The Effect of Ratio of Meldola’s Blue to Carbon Powders and Carbon Paste on Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.

Slides:



Advertisements
Similar presentations
Capability of Immobilisation techniques and detection of Ab-Ag interactions by Eyad Hamad November 2010.
Advertisements

MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
The performance of novel solid state Thick-Film pH sensor for water quality sampling suitable for deployment in remote catchment areas is presented. The.
Hydrogen Peroxide Detection Using Biogenic and Synthetic MnO 2 Shu Feng, Jim Nurmi, Paul Tratynek Satya Chinni, Brad Tebo Department of Environmental and.
PH pH is a unit of measure which describes the degree of acidity or alkalinity (basic) of a solution. It is measured on a scale of 0 to 14. The formal.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
New electrode materials for H 2 O 2 New electrode materials for H 2 O 2 based sensors and biosensors Francesco Ricci 1, Carla Gonçalves 2, Giuseppe Palleschi.
Abstract Sibley School of Mechanical and Aerospace Engineering, Cornell University Researchers from Cornell University and the Cornell Lab of Ornithology.
Fabrication of a Microelectrode Array Biosensor Based on a Modified Enzyme-Chitosan Biocomposite Lorenzo D’Amico October 1, 2008.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Potentiometry and the Detection of Fluoride
Application: A novel, non-destructive method which provides characterization of the three-phase interface in both catalyst and diffusion layers, between.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ferrocene Yi-Sheng Wang ( 汪乙生 ), Ting-Li Lin ( 林庭立 ), Hau Lin ( 林浩 ) Department.
Dynamics and Steady States of Two Chemostats in Series Due to the contamination of the biochemical waste, the techniques of waste treatment have been applied.
Ionic Liquids: A New Class of Sensing Materials Linlin Zhao Bioanalytical Chem, Spring 2007, UConn.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
An Introduction to Volumetric Analysis
Carbon Nanotubes as Biosensors ME 695 Yang 11/30/2004.
PH In the Laboratory. Ionization of Water Equllibrium Constant, K eq.
Titration Graphs. KeMsoft062 Strong Acid - Strong Base Investigating the titration between: 1M HCl and 1M NaOH.
Introducti on Objectiv e Experimenta l section Results and discussion Conclusio ns.
An Analysis of Dynamics of the Prey-Predator Interaction in a Chemostat Wen-Ke Su ( 蘇文柯 ), Chung-Min Lien ( 連崇閔 ), Hau Lin ( 林浩 ) Department of Chemical.
Preparation of the Carbon Paste Electrode Modified with Ferrocene and Its Applications to Detection of Hydrogen Peroxide and Glucose Yi-Sheng Wang ( 汪乙生.
Fig. 1 The heating ways for DSC (a) non-isothermal; (b) isothermal analyses (a)(b) Study of Thermal Properties in Zr-Al-Cu-Ni Amorphous Alloy by Adding.
Surface charge development at the Barite-Water interface in NaCl media, from 15 to 50˚C Heather Williams and Moira K. Ridley Department of Geosciences,
Chapter 14 Acids and Bases. Chapter 14 Table of Contents Copyright © Cengage Learning. All rights reserved The Nature of Acids and Bases 14.2Acid.
Calcium carbonate (marble) hydrochloric acid carbon dioxide.
A Study of the Effect of Operating Potential on Detection of Hydrogen Peroxide for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao.
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
Advisor : Ru-Li Lin Advisee :Shih-Min Chen Southern Taiwan University of Science and Technology, Department of Mechanical Engineering, Tainan, TAIWAN Date.
NOVEL NON-CONDUCTING FILMSFOR INTERFERENCE-FREE ELECTROCHEMICAL SENSORS M. BADEA a, A. CURULLI b*, G. PALLESCHI a, S. KACIULIS c, A. MEZZI c a Università.
Professor: Cheng-Ho Chen Student: Jing-Mei Wang Reporting date: 2015 / 05 / 06.
A Study of Statistical Analysis of the Main Effects and Interaction Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
The Optimum Operating Conditions for Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min.
An Analysis of the Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min Lien.
The Operating Potential on the Sensitivity of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財.
Steady States and Dynamic Behavior of a Chemostat Shan-Cheng Chyou ( 仇善誠 ), Chung-Min Lien ( 連崇閔 ), Hau Lin ( 林浩 ) Department of Chemical and Materials.
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
The Effect of Stirring Rate on the Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chih-Ying.
An Analysis of Variance of Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao ( 蕭佳政 ), Chih-Ying.
Biosensors and Carbon Nanotubes
Synthesis and Characterization of a tri- metal catalyst used for the water electrolyzer and fuel cell NFL Lab.1 STUT, Mechanical Engineering SPEACH : En-Xian.
Reporter: Wen-Cheng Lin Teacher:Wei-Tung Liao. Outline Introduction Materials Experimental Results and discussion Conclusions.
Acids and Bases SNC2D. Some Properties of Acids  Sour taste  Water soluble  Very reactive  Conduct electricity  Can act as a catalyst  Corrosive.
The Detection of Glucose for the Carbon Paste Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chih-Ying Wu ( 巫致穎 ), Hau Lin.
The Operating Conditions for the Sensitivity of Detection of Hydrogen Peroxide for the Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao(
Application of the Screen Printed Planar Electrode Modified with Ruthenium Hexacyanoferrate to Glucose Biosensor Kuo-Hsiang Liao( 廖國翔 ), Chung-Min Lien(
Section 13 Analytical Voltammetry.
Chapter 2 Semiconductor Materials and Process Chemicals
1 Titrations (Review) In a titration a solution of accurately known concentration is added gradually added to another solution of unknown concentration.
The Effect of the Dilution Rate on the Dynamics of a Chemostat Chung-Te Liu ( 劉崇德 ), Chung-Min Lien ( 連崇閔 ), Hau Lin ( 林浩 ) Department of Chemical and.
S YNTHESIS AND CHARACTERIZATION OF C ROSS - LINKED CELLULASE ENZYME AGGREGATES (CLEA S ) BY ETHANOL AND ACETONE DESOLVATION TECHNIQUE Presentation by Jagdish.
BIOFABRICATION OF MEA GLUCOSE SENSORS Dry in air Ready for in vitro glucose detection (B) Chitosan biopolymer is electrodeposited on target electrode sites;
The pH on the Sensitivity of Detection of Hydrogen Peroxide for the Small Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chung-Min Lien ( 連崇閔.
Enhancement of Hydrogen Storage Capacity of Zeolite- Templated Carbons by Chemical Activation Muthukrishnan. I Sevilla, M.; Alam, N.; and Mokaya,
The pH on the Detection of Hydrogen Peroxide for Electrode Modified with Chromium Hexacyanoferrate Chen-Hsun Hu ( 胡真熏 ), Ting-Li Lin ( 林庭立 ), Hau Lin (
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chung-Min Lien ( 連崇閔.
PH meter Bushra mubarak. pH pH is defined as the negative logarithm of the hydrogen ion activity aH. Unit of measure which describes the degree of acidity.
A Study of Carbon Paste Electrode Modified with Platinum Particles and Ferrocene and Its Application to Glucose Biosensor Yi-Sheng Wang ( 汪乙生 ), Ting-Li.
Consider the reduction half reaction: M z+ + ze → M The Nernst equation is E = E ө + (RT/zF) ln(a) When using a large excess of support electrolyte, the.
Analytical biochemistry laboratory (BIOC 343) L. Nouf Aalshareef KAU- Biochemistry department Second semester 2013.
Introduction Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale,
Analytical Laboratory II
Unit 4 Rates, equilibria and further organic chemistry
RESULTS AND DISCUSSION
Chen-Hsun Hu (胡真熏) , Chih-Ying Wu (巫致穎) , Hau Lin (林浩)
NiO2 mediator in catalytic oxidation of 2-propanol on glassy carbon
s Changes: Cite figures under EIS
MileStone 2K19, SSBT Coet’s, Department of Chemical Engineering.
Presentation transcript:

The Effect of Ratio of Meldola’s Blue to Carbon Powders and Carbon Paste on Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chih-Ying Wu ( 巫致穎 ), Hau Lin ( 林浩 ) Department of Chemical and Materials Engineering, Southern Taiwan University 南台科技大學化學工程與材料工程系 ABSTRACT. The glucose and oxygen can be catalyzed by the glucose oxidase to produce the gluconic acid and hydrogen peroxide, and therefore, as the concentration of hydrogen peroxide can be determined, the concentration of glucose can also be determined. A study was conducted to use the Meldola’s Blue to modify the carbon paste electrode. Because the Meldola’s Blue possesses the excellent catalytic characteristic, it can be used with the graphite carbon powders which possesses the excellent conductivity to make the carbon paste electrode and to elevate the responding current of hydrogen peroxide. The responding current of hydrogen peroxide is detected in the phosphate buffer solution(PBS) and then the concentration of the hydrogen peroxide can be obtained and consequently, the concentration of the glucose can be determined. At 30 ℃, -300 mV operating potential, 500 rpm stirring rate and in 0.05 M phosphate buffer solution (PBS), the TB (Time Base) graphs for the carbon paste electrode at different ratios of Meldola’s Blue to carbon powders and carbon paste were plotted to evaluate the effect of the ratio of Meldola’s Blue to carbon powders and carbon paste on the responding current of detection of hydrogen peroxide. At the optimum operating conditions -300 mV operating potential, 500 rpm stirring rate and in 0.05 M PBS buffer solution ( pH = 7.4 ), when the carbon paste electrode was modified with Meldola’s Blue [Meldola’s Blue : carbon powders : carbon paste = 2 : 15 : 15 ( weight ratio )], the detection limit was 0.02 mM H 2 O 2, the linear range was 0.02 ~ 1.4 mM H 2 O 2, R 2 = , and the sensitivity was µA/cm 2 . mM H 2 O 2. Both the detecting techniques of hydrogen peroxide and glucose are important. The glucose and oxygen can be catalyzed by the glucose oxidase to produce the gluconic acid and hydrogen peroxide, and therefore, as the concentration of hydrogen peroxide can be determined, the concentration of glucose can also be determined. Because the Meldola’s Blue possesses the excellent catalytic characteristic it can be used with the carbon paste and carbon powders which possess the high conductivity to make the carbon paste electrode and to elevate the responding current of hydrogen peroxide. The responding current of hydrogen peroxide is detected in the phosphate buffer solution (PBS), and then the concentration of hydrogen peroxide can be determined. At 30 ℃, -300 mV operating potential, 500 rpm stirring rate and in 0.05 M phosphate buffer solution (PBS), the TB (Time Base) graphs for the carbon paste electrode at different ratios of Meldola’s Blue to carbon powders and carbon paste were plotted to evaluate the effect of ratio of Meldola’s Blue to carbon powders and carbon paste on the responding current of detection of hydrogen peroxide. The optimum operating conditions were used to detect the detection limit, linear range and sensitivity of detection of hydrogen peroxide for the carbon paste electrode modified with Meldola’s Blue. INTRODUCTION EXPERIMENTAL 1. Equipment Electrochemical Analyzer (CHI 401A, CH Instruments, Inc) was used to measure the activity of electrode by Cyclic Voltammetry ( CV ) and Time Base ( TB ) mode ; Oven (DENG YNG) ; Electric Stirrer(Fargo) ; pH meter (Metrohm 731); Constant Temperature Thermal Bath (Wisdom BC-2DT 10L); Carbon Paste Electrode was used as the working electrodes, Coiled Platinum Wire was used as the counter electrode and Ag / AgCl was used as the reference electrode. 2. Chemicals and Reagents Meldola’s Blue ; Hydrochloric Acid (HCl); Sodium Hydroxide (NaOH) ; Hydrogen Peroxide (H 2 O 2 ); Graphite Carbon Powder( C ); Carbon Paste; Cyclohexanone(C 6 H 10 O); Potassium Dihydrogenphosphate (KH 2 PO 4 ); Potassium Chloride (KCl). 3. Preparation of the Carbon Paste Electrode (1) Take one section of 7 cm electric wire with 0.05 cm inside diameter. After depriving the coating 0.5 cm length from both ends, the nake-ended wire was washed, dried and ready for use. 7 cm 0.05 cm 0.5 cm (2) Then the Meldola’s Blue powders, graphite carbon powders and carbon paste were mixed with the appropriate ratio [Meldola’s Blue : carbon powders : carbon paste = 2 : 15 : 15 ( weight ratio )]. After the mixing was complete, the mixture was evenly coated on the nake- ended electric wire and dried in the oven and then we obtained the carbon paste electrode. Meldola’s Blue Carbon Powders Mixing with Carbon Paste DEPARTMENT OF CHEMICAL AND MATERIALS ENGINEERING, SOUTHERN TAIWAN UNIVERSITY RESULTS AND DISCUSSION Table 1 The sensitivities, responding currents and R 2 values of different ratios of Meldola’s Blue to carbon powders and carbon paste for the carbon paste electrode modified with Meldola’s Blue Fig 1. CV graphs for (A) unmodified carbon paste electrode( the range of scanning potential: -0.8 ~ +0.8 V) (B) carbon paste electrode modified with Meldola’s Blue ( the range of scanning potential: -0.8 ~ +0.8 V) Fig. 2 The TB graphs of carbon paste electrodes for detection of H 2 O 2 at different ratios of Meldola’s Blue to carbon powders and carbon paste ; [Meldola’s Blue : carbon powders : carbon paste = (A) 0 : 15 : 15 (B) 1 : 15 : 15 (C) 2 : 15 : 15 (D) 4 : 15 : 15 (E) 6 : 15 : 15 ] Fig. 3 The calibration curves of different ratios of Meldola’s Blue to carbon powders and carbon paste ; [Meldola’s Blue : carbon powders : carbon paste = [ (A) 0 : 15 : 15 (B) 1 : 15 : 15 (C) 2 : 15 : 15 (D) 4 : 15 : 15 (E) 6 : 15 : 15 ] Fig. 5 The TB graphs of carbon paste electrode for determining the linear range of H 2 O 2 [Meldola’s Blue : carbon powders : carbon paste = 2 : 15 : 15 ( weight ratio )] CONCLUSIONS The results showed that the responding current for the carbon paste electrode modified with Meldola’s Blue was elevated significantly. The TB (Time Base ) graphs at different ratios of Meldola’s Blue to carbon powders and carbon paste were plotted to evaluate the effect of the ratio of Meldola’s Blue to carbon powders and carbon paste on the responding current of detection of hydrogen peroxide and determine the optimum operating conditions. The results showed that at the optimum operating conditions –300mV operating potential, 500rpm stirring rate and in 0.05M phosphate buffer solution(pH=7.4) [Meldola’s Blue : carbon powders : carbon paste = 2 : 15 : 15 ( weight ratio )], the detection limit was 0.02 mM H 2 O 2, the linear range was 0.02~1.4 mM H 2 O 2, R 2 =0.9994, and the sensitivity was μA/cm 2 ּmM H 2 O 2. REFERENCES 1.Kulys, J., Biosensors and Bioelectronics, 1999, 14, Mao, L. ; Yamamoto, K., Talanta, 2000, 51, Singh, S. ; Chaubey, A. ; Malhotra, B. D., Analytica Chimica Acta, 2004, 502, Liu, Y. ; Lei, J. ; Ju, H., Talanta, 2008, 74, Lai, G.-S. ; Zhang, H.-L. ; Han, D.-Y., Sensors and Actuators B, 2008, 129, Fig. 4 The TB graphs of carbon paste electrode electrodes for determining the detection limit of H 2 O 2 [Meldola’s Blue : carbon powders : carbon paste = 2 : 15 : 15 ( weight ratio )]