CC1 Space Frame.
Vacuum Vessel Production Readiness Review
FDR Station 3 lift fixture, laser screens and brackets T. Brown and L. Morris with analysis support from A. Brooks December 3, 2007.
J. H. ChrzanowskiNSTX TF Flag Joint Design Review1 NSTX TF Flag Joint Design Review Fabrication and Assembly April 10, 2003 By: James H. Chrzanowski.
Component Testing Test Setup TapLok Insert Shear Key Copper Threads Friction Tests Collar Shear Tests NSTX TF FLAG JOINT REVIEW 8/7/03 Michael Kalish.
Fasteners / Joint Design Michael Kalish NSTX TF FLAG JOINT REVIEW 4/10/03.
Fasteners / Joint Design Michael Kalish NSTX TF FLAG JOINT REVIEW 8/7/03.
Component Testing Test Setup TapLok Insert Shear Key Copper Threads
1 RF-Structures Mock-Up FEA Assembly Tooling V. Soldatov, F. Rossi, R. Raatikainen
1 THERMAL & MECHANICAL PRELIMINARY ANALYSIS ELM COIL ALTERNATE DESIGN Interim Review July 26-28, 2010 In-Vessel Coil System Interim Review – July 26-28,
NCSX NCSX Planar Coil "ASIPP" Presentation 1 December 8-10, 2005 Michael Kalish NCSX TF and PF Coils.
LARP QXF 150mm Structure Mike Anerella / John Cozzolino / Jesse Schmalzle November 15, nd Joint HiLumi LHC-LARP Annual Meeting.
Multiple Coil Lift Calculation. Purposes of the Study  To investigate the stress distribution in the MCWF and the lifting device.  To make sure mounting.
PDR - NCSX Base Support Structure 6 Mar F.Dahlgren J.Rushinski T.Cruickshank H.M. Fan 1.
Analyses of Bolted Joint for Shear Load with Stainless Steel Bushing and Frictionless Shim-Flange Interface Two cases of shim plates were investigated.
NSTX CSU Preliminary Assessment of PFCs Art Brooks December 8,
NSTX TF Flag Joint Design Review OVERVIEW C Neumeyer 8/7/3.
NCSX Modular Coil Turning Fixture FDR. Background Modular Coil winding forms are cast structures which provide the foundation on which the coils are constructed.
ARIES AT Project Meeting - Princeton, NJ 18 Sept 00 1 ARIES-AT Toroidal Field (TF) and Poloidal Field (PF) Coils Tom Brown, Fred Dahlgren, Phil Heitzenroeder.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus February 24, 2010 PF3 Dome Bracket 1/8 inch Weld Stress PF4,5 Stress with 6 Support.
NSTXU-CALC TF Flex Joint and TF Bundle Stub
1 WBS 1 Design Analysis Status NCSX Analysis Meeting Dec 3, 2003.
Modular Coil Assembly Bolted Joint PDR 2/22/07. Objectives The review objectives include... Define the location of additional inboard bolts Finalize the.
NCSX VACUUM VESSEL PL Goranson Status Report Sept 5, 2006 Support Rod Revision NCSX.
A Review of NCSX Conventional Coil Insulation Stresses Presented by Leonard Myatt.
SC Project Review of NCSX, April 8-10, 2008 NCSX Coil Services P.L. Goranson Work Package 161.
NCSX NCSX PF Coil PDR 12/14/07 1 Len Myatt NCSX PF Coil PDR Joseph Rushinski Michael Kalish Fred Dahlgren.
NCSX A. Brooks, P. Fogarty, G. Lovett, D. Williamson June 3, 2005 Modular Coil Type-C Final Design Review – Part II.
In-Vessel Coil System Conceptual Design Review – September, Vertical Stability Coil Structural Analyses P. Titus, July
NCSX NCSX TF Coil Procurement 1 February 3, 2006 Michael Kalish NCSX TF Coil Procurement.
Magnets and Supports Bob Wands October 20, 2006 PPD/MD/Engineering Analysis Group Fermilab 4 th Concept Detector at Fermilab October, 2006.
NCSX Vacuum Vessel Stress Analysis FDR Fred Dahlgren 17 May 2004.
ITER In-Vessel Coils (IVC) Interim Design Review Thermal Structural FEA of Feeders A Brooks July 27, 2010 July 26-28, 20101ITER_D_353BL2.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus January 27, 2010 Umbrella Leg Sliding Blocks TF OOP Support to the Vessel Seismic (Static.
An Analysis of Shell Structure for Dead Load H.M. Fan PPPL September 16, 2005.
NCSX VACUUM VESSEL HEATING/COOLING PL Goranson Preliminary Results February 17, 2006 MDL Testing of Coolant Tracing NCSX.
Analyses of Bolted Joint for Bolt Preload and Shear Load
56 MHz SRF Cavity Thermal Analysis and Vacuum Chamber Strength C. Pai
Figure 1 – NSTX Upper Umbrella Assembly Upgrade Design: Version 3.
F. Dahlgren -SC Project Review of NCSX, April 8-10, 2008 PF, TF, & Trim Coil Supports (WBS-15) Core Base Support Structure (WBS-17) F. Dahlgren NCSX Coil.
Shear Test Assembly update
1 MC Assembly over the VV FPA Station 3 FDR Review July 13, 2007 T. Brown.
LAT Transport Container1 GLAST LAT Project8 September 2005 LAT Transport Container Design Review 8 September 2005 LAT Transport Container Design Review.
NCSX NCSX Preliminary Design Review1 Conventional Coils and Structure Phil Heitzenroeder, Len Myatt, and Mike Viola for the NCSX Engineering Team.
NSTX TF Flag Joint Design Review SUMMARY C Neumeyer 8/7/3.
BoltJoin ppt P. Rogoff 3/24/2011. NSTX Supported by P. R. 3/9/2011 Update Ring Bolted Joint Design and Recommend the Joint Geometry using bolts.
Spacing of Cu clamp = 10” Clamp plate width = 2.5”, thickness = 0.375” Thickness of conductor insulation = 0.03” Thickness of coil ground wrap = 0.03”
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus March Insulation Short Beam Tests – Failure Modes Ripple Loads on PF PF4/5.
NCSX VACUUM VESSEL PL Goranson Final Design Review November 17, 2005 Man Access Port /Lateral Supports NCSX.
Nonlinear Analyses of Modular Coils and Shell structure for Coil Cool-down and EM Loads Part 1 – Results of Shell Structure and Modular Coils H.M. Fan.
FEM Analysis of the Stage3 Support Frame H.M. Fan March 14, 2007.
AWB NSTX TF Flag Joint Design Review April 10, 2003 Art Brooks.
A View of NCSX Structural System and Load Path for the Base Support Structure.
NCSX NCSX TF Coil Conductor FDR 5/17/05 1 Michael Kalish NCSX TF Conductor.
REQUIREMENTS & ASSUMPTIONS C Neumeyer 4/10/3. FIELD AND CURRENT Base GRD requirement: 3kG at R 0 =0.854m with 4.5 sec flat top, once every 300s
Analysis of TF Load Paths and Vacuum Vessel Loading H. M. Fan Jan. 22, 2009.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus March F.
TS Cool Down Studies TSu Unit Coils (24-25) N. Dhanaraj and E. Voirin Tuesday, 10 March 2015 Reference: Docdb No:
NSTX TF Flag Joint Design Review OVERVIEW C Neumeyer 8/7/3.
704 MHz cavity design based on 704MHZ_v7.stp C. Pai
NSTX Supported by NSTX Centerstack Upgrade Project Meeting
Pipe Integrity Check using Finite Element Analysis
2K Cold Box Structural Analysis
TQS Structure Design and Modeling
SNS PPU Cryomodule Space Frame
SNS PPU Cryomodule Thermal Shield & MLI
Presentation transcript:

FDR - NCSX Central Solenoid Support Structure Fred Dahlgren Joe Rushinski 6 Sept 2006

FDR - Central Solenoid Support Structure - 9/6/06 Charge: Does the coil structure provide adequate support for the PF1a coils with sufficient margins of safety? Have the interfaces with other sub-systems been defined and are they compatible? Are the drawings and supporting documents complete and ready for sign-off? Has the analysis been documented and checked? Are the cost, procurement and assembly schedule consistent with the program schedule and budget?

Design Description: The structure consists of solution annealed 304L stainless weldments fabricated mainly from 1/4”, 3/8”, 1/2” and 3/4” thick plate (µ < 1.02). The individual structural segments are 120 degrees with G-11CR insulating plates, bushings, and washers between the adjacent segments. A mid-plane sub-assembly will space the top & bottom PF1A coils (re- claimed from NSTX), at ± 40 cm from the mid-plane. The top and bottom sub-assemblies will have six 3/4” tie rods with nuts and belleville washers and will provide a 12,000 lb. axial pre-load clamping force on the two PF1A coils. The bellevilles’ will accommodate up to 0.015” of differential thermal contraction/expansion (~ 0.007” amount required). Twelve radial support arms (6-top & 6-bottom) will attach the solenoid structure to the main coil structure. All bolting materials (nuts, bolts, washers, etc.) will be 316 stainless. FDR - Central Solenoid Support Structure - 9/6/06

PF1a Coil Modification: Water fittings & tubes must be re-worked & re- insulated Coil Description: 48 turn double layer spiral wound, 0.787” square CDA107 drawn Cu conductor with dia. coolant hole. Insulation: 0.026” thk. CTD112P w/0.0065” Kapton-1/2-lapped (0.052” turn to turn) & 0.054” thk. ground wrap. Coil Dimensions: 12.8” I.D ” O.D ” axial length 48 turns Cu area: 0.52 sq.in. Hole dia.: 0.354” Leads: 12.6” & 16.9” Fabr. Details see: NSTX-SPEC

FDR - Central Solenoid Support Structure - 9/6/06 PF1a Coil/Structure Assembly - Pre-assembled

FDR - Central Solenoid Support Structure - 9/6/ ”

FDR - Central Solenoid Support Structure - 9/6/06 Assembly will have ~55” clearance for lift

Materials: 304L solution annealed plates ER316LN weld filler 316L nuts, bolts, washers, & rods G10/11CR insulating 120 deg. G10/11CR washers & bushings Copper tubing Brass Swagelok (B-600 series) tube fittings Interfaces: Cryogen cooling lines connect to top & bottom LN2 feed/return lines. Pressure & flow requirements defined, connecting lines (with insulating breaks) to cryogen supply & return plenums are needed. Four thermocouples are required to monitor coil inlet/outlet. Bus pads at the top & bottom locations are defined. Bus connection to power supply are needed. Bus interface defined, scenario A defines the current & voltage requirements. Top & bottom mounting pads bolt to same threaded holes to be used for permanent solenoid supports. support interface defined.

FDR - Central Solenoid Support Structure - 9/6/06 * * From Allegheny Ludlum Technical Data Blue Sheet

2/3rd Yield = 46.6ksi 304L Properties* * From Allegheny Ludlum Technical Data Blue Sheet

FDR - Central Solenoid Support Structure - 9/6/06 Cooling analysis: Cooling Analysis Shows < 1 deg.K rise per pulse & no ratcheting Plot of the PF1a exit temperature vs. time DP = 10 psi Qdot = 1.14 GPM AMPS = 19.3 kA ESW = 0.16 sec. Rep.Rate = 900 sec Ø 0.354

FDR - Central Solenoid Support Structure - 9/6/06 FEA Model of PF1A & Supporting Structure: A 1/6th-Upper half Nastran linear FEA model was used. PF1A coil modeled as discrete turns with insulating layers (CHEXA & CPENTA). Structural components modeled with plate elements (CQUAD4 & CTRIA3). Tie rods modeled with solid elements (CHEXA & CPENTA). Bolts modeled with CBAR elements attaching plates & adjacent weldments. EM loads on PF1A determined from dforce7b (Biot-Savart - U.C. code). Symmetry boundary conditions were applied (toroidal, vertical and rotational). Coil top & bottom surfaces not permitted to slide radially (rel. to supports). Model Summary: Number of GRID Points = Number of CBAR Element= 57 Number of CHEXA Elements= Number of CPENTA Elements= 1696 Number of CQUAD4 Elements = 2287 Number of CTRIA3 Elements= 170 Loading Conditions considered: Gravity, EM, Thermal, Seismic

FDR - Central Solenoid Support Structure - 9/6/06 3/4” Tie Rod / belleville washer, and bolted connection modeled

FDR - Central Solenoid Support Structure - 9/6/06 PF1A Coil Model: CPENTA & CHEXA isotropic Cu & Epoxy Glass

FDR - Central Solenoid Support Structure - 9/6/06 Loads considered: Gravity Loads with 1g & 2g vertical downward, B.C.: Symmetry & fixed at the upper bracket bolts (attached to the inner segmented ring castings which are assumed rigid). Horizontal seismic loading using static 0.15g acceleration per the NCSX/IBC2000 criteria (h~15ft, Fp=0.108 x = ~ 0.15g). B.C.: Symmetry & upper bracket bolts. Thermally induced stress from cool down and temperature differentials using mean CTEs from R.T. to 77 o K. B.C.: Symmetry & upper bracket bolts. (CTE-Cu from NIST data, CTE-304L from ITER data) Electro-magnetic loading for coil day-1 scenario A.1.3.2: I pf1a = 19,299 A & 23,500 A (simulates M.C. loading) I pf4 = 3,141 A I pf6 = 241 A I pl = -26,068 A & 0.0 A(I pl = 0.0 was highest loading) B.C.: Symmetry & upper bracket bolts.

Vertical Displacements for a 1-g gravity: Max = ” FDR - Central Solenoid Support Structure - 9/6/06

Peak Tresca stress - 1-g loading: 3.44 mtg. bolt holes Peak Tresca Stress: 3.44ksi

FDR - Central Solenoid Support Structure - 9/6/06 Vertical Displacements for (fault) 2g loading condition: -.005” max.

FDR - Central Solenoid Support Structure - 9/6/06 Tresca Z2 stress for a 2g loading condition (ie. if bottom supports loose or removed) Max Stress: the mounting bolt holes

Lateral 0.15g seismic displ ” at the middle of the tierod Peak Tresca stress 2 the bolt hole Seismic (static) load 0.15g horizontal acceleration with top mtg. bracket fixed Peak Tresca Stress 2.0ksi FDR - Central Solenoid Support Structure - 9/6/06

Thermal Loading: 80K & R.T.(extreme case) Max Vertical displacement: the top of the coil

FDR - Central Solenoid Support Structure - 9/6/06 Need to avoid extreme thermal differentials during cooldown Peak Tresca Stress 78.6 ksi >> yield stress & allowable

FDR - Central Solenoid Support Structure - 9/6/06 A more realistic thermal loading assumes a temperature difference of 30 K and yields a relative vertical displacement of ”. The differential rod & bellville to top plate shows about 0.005” - just over 50% of it’s linear range. ∂y ~0.005” ∂y (tot.): ”

FDR - Central Solenoid Support Structure - 9/6/06 Peak Tresca stress for a 30 K temperature differential: 15.6 ksi Peak Tresca: 15.6 ksi

FDR - Central Solenoid Support Structure - 9/6/06 Tresca Peak Stress is 4.6 ksi in coil insulation for 30 o K temperature differential

Baseline EM Loads assumed the 0.5T 1st Plasma Scenario Coil EM Loading No Plasma: Fr = 4,369 lbs/in [5,660 lbs/in * ] Fz = -3,722 lbs (total) [-6,355 lbs * ] DFORCE7b result: Hoop Stress(avg.)=1.27ksi [1.84ksi * ] Net Stress = 1.54ksi With I pl = -26,068 amps Fr = 4,318 lbs/in Fz = -3,647 lbs (total) DFORCE7b result: Hoop Stress (avg.)=1.25ksi Net Stress = 1.53ksi *For I pf1a = 23,500 Amps FDR - Central Solenoid Support Structure - 9/6/06

EM Loading was calculated as J x B body forces at each coil turn. Genforce subroutine added to DFORCE7b to generate Nastran Force input. Equivalent discrete forces for the worst cases were applied at each of 6 interior element grid points. Centroidal currents each turn) were assumed. The loading from the M.C. field was simulated by running a 23.5 kA PF1a current case, which duplicates the peak vertical loading from the M.C. radial fields.

FDR - Central Solenoid Support Structure - 9/6/06 Typical EM grid point load 6 interior points in conductor

FDR - Central Solenoid Support Structure - 9/6/06 Coil Displacements (SRSS) From 19.3kA EM Loads - No Axial Pre-load No Plasma -Maximum displacement was ” at the coil mid-plane Peak Displ ”

FDR - Central Solenoid Support Structure - 9/6/06 Peak Tresca stress in the coil from 19.3kA EM loading only: 1.83 ksi Peak Tresca: 1.83ksi

Peak Tresca Stress in supports 19.3kA EM + Thermal (cool-down): 14.0 ksi (with CONROD elements at bolt hole perimeter) FDR - Central Solenoid Support Structure - 9/6/06

Peak Tresca Stress in supports 19.3kA EM + Thermal (cool-down): 2.51 ksi (with MPCs replacing CONROD elements at bolt hole perimeter)

FDR - Central Solenoid Support Structure - 9/6/06 Peak Tresca Stress in Coil for 23.5 kA EM-only loading, 2.78 ksi (Loading includes the effects of the M.C. peak fields) Peak Tresca Stress in Cu 2.78 ksi

FDR - Central Solenoid Support Structure - 9/6/06 Peak Tresca Stress in Support for 23.5 kA EM loading, 3.68 ksi

FDR - Central Solenoid Support Structure - 9/6/06 Peak Tresca Stress in coil insul. for 23.5 kA EM-Cold loading, 3.17 ksi, 2.9 ksi in Cu Peak Tresca Stress: 3.17 ksi Peak Cu Tresca Stress: ~2.9 ksi

FDR - Central Solenoid Support Structure - 9/6/06 Displacements for combined gravity, thermal, EM loading Peak Displ ” (SRSS)

FDR - Central Solenoid Support Structure - 9/6/06 Tresca stress in coil from combined gravity, thermal, and EM loading Peak Tresca Stress = 3.16 ksi - insulation Average coil Tresca stress ~2-3ksi

FDR - Central Solenoid Support Structure - 9/6/06 Peak Tresca Stress 2.68 ksi Peak Stress in supports from combined gravity, thermal, and EM load

*Allowable 80 o K = 46.6 ksi (321 MPa) (2/3 rd yield criteria) Allowable CDA107(10%CW) 80 o K = 16 ksi (110.6 MPa) (2/3 rd yield criteria) ** Allowable 80 o K = 8.86 ksi (61.3 Mpa 2/3 rd ultimate criteria) -per ITER test data § Actual margins on max shear are double these values (C 2 = 0.6, S c = Eqn. From NCSX design criteria, 5.6 ksi no compr.) **Sy = xT +14.1xCW xCW 2 = 230.5MPa, 2 x sigma = 64 MPa, = 166, 2/3 x 166 = MPa (16 ksi) (From NIST Monograph 177 -Simon, Drexler, Reed) FDR - Central Solenoid Support Structure - 9/6/06 Load caseMax. Displ. (inch -SRSS) Suppt. Coil Max Tresca Stress -ksi Suppt. Coil Location Suppt. Coil Margin on Allowable* Suppt. Coil Gravity-1g Seismic v h < h 3.44 negl. 2.0 negl. mtg.brkt __ Rods __ 13.5 __ 23.3 __ Thermal (∂30 o K) Cu 4.6 corners /1.2 § EM (23.5kA) mid-coil /8.7 EM + 1g + cooldown (SRSS) Cu mid-coil outer c Stress Analysis Summary

Coil Testing Requirements: Electrical After re-configuring and re-insulation of coolant tubes, coils will require a hi-pot to ground at 2 kV (2 x V op ) and a megger at room temperature and 80 deg.K. Insulating breaks between field periods will be 2kV Mechanical During cool-down for 80 deg.K electrical test, a flow measurement for a delta-P of 10psi will be required. Thermocouples on inlet and outlet tubes will be needed to provide a record of T vs. time for the cool-down. FDR - Central Solenoid Support Structure - 9/6/06

Cost & schedule: Build in-house preliminary est: ~75k$ Will issue an RFQ for 304L & 316L by late Sept.’06 Anticipate a 4-6mo. Delivery A 316L material may delay things a month or two and may cost 30% more.

FDR - Central Solenoid Support Structure - 9/6/06 Conclusions: Charge: Does the coil structure provide adequate support for the PF1a coils with sufficient margins of safety? A: Stress margins on allowables for both coil and support exceed project & code requirements. Have the interfaces with other sub-systems been defined and are they compatible? A: Interfaces to machine structure, cryo-system, and electrical power defined & compatible. Are the drawings and supporting documents complete and ready for sign-off? A: Drawings & BOM are complete and ready for checking/sign-off. Has the analysis been documented and checked? A: The stress & thermal analysis have been documented & are being checked. Are the cost, procurement and assembly schedule consistent with the program schedule and budget? A: Cost & schedule are consistent with project schedule and, pending responses from RFQ, should fall within the current project budget.

FDR - Central Solenoid Support Structure - 9/6/06 per A.Brooks 9/1/06

FDR - Central Solenoid Support Structure - 9/6/06

Fatigue analysis: 304L Peak Tresca Stress: 15.6 ksi (EM + 1g + 30 o K delta) Operating stress below the  130,000 cycles The 2/20 project criteria for fatigue is satisfied although the anticipated usage of the PF1a coils and supports is significantly less than the 130,000 cycles. 20x life 15

Shear Strength CTD112P (w/Kapton) 13.3 deg.K FDR - Central Solenoid Support Structure - 9/6/06

ITER shear-compression tests Max Shear: 6.78 ksi for 15 degree angle(12ksi 77 deg. K FDR - Central Solenoid Support Structure - 9/6/ ksi 40 MPa, 5.8 ksi-static & fatigue

FDR - Central Solenoid Support Structure - 9/6/06 Inner radial stop will maintain central alignment of PF1a coils