NSTX TF Flag Joint Torque Collar Chit Review C Neumeyer 9/11/3.

Slides:



Advertisements
Similar presentations
FEA as an aid in Design 1.Applying FEA to a fairly complex design can initially overburden us with information. We therefore need a method of analysing.
Advertisements

Testing Test Setup TapLok Insert Shear Key Copper Threads Friction Tests Collar Shear Tests NSTX TF FLAG JOINT REVIEW 8/7/03 Michael Kalish.
Fasteners / Joint Design Michael Kalish NSTX TF FLAG JOINT REVIEW 8/7/03.
1 Bolts in Tension pt1 Andrei Lozzi. The flanges at the end of the two turbine shafts seen above, are bolted together to form a very rigid friction coupling.
The Effect of T-Stiffener Web and Flange Tilt on Frame Stress Evaluated using Finite Element Analysis by Dean Pasquerella MASTER OF ENGINEERING Major Subject:
Chapter Outline Shigley’s Mechanical Engineering Design.
FEA as an aid to Design Andrei Lozzi 2014
J. H. ChrzanowskiNSTX TF Flag Joint Design Review1 NSTX TF Flag Joint Design Review Fabrication and Assembly April 10, 2003 By: James H. Chrzanowski.
NSTX TF Flag Joint Review ANALYSIS & DESIGN C Neumeyer 9/3/3.
Slide HALLD TAGGER MAGNET STRUCTURAL ANALYSIS Presented by William Crahen 6/10/09 Pole Plate analysis Vacuum chamber analysis Vacuum chamber tie rods and.
Screws, Fasteners, and the Design of Nonpermanent Joints
NSTX Center Stack Upgrade Workshop Brainstorming on Design Solutions for TF Joint C Neumeyer Jan 22, 2009.
CM 197 Mechanics of Materials Chap 20: Connections
Component Testing Test Setup TapLok Insert Shear Key Copper Threads Friction Tests Collar Shear Tests NSTX TF FLAG JOINT REVIEW 8/7/03 Michael Kalish.
Status of the Coil Structure Design and Magnetic-Structural Analysis Presented by X.R. Wang Contributors: UCSD: S. Malang, A.R. Raffray PPPL: H.M. Fan.
NSTX ARMOR PLATE 2/18/10 NEUTRAL BEAM ARMOR PRELIMINARY ANALYSIS.
Fasteners / Joint Design Michael Kalish NSTX TF FLAG JOINT REVIEW 4/10/03.
Fasteners / Joint Design Michael Kalish NSTX TF FLAG JOINT REVIEW 8/7/03.
Component Testing Test Setup TapLok Insert Shear Key Copper Threads
1 FIRE Engineering Summary Phil Heitzenroeder for the FIRE Engineering Team Presented to the FIRE Physics Validation Review Committee March 30, 2004.
Chapter 1 Stress.
LARP QXF 150mm Structure Mike Anerella / John Cozzolino / Jesse Schmalzle November 15, nd Joint HiLumi LHC-LARP Annual Meeting.
CTC / MTC 222 Strength of Materials Final Review.
Multiple Coil Lift Calculation. Purposes of the Study  To investigate the stress distribution in the MCWF and the lifting device.  To make sure mounting.
Proposed TF Joint Design C Neumeyer 2/26/9 Notes: 1)Several concepts included are based on ideas developed by R Woolley 2)No analysis has yet been performed.
Analyses of Bolted Joint for Shear Load with Stainless Steel Bushing and Frictionless Shim-Flange Interface Two cases of shim plates were investigated.
NSTX TF Flag Joint Design Review INTRODUCTION C Neumeyer 8/7/3.
NSTX TF Flag Joint Design Review OVERVIEW C Neumeyer 8/7/3.
NSTX Center Stack Upgrade Workshop Requirements & Design Point C Neumeyer Jan 22, 2009.
Section XI Keys, Pins, & Splines.
LBNL CCD Packaging “Yale Mount” Mechanical Analysis Dan Cheng LBNL.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus February 24, 2010 PF3 Dome Bracket 1/8 inch Weld Stress PF4,5 Stress with 6 Support.
NSTXU-CALC TF Flex Joint and TF Bundle Stub
LHC Phase II Collimator Compact jaw simulations New FLUKA => ANSYS mapping scheme New 136mm x 950mm jaw –60cm primary collimator –Helical cooling channel.
Sag of ZTF components Callahan 9/4/2014. Corrector Trim Plate analysis.
Modular Coil Assembly Bolted Joint PDR 2/22/07. Objectives The review objectives include... Define the location of additional inboard bolts Finalize the.
1 FEA an aid in - the short story - Find out how the load is transmitted, from application to reaction. Are there stiff paths and soft paths ? Are the.
NCSX Modular Coil Joint Load/Stress Calculation By Leonard Myatt Myatt Consulting, Inc.
TF Joint Operations Review Introduction C Neumeyer 2/10/05 Scope and Outline of Review Summary of Findings from 2004 Run Review of Joint Force, Pressure.
ITER In-Vessel Coils (IVC) Interim Design Review Thermal Structural FEA of Feeders A Brooks July 27, 2010 July 26-28, 20101ITER_D_353BL2.
1 Bolts in Tension pt1 Andrei Lozzi. The flanges at the end of the two turbine shafts seen above, are bolted together to form a very rigid friction coupling.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus January 27, 2010 Umbrella Leg Sliding Blocks TF OOP Support to the Vessel Seismic (Static.
An Analysis of Shell Structure for Dead Load H.M. Fan PPPL September 16, 2005.
Analyses of Bolted Joint for Bolt Preload and Shear Load
Peer Review NSTX TF Hub Assembly Friction Coating C Neumeyer 10/27/04 Requirements Testing Calculation Update Implementation.
Figure 1 – NSTX Upper Umbrella Assembly Upgrade Design: Version 3.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus April 14, 2010 PF4/5 Terminal Stress Existing PF4/5 Support Weld Algorythm Moment Influence.
TF Joint Operations Review Commissioning Plan C Neumeyer 2/10/05 Test Shots Instrumentation Benchmarking.
1 MC Assembly over the VV FPA Station 3 FDR Review July 13, 2007 T. Brown.
NSTX TF Flag Joint Design Review SUMMARY C Neumeyer 8/7/3.
TF Joint Operations Review Simplified Modeling & Protection C Neumeyer 2/10/05 IP and OOP Load Modeling Linear Model of IP and OOP pressure at Joint FEMLAB.
BoltJoin ppt P. Rogoff 3/24/2011. NSTX Supported by P. R. 3/9/2011 Update Ring Bolted Joint Design and Recommend the Joint Geometry using bolts.
Proposed TF Joint Design Concept #1 C Neumeyer 3/23/9 Notes: 1)Several concepts included are based on ideas developed by R Woolley 2)No analysis has yet.
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus March Insulation Short Beam Tests – Failure Modes Ripple Loads on PF PF4/5.
Nonlinear Analyses of Modular Coils and Shell structure for Coil Cool-down and EM Loads Part 1 – Results of Shell Structure and Modular Coils H.M. Fan.
NSTX TF Flag Joint Status of Design, Analysis, Test Activities & Design Review Preparations C Neumeyer NSTX Team Meeting 7/24/3.
AWB NSTX TF Flag Joint Design Review April 10, 2003 Art Brooks.
A View of NCSX Structural System and Load Path for the Base Support Structure.
Final_Bellows.ppt. The purpose for these analyses was to justify and select the appropriate NSTX Center Stack Update project VV Bellows. The bellows should.
CAD and Finite Element Analysis Most ME CAD applications require a FEA in one or more areas: –Stress Analysis –Thermal Analysis –Structural Dynamics –Computational.
REQUIREMENTS & ASSUMPTIONS C Neumeyer 4/10/3. FIELD AND CURRENT Base GRD requirement: 3kG at R 0 =0.854m with 4.5 sec flat top, once every 300s
NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus March F.
A PROPOSED TF JOINT DESIGN FOR THE NSTX CENTERSTACK UPGRADE Robert D Woolley 25 February 2009.
Engineering Operations Outage Schedule The vessel & beamline are under vacuum. 1st Bake-out complete. Air leaks found and fixed. The OH coil will be installed.
Preliminary Analysis of TF Joint Behavior* C Neumeyer NSTX Team Meeting 2/12/4 *Summary from 1/29/4 Presentation.
NCSX Modular Coil Joint Load/Stress Calculation By Leonard Myatt Myatt Consulting, Inc.
TS Cool Down Studies TSu Unit Coils (24-25) N. Dhanaraj and E. Voirin Tuesday, 10 March 2015 Reference: Docdb No:
NSTX TF Flag Joint Design Review OVERVIEW C Neumeyer 8/7/3.
Working group meeting 07/05/15. Agenda Overview of review and current action list Relief system – Summary of problem – Details of analysis, testing and.
Shafts and Shaft Components
Presentation transcript:

NSTX TF Flag Joint Torque Collar Chit Review C Neumeyer 9/11/3

BACKGROUND Four chits from the August 7 review expressed concern regarding the torque collar design… TITUS: The shear capacity of wet lay-up is based on test and a fine mesh model. Either Irv should have a local model with a similar fine mesh or the 1.6 factor from the test FEM should be ignored. NELSON: Concern about welding ears to torque collar – distortion, heating, etc. Suggest mock-up to confirm feasibility. NELSON: Concern is shear lag at gaps. Recommend analysis of current design and continuous design, thicker bond line, more gaps, etc. ANDERSON: Build mock-up of collar and test for shear failure due to temperature and torsion.

Initiated FEA of collar… -discovered problems not only with shear lag at gaps but also stress concentrations and excessive variations in compression due to lack of vertical symmetry FEA Model of August 7 Collar Design

Pursued several variants before arriving at a design which…. fits in the available space can be installed despite the limited access allows access to the box bolts limits shear in wet lay-up to acceptable values - analysis and testing not yet finalized Latest Design Keys for torsion, free for vertical and Radial motion Inconel Struts Threaded Connectors Anchor Bushings Anchor Pins

In parallel, FEA cases have been run for collar-less design -no significant structural impact in removing collar -changes in joint pressure and resistance pattern result in a shift in the current distribution, but temperature impact is not severe -peak temperature at joint ~ 10 o C higher than cases with collar Review of original FEA indicates that collar benefit to turn-turn insulation shear is not required to meet allowable -collar reduces peak insulation shear by 17% -Peak shear under worst case conditions without collar would increase from 2.2 to 2.7ksi -Allowable is 2.9ksi which includes a safety factor of 2 against R&D tests at 600psi compression

Analysis shows that collar-less design meets all requirements Advantages of Collar… 10 o C peak temperature benefit 17% turn-turn shear stress benefit Restraint against clocking of bundle, in addition to friction Disadvantages of Collar… Additional complexity of assembly Reduced access to box bolts Thermal induced stresses Potential cost/schedule risk

NEW STRATEGY… 1)Continue design/analysis/test of collar and bring to closure 2)Do not implement collar initially, except for anchor pins 3)Perform measurements during next run to confirm analysis Operations to be initiated at low Bt (~ 3kG) Level to be increased only as justified by measurements 4)Implement collar in future if measurements are not favorable

PURPOSE OF REVIEW Obtain critique of collar-less strategy Preview new collar design but defer review to a later date if necessary

ANALYSIS OF SOFT COLLAR-LESS CASE Caselost contact area <1000 psi contact pressure 6kG w/collar4%9% 6kG w/o collar15.6%21.3%

PRESSURE & RESISTIVITY WITH COLLAR Note: Data interpolated from uniform pressure during rampup to SOFT and during Flattop, then held fixed at EOFT values thru EOP

PRESSURE & RESISTIVITY W/O COLLAR Note: Data interpolated from uniform pressure during rampup to SOFT, then held fixed at SOFT values thru EOP SOFT assumption is conservative

Add 15 o C For Bolt Hole Effect, Tmax = o C

With CollarWithout Collar Note: Contour values not equal CURRENT REDISTRIBUTION Current finds path of least resistance Much of joint is inactive

SUMMARY Design meets allowables without collar -Conservativism still remains All PF coils at max current for full time duration 0.7 sec flat top T=120 o C Collar increases margins, but adds risk and complexity Strategy to defer collar is the best to pursue at this time

NEW COLLAR STATUS Design is in-hand -Fabrication drawings being generated from Pro-E CAD model Analysis is essentially complete - SOFT, EOFT, EOP cases - Safety factor calculation based on extrapolation up to ~ 8ksi of shear strength from prior database with compression up to 2ksi Testing is underway to determine wet lay-up shear at high compression

NEW COLLAR DESIGN

FEA OF NEW COLLAR DESIGN Scotchply & CTD Hysol Insulation 3-total applied Torque =0.25M lb-inch angular motion fixed

Compression Twist Shear (Torque) Axial Shear (Thermal) Combined Shear TYPICAL FEA RESULT (SOFT)

SAFETY FACTOR CALCULATION Shear_VectorSum = {(Shear_angular) 2 + (Shear_long) 2 } 0.5 Shear_Allowable = 28MPa(4ksi) + 1.3*|Compression| Safety_Factor = Shear_Allowable / Shear_VectorSum

FEA SUMMARY TABLE Pressure on insulation angular shear on insulation z-direction shear on insulation Safety factor with compress. dT=17 degree with Torque 0.25M[lb-inch] 4~57MPa (0.6~8.1ksi) ave. ~25MPa 15MPa (2.1ksi) 5MPa (0.7ksi) 2.6 dT=54 degree with Torque 0.25M[lb-inch] 9~52MPa (1.3~7.4ksi) ave. ~25MPa 29MPa (4.1ksi) 14MPa (2.0ksi) 1.8 dT=72 degree without Torque 11~45MPa (1.6~6.4ksi) ave. ~25MPa 28MPa (4ksi) 18MPa (2.6ksi) 1.9