Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall.

Slides:



Advertisements
Similar presentations
Coriolis Technology.
Advertisements

Composite Filament Winding Machine: P09226 Shijo George Christofer Brayton Alex Sandy Tiago Santos Daniel Weimann Project Manager Electrical Engineer Chief.
Control System Instrumentation
Physiological Simulator
LVAD is a battery-operated, mechanical pump-type device that's surgically implanted. Goal of LVAD: providing the patient with as close to a normal lifestyle.
Greg Hyde Raymond Zheng Joseph Rojano Katie Bentley Lori Liebman P14414 P3 ARBORLOO WIND RESISTANCE TEST STAND DETAILED DESIGN REVIEW 1.
ENTC 303: Fluid Mechanics and Fluid Power
P08026: Modular Hemodynamic Flow Simulator Jason Brown Mechanical Engineering Amanda Clark Mechanical Engineering Matthew Hicks Electrical Engineering.
Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall Week 3:  Progress Update  Specifications 
Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall Week 4 Presentation:  Selected Concepts  Engineering.
Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall Week 2 Presentation:  Work Breakdown Structure.
Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall Week 4 End of Day Presentation:  Design Review.
Risk Scoring Parameters Severity (choose most severe) Risk Ranking Likelihood ProductProjectInjury 3 Highly Likely > 50% Complete product failure, does.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
Reservoir LVAD PVS / Booster Physiological Simulator Valve Automated Resistance Valve Three Loops Blood Extraction Standard Pressure Sensor Temperature.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Statics CEE 331 June 29, 2015 CEE 331 June 29, 2015 
Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall Week 2 – End Of Day:  Progress Update  Concept.
Ventricle Chamber Valve Imaging Chamber ECG Machine Aortic Compliance Chamber Buffer Chamber Secondary Compliance Chamber Flow Meter Pressure Sensors DAQ.
Statics CEE 331 July 14, 2015 CEE 331 July 14, 2015 
Jon Klein Project Manager Kyle Menges Technical Lead Priya Narasimhan Electrical Engineer Julie Coggshal Industrial and Systems Engineer Christine Lowry.
Control System Instrumentation
Classification of Instruments :
Chemical Engineering 3P04 Process Control Tutorial # 2 Learning goals 1.The feedback cause-effect principle 2. Key element in the loop: The control valve.
What does blood have in it? In pairs quickly come up with a few ideas on what you think blood consists of Write these ideas on your show me board You have.
Muhajir Ab. Rahim School of Mechatronic Engineering
Lease Automatic Custody Transfer
Process Control: Designing Process and Control Systems for Dynamic Performance Chapter 1. Introduction to Process Control Copyright © Thomas Marlin 2013.
In Engineering --- Designing a Pneumatic Pump Introduction System characterization Model development –Models 1, 2, 3, 4, 5 & 6 Model analysis –Time domain.
Jon KleinISEProject Manager Nguyen VuMETechnical Lead Kyle MengesMETechnical Lead Christine LowryMEDesign Engineer Chris SteinMEDesign Engineer Priya NarasimhanEEElectrical.
BLOOD VESSELS WHAT ARE BLOOD VESSELS? Blood vessels are intricate networks of hollow tubes that transport blood throughout the entire body.
Copy and complete: The blood from the lungs enters the ______ ______. Then it gets moved down to the _______ _____. Then it gets squeezed out to the ______.
IT 264 INDUSTRIAL FLUID POWER Chapter 2 Physical Properties of Hydraulic Fluids.
INTRODUCTION TO CONTROL SYSTEMS
The oven given in the figure is heated with a heat source having the heat flow rate Q. The total heat capacity of all objects in the oven is C and the.
Mike Allocco, Soham Chakraborty, Leslie Havens, Danielle Koch, Andrew Miller, Kristeen Yee, Stephanie Zambito TEAM 14026: SYSTEM DESIGN REVIEW P14026_System.
Control System Instrumentation
Jon KleinISEProject Manager Nguyen VuMETechnical Lead (MSD1) Kyle MengesMETechnical Lead Christine LowryMEDesign Engineer Chris SteinMEDesign Engineer.
P16081: SYSTEMIC CIRCULATION MODEL Jacob Zaremski – Lead Engineer Mallory Lennon – Project Manager John Ray – Communications Manager Fabian Perez – Purchasing.
Nanofluidic Characterization David Sharp David West Justin Davis.
Surface Tension. Compliance Curve Review -- Muscle Elastic and Active Forces.
CHAPTER 9 Control System Instrumentation
Development of a Murine Perfusion System Nicola Asgill Fredrick Hilliard George Kittos.
REVIEW VASCULAR SYSTEM. ANSWER THE FOLLOWING QUESTIONS 1.What are the 4 components of blood? 2.What are the 5 types of blood vessel? 3.Draw a diagram.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
MISS. RAHIMAH BINTI OTHMAN
Date of download: 6/7/2016 Copyright © ASME. All rights reserved. From: Mock Circulatory Loop Compliance Chamber Employing a Novel Real-Time Control Process.
Instrumentation I - Session 5 Session 5 - Agenda ActivityEst. Time 1. Agenda 2. Introduction to Primary Sensors, Transmitters and Transducers (Chapter.
FRP company proprietary 1 ; Apr-98 Coriolis Technology.
Ventricular Assist Device Test Loop Client: Minnetronix, Inc. Advisor: Kristyn Masters Team: Joe Bothwell, Dan Carlson, Kayla Ericson, and David Ugai.
بسم الله الرحمن الرحيم وبه نستعين
Author: Nurul Azyyati Sabri
Pressure Measurements
Unit 11: Calibrating Instruments
Midpoint Project Review P10454 VAD Test Loop
Date of download: 10/9/2017 Copyright © ASME. All rights reserved.
Refrigeration & air conditioning
Control System Instrumentation
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Controllers and Positioners
Date of download: 11/15/2017 Copyright © ASME. All rights reserved.
Circulatory System.
SB Packing Automatic Downpuller Power Unit
Figure 21.1 A Comparison of a Typical Artery and a Typical Vein
Control System Instrumentation
Prepared by Dr. Mohamed Ahmed Awad
CE 230-Engineering Fluid Mechanics
Control System Instrumentation
Active Reciprocating Compressor Valve Assembly P16452
Control Loops: Primary Sensors, Transmitters, and Transducers - Agenda
Heart Pump and the Circulatory System P17080
Presentation transcript:

Team Members: Jon Klein Nguyen Vu Kyle Menges Christine Lowry Chris Stein Priya Narasimhan Julie Coggshall

Purpose Project Objectives Team Roles and Responsibilities Customer Needs and Specifications Expectations System Concept: Mechanical and Electrical Blood Sub-System Elements: Air Removal, Blood Extraction Dynamic Sub-System Elements: Compliance Chambers Static Sub-System Elements: Materials, Automated Resistance Electrical Elements: Flow, Pressure, and Temperature Sensors, DAQ Conclusions Pg.1

Design and build a test loop to help in LVAD development by characterizing the pressures and flows associated with the device as well as its impact on blood. Pg.2

1.Generate pressure and flow curves for static system (automatically adjusted) 2. Extracting fluids while running to determine damage to blood 3. Process data to generate pressure and flow curve for dynamic system (scaled model of the physiological circulatory system working with a PVS) Pg.2

Jon Klein Project Manager Kyle Menges Technical Lead Priya Narasimhan Electrical Engineer Julie Coggshall Industrial and Systems Engineer Christine Lowry Design Engineer (ME) Chris Stein Design Engineer (ME) Nguyen Vu Technical Lead Pg.2

Pg.26

Pg.3-4

To review the following material in order to gain input based off of attendees’ experience.

Pg.5

Pg.7

Pg.6

Subsystem Rank 123 TubingTygonABSMetal ResevoirBagsGravity DrivenOpen Top Valves3 Way Stainless3 Way PlasticNo Valves ComplianceTanksElastic MaterialMembrane Tanks ResistancePressure CuffServo Controlled ClampClamp Blood ExtractionThree Way ValvePressure Sensor TubingDouble Check Valve Pressure SensorsIntrusive DifferentialIntrusive DisposableSuspended Transducer Flow SensorsUltrasonic Clamp-onIntrusive PTFE Temperature SensorsThermocoupleInfrared Temperature ControlHeat ExchangerHot PlateWater Bath Leak TestTracer-FluidPressure Decay/FlowBubble Test See Concept Selection Matrix for full analysis

N RISK Air bubbles cannot be removed from system9 System or components leak causing error in measurement and/or contamination 4 Pg.23

N RISK Method for keeping constant temperature (98 deg F) not within budget 4 Human body temperature is not maintained 4 Blood is damaged due to the heating process 6 Viscosity variation does not simulate human blood properties 2 Pg.18-19

Venous Vein Less elastic Thin wall Does not help drive flow Arterial Resistance Figure 1: Artery and Vein Graphic Artery More elastic Thick wall Helps drive flow P Pressure Gage Air Valve Figure 2: Compliance Tank Drawing Air Resistance Cuff N RISK Resistance Automation 6 Specified compliance values not achieved 4 Flow restriction does not function properly 3 System or components leak causing error in measurement and/or contamination 4 Pg.12-16

Resistance Calculations V air =Volume of air in tank A tank = Cross sectional area of tank V tank =Volume of tank P fluid =absolute pressure of fluid Tank size Calculations = density of fluid g=Acceleration due to gravity C= Compliance P air =absolute pressure of air Source: University of Virginia Article, Design Initial testing of a mock human circulatory loop to test LVAD performance Source: Berne R. etal Physiology 4 th edition Mosby, St Louis 1998 N Pg.13

PVC Valves Stainless Steel Valves N RISK System or components leak causing error in measurement and/or contamination 4 Valves, sensors, tubing degrade over time2 Not all components are biocompatible 4 Valves, sensors, connectors damage blood 9 Pg.21

N RISK Desired sensor accuracy not within budget 6 Pressure and flow measurements are inaccurate 2 Instrumentation and DAQ not communicating properly, DAQ does not collect or output data properly 6 Pg.8

N RISK Desired sensor accuracy not within budget 6 Pressure and flow measurements are inaccurate 2 Instrumentation and DAQ not communicating properly, DAQ does not collect or output data properly 6 Pg.9

N RISK Desired sensor accuracy not within budget 6 Pressure and flow measurements are inaccurate 2 Instrumentation and DAQ not communicating properly, DAQ does not collect or output data properly 6 Pg.10

N RISK Dedicated DAQ system not within budget 6 Instrumentation and DAQ not communicating properly, DAQ does not collect or output data properly 6 Pg.11

N