Planning UES: Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 7/21/2015.

Slides:



Advertisements
Similar presentations
Advanced Heat Pump Water Heater Research Conducted by WSU Energy Program Funded by Bonneville Power Administration BPA Technology Innovation Project #292.
Advertisements

Direction on Guidelines Savings Definition Path Results of straw vote and proposed decisions for elements of the savings definition Regional Technical.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
Transformer De-Energizing & Dairy Plate Heat Exchanger Standard Protocol Proposal Presentation to the RTF February 20, 2013.
High Performance Manufactured Homes Provisional UES Proposal Presentation to the Regional Technical Forum May 15, 2012 Project Sponsor: Bonneville Power.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential Heat Pump Water Heaters UES Measure Update Proposal Regional Technical Forum November 18, 2014.
Residential and Commercial Storage Electric Resistance Water Heaters (Efficient Tanks) Mohit Singh-Chhabra Regional Technical Forum February 18, 2015.
Addressing Market Transformation Lag Jennifer Anziano Regional Technical Forum May 15, 2015.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Residential Heat Pump Water Heaters Heating System Interaction Factor RTF HPWH Subcommittee November 6, 2014.
Research Strategy Review: Heat Pump Water Heaters Thermostatic Restriction Valves Jennifer Anziano RTF R&E Subcommittee July 8, 2015.
Heat Pump Water Heater (HPWH) Subcommittee Christian Douglass Regional Technical Forum June 18, 2015.
Regional Heat Pump Water Heater Evaluation Committee Kickoff March 8 th, 2012.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
Implementer’s Group April 2015 Meeting Debrief and Upcoming Meeting Prep April 24, 2015.
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
HPWH UES Measure Initial Review 16 April Agenda Provisional Measure Review Method Overview Prelim Findings Measure Development Approach Simulation.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
New Measure Proposal Review and Prioritization Jennifer Anziano, Adam Hadley, Mohit Singh-Chhabra, Christian Douglass Regional Technical Forum February.
Guidelines for the Development and Maintenance of RTF- Approved Measure Savings Estimates December 7, 2010 Regional Technical Forum Presented by: Michael.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Delivery Verification Jennifer Anziano Regional Technical Forum March 17, 2015.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum May 12, 2015.
RTF Delivery Verification Guidance Batch 1 Jennifer Anziano Regional Technical Forum May 12, 2015.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
Integration Issues for RTF Guidelines: Savings, Lifetimes and Cost/Benefit October 24, 2012 Regional Technical Forum Presented by: Michael Baker, SBW.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Bonneville Power Administration Heat Pump Water Heater Laboratory Testing Results & Field Work.
Implementer’s Group June 2015 RTF Meeting Debrief and Upcoming Meeting Prep June 23, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
ENERGY STAR and EcoRated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Commercial Clothes Washers UES Ryan Firestone Regional Technical Forum April 14, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Residential Showerheads UES Update Ryan Firestone Regional Technical Forum October 20, 2015.
RTF Delivery Verification Guidance Batch 2 Jennifer Anziano Regional Technical Forum September 22, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
Non-Residential Network Computer Power Management Christian Douglass Regional Technical Forum January 21, 2016.
Exterior LED Area Lights
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Northwest Power and Conservation Council Slide 1 Heat Pump Water Heaters Tom Eckman Manager, Conservation Resources Northwest Power and Conservation Council.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northern Climate HPWH Spec Update.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Heat Pump Water Heater Market Transformation Update March 27th 2012Dave Kresta.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Heat Pump Water Heaters: Interior, Ducted Installations Presentation to the Regional Technical Forum December 13, 2011 Ben Larson, Ecotope
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Standard Information Workbook: Update Proposal Christian Douglass Regional Technical Forum March 15, 2016.
Presentation transcript:

Planning UES: Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 7/21/2015

Presentation Overview Today we are seeking a decision from the RTF on the following residential HPWH measure updates: Savings and costs – related to new efficiency tier and baseline definition Research strategy – proposed addition to existing strategy 2

Measure Overview Measure DevelopersNEEA, Ecotope CAT ReviewChristian Douglass Tech Sub-Com ReviewYes (6/18/2015)6/18/2015 R&E Sub-Com ReviewYes (7/8/2015)7/8/2015 Notes Measure last updated in November 2014November 2014 Current measure does not sunset until the end of 2015; however, request to add new Tier 3 measure additional research need identified for research strategy would like to address baseline issue, so measure status can be set to “Active” 3

Subcommittee Attendance 4 Technical Subcommittee Christian Douglass, RTF Contract Analyst Geoff Wickes, NEEA Dane Christensen, NREL Jim Maunder, Ravalli Electric Rick Knori, Lower Valley Energy Janice Peterson, BPA Adam Hadley, RTF Contract Analyst Jennifer Anziano, RTF Manager Greg Kelleher, EWEB Robert Weber, BPA Mike Baker, SBW Mark Johnson, BPA Aaron Winer, CLEAResult Dave Baylon, Ecotope Sarah Widder, PNNL David Murphy, BPA R&E Subcommittee Philip Kelsven, BPA Mark Jerome, CLEAResult James Domanski, CLEAResult Ben Larson, Ecotope Greg Kelleher, EWEB Peter Miller, NRDC Jim Perich-Anderson, Puget Sound Energy Rachel Clark, Tacoma Power David Hales, WSU Energy Program Jennifer Anziano, RTF Manager Christian Douglass, Contract Analyst Adam Hadley, Contract Analyst Mohit Singh-Chhabra, Contract Analyst

Savings and Costs 5

Scope of This Update Adding additional performance tier (Tier 3) based on new product in the market – Affects savings and costs for Tier 3 and Tier 2, since new product can perform at either level based on user settings – New product is the only HPWH currently available at Tier 2 or Tier 3 Revising current practice baseline definition – Affects savings and costs for all measures 6

HPWH Market Snapshot 7 Efficiency TierSize (gal)Models Tier 10-55AO Smith SHPT-50 Rheem HB50 >55AO Smith SHPT-66 AO Smith SHPT-80 Stiebel Eltron Accelera 220 Stiebel Eltron Accelera 300 Tier 20-55General Electric GEH50D* >55General Electric GEH80D* Tier 30-55General Electric GEH50D** >55General Electric GEH80D** * Meets Tier 2 efficiency levels when set to default hybrid mode ** Meets Tier 3 efficiency levels when set to Cold Climate Efficiency mode

Tier 2 / Tier 3 Performance Update 8 Updated HPWH performance characteristics (e.g. COP curves, control schemes) in SEEM to reflect new Tier 2/Tier 3 product – Added Tier 3 performance characteristics and measures – Replaced current Tier 2 performance characteristics (based on Airgenerate ATI) with those of new product – Kept Tier 1 performance characteristics the same Note: Performance characteristics were derived from lab tests of new product (i.e. not field tests) – This is relevant to the “Research Strategy” portion of today’s presentation

Current Practice Baseline Update 9 Electric Resistance Water Heater (ERWH) can meet minimum Energy Factor for tanks 0 – 55 gal in size Tier 1 Heat Pump Water Heater (HPWH) needed to meet minimum Energy Factor for tanks > 55 gal Current HPWH measure is “Under Review” due to uncertainty in baseline Subcommittee discussed current practice baseline during 6/18 meeting Key issue discussed: where to set baseline efficiency for various tank sizes in light of the recent federal standard April 2015 Federal Standard

Current Practice Baseline Update At subcommittee, CAT proposed keeping baseline definition simple and combining all tank sizes in a single baseline (and measure) – As a result, all HPWHs have some savings, even Tier 1 tanks >55 gal Why may there be savings for Tier 1 tanks >55 gal? – Strong arguments that the actual purchased HPWH size is not necessarily equal to the tank size purchased in the counterfactual Common to upsize a HPWH relative to a resistance tank (e.g. 50 gal electric resistance to 60 gal HPWH) Specific makes and models only come in certain sizes Tank size is only one of many deciding factors (price, reliability, availability) 10

Current Practice Baseline Update Feedback from subcommittee (and implementers group): – Overwhelmingly supported concept of keeping the baseline definition simple – Majority of subcommittee supported the CAT proposal and combining all tank sizes – Some programs uncomfortable incenting >55 gal Tier 1 tanks, and would rather assume Tier 1 as the baseline. This means effectively that: All large HPWH purchases would have been large tank purchases in the counterfactual All small HPWH purchases would have been small tank purchases in the counterfactual 11

Current Practice Baseline Update: A Tale of Two Baselines 12 In summary, we have two different program views of the baseline CAT’s proposal for today: – Include measure sets for both baselines, i.e. one measure set for “any size tank” and one set for small (0-55) and large (>55) tanks separately Part of measure specification will be that programs can use only one measure set or the other Proposal is pragmatic, not perfect – Use future regional research that addresses this question, but not add to the existing RTF research strategy at this time Consistent with RTF direction provided in April of this year Allows region to focus on more tangible research questions already identified in the strategy

Summary of Baseline Assumptions 13 Current Practice Baseline Description Measure Identifier Current Practice Baseline Assumption Explanation of Baseline Assumption % ERWH % Tier 1 HPWH % Tier 2 HPWH % Tier 3 HPWH Small Tank / Large Tank 0-55 gallon tank HPWHs approximately 2% of electric storage water heater market share in the Northwest (for tanks gallons), per NEEA market data >55 gallon tank Assume Tier 1 HPWH as minimum baseline efficiency per the April 2015 federal standard -Assume fraction of Tier 1 versus Tier 2 HPWHs based on current distribution of models available (slide 7). Any Size Tank N/A Estimates penetration of HPWHs in the total electric tank market (all sizes) -Next couple of slides explain the derivation of the assumed values

Any Size Tank Baseline: Explained Starts with the following assumptions: – Prior to the 2015 federal standard, eligible end users are choosing tank sizes in proportion to the RBSA stock – HPWHs have a small fraction of market share (from NEEA market data) for both small and large tanks % 88.8% 0.1% 9.6%

Any Size Tank Baseline: Explained Then assume: – After the 2015 standard, 50% of large tank end users will purchase large HPWHs, while 50% will purchase one or more small ER tanks Why 50%? This ensures that the sensitivity to savings is less than +/- 10% (turns out to be about +/- 7.5%) If we choose a fraction at one of the extremes (i.e. 0% or 100%), the impact to savings can be closer to +/- 15% – The typical choices across all tank sizes will then be comprised of 6% HPWHs (1.5% + 0.1% + 9.6% * 0.5) and 94% ERWHs (88.8% + 9.6% * 0.5) 15

16 Efficiency TierInstall LocationHeating ZoneHVAC TypeTank Size Tier 1Unconditioned Basement1 / 2 / 3N/AAny Tier 1Unconditioned Basement1 / 2 / 3N/ASmall Tier 1Unconditioned Garage1 / 2 / 3N/AAny Tier 1Unconditioned Garage1 / 2 / 3N/ASmall Tier 1Conditioned Interior, Non-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpAny Tier 1Conditioned Interior, Non-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpSmall Tier 2Unconditioned Basement1 / 2 / 3N/AAny Tier 2Unconditioned Basement1 / 2 / 3N/ASmall / Large Tier 2Unconditioned Garage1 / 2 / 3N/AAny Tier 2Unconditioned Garage1 / 2 / 3N/ASmall / Large Tier 2Conditioned Interior, Non-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpAny Tier 2Conditioned Interior, Non-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpSmall / Large Tier 2Conditioned Interior, Exhaust-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpAny Tier 2Conditioned Interior, Exhaust-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpSmall / Large Tier 3Unconditioned Basement1 / 2 / 3N/AAny Tier 3Unconditioned Basement1 / 2 / 3N/ASmall / Large Tier 3Unconditioned Garage1 / 2 / 3N/AAny Tier 3Unconditioned Garage1 / 2 / 3N/ASmall / Large Tier 3Conditioned Interior, Non-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpAny Tier 3Conditioned Interior, Non-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpSmall / Large Tier 3Conditioned Interior, Exhaust-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpAny Tier 3Conditioned Interior, Exhaust-Ducted1 / 2 / 3Gas / Elec Res / Heat PumpSmall / Large Proposed Measure List Summary

Updated Savings: Any Size Tank, HZ1 17

Updated Savings: Any Size Tank, HZ2 18

Updated Savings: Any Size Tank, HZ3 19

Updated Savings: 0-55 gallons and >55 gallons, HZ1 20

Updated Savings: 0-55 gallons and >55 gallons, HZ2 21

Updated Savings: 0-55 gallons and >55 gallons, HZ3 22

Updated Costs: Any Size Tank, All HZs 23

Updated Costs: 0-55 gallons and >55 gallons, All HZs 24

Updated TRC B/C Ratios: Any Size Tank, HZ1 25

Updated TRC B/C Ratios: Any Size Tank, HZ2 26

Updated TRC B/C Ratios: Any Size Tank, HZ3 27

Updated TRC B/C Ratios : 0-55 gallons and >55 gallons, HZ1 28

Updated TRC B/C Ratios : 0-55 gallons and >55 gallons, HZ2 29

Updated TRC B/C Ratios : 0-55 gallons and >55 gallons, HZ3 30

Delivery Verification 31 Measure Specification Delivery Verification Checklist ComponentSpecificationAdditional NotesHPWHs Measure Identifiers Efficiency TierTiers 1, 2, and 3 from NEEA's Northern Climate Heat Pump Water Heater Specification. □ Check whether unit is installed in an unconditioned garage/basement or a conditioned interior space. If unit is installed in conditioned interior space, □ Check whether heating system is a gas furnace, resistance type (electric furnace or electric zonal) or a heat pump. Install LocationUnconditioned garage, unconditioned basement, conditioned interior. □ Check whether exhaust air is ducted to the outside. HVAC TypeGas, electric resistance (electric furnace or zonal), heat pump. Applies only to conditioned interior installs. □ Check the heating zone. Exhaust DuctingDucted or unducted. Applies only to Tiers 2 and 3 and only conditioned interior installs. Note: Delivery verification guidance for efficiency tier is provided below. Heating Climate Zone Heating Zones (HZs) 1, 2, and 3 Savings BaselineCurrent Practice N/A Implementation and Product Standards NEEA Northern Climate Heat Pump Water Heater Specification The specification and qualified products list (QPL) can be found at □ Check that unit is listed on the Northern Climate Specification QPL for the claimed efficiency tier or the unit meets all efficiency requirements of the Northern Climate specification for the claimed tier. □ If tier qualification is dependent on operation mode, check that operation mode is set to the one required by the claimed tier. Sunset Date7/31/2016Sunset factors: Review market shifts and baseline assumptions.

Research Strategy 32

Background Res HPWH measure already has existing research strategy that was adopted at April 2015 RTF meetingApril 2015 RTF meeting – Existing strategy deals with HVAC interaction factor – Not proposing to open up this part of the strategy for discussion Since then CAT has put research strategy in a new Word document template – No longer simply slides in a slide deck – Desire for research strategies to be stand-alone documents with consistency in appearance and content for sharing with stakeholders Today’s proposal is to add a second objective to the existing strategy 33

Why do we need additional research? Up to this point, performance characteristics for all HPWH models within SEEM have been calibrated to field data to reflect “real world” performance and savings The problem is: – We know that new products entering the market may perform very differently than those of the past – It is not sustainable ($$$) to collect field data for every new model that enters the market 34

Why do we need additional research? We cannot calibrate HPWH performance to the DOE lab tests that are already being performed for each new model – DOE draw patterns are somewhat artificial and not reflective of in situ draw patterns – Evidence that manufacturers “design to the tests” for higher rated COPs – Ecotope compared lab calibrated results to field calibrated results for older GE tank and found significant underestimation of resistance element use and overestimation of heat pump use 35

Proposed Research 36 Add an additional lab test to the existing DOE test suite which uses “real world” water draw patterns collected from field data Perform new lab test on two older tanks for which we have field data Compare the calibrated performance characteristics resulting from the lab data to those resulting from the field If results compare well, use new lab test moving forward to calibrate tank performance and energy savings This is documented in more detail in the Research Strategy posted on the agenda.Research Strategy

Subcommittee Feedback Proposal was shared with both the technical HPWH Subcommittee and the Research and Evaluation Subcommittee Both subcommittees were satisfied with the approach 37

Proposed Motion “For the Residential Single Family and Manufactured Home HPWH UES measure, I _________ move the RTF: Approve the measure updates as presented; Adopt the revised research strategy; Keep the Category at Planning; Change the Status to Active; Set the sunset date to 7/31/2016.” 38