ENERGY STAR and EcoRated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.

Slides:



Advertisements
Similar presentations
Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
Advertisements

SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Direction on Guidelines Savings Definition Path Results of straw vote and proposed decisions for elements of the savings definition Regional Technical.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Heat Pump Water Heater (HPWH) Subcommittee Christian Douglass Regional Technical Forum June 18, 2015.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF MH Calibration Subcommittee February 27, 2015.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
Manufactured Homes Calibration: Existing and New Homes Josh Rushton & Mohit Singh-Chhabra RTF Update June 16, 2015.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Delivery Verification Jennifer Anziano Regional Technical Forum March 17, 2015.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
Refrigerator Decommissioning: Measure Status Update Regional Technical Forum October 16, 2013.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
New-Construction Manufactured Homes: Update on the Path to Proven Savings Regional Technical Forum November 10 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
New Construction Calibration Preliminary Research and a Request for Guidance on Issues Raised in December Regional Technical Forum January 22, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Where did it go? Lost savings found in real-world data SEEM Calibration for the Northwest Power and Conservation Council’s Regional Technical Forum (RTF)
Research Strategy: New-Construction Manufactured Home Measures Research and Evaluation Subcommittee Josh Rushton November 19, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
RTF Management Updates Jennifer Light Regional Technical Forum January 21, 2016.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
RTF Management Update Jennifer Anziano Regional Technical Forum July 21, 2015.
Non-Proven Residential Duct Sealing Measures: Research Strategy Josh Rushton and Adam Hadley Research and Evaluation Subcommittee October 7, 2015.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Exterior LED Area Lights
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

ENERGY STAR and EcoRated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra

Objective Seeking RTF Decision on new-construction MH measures, ENERGY STAR and EcoRated MH. CAT recommendation: Planning UES (with Research Strategy) Active status Sunset December,

Presentation Roadmap New construction MH baseline Developing Planning Savings Estimates – Non-electric heat adjustment (Phase II calibration factor) for new construction MH – Aligning SEEM.69 with billing data (Phase I calibration factor) for all electric homes Research Strategy Decision 3

MH New Construction Baseline 4 - Baseline

Guidelines : Roadmap Section “A current practice baseline is used if the measure affects systems, equipment or practices that are at the end of their useful life or for measures delivering new systems, equipment or practices, e.g., ENERGY STAR ® specifications for new homes…… “For these measures, the baseline is defined by the typical choices of eligible end users in purchasing new equipment and services at the time of RTF approval. The RTF estimates this baseline based on recent choices of eligible end users in purchasing new equipment and services…. “The RTF may decide to use an alternative current practice based on other factors” Note: The most commonly used baseline for Current Practice Measures is a “typical choices” baseline 5 - Baseline

Manufacturer HUD Minimum (%) Somewhat Improved (%) ESTAR HUD (%) Typical Choices Baseline 6-- Baseline Typical choices baseline is market mix of standard-construction and efficient-case homes (everything in the red box) Source: BPA High Performance Manufactured Homes (HPMH) report (2012) Note: Numbers do not add up to a 100% as these Manufacturers also build modular homes

Manufacturer HUD Minimum (%) Somewhat Improved (%) ESTAR HUD (%) Typical Choices Baseline 7-- Baseline Typical choices baseline is market mix of standard-construction and efficient-case homes (everything in the red box) Source: BPA High Performance Manufactured Homes (HPMH) report (2012) Issue with typical choices baseline: NEEM program is unique to the Northwest and may be responsible for the current state of the market. As per the 2012 presentation on HPMH: “NEEM participation dropped significantly at the end of MAP, and Energy Star participation elsewhere in the country has rather minimal market share (~10%) in the absence of incentives”

Manufacturer HUD Minimum (%) Somewhat Improved (%) ESTAR HUD (%) The Current Baseline In current measure workbook, baseline is defined as market mix of non-NEEM homes Source: High Performance Manufactured Homes (HPMH) report (developed for BPA by Northwest Energy Works, 2012) 8-- Baseline

The Current Baseline (Contd.) Underlying Assumption: if the NEEM program support were to cease, the new construction market would be similar to the current non-NEEM MH mix Reasoning: NEEM participation dropped significantly at the end of MAP, and Energy Star participation elsewhere in the country has rather minimal market share (~10%) in the absence of incentives The issue with choosing this baseline is that we don’t really know whether a significant portion of would-be NEEM homes would revert to HUD minimum without program support – Would ENERGY STAR market share really drop all the way to zero? – Would efficiency-minded customers who forego ENERGY STAR really go all the way down to HUD minimum at the same rate as non-NEEM customers? Manufacturers could also manufacture Somewhat Thermally Improved homes instead (which many are already doing) in the absence of program support 9 - Baseline

Manufacturer HUD Minimum (%) Somewhat Improved (%) ESTAR HUD (%) Staff Recommendation: Somewhere in Between Assumption: Without program support, average efficiency of would-be NEEM homes drops to “Somewhat Thermally Improved” levels Baseline This baseline is in-between the two other choices we have. ESTAR now at Somewhat Thermally Improved

Baseline Options: RTF Direction Required Continue with Current Assumption – Baseline is equal to the mix of Non-NEEM homes currently in the market Typical Choices – Baseline will represent an average of NEEM and non- NEEM homes in the proportion of their respective market share Somewhere in Between: – The NEEM homes will look like the Somewhat Thermally Improved (previous slide) 11- Baseline Staff Recommendation

Developing Planning Savings Estimates 12

Current Measure Specifications 13- Savings Component Baseline (Somewhere in Between) ENERGY STAREcoRated Ceilings (flat) Avg. R-33 Nominal; U = Effective Flat: R-49 Nominal; U=0.025 Effective Ceilings (vaulted)Vaulted: R-40 Nominal; U=0.029 Effective Walls Avg. R-18 Nominal; U= Effective R-21 Nominal; U=0.055 Effective R-21 w/no trade off & requires insulated header; U=0.055 Effective Floors Avg. R-25 Nominal; U = 0.04 Effective R-33; U=0.033 EffectiveR-38 Blown-in; U=0.033 Effective GlazingAvg. U=0.32U=0.32U=0.32 area weighted avg. Appliances built- in BaselineENERGY STAR Dishwasher ENERGY STAR Refrigerator Lighting No requirement (Current Practice) 80% fixture CFL Envelope Tightness No requirement5.0 ACH 50 (avg 3.9 ACH 50 found in 2009 field study) Heating System 78% AFUE Gas FAF; or Electric Furnace; or 8.5 HSPF Heat Pump 80% AFUE Gas FAF; or Electric Furnace; or 8.5 HSPF Heat Pump 90% AFUE Gas FAF; or Electric Furnace; or 8.5 HSPF Heat Pump Duct Leakage 13% (est from old NEEM studies that pre-date duct sealing reqs) 0.06 x Floor Area CFM 50 in-plant test (5% Supply Leakage Fraction, 2009 field study) Approximate Uo

Existing Savings Estimates: Not Recommended Measure specifications have changed: – Infiltration: At the time of measure development, infiltration for baseline was assumed to be 7 ACH 50 – Lighting and Appliances: had significant savings, ~1000 kWh; now less than 50 kWh due to updated standards and efficient current practice – Other specs mostly the same Measure savings calculated using SEEM.92. Update made to SEEM since then mainly impacts heating energy savings due to infiltration (among other smaller changes) Note: Proposed Planning Estimates (next) have been calculated with updated measure specifications 14- Savings

Developing Planning Savings Estimates: Non Electric Heat Adjustment (Calibration Phase II) 15

Non-Electric Heat Adjustment (Phase II) The Phase II calibration factor accounts for the possible presence on non-electric fuels (e.g. wood heat) on annual electric heating energy −Existing homes Phase II factor is 8% for HZ1 and 14% for HZ2 & HZ3 Homes in NEEM dataset have lower incidence of non-electric heat than homes in RBSA dataset. Thus, Phase II factor was adjusted based for new construction MH based on the NEEM dataset. Staff Proposal: Phase II factor = 2.5% for all HZ – NEEM data suggests that only 7 % of electrically heated homes (4 out of 55) had non-electric heat presence Assuming that these are medium off grid use homes, gives us a Phase 2 factor of 2.5%. i.e. adjustment factor of (100% - 2.5% = 97.5%) Reminder: for MH there was no additional adjustment for gas heat and a very small adjustment for unoccupied homes 16 Savings: Phase II

Developing Planning Savings Estimates: Aligning SEEM with Billing Data for Electrically Heated Homes (“Phase I”) 17

All Electric Home Heating Energy (Phase 1) Adjustment Factor Phase I calibration factor developed using regression to understand differences between SEEM (69/64°F) and billing data (VBDD) heating energy estimates. We have two options: SEEM.69: Calibration based on NEEM data only. – Same Phase I calibration factor Pre- and Post- Calibration Curve: Calibration based on NEEM and RBSA data – Phase I Calibration factor varies pre- and post-. Consistent with existing measure (Planning) Savings estimate calculated using the two options differ significantly from each other Staff proposes taking the average of both options – Research strategy is focused on resolving this issue 18- Savings Phase I Staff Recommendation

SEEM.69 This is a NEEM only calibration Result is that Phase I calibration factor ≈ 1 for baseline and efficient case – SEEM.69 thermostat settings work on average for NEEM homes Closest to a physics estimate in energy reduction 19- Savings Phase 1 – Reminder: Comparison of VBDD.heat.kWh to SEEM.69.kWh for NEEM homes, presented to the RTF at the November ‘15 meeting

SEEM.69 (contd.) The possible issue with using SEEM.69 method for determining energy savings is that NEEM data does not include homes with different shell efficiencies In two (limited) comparisons for existing homes, CAT has found reasonable agreement between savings estimated from pre-/post- program billing data and savings estimated using the existing (RBSA- based) calibration – Existing SF weatherization savings comparison to ETO data Note: Some issues that limit the MH RBSA’s suitability for calibration are less problematic in the SF calibration – Existing MH weatherization savings using IDP data – ORNL report on MH Wx Program Evaluation in 5 states: Model calibrated to pre case for existing MH; when compared with billing data savings had to be adjusted by a realization rate of 0.6 (5 States are North Dakota, Wisconsin, Ohio, Missouri, and Virginia) We do not have any similar comparisons for new homes. – This is what the Research Strategy seeks to address. 20- Savings Phase 1

Calibration Curve Include MH RBSA data in calibration Calibration adjustments differ between baseline and efficient cases – Consistent with existing MH and SF measures Graph at left shows percent differences between SEEM.69 and VBDD in existing MH calibration (based on RBSA data only) Graph at right shows differences in absolute kWh terms for NEEM and RBSA (electric-resistance homes only) Both suggest less savings than the physics predicts 21- Savings Phase 1 (RBSA data only) (Electric resistance only)

Calibration Curve (contd.) The possible issues with selecting Calibration Curve based estimates are: We don’t have data to understand where baseline new construction homes lie on the calibration curve MH RBSA and NEEM samples not comparable w.r.t calibration requirements 22- Savings Phase 1 (RBSA data only) (Electric resistance only)

How the numbers stack up… 23- Savings Phase 1

Staff Proposal Both SEEM.69 and Calibration Curve Options have uncertainty associated with them, Staff proposes using an average of the two options for planning estimate 24- Savings Phase 1 Staff Proposal

Heat Pump New Construction Measures A calibration curve for heat pump measures does not exist and there is uncertainty regarding the performance levels of HP in MH in the region. For Planning estimates, propose to calculate HP heating energy consumption estimate by dividing RTF approved eFAF energy consumption estimate by average COP per HZ. The COP for each run is calculated as SEEM electric heating output divided by SEEM electric heating input Average COP per heating zone is calculated as an average of the individual COP for all new construction runs Data collected and analyzed through the methods outlined in existing MH Heat Pump Commissioning Controls & Sizing, and the MH New Construction Research Strategies will provide the necessary inputs to calculate energy savings Savings

Savings Comparison: ENERGY STAR MH 26 - Savings

Incremental Cost: ENERGY STAR MH 27- Savings

TRC Comparison: ENERGY STAR MH 28 - Savings

Savings Comparison: EcoRated MH 29 - Savings

Incremental Cost : EcoRated MH 30 - Savings

TRC Comparison: EcoRated MH 31 - Savings

Delivery Verification Guidance Homes must be rated NEEM certified as ENERGY STAR or Ecorated by Northwest Energy Works 32 - Savings

Research Strategy 33

R&E Subcommittee Review R&E Subcommittee Meeting on November 19, 2015 Participants – Josh Rushton, RTF Contract Analyst (presenter) – Jennifer Light, RTF Manager – Adam Hadley, RTF Contract Analyst – Mohit Singh-Chhabra, RTF Contract Analyst – Christopher Frye, NEEA – Mark Jerome, CLEAResult – Howdy Reichmuth – Greg Keller, EWEB – Tom Eckhart, UCONs – Lauren Gage, Bonneville – Dan Rubado, Energy Trust – Jim Perich-Anderson, PSE – Richard Cole – Brad Acker, University of Idaho, Integrated Design Lab – Peter Miller, NRDC – Philip Kelsven, Bonneville – Bob Davis, Ecotope – Dave Baylon, Ecotope 34 – Research Strategy

Research Objectives UES values should be “closely tied” to observed differences in kWh between standard and efficient MHs – Engineering models okay for some adjustments but results should be “largely driven” by observed kWh differences Need sample of efficient-case homes and comparable sample of standard-construction homes with… – Energy consumption data – Characteristic data needed to meaningfully compare kWh across the samples Not explicit objectives: – Updating component specs in standard or efficient-case homes (doesn’t mean RTF can’t use new data if it’s helpful) – Updating mix of standard- and efficient-case homes included in the baseline (left to RTF judgment) 35 – Research Strategy

Straw-proposal Sampling: Final target is 154 standard- and 154 and efficient-case MHs – 90% confidence band for savings projected as ±750 kwh (≈ 30%-40% rel. precision) – Emphasis on samples being comparable (being fully representative less important) Okay to limit to 1 or 2 heating zones (maybe just ETO territory) Intent is to estimate minimum research lift – Results “may be difficult to interpret” if heat pump homes included Data collection: – Location, specs, label (NEEM, EcoRated, standard) from manufacturer/retailer – Billing data from utility or program – System (HP, E-FAF, G-FAF) & wood heat indicator from phone call or drive-by Analysis: – Run SEEM and VBDD for each site in the sample – Fit regression to estimate VBDD.kWh as a function of SEEM.69.kWh – Use regression results for calibrate savings Cost estimate: $100k-$250k (assumes written data releases not required) 36 – Research Strategy

RTF Decision “I, _______, move that the RTF set the measure Status and Category for the NEEM certified ENERGY STAR and EcoRated MH measures to ‘Active’, ‘Planning’ and: Adopt the savings estimate developed using: – ‘Somewhere in between’ baseline for MH new construction – Staff proposal to set Non-Electric heat adjustment (Phase II) factor to 2.5% – Staff proposal to use the average of the two options presented to determine adjustment for all electric home annual heating energy (Phase 1) use for electric resistance heated MH – Staff proposal to use HZ specific COP to calculate energy savings for new construction MH with heat pumps Adopt the Research Strategy as presented Set a Sunset Date of 12/2018” 37 - Decision