A Presentation ON NTPC ANTA POWER PLANT submitted in partial fulfilment for the award of the degree BACHELOR OF TECHNOLOGY IN Department of Electrical.

Slides:



Advertisements
Similar presentations
Introduction to Electrical Machines
Advertisements

Understanding the Alternator
ELECTRICAL POWER AC MOTOR & DC MOTOR.
ELECTRICAL POWER AC MOTOR & DC MOTOR.
Chapter 13 AC Motors. Chapter 13 AC Motors Objectives Discuss the operation of an induction motor. Identify and explain the operation of various three-phase.
Chapter 33 Charging System Fundamentals.
AC Machine.
Lesson 33 AC Generators.
Course Coordinator Prof. Suneet Tuli Presented by- Rupali Gupta (2012TTE2398) M.Tech 1 st Year Textile Engineering.
THE GENERATOR 3. Generators are used to provide large scale power production.
Three-Phase ac Voltage Generation
Electric AC Motor Vigyan Ashram, Pabal.
1.4b Charging System 1. Charging System Function of the charging system 2 Convert mechanical energy into electrical energy Recharge battery Provide higher.
TURBINE & COOLING SYSTEM Presented By – AVIJEET PRATAP 07ME12 IET AGRA
AC MOTOR INDUCTION MOTOR.
Three-Phase AC machines
Introduction to Electrical Machines
Department of Electrical and Computer Engineering
Motor ELECTRICAL ENERGY Mechanical Energy.
Chapter 2 Transformers.
Gas Turbine Power Plant
PRESENTATION ON INDUCTION MOTOR
CHARGING SYSTEM Major Parts Battery                                               Alternator Regulator.
Chapter 19 AC Motors.
Electric Motors MECH1200 TO THE TRAINER
Induction Motors Prepared By : PRAGNESH, MEET, SAGAR, SAAVAN, KANISH
Induction Motors.
Chapter 5. Electric Machines.
1 Motors and Generators ©Dr. B. C. Paul More Fun with Flux Mechanically Rotated Shaft Slip Rings Wires with brush contacts to slip rings Electromagnetic.
Unit 2 -Gas And Diesel Power Plants
Understanding the                                                                                                                                                                                                                          
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
Chapter 5. Synchronous Machines.
Chapter 16: Synchronous Generators
Electric Machine Introduction
DC Machines and Drives . Books
Gas Turbine Power Plant
Magnetic field due to an electric current
A Presentation On 132 KV GSS BEHROR
A Presentation On Construction Of Turbo Generator
INDUCTION MOTOR.
A Presentation on construction of Turbo Generator.
UNIT – II ELECTRICAL MACHINES.
UNIT 17: TYPES OF ELECTRIC MOTORS
AC Motors AC current reverses direction Two parts: stator and rotor
L I NGAYA'S INSTT. OF MGT. AND TECHNOLOGY, FBD. THERMAL POWER PLANT OVERVIEW.
Induction Motor (Asynchronous Motor)
Electrical Motor1 3 Phase Induction Motor Mrs R.U.Patil Sr.Lecturer,EPS Dept. V.P.M’s Polytechnic,Thane.
Gas Turbine Power Plant
Chapter 13 – AC Motors AC motors convert AC electrical energy to Mechanical energy.
THREE-PHASE INDUCTION MOTOR
Electric Motors and Generators
Understanding the Alternator
Speed control of three phase induction motor
Topics covered in this presentation:
Electric Machine Induction Motor
AC Motors AC motors convert AC electrical energy to Mechanical energy.
Electric Machine Introduction
INDUCTION MOTOR.
Induction Motor. Induction motor Main parts are Stator Rotor.
BASIC MECHANICAL ENGINEERING
Energy Conversion and Transport George G. Karady & Keith Holbert
Why is starter necessary for a three-phase induction motor?
Motors 3 phase Induction Motor.
Principle of Operation
EET 323 – Electrical System Design Lecture 13: Motor Circuits
Electric Machine Design Course
Presentation transcript:

A Presentation ON NTPC ANTA POWER PLANT submitted in partial fulfilment for the award of the degree BACHELOR OF TECHNOLOGY IN Department of Electrical Engineering

Introduction on NTPC Ltd.  NTPC ltd. is the largest power generating company of India.  A public sector company, it was incorporated in the year 1975 to accelerate power development in the country as a wholly owned company of the government.  Total installed capacity of NTPC Ltd. Is 43,128 MW.  15 coal based(24,395 MW).  3 gas based(3,955MW).

Power Evacaution from NTPC Anta  Power Lines Bhilwara  Two Lines for Jaipur  One Line for Kota and  One Line for Rawatbhata Power Plant

Gas Turbine Gas turbine is a heat engine. The process includes:-  Compression:- Drawing air into the engine, pressurizing it and then feeding it to combustion chamber.  Combution: Typically made of a ring of fuel injector that inject a steady steam of fuel into combustion chamber where it mixes with the air. The combustion produces a high temperature and high pressure gas steam that enters and expands through the turbine.

Expansion :- Of the product of combustion in a turbine. Start-up of the GT:- Start-up of the GT is driven with the help of starting equipment which runs the generator as a motor with speed increasing from 0 to 600 rpm. At this speed piolet flame ignited in combustion chamber, fuel (gas/naphtha) enters and combustion take place.

Start-up of the Gas turbine The speed increases further both with the help of generator motoring and the combustion of the fuel up to about 2000 rpm. At this speed starting equipment is switched off and only the generator is made ready for synchronisation with the grid. After synchronizations, the turbine load increases up to base load with more and more fuel entering the combustion chamber.

Application of Gas Turbine Conventional applications are:-  Simple Cycle Operation  Combined Cycle Operation  Electric utility companies use gas turbine predominantly in simple cycle and combined cycle applications.  Combined cycle operation is much efficient than open cycle operation.

Simple Cycle operation A simple cycle operation turbine is a type of gas turbine most frequently used in the power generation, aviation(jet engine) and oil and gas industry (electricity generation) and mechanical drives.

Combined Cycle Power plant The Combustion Turbine:- Natural gas is mixed with air and burned in the combustion chamber to create the high pressure gasses needed to spin a turbine. This part of the plant is a single cycle combustion turbine. These are sometimes called CTs. CTs are normally designed to meet peak loads. The Combined Cycle Power Plant:- A combined cycle power plant is a dual cycle power plant. The “2 nd ” part of the combined cycle is a heat recovery unit. It takes advantage of the energy in the exhaust gases to create steam. The steam spins a turbine to generate electricity. The combined cycle plants are normally designed to meet base and intermediate loads.

Heat Recovery Steam Generator

Waste Heat Recovery Boiler Heat Recovery Steam Generator (HRSG) have found application in a wide range of industries where the co-generation of steam and electricity is required, in order to obtain an independent power plant and negligible emission levels.

Transformer A transformer is a device that transfer electrical energy from one circuit to another through inductively coupled electrical conductor. A changing current in the first circuit(the primary) creates a changing magnetic field, in turn this magnetic field induces a changing voltage in the second circuit(the secondary). By adding a load to the secondary circuit one can make current flow in the transformer, thus transferring energy from one circuit to the another.

Basic Principle:- The transformer is based on two principles: firstly that an electric current can produce a magnetic field (electromagnetism) and secondly that a changing magnetic field within a coil of wire induces a voltage across the ends of the coil (electromagnetic induction). By changing the current in the primary coil, it changes the strength of its magnetic field; since the changing magnetic field extends into the secondary coil, a voltage is induced across the secondary.electric current magnetic fieldelectromagnetismelectromagnetic induction

Types of transformer:-  Autotransformer  Polyphase Transformer  Resonant Transformer  Leakage Transformer  Instrument Transformer Construction of Transformer:-  Laminated Iron Core  MS Tank  Radiator Fins  Conservator  Silicon Gel Breather  H.T. bushing

Continue:-  L.T. Bushing  Buchholtz Relay  Transformer oil  Tap Changer  Level indicator  H.T. and L.T. winding  Explosion Vent

Method of Cooling Transformer  AN (Air Natural) Cooling media  AF (Air Forced) A = Air  ONAN (Oil Natural Air Natural) G = Gas(C 2 F 6 )  ONAF (Oil Natural Air Forced) L = Synthetic Oil (Silicon Liquid)  OFAN (Oil Forced Air Natural) S = Solid Insulation  OFAF (Oil Forced Air Forced) O = Mineral Oil  ONWF (Oil Natural Water Forced) W = Water  OFWF (Oil Forced Water Forced)

Protection System of Transformer:-  Buchhclotz Relay  Earth Fault or Leakage Protection  Overload Protection and Combined Leakage  Differential System and circulating current system  Pressure Relief Device Preventive Maintance of Transformer :- It can be categorized as hourly, daily, quarterly, half yearly, yearly, 5 yearly :-  Hourly Inspection: - Checking of winding temperature, oil temperature & load on HT & LT side.

Continue:- Daily Inspection : - Checking of oil level in transformer & tap changer, relief vent (explosion vent) diaphgram color of silica gel. If white/pink, then replace & HT and LT voltage and suitable adjustment through tap changer if required. Quarterly Inspection: - Checking of bushings for cracks and dirt deposits. Clean & replace if necessary, dielectric strength of oil and its water content, radiator fans, pump bearings, on load tap changer driving mechanism, gear box oil level, contacts, oil level in breather, top up oil if necessary and replace burnt or worn out contact. Half Yearly Inspection: - Checking on load tap changer (OLTC) and driving gears mechanism, clean, adjust and replace contacts and brake shoe etc.

Yearly Inspection:-  Testing of transformer oil for acidity, water content, dielectric strength & Tan Delta & filter if necessary.  Measurement of insulation resistance & compare with the value at the time of commissioning.  Tighten all gasketed joints e.g. tank cover, radiators.  Check all relays, alarm contacts & their operation. Five Yearly Inspection:-  Over all inspection by lifting of core & coils, washing them with clean, hot dry oil tight all nuts & bolts, on LT bus bar.  Painting of transformer externally.  Dehydration & filtration of oil (It has to be done 1 ½ to 2 year intervals).

Motor  Electromechanical device that converts electrical energy to mechanical energy.  Mechanical energy is used to: Rotate pump impeller, fan, blower Drive compressor Lift materials  Motors in industries are used as 70% of electrical power.

Working of Motor:-

Types of Motor Electric Motors Alternating Current (AC) Motors Direct Current (DC) Motors SynchronousInduction Three-PhaseSingle-Phase Self ExcitedSeparately Excited SeriesShuntCompound

AC Motor:- Electrical current reverses direction Two parts: stator and rotor Stator: stationary electrical component Rotor: rotates the motor shaft Speed difficult to control Two types:- Synchronous motor Induction motor

Components of Motor Rotor:- Squirrel cage:-Conducting bars in parallel slots. Wound rotor:-3-phase, double-layer, distributed winding. Stator:- Stampings with slots to carry 3-phase windings. Wound for definite number of poles.

AC Motor:- Synchronous motor Constant speed fixed by system frequency DC for excitation and low starting torque: suited for low load applications Can improve power factor: suited for high electricity use systems Synchronous speed (Ns) F = supply frequency P = number of poles Ns = 120 f / P

Induction Motor Three-phase induction motor:- Three-phase supply produces magnetic field Squirrel cage or wound rotor Self-starting High power capabilities 1/3 to hundreds HP applications: pumps, compressors, conveyor belts, grinders 70% of motors in industry! Speed and slip:- Motor never runs at synchronous speed but lower “base speed” Difference is “slip” Install slip ring to avoid this Calculate % slip: % Slip = Ns – Nb x 100 Ns Ns = synchronous speed in RPM Nb = base speed in RPM

Generator Generator is the electromagnetic device that converts mechanical energy into elecrical energy. Construction of Generator:- A typical Generator has following main components.  Stator Frame comprising of casing and stator core  Rotor  Exciter Slip Rings and Brushes (not applicable for all designs)  Bearings and Bearing Pedestals  Cooling System  Other systems e.g. Static Frequency Converter for starting of gas turbine.

Name Plate Rating in Generator in NTPC Applicable StandardIEC Generator TypeWY18L-095LL Apparent Power135 MVA Terminal Voltage10.5 kV Rated Current7423 A Frequency50 Hz Speed3000 RPM Insulation Class (Stator and Rotor) F Type of CoolingAir Cooled No. of Phases3 Phases Excitation SystemSlip Rings with Brushes

THANKS