F ERMI N ATIONAL A CCELERATOR L ABORATORY C RYOGENIC D EPARTMENT 2015 CRYOGENIC ENGINEERING CONFERENCE – Tucson, AZ L. PEI, J. THEILACKER, A. KLEBANER,

Slides:



Advertisements
Similar presentations
Introduction What is the PCIMS ? PCIMS :Process Control Information Management System Each plant as an individual process area shall consist of an integrated.
Advertisements

Automation and Drives WinAC – the SIMATIC S7 in your PC News Q1/2004.
Automation and Drives Applications with IE/PB Link  Verticale integration using engineering tools like SIMATIC PDM or Drive ES  Remote diagnostic / remote.
BEPCII Cryogenic Control Gang Li IHEP, Beijing,China.
Operated by the Southeastern Universities Research Association for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Page 1.
Cryogenics at CERN (LHC)&Helium Inventory Brief review with emphasis given on cryogen management Americas Workshop on Linear Colliders 2014 Fermilab,
1 Process Control and Data Acquisition Systems CM4120 Chemical Plant Operations.
February 9, 2002 Muon Collaboration Technical Board Michael Iarocci E951 Cryogenics1 Cryogenic Cooling System for the E951 Pulsed Solenoid Magnet Basic.
EPICS on TPS RF System Yu-Hang Lin Radio Frequency Group NSRRC.
Distributed Control Systems Emad Ali Chemical Engineering Department King SAUD University.
Introduction What is the PCIMS ? PCIMS :Process Control Information Management System Each plant as an individual process area shall consist of an integrated.
ADAM-5000/TCP- Distributed Ethernet I/O
SIMATIC New Generation Controllers S7-1200
Current status Arkadiy Klebaner November 21, 2012
SCADA and Telemetry Presented By:.
1. 2 How do I verify that my plant network is OK? Manually: Watch link lights and traffic indicators… Electronically: Purchase a SNMP management software.
CASIPP Design of Cryogenic Distribution System for CFETR CS model coil Division of Cryogenic Engineering and Technical Institute of Plasma Physics Chinese.
II World Wide Pasta Congress Venezuela October 2000 PAGE 1 Totally Integrated Automation SIEMENS in the Pasta Plants Competence in Pasta Plant Automation.
Production visibility: KPI’s in Real-time BASF – The Chemical Company
SCADA FOR WATER DISTRIBUTION IC DEPT. GECGn SEC28.
Progress Report on CGSE Control System Project Team of SJTU for AMS-02 Yang Yupu AMS JSC, Jan 8-12, 2007.
MTA Cryogenics: Where We Are The Work of Fermilab AD/Cryo Barry Norris, Christine Darve and a host of wonderfully talented Cryogenic Personnel John Thompson,
EPICS Collaboration Meeting Spring 2010, Aix France, Jun 2, 2010 Page 1 ITER CODAC COntrol, Data Access and Communication System for ITER Anders Wallander.
NCSX NCSX Preliminary Design Review ‒ October 7-9, 2003 G. Oliaro 1 G. Oliaro - WBS 5 Central Instrumentation/Data Acquisition and Controls Princeton Plasma.
ITER – Interlocks Luis Fernandez December 2014 Central Interlock System CIS v0.
Drag and Drop Display and Builder. Timofei B. Bolshakov, Andrey D. Petrov FermiLab.
CLS Machine Protection and PLC Hardware Presentation to Beamlines Group Elder Matias Canadian Light Source University of Saskatchewan October 20, 2001.
Control & Monitoring System Update Contributors: Brian Martlew - Daresbury Laboratory - STFC James Leaver - Imperial College Pierrick Hanlet - Fermilab.
Unit 5 CONTROL CENTERS AND POWER SYSTEM SECURITY.
Topics of presentation
André Augustinus 17 June 2002 Technology Overview What is out there to fulfil our requirements? (with thanks to Tarek)
Cryo AIP Muon Campus AIP Review Arkadiy Klebaner January 23, 2012.
FAIR Accelerator Controls Strategy
LHC Cryogenics Control: INTEGRATION OF THE INDUSTRIAL CONTROLS (UNICOS) AND FRONT-END SOFTWARE ARCHITECTURE (FESA) APPLICATIONS Enrique BLANCO Controls.
1 UNICOS PVSS Evolution Cryogenics Control Enrique BLANCO Industrial Controls & Electronics Group.
S. Claudet - 31st May 2007Power refrigeration for LHC Power refrigeration at 4.5K & 1.8K for the LHC S. Claudet, CERN AT-ACR.
The (prototype) C&V Framework component used for the SPD Cooling Control A.Tauro, G.De Cataldo.
Process Definition of the Operation Modes for Super-FRS Magnet Testing CSCY - CrYogenic department in Common System, GSI, Darmstadt Y. Xiang, F. Wamers.
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
The (prototype) C&V Framework component used for the SPD Cooling Control A.Tauro, G.De Cataldo.
CMTF Infrastructure Jerry Leibfritz PIP-II Machine Advisory Committee 9-11 March 2015.
ITER Liquid Helium Plants Status and Test Protocol ICEC June 29th, 2015 / Grenoble / FranceY. FABRE.
PIP-II Cryogenics Arkadiy Klebaner and Jay Theilacker PIP-II Collaboration Meeting 9 November 2015.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
NML Cryogenic System Arkadiy Klebaner Cryomodule One Commissioning June 3, 2011.
17-18 December 2013 LARP VTF Workshop BNL Proposal 1 A.Marone
CMTF Cryogenics (status and plans) SRF program and AD/Cryogenics work presented by Arkadiy Klebaner May 21, 2013.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
PXIE Cryogenics Concept Arkadiy Klebaner Session 5 / WG1 (CW Linac and PXIE) October 26 th, 2011.
CMTF Cryogenics Arkadiy Klebaner May 6, Outline CMTF cryogenic system scope Goals Key functional requirements Conceptual layout Cryoplant Current.
JLab Accelerator Controls Matt Bickley MaRIE discussion April 26, 2016.
HIE ISOLDE commissioning of the cryogenic control system installation at CERN. LNL-INFN 22/07/2015 Dr. Marco Pezzetti (CERN )
Project X Workshop - Cryogenics1 Project X CRYOGENICS Arkadiy Klebaner.
Danish Ali Nawaz 1CLIC workshop 2016 Danish Ali NAWAZ, BE-ABP LEETCHI: Drive Beam Electron Source Automation Control.
Fermilab Control System Jim Patrick - AD/Controls MaRIE Meeting March 9, 2016.
An overview of I&C Systems in APR 1400 Parvaiz Ahmed Khand December 28, 2007.
Development of Cryo-Module Test Stand (CMTS) for Fermi Lab (R.L.Suthar, Head,CDM, BARC) Cryo-Module Test stand (CMTS) is a very sophisticated equipment.
Redundancy in the Control System of DESY’s Cryogenic Facility. M. Bieler, M. Clausen, J. Penning, B. Schoeneburg, DESY ARW 2013, Melbourne,
Lesson 3 SCADA.
Process Simulation for the LCLS-II Cryogenic Systems
Dana M. Arenius Jefferson Laboratory Cryogenics Dept Head
BDS Cryogenic System RDR Status and EDR Plans
How SCADA Systems Work?.
ILC Experimental Hall Cryogenics An Overview
Charge 2. Equipment Protection 3. Definition and Documentation
Operator Training Requirements
Piping and Instrumentation for Process Industries
Ola Ingemansson Electrical & Instrumentation Engineer
Operation of Target Safety System (TSS)
Conceptual design of the Cryogenic System of Comprehensive Research Facility for Key Fusion Reactor Core Systems Liangbing Hu Sep.4.
Presentation transcript:

F ERMI N ATIONAL A CCELERATOR L ABORATORY C RYOGENIC D EPARTMENT 2015 CRYOGENIC ENGINEERING CONFERENCE – Tucson, AZ L. PEI, J. THEILACKER, A. KLEBANER, W. SOYARS, R. BOSSERT FERMILAB MUON CAMPUS CRYOGENIC DISTRIBUTION REMOTE CONTROL SYSTEM ABSTRACT The Muon Campus (MC) is able to measure Muon g-2 with high precision and comparing its value to the theoretical prediction. The MC has four 300 KW screw compressors and four liquid helium refrigerators. The centerpiece of the Muon g-2 experiment at Fermilab is a large, 50-foot-diameter superconducting muon storage ring. This one-of-a-kind ring, made of steel, aluminum and superconducting wire, was built for the previous g-2 experiment at Brookhaven. Due to each subsystem has to be far away from each other and be placed in the distant location, therefore, Siemens Process Control System PCS7-400, Automation Direct DL205 & DL05 PLC, Synoptic and Fermilab ACNET HMI are the ideal choices as the MC g-2 cryogenic distribution real-time and on-Line remote control system. This paper presents a method which has been successfully used by many Fermilab distribution cryogenic real-time and On-Line remote control systems. CONCLUSIONS The CM1 cryogenic system is working on its schedule with the successful commissioning of several subsystems, including the Warm compressor systems, inventory control system, refrigerator system and PCS remote distribution cryogenic control system. The commissioning of the cryogenic distribution system leading to the new Muon g-2 test will soon be underway followed by full commissioning of the Muon g-2 system. The main goal of the Muon g-2 experimenters is to test the Standard Model's predictions of this value by measuring the precession rate experimentally to a precision of 0.14 parts per million. If there is an inconsistency, it could indicate the Standard Model is incomplete and in need of revision. room and MC1 helium cryogenic refrigeration, which is provided by four onsite Tevatron style of cryogenic plants. The warm compressors located at A0 Compressor Building are four MyCom brand 300KW compressors shown on the Figure 2. The cryogenic refrigerator plant is shown on the Figure 3; there are four reciprocating dry expanders and four reciprocating wet expanders. They will supply liquid helium to Muon g-2 and Mu2e solenoids. The CM1 also houses Muon g-2 solenoids ring as shown on the Figure 4. Muon g-2 solenoids maximum cryogenic heat loads is liquefaction load ~ 1.4 [g/sec] and refrigeration load ~ 300 [W]. And Muon Mu2e solenoids maximum cryogenic heat loads is liquefaction load ~ 0.8 [g/sec] and refrigeration load ~350 [W]. Tevatron style satellite refrigerators maximum theoretical capacity is liquefaction ~ 4.2 [g/sec], refrigeration ~625 [W]. The Cryogenic System is expected to operate for 20 years with an estimated shutdown period of one month every year. The Cryogenic System shall support simultaneous steady state operation of both experiments, Muon g-2 and Mu2e. It shall provide for independent operation of the two experiments, including transient, refrigeration, liquefaction, warm-up and cool down mode, etc. DISTRUBITION REMOTE CONTROL SYSTEM The Muon Campus 1 cryogenic system utilizes Siemens Process Control System 7 (PCS 7) controls. Its main control system consists of the Siemens System SIMATIC PCS 7 which is an integral component of Totally Integrated Automation (TIA); TIA is a unique platform for unified and customer-specific automation system. The similar control system has been successfully used for many years at Fermilab to control other cryogenic systems, e.g. CMTF. Simplified schematics for the CM1 cryogenic control system is shown on Figure6. The multi-level distribution remote control system uses Siemens Engineering Station (ES) as its operation level; SIMATIC NET IE as its OPC (Object Linking and Embedding(OLE) for Process Control) server; Fermilab Synoptic HMI system as its Web operation and monitor level; Fermilab ACNET (Accelerator Control Network) as its archive, monitor and alarm level. The Siemens PCS7-400 PLC acts as the central control PLC and four ET200Ms act as remote data acquisition and field I/O that are linked to the controls PCS PLC through the field control bus PROFIBUS DP. There are fifteen Automation Direct DL205/DL06 PLCs by KOYO® as its remote independent sub-control field system. Among them, six DL205s are used as local control PLCs for compressor operation, inventory management and real-time interlock protection; eight DL06s are used as local control PLC for engine operation and real-time interlock protection. The DL205s/DL06s communicate to the PCS7-400 controls PLC through one DL205 configured as a gateway PLC. The PCS7-400 central control PLC handles with all PID LOOP control, signal conversion and logic control as well as communication between Fermilab ACNET and PCS7-400 and DL205s/DL205s. Fiber Media Converters MC) and Scalance Ethernet Switches (SW) are used at various locations to integrate different parts of the system. The CM1 PCS7-400 central control PLC, ET200M I/O and Scalance Ethernet switch are shown on Figure 7. The control of the localized equipment such as the 300 KW MyCom compressors, four reciprocating dry expanders and four reciprocating wet expanders are done using localized, self-contained, and PLC based sub-controls system which communicate directly with the PCS7 system using the fiber optic line. The localized PLCs interface with the equipment motor controller and manage the machine local interlocks. A local touch panel display allows for manipulation and control of these systems. The top layer HMI is Synoptic graphic user interface from Sun-Microsystem JAVA. PCS7 parameters are sent to the Fermilab ACNET through SIMATIC NET IE OPC server. The Synoptic system is a graphical interface between Fermi ACNET and the end user which uses graphical tools to display and manipulate the cryogenic process. Synoptic also supports alarm handling and plotting packages. The Muon Campus cryogenic control system is fully protected by safety relief valves and system configuration and in no way relies on the operation of the controls system. The controls system is used to automate the various processes through a network of control loops and logic and acts only as a secondary, supplemental safety system INITIAL COMMISSIONING Over the last half year some key components of the CM1 cryogenic system have been successfully commissioned, it including the warm compressors as well as the inventory control system. During the commissioning, four 300KW MyCom compressors are operating as show on Figure 8. INTRODUCTION Fermilab Muon g-2 experiments will examine the precession of muons that are subjected to a magnetic field. The main goal is to explore rare sub-atomic processes and make precision measurements, test the Standard Model's predictions of this value by measuring the precession rate experimentally to a precision of 0.14 parts per million. The Muon Campus experiments 1(MC1) will house the cryogenics plant as well as the 50 foot wide Muon g-2 superconducting particle storage ring. The experiments utilize superconducting magnets that require cryogenic services. A cryogenic system to provide these services consists of four Tevatron Satellite refrigerators, four compressors, a cryogenic distribution system, and an axillary system necessary for the cryogenic system operation. One of the buildings (A0), will house the noisy vibrating equipment (four compressors) needed to operate the cryogenic plant. The other building will contain the cryogenic plants with four Tevatron Satellite refrigerator systems, Muon g-2 electromagnet ring and an office area. The current plan is for the MC facility to completing reassembly of all the magnet components. Soon, the coils will be cooled to near absolute zero with liquid helium so that the superconducting magnet can undergo tests and commissioning. The MC test will be used to assess the cryogenic plant performance prior to their commissioning. A layout of the entire Muon Campus facility complex is shown in Figure 1. Figure 1. Layout of Muon Campus Experimenter Figure 2. A0 Warm Compressor Room TEST FACILITY DESCRIPTION The cryogenic test facility is composed of A0 compressor Figure 3. CM1 Four Tevatron style satellite refrigerators Figure 4. CM1 Muon g-2 solenoids ring Figure 6. MC Cryogenic Control System Network Layout Figure 7. The CM1 PCS7-400 central controller, ET200M I/O and Scalance Ethernet switch Figure 8. Four A0 compressors operation status is shown up by Synoptic HMI Figure 9. CM1 Muon g-2 refrigerator management is shown up by Synoptic HMI Figure 5. CM1 Muon g-2 solenoids ring on traveling The inventory pneumatic control valves PVHS, PVLS and PVLB are shown on the FIGURE 8 is available to maintain pressure while compressor flow will be changed with loading valve. We used PCS PID LOOP control to regular discharge pressure PT2 at 275 psig and suction pressure PT1 at 1.5 psig. All high sliders of four compressors are set up at 100% by Synoptic HMI manual setting while compressor running. M1 Mu2e refrigerator system is operating as show on Figure 9. The sustainable capacity of a single Tevatron satellite refrigerator is either: ~50 W at 4.5 K in refrigerator mode or of ~3.7 g/s of liquid helium at atmospheric pressure in liquefaction mode. The next phase of commissioning will include cooling down the installing Muon g-2 and Mu2e in the future.