Advanced Studies Institutes

Slides:



Advertisements
Similar presentations
LHC/HERA workshop, WG 4 (17. Jan. 2005)
Advertisements

K.Eggert/CERN TOTEM Physics  tot elastic scattering diffraction (together with CMS) Karsten Eggert CERN, PH Department on behalf of the TOTEM Collaboration.
P. 1Mario Deile – DIS 2004 Mario Deile CERN on behalf of the TOTEM Collaboration TOTEM: Forward Physics at the LHC.
April 22, 2006 DIS2006 XIV International Workshop on Deep Inelastic Scattering Tsukuba, Japan, 20-24/April/ TOTEM: Early Diffractive Physics at the.
The TOTEM Experiment at the LHC  Physics program  Detector overview Giuseppe Latino (University of Siena & Pisa INFN) (on behalf of the TOTEM Collaboration)
Diffraction at LHC - Experimental set-up Risto Orava University of Helsinki and Helsinki Institute of Physics 0.1 Low-x Workshop Antwerpen R.Orava 17.
LHCf: a LHC Detector for Astroparticle Physics LHCf: a LHC Detector for Astroparticle Physics Lorenzo Bonechi on behalf of the LHCf Collaboration * University.
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC K. Österberg High Energy Physics Division, Department of Physical Sciences,
Machine induced background in ALFA The ALFA detector elastic scattering and luminosity background generation, rejection and subtraction impact on luminosity.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
DISTRIBUTED CRYOGENIC COOLING WITH MINIATURIZED FLUID CIRCUITS Steffen Grohmann, ETT/TT RD39 Collaboration ST Workshop 2003 CERN, April 01-03, 2003.
The BTeV Tracking Systems David Christian Fermilab f January 11, 2001.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
Jornadas LIP, Dez P. Martins - CFTP-IST The NA60 Silicon Vertex Telescopes Dimuon measurements Dimuon measurements Vertex telescope used in: Vertex.
G. Ruggiero/TOTEM 1 The TOTEM Experiment T1 Telescope (CSC) T1 Telescope (CSC) T2 Telescope (GEM) T2 Telescope (GEM) Roman Pots (Si Edgeless detect.) Roman.
Gueorgui ANTCHEVNEC’2013 – Varna, Bulgaria 1 The TOTEM Experiment Consolidation and Upgrade G. Antchev * On behalf of the TOTEM Collaboration * INRNE-BAS,
The First 1 ½ Years of TOTEM Roman Pot Operation at the LHC M. Deile, G. Antchev, I. Atanassov, V. Avati, J. Baechler, K. Eggert, J. Kašpar, F. Lucas Rodriguez,
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
Matti Ryynänen NOKIA μstation design philosophy - mechanical positioning and vacuum chamber separated - all parts in beam vacuum μstation cluster.
HAMBURG BEAM PIPE POSSIBLE LAYOUT AND MANUFACTURING JANUARY 2012.
Stefano Lami INFN Pisa on behalf of the TOTEM Collaboration.
1 Tehniline ülevaade uusimast füüsikast CERN’is Endel Lippmaa 20. Detsember 2006, TTÜ.
ATLAS Forward Detector Trigger ATLAS is presently planning to install forward detectors (Roman Pot system) in the LHC tunnel with prime goal to measure.
Installation and operation of the LHCb Silicon Tracker detector Daniel Esperante (Universidade de Santiago de Compostela) on behalf of the Silicon Tracker.
Barrel RPC Chamber consists of 2 double-gaps, each equipped with a common plane of 96 strips read-out by 6 front-end boards. The two double- gaps have.
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
LHCb VErtex LOcator & Displaced Vertex Trigger
AFP Introduction September 10th 2014 M. Bruschi, INFN Bologna (Italy) 1.
Planar Edgeless Silicon Detectors for the TOTEM Experiment 1.E-09 1.E-06 1.E /T, 1e3/K Current, A (294K) (256K)(227K)(204K) Gennaro Ruggiero,
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
P. 1Mario Deile – Meeting on Experiment Protection from Beam Failures Protecting TOTEM Mario Deile PH-TOT
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
P. 1K. Eggert – Early TOTEM Running with the  * =90m Optics Karsten Eggert on behalf of the TOTEM Collaboration Politecnico di Bari and Sezione INFN Bari,
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
Karsten Eggert / PENN State - p. 1 Karsten Eggert CERN / PH Proton Detection at IP3 Enlarge the acceptance for diffractive protons to lower  p/p ~ 10.
The LHCb Vertex Locator Lars Eklund LHCb VELO Group of the LHCb Collaboration CERN (Geneva), EPFL (Lausanne), NIKHEF (Amsterdam), University of Glasgow,
Status of the TOTEM Experiment and Latest Results
Gennaro Ruggiero CERN, PH Depart. Planar Edgeless Detectors for the TOTEM Experiment On the behalf of the TOTEM Collaboration
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
D.Macina TS/LEATOTEM Meeting25/02/2004 Roman Pot test at the SPS Test of the Roman Pot prototype in the SPS proposed in December 2003 (CERN/LHCC ):
Technical Design for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC V. Avati University of Helsinki on behalf of the TOTEM Collaboration
Proposal for Microstation Prototype Jaak Lippmaa CERN 2005.
Diffraction at LHC (How to turn LHC into a 14 TeV Gluon Factory ?) stolen from Risto Orava University of Helsinki and Helsinki Institute of Physics Workshop.
Integration of forward physics detectors into the LSS of the LHC D. Macina (TS/LEA) Technical Support 2004 Workshop.
Status of the Experiment RRB - TOTEM 16 April 2013 S.Giani - CERN on behalf of the TOTEM Collaboration CERN-RRB
Developing Radiation Hard Silicon for the Vertex Locator
Xth Blois Workshop on Elastic and Diffractive Scattering
Jaak Lippmaa HIP, Helsinki University
First data from TOTEM experiment at LHC
Emmanuel Tsesmelis TS/LEA 26 January 2007
Simulated vertex precision
Strawman module design
Recent Results from TOTEM
TOTEM early measurements
(with R. Arcidiacono, A. Solano)
Planar Edgeless Silicon Detectors for the TOTEM Experiment
5% The CMS all silicon tracker simulation
The digital read-out for the CSC system of the TOTEM experiment at LHC
The Pixel Hybrid Photon Detectors of the LHCb RICH
LHCb VErtex LOcator For precision measurements of CP-violation at CERN (GENEVE) HALF of DETECTOR Si strip detector Read-out electronics Secondary vacuum.
TOTEM experiment at the LHC
Vertex Detector Overview Prototypes R&D Plans Summary.
On behalf of the TOTEM Collaboration:
The digital read-out for the CSC system of the TOTEM experiment at LHC
Status of CMS-PPS timing detectors
The LHCb VErtex LOcator
Results, Status and Perspectives for 2011
Presentation transcript:

Advanced Studies Institutes Physics at LHC Prague 6-12 July 2003 The TOTEM Experiment Karsten Eggert CERN, EP Division on behalf of the TOTEM Collaboration http://totem.web.cern.ch/Totem/

Collaboration Università di Bari and Sezione INFN, Bari, Italy Institut für Luft- und Kältetechnik, Dresden, Germany CERN, Geneva, Switzerland Università di Genova and Sezione INFN, Genova, Italy Institut des Sciences Nucléaires, IN2P3,/CNRS, Grenoble, France University of Helsinki and HIP, Helsinki, Finland Warsaw University of Technology,Plock, Poland Academy of Sciences, Praha, Republic Czech Brunel University, Uxbridge, UK

The measurement of stot Historical : CERN Tradition (PS-ISR-SPS) Dispersion relation fit (logs)g , g=2.20.3 (better fit today 2.0) Current models predictions: 100-130mb Aim of TOTEM: ~1% accuracy Absolute calibration of Luminosity

~150m ~215m Optical Theorem

T1 Inelastic telescope Track chambers CSC Cathode strip read-out for vertex reconstruction 5 planes on each telescope Space resolution better than 0.5mm Trigger by RPC Two double gap chambers Pad read-out with projective geometry Time resolution ~1ns T1 telescope η~3.1 to 4.7 on each side

RAILS ARE ASSEMBLED ON A TRUSS STRUCTURE, TO WITHSTAND THE FLEXURAL LOAD THE TRUSS IS COMPLETELY RESTRAINED ON THE OUTERMOST SPACER RING PUSH/PULL RODS AT THE END TIE THE 2 TRUSSES AND LIMITS THE TORSION BASIC SOLUTION: STEEL MADE, ONE TRUSS WEIGHS ROUGHLY 120 Kg PUSH ROD: COULD BE MADE OF ALUMINIUM OR FIBERGLASS (BETTER PARTICLE TRANSPARENCY) AND/OR ARC-SHAPED PUSH/PULL RODS TRUSS

T1 telescope simulation T1 description in ORCA (CMS OO simulation) Distribution of fitted tracks extrapolated to the collision plane. The circle indicates the actual beam pipe diameter

5.3 < h < 6.7 on each side Lost events: < 1% T2 Silicon detector in front of CASTOR 5.3 < h < 6.7 on each side 13570 400 T1 and T2 and the forward Roman pots allow fully inclusive trigger (including diffraction). The trigger will be a two side coincidence : (T1 or T2) left X (T1 or T2) right (T1 or T2) left X (proton in RP) right (proton in RP) left X (proton in RP) right Lost events: < 1% acceptance for diffractive protons: >90 % independent of x=Dp/p

Lightweight Structure Space for services  470 mm Bellow Thermal Insulation Weight estimation: ~30 Kg 400 mm

Charged particle fluxes Hits per plane hits Charged Particle Fluxes for a luminosity of 1028 at T1 1.5 Hz/cm2 at T2 40. Hz/cm2 (1. plane) with beam pipe Totem only ( old ) Radiation hardness T1 can operate for a few years at L=1032 T2 can operate for a few years at L=1033 with beam pipe

Elastic scattering Impact picture and Regge models TOTEM goals: measure t-distribution to lowest possible t (t~10 –3 GeV2 ) extrapolation to t=0 with a precision of <0.5% measure over largest possible t-range (t ~10 GeV2)

TOTEM Optics Conditions LTOTEM ~ 10-6 x 1034 cm-2 s –1 ~ 1028 cm-2 s –1 TOTEM needs special/independent short runs at high-b* (1500m) Scattering angles of a few mrad High-b optics for precise measurement of the scattering angle q* = e / b* Reduced number of bunches to avoid interactions further downstream s* =  e b* Parallel-to-point focusing: Trajectories of proton scattered at the same angle but at different vertex locations

High b optics: lattice functions vx(1100) vy(1100) vy(1540) vx(1540) v= (b/b*)1/2 cos m(s) L = (bb*)1/2 sin m(s) Ly(1100) Lx(1100) Lx(1540) Ly(1540)

Elastic Scattering acceptance b* = 1100 m b* = 1540 m

t acceptance for the two proposed optics acceptance dependence on detector position t=0.004 GeV2 A=44% t=0.01 GeV2 A=67% b=1100m b=1550m t=0.004 GeV2 A=64% t=0.01 GeV2 A=78%

and t – resolution versus the azimuthal angle f assumed detector resolution 20 mm df (rad) s(t)/t

t-resolution (one and two arms) versus detector resolution beam angular divergence =0 total s(t)/t (1 arm) v dependence! s(t)/t (2 arms) coplanarity

Errors on the extrapolation to t=0 Beam angular divergence sq=(e / b*)1/2 Optical functions Beam position Crossing angle Detector resolution: statistics and systematics (detector offset) RP station alignment Background (beam halo, double pomeron exchange…)

Elastic Cross section (t=0): stat. and syst. errors L=1028 cm-2 s-1 run time = 4 . 104 sec 10mm detector position uncertainty

Large t scattering Ldt = 1033 1037 cm-2 1 eff.day (105sec) at high b and 18 m -t(GeV2) 15/GeV2 2.104/GeV2 Ldt = 1033 1037 cm-2 b*=1540m b*=18m ds/dt (pp) (mb/GeV2) (M. Islam)

Detector requirements High and stable efficiency near the edge facing the beam, edge sharpness < 10 mm Try to do better than present technology guard rings ~0.5 mm Detector size is ~3x 4 cm2 Spatial resolution ~20 micron Systematics ~ 20 micron Moderate radiation tolerance (~1014 n /cm2 equiv) ~3cm CMS Hybrid

Cold Silicon RD39/NA60 have investigated/used silicon at cryogenic temperatures (~ 100-130 K) Studies hint at possibility of operating silicon microstrip without guard rings at LN temp. K.Borer et al., “Charge collection efficiency of irradiated silicon detector operated at cryogenic temperatures” NIM A 440 (2000) 5. L.Casagrande et al.,"A new ultra radiation hard cryogenic silicon tracker for heavy ions beams“ NIM A (2002) 325-329. S.Grohman et al., “Detector development for TOTEM Roman Pots”, IX Blois Workshop on El. and Diff. Scatt., Pruhonice, Czech Republic, (2001), 363. In 2002 we have performed a first measurement on cold edgeless silicon detector Z. Li et al, "Electrical and TCT characterization of edgeless Si detector diced with different methods", IEEE NSS Proc., San Diego, Nov. 2001

Reconstruction of the cut edge Hits in the telescope (all good tracks) Hits in the cut detector Efficiency Edge at: 0+20micron

Development with planar technology cut edge p+ n+ A B C n+ ring (20 mm) at 30mm from p+ set at the same pot as backplane hope: n+ ring stops the C current B under control with temperature test of various configuration this summer goal: increase working temperature p+ n+ A B D

PLANAR-3D DETECTORS i Edge sensitivity ~20 mm TRADITIONAL PLANAR DETECTOR + DEEP ETCHED EDGE FILLED WITH POLYSILICON p + Al E-field n + Al i n + Al signal a.u. position [mm] Edge sensitivity ~20 mm Leakage current =6nA at 200V Brunel, Hawaii, Stanford

3D DETECTORS AND ACTIVE EDGES Brunel, Hawaii, Stanford EDGE SENSITIVITY <10 mm COLLECTION PATHS ~50 mm SPATIAL RESOLUTION 10-15 mm DEPLETION VOLTAGES < 10 V DEPLETION VOLTAGES ~105 V at 1015n/cm2 SPEED AT RT 3.5 ns AREA COVERAGE 3X3 cm2 SIGNAL AMPLITUDE 24 000 e before Irradiation SIGNAL AMPLITUDE 15 000 e- at 1015n/cm2 15 mm InfraRed beam spot FWHM = 772 mm Edge Al strip width = 16 mm INSENSITIVE EDGE (INCLUDING 16 mm Al STRIP): (813 - 772) / 2 = 21 mm CERN Courier, Vol 43, Number 1, Jan 2003

3D response to particles Brunel, CERN, Hawaii, Stanford Pulse height Small bias 5-8 V Speed 1.5, 3.5 ns Radiation hardness MIP MIP Ileak = 0.45 nA (average) 200 mm Ileak = 0.26 nA (average) 100 mm C = 0.2 pF per electrode 1x1015 p/cm2 20oC

Design of the Roman Pot is focused on three main phases: Design of the Pot Design of the Roman Pot Station Integration in the Tunnel Main items: Secondary Vacuum : outgassing and RF shielding Mechanical Design of a thin window Integration of detectors inside the pot: mounting, cooling Design of a flange to routing the detector’s services outside the pot High mechanical precision ( < 20 mm) and reproducibility

Welding on a flat foil and folding

Radiation length Xo (mm) deformation (m) 0.1 mm Inconel 718 1 atm.   Density (Kg/m3) Young Modulus (GPa) Yield Strength (Mpa) Radiation length Xo (mm) Aluminum 6063 2800 72 250 89 Stainless Steel 316L 8000 200 280 17.6 Copper 8900 110 152 14.3 Beryllium IF-1 1900 303 300 350 Titanium 6AL4V 4700 1100 35.6 Inconel 718 7800 1050 stress Pa

Thin window Technology issues Brazing: Inconel looses ~30% of the strength Low limit on the thickness of the joints Brazing inside the pot -> dead space window Pot Brazing Electro erosion: Low Yield of material Increase of Porosity Bottom of the pot flat -> no dead space Both technologies are available at CERN and must be tested on prototypes

Prototyping and Test of the Pots at CERN (July 2003) Brazing test on Folded Inconel Foils Production of 5 window prototypes to be tested under pressure TEST procedures Cycling load 0bar/1bar -> no permanent deformations Thermal test cycling from RT to 300oK with and without pressure load -> no permanent deformations Increasing of the pressure till rupture to define the ultimate load 1 Pot Prototype for RF Pick up test on electronics Production of 1 mock-up of the pot with dummy detectors to have a full integration exercise with the services

Conceptual Design of the Roman Pot detector CMS Tracker Hybrid 3cm Thermal analysis

Cryogenic Cooling (F.Haug, AT/ECR) Two main options: local cooling or passive elements Active local cooling system Passive system : Heatpipes, Peltier Cells (preferable solution) Cold source at 80oK -> pulse-tube (no vibrations) Other systems as Joule-Thompson nitrogen flow are under investigation QRL transfer line of LHC machine = NO ! Heat loads ~12 watt/pot > 230oK 2 Watt few mWatt DT ~ 5oK Heatpipe ~ 1500mm DT ~ 20oK 130oK 80oK Pulse tube

TOTEM Test Beam Read/Out Hybrid ~RT Liquid Nitrogen Reservoir (77oK) Kapton Pitch Adapter (Thermal bridge) Vacuum Vessel Edgeless Detector (130oK)

Pot with Secondary Vacuum Reference Pin Carbon Fiber Frame APV25 Cooling contact Pitch Adapter x-y Module Silicon Sensor 40mm x 40 mm Precision Reference Pin Forward Proton Thin window 0.1mm : Secondary vacuum + RF shielding

Flange with double sided D-Connectors PCB cards Cooling Flat cables Connectors D-Connector Flange with double sided D-Connectors Flange with feeding through PCB cards

What has been done for the Roman pot system: Two solutions have been designed: Symmetric distribution of the loads but less favorable access for maintenance Not symmetric loads but optimized access For Both solutions A compensation system based on external vacuum pumps allows for a fine regulation, releasing the force on the pots A capacitive system accounting the relative position of the top-bottom pots, Integration of two Roman Pot stations between the TAN and D2

Roman Pot Device (Second Version) Compensation bellow Pot Lever Arm Capacitive sensor Roman Pot Device (Second Version)

Horizontal Roman Pot Station Measuring and cross-calibration purpose LHC Beams

QRL (LHC Cryogenic Line) 4m

Roman Pot Station (made of two RP devices) Collimator QRL BPM TAN Racks Roman Pot Station (made of two RP devices)

LHC Impedance requirements impose small resistivity and small volumes: Impedance Issues LHC Impedance requirements impose small resistivity and small volumes: when the Roman pots are close to the beam in data taking mode the estimated impedance is 0.1 mW and it is by far lower than the impedance budget allowed for the machine 250 mW , assuming a pot in Steel. Operation restriction for near-beam detectors: Image Current -> heat deposited on the pot by ohmic heating RF Fields -> noise induced on the detectors and the electronics Both are related to LHC bunch structure: for TOTEM special runs -> 36 bunches 2 ms spaced

A novel detector for measuring the leading protons - the Microstation - is designed to comply with the LHC requirements. a compact and light detector system integrated with the beam vacuum chamber geometry and materials compatible with the machine requirements mm accuracy in sensor movements robust and reliable to operate Si strip or pixel detector technology Development in cooperation with the LHC machine groups M.Ryynänen, R.Orava. /Helsinki group

Microstation Inch worm motor Emergency actuator 6cm Detector Inner tube for rf fitting 6cm Space for cables and cooling link Detector Space for encoder Note: A secondary vacuum is an option. M.Ryynänen, R.Orava. /Helsinki group

Radiation background on the Roman Pot (D.Macina, N.Mokhov) Assumptions: Simulation has been done from IP5 to Q7 (v. 6.4,  = 0.5 m) Peak luminosity is L=1034 cm-2 s-1 Absorbed dose is normalized to : 180 days, 24 hours per day, <L> = 0.5 · 1034 cm-2 s-1, equivalent to 6.22·1015 non-elastic events per year Results: Accumulated radiation dose around the RP is ~ 103 Gy/yr Annual Fluence of Hadrons on the tunnel ground~109cm-2 Radiation hard components (cooling, local triggers, power supplies…..) are required

Radiation fluence in the RP silicon detectors (N. Mokhov,I Radiation fluence in the RP silicon detectors (N.Mokhov,I. Rakhno,Fermilab-Conf-03/086) Maximum fluence (1014 cm-2) for charged hadrons (E>100 KeV , L= 1033 cm-2 s-1, t=107s): RP4 (215 m)  Vertical: 0.58, Horizontal: 6.7 Dose (104 Gy/yr) RP4 (215 m)  Vertical: 0.37 (max: 1.9), Horizontal:1.2 (max:55) Main source of background: pp collisions Tails from collimators and beam-gas scattering ~ 0.1-1% Radiation level manageable

Interactions with the machine Design and construction of the Roman pots together with EST Tests and production of the prototypes Risk analysis of the secondary vacuum and of the operation LHC impedance requirements Radio frequency shielding Integration and services into the tunnel Choice of the cryogenic cooling system for the Silicon detectors LHC vacuum requirements: NEG coating and bake-out at 300 K

To measure the total cross section with ~ 1% precision total inelastic rate within 1 % extrapolation to t=0 within 0.3-0.4 % Near Future plans: Optics optimization Tests of different forward detectors Choice of a cryogenic cooling system First Roman pot prototype for the end of 2003

CMS/TOTEM is the largest acceptance detector ever been built at a hadron collider TOTEM+CMS+ CASTOR For the first time at a collider large acceptance detector which measures the forward energy flow 1 day run at large beta: 10 million minimum bias events, including all diffractive processes 90% of all diffractive protons are detected New phenomena are expected in the very forward cones (cosmics)

Total TOTEM/CMS acceptance (b*=1550m) microstation at 19 m ? RPs

Total TOTEM/CMS acceptance (b*=18m) RPs

Diffraction at high b* x<10-3 x=0.06 x=0.01 -t=10-1 -t=10-2 log(-t) (GeV2) >90% of all diffractive protons are seen in the Roman Pots proton momentum can be measured with a resolution of ~10-3

Double Pomeron Exchange M2=x1x2s p M (GeV) x1= x2 CMS/TOTEM collaboration for high luminosity diffractive physics b* = 0.5 m Trigger via Roman pots x > 2.5 10-2 Trigger via rapidity gap x < 2.5 10-2 x=Dp/p proton momentum loss

Future CMS/TOTEM plans: Diffraction Dissociation (High Luminosity) RP4 (215 m) RP5 (300 m) RP6 (340 m) RP7 (420 m) b* = 0.5 m acceptance x = Dp/p

Running scenario Total Cross Section and Elastic Scattering Runs with single beams (calibration + background) Several 1 day runs with b*=1550m (CMS Magnet On/Off) Several 1 day runs with b*=18m for large-t elastics Diffraction Runs with CMS (active trigger or passive ) with b*=1550m for L =1028cm-2 s-1 Runs with CMS (active trigger or passive ) with b*=0.5m for L < 1033cm-2 s-1

consolidation of the collaboration! Plans: test of Si detectors (2003-2004) Roman Pot prototype end 2003 trigger studies (2003-2004) TDR end 2003 consolidation of the collaboration! CMS/TOTEM collaboration for high luminosity diffractive physics