SRL/Reference sonde P. Di Girolamo, D. Whiteman, B. Demoz, J. Wang, K. Beierle, T. Weckwerth The Reference sonde (C34) consists of a Snow White (SW) chilled-mirror.

Slides:



Advertisements
Similar presentations

Advertisements

Use of Steam Tables Saturated Vapor or Liquid
Page 1© Crown copyright 2004 Introduction to upper air measurements with radiosondes and other in situ observing systems [3] John Nash, C. Gaffard,R. Smout.
Upper Tropospheric Humidity: A Comparison of Satellite, Radiosonde, Lidar and Aircraft Measurements Satellite Lidar Aircraft Radiosonde.
Radiometrics Corporation 1 Fog Detection & Forecasting Using the the Radiometrics TV/WVP-3000 Temperature, Humidity & Cloud Liquid Profiling Radiometer.
Describing Weather What factors do we use to describe weather?
Lecture 7 Water Vapor.
Water vapour intercomparison effort in the frame of the Convective and Orographically-induced Precipitation Study 6th COPS Workshop 27 – 29 February 2008.
FLASH-B FLASH-B FLuorescent Advanced Stratospheric Hygrometer (for balloon) Instrument design. Observations and comparison. Central Aerological Observatory.
Humidity First let us consider five humidity variables
Water Vapor and Cloud Detection Validation for Aqua Using Raman Lidars and AERI David Whiteman, Belay Demoz NASA/Goddard Space Flight Center Zhien Wang,
Scanning Raman Lidar Error Characteristics and Calibration For IHOP David N. Whiteman/NASA-GSFC, Belay Demoz/UMBC Paolo Di Girolamo/Univ. of Basilicata,
Humidity. Water Vapor Can make up as little as 1/10 th of 1% to 4% of the atmosphere. Scientists agree that it is the most important atmospheric gas when.
1 Review of WMO test results on the accuracy of radiosonde relative humidity sensors John Nash Observing Methods Technology Centre, Development, Met Office.
J31 Data Workshop 9-10Mar05 Water Vapor during ICARTT 2004: Comparison of AATS-14, J31 in situ, Ron Brown sonde measurements NASA Ames Airborne Sunphotometer.
Problems and measuring errors of radiosonde humidity measurements in the global aerological network and new possibilities of their correction and validation.
Atmospheric Measurements Nick Bassill January 28 th 2009.
Evaluation of Dropsonde Humidity and Temperature Sensors using IHOP and DYCOMS-II data Junhong (June) Wang Hal Cole NCAR/ATD Acknowledgement: Kate Young,
Atmospheric Moisture. What is Atmospheric Moisture Changing forms of water Changing forms of water Energy absorbed and lostEnergy absorbed and lost Latent.
Water Vapour Intercomparison Effort in the Frame of the Convective and Orographically-Induced Precipitation Study: Airborne-to-Ground-based and airborne-to-airborne.
Inter-Continental Atmospheric Radiosonde Upper-air Sounding System ( ICARUSS) Hal Cole, Mel Shapiro, Vin Lally, Terry Hock, Rolf Langland Surface & Sounding.
2 nd ISSI Workshop on Water Vapor Instruments, 3-6 November 2008, Bern, Switzerland Measurements Of Humidity in the Atmosphere and Validation Experiments.
Water Vapor and the Atmosphere. Water in the Atmosphere © Precipitation is any form of water that falls from a cloud. © When it comes to understanding.
Water Vapor Intercomparison Workshop, Boulder, 2-3 October 2003 Refractivity During IHOP_2002 Tammy M. Weckwerth (NCAR/ATD), Crystalyne R. Pettet (NCAR/ATD),
Water vapour soundings in the upper troposphere Geraint Vaughan University of Wales, Aberystwyth With thanks to: Clare Cambridge, Alan Phillips, Les Dean,
Radiosondes launched at NSA during the WVIOP04 VAISALA RS90 (operated by ETL and ARM) 4 times per day at the ARM duplex (00, 06, 12, 18 UTC) 1 time per.
Raman lidar characterization of PBL structure during COPS Donato Summa a, Paolo Di Girolamo a, Dario Stelitano a, Tatiana Di Iorio b a DIFA, Univ. della.
Atmospheric Moisture Vapor pressure (e, Pa) The partial pressure exerted by the molecules of vapor in the air. Saturation vapor pressure (e s, Pa ) The.
Boundary layer temperature profile observations using ground-based microwave radiometers Bernhard Pospichal, ISARS 2006 Garmisch-Partenkirchen AMMA - Benin.
1 The NCAR/NOAA Global Hawk Dropsonde System Gary Wick 1, Terry Hock 2, and Ryan Spackman 1 1 NOAA ESRL/PSD, 2 NCAR/EOL.
IHOP Operations Plan, Chapter 7: Other Special Ground-Based Instrumentation Operation Frédéric Fabry et al. General overview Instrument deployment and.
MMS - Ozonesonde Wind and Temperature Comparison during CR-AVE T.P. Bui, J. Dean-Day, C. Chang, R. Castaneda NASA-Ames Research Center H. Voemel University.
Water in the Atmosphere. States of Matter Water vapor – gaseous form (0 to 4% by volume) Water – rain, dew, clouds, fog Ice – snow, hail, clouds.
LASE Measurements During IHOP Edward V. Browell, Syed Ismail, Richard A. Ferrare, Susan A Kooi, Anthony Notari, and Carolyn F. Butler NASA Langley Research.
Intercomparisons of Water Vapor Measurements during IHOP_2002 – Radiosonde and Dropsonde Junhong (June) Wang NCAR Atmospheric Technology Division Acknowledgement:
Concept of Humidity What is the relationship between water vapor holding and temperature? Air hold more water vapour at higher temperature.
AIRS science team meeting Camp Springs, February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements.
Airborne/ground-based sensor intercomparison: SRL/LASE Paolo Di Girolamo, Domenico Sabatino, David Whiteman, Belay Demoz, Edward Browell, Richard Ferrare.
October 02, st IHOP_2002 Water Vapor Intercomparison Workshop Status of intercomparisons and the next steps  Characterize moisture measuring techniques.
IHOP Radiosonde and Dropsonde Data: Highlights and Problems
A new method for first-principles calibration
Page 1 Envisat Validation Workshop, ACVT-GBMCD, MIPAS p&T&H20 12/12/2002 Envisat Validation Workshop Atmospheric Chemistry Validation Team Ground-Based.
AIRS science team meeting, Greenbelt, 31 March 2003 Holger Vömel University of Colorado and NOAA/CMDL Cryogenic Frost point Hygrometer (CFH) Measurements.
Diurnal Variations in Southern Great Plain during IHOP -- data and NCAR/CAM Junhong (June) Wang Dave Parsons, Julie Caron and Jim Hack NCAR ATD and CGD.
Page 1© Crown copyright 2004 Initial results from Tropospheric Airborne Meteorological Data Reporting (TAMDAR) evaluation Dr J. Nash and M. Smees.
Essential Question: How does WATER in the atmosphere affect weather and climate? What is the most important gas in the atmosphere for weather? What is.
Page 1© Crown copyright 2004 Results of the RS92 Acceptance Test performed by the Met Office (UK) Richard Smout, John Nash, Mark Smees, Darren Lyth, May.
NCAR - Atmospheric Technology Division Reporting work by: Erik Miller (ATD) Junhong Wong (ATD) Ari Paukkunen et al. (Vaisala, OY) Funded by: ATD, Vaisala;
Meteorology Science of waters of atmosphere Atmosphere: Atmosphere is the gaseous envelope around the earth Weather and Climate Weather- “the state of.
DOE ARM Calibration / Validation Instrumentation Data essentially available in real-time –ARM (Atmospheric Radiation Measurement) –CART (Cloud And Radiation.
5 th ICMCS - Dry bias in the Beijing radiosonde soundings, 02-Nov-2006 Dry Bias in the Beijing Radiosonde Soundings as Revealed by GPS and MWR Measurements.
Moisture  There are several methods of expressing the moisture content (water in vapor form) of a volume of air.  Vapor Pressure: The partial pressure.
EOS-Aura MLS Validation Using Radiosonde Profiles During the WAVES Campaign Cassie Stearns August 10,2006 Dr. Bojan Bojkov and Dr. David Whiteman, Advisors.
A U.S.-Japan Workshop on the Tropical Tropopause Layer
Continuous Humidity Profiling using a Wind- Profiler Radar in the UHF band (continued) F. Saïd* (1), B. Campistron (1), D. Bengochea (1), O. Bock (2),
U.S. Radiosondes Jan. 2000, NWS awarded contracts to two radiosonde manufacturers, Sippican and InterMet Systems, for the development and submission of.
What are they? What do they do?
Driftsonde System Capabilities
Evaluation for China L band radiosonde
Expert team on Upper Air System Intercomparisons,
Summary Sondes RS 80 has dry bias. RS 92 virtually without bias
Instruments for measuring physical quantities of the environment Standard EN ISO 7726 Accepted in 2001 Marianna Luoma.
LASE Measurements of Water Vapor During IHOP
Preliminary Analyses of S-Pol’s Refractivity Field
March 13, 2012 Get out your homework to be checked for completion
Upper air Meteorological charts
Upper Air Data The Atmosphere is 3D and can not be understood or forecast by using surface data alone.
E.7.9A.1, E.7.9A.2, E.79A.3 Weather.
Dropsonde RICO Atmospheric Technology Division/ NCAR Terry Hock
Unit 2: “Earth and Space Science”
Presentation transcript:

SRL/Reference sonde P. Di Girolamo, D. Whiteman, B. Demoz, J. Wang, K. Beierle, T. Weckwerth The Reference sonde (C34) consists of a Snow White (SW) chilled-mirror dew point hygrometer and a carbon hygristor for humidity measurements. Accuracy: 0.25 % in terms of relative humidity measurements. The SW needs no individual calibration and can be used again without recalibration if recovered after flight.

Comparison between SRL and NCAR Reference radiosondes NCAR Reference radiosonde Nine reference radiosonde were launched in Homestead during IHOP Eight of these were launched at times when SRL was operational. Only three reference radiosondes were launched during the 11 days for which SRL data have been released (Z _162645, Z _ and Z _025610).

Comparison between SRL, reference sonde (both SW and carbon hygristor) and closest in time Vasiala RS 80. SRL data have been interpolated at sensors’ heights. Unfortunately, some data points result to be missing in the reference sonde profiles. Reference sonde Z _ no height information between 1400 and 1850 m Reference sonde Z _ Large gaps of humidity information (2-3.5 km; km) pressure information result to be missing (only the surface value results to be available). Deviations beween SRL and reference radiosonde are as large as 20 %.

Z _ side by side with y hom Z _ simultaneously with y hom Z _ simultaneously with y hom The Reference Sonde (RS) uses a hypsometer to measure pressure. This sensor is not reliable so we did not use the pressure data from the RS, but we used the pressure data from the Vaisala radiosondes, which is good.

Mixing ratio: direct measurement for the Raman lidar Relative humidity: direct measurement for the radiosonde Relative humidity water vapour mixing ratios saturation vapour pressure, which depends of pressure and temperature. Several empirical relationships, which we compared and revealed deviations between them up to 3 %. –WMO formulation –Bolton formulation (1980) –Expression derived from Smithsonian Meteorological Tables. IHOP_2002 Water Vapor Intercomparison Workshop, 2-3 October 2003, NCAR, Boulder, CO

SRL data are quite close to SW (differences <10 % up to 3.5 km a.s.l.)

SRL is moister than SW (differences ~ -20 % up to 4.8 km a.s.l.) Much better agreement above Integration time for lidar to be changed in order to meet reference sonde effective launch time, which is not 10:46 UT, but 11:40 UT Wind speed in BL > 15 m/s, so that different air masses are sounded from Lidar and sondes

SRL is drier than SW below ~ 2.3 km a.s.l., moister between 2.3 and 3 km, and drier above (differences ~ -30 to +20 %) Integration time for lidar to be changed in order to meet reference sonde effective launch time, which is not 02:56 UT, but 03:35 UT Wind speed in BL > 15 m/s