ProStar 335 Detector Wednesday, 26 April 2017

Slides:



Advertisements
Similar presentations
Single-use Quantasep Systems First Bench-top Single-Use flow- path Chrom System with gradient capability.
Advertisements

D e t e c t o r s f o r H P L C.
Nanodrop 2000c. Who is NanoDrop? Manufacture and Cell analytical laboratory equipment worldwide Used in biotechnology, pharmaceutical, and life science.
Compact & Perfect for Your Satisfaction
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
7. Beer’s Law and It’s Implications for Instrument Construction.
Project O.N.O.S.E. Optical Noxious Odor Sensing Electronics Capstone Preliminary Design Review Fall 2003.
What is Spectroscopy? The study of molecular structure and dynamics through the absorption, emission and scattering of light.
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
K-Space Associates, Inc. kSA BandiT: Band-edge Thermometry.
Fundamental Techniques and Measurements  Mass Measurements  Volume Measurements  Preparation of a solution of known concentration  UV-Visible Spectrophotometer.
LGS Project Meeting February 1, 2006 Agenda 1.IPT status updates: Laser facility, AO optomechanics, AO software (Bouchez, Roberts, Trinh; 30 min) 2.Sum-Frequency.
Atomic Absorption Spectroscopy (AAS)
NGAO NGS WFS design review Caltech Optical Observatories 31 st March 2010.
AccuMax Multi-Point Injection Mechanics
Spectrum 50 & 100 FIC Systems Up to 64 Dispense Points Up to 64 Dispense Points 1 to 4 Fluids 1 to 4 Fluids Printed Dispense Records Printed Dispense Records.
Introduction Purpose To introduce and familiarize Susumu thin film chip resistors Objectives Basic difference between thin film and thick film resistors.
Stand-Alone and Mesh Networks of Dissolved Oxygen (DO) Monitors Sd-May11-20 Betty Nguyen Scott Mertz David Hansen Ashley Polkinghorn Advisors Joseph Shinar.
Iris Range : «Unconventional» conventional detectors.
Characterization of CF 4 primary scintillation Andrey Morozov.
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
Introduction to the HPLC ChemStation and Acquisition.
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Enea Detectors Range.
High Sensitivity Smoke Detection
Exploring Boyle’s Law using Vernier Equipment
ProStar 210/218 Solvent Delivery Modules
ProStar 325 Detector Petro van Poppel – Field Support Specialist Friday, 9 October 2015.
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
900-LC P. van Poppel – Field Support Specialist October 2009.
VARIAN, INC. HPLC Products
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
Dilution and Spectroscopy Lab Lab Word Document Lab Word Document.
Comparison of Competitor
HPLC Installation Petro van Poppel – Field Support SpecialistMarch 2010.
ProStar 500 CVM P. van Poppel – Field Support Specialist October 2009.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
Diagnostics – Detectors Analytical 920 LCSemi-Prep 940 LC.
Overview of MSWS Control of 212-LC July 15, 2006.
Introduction to training
False asymmetries/Ground Loops David Bowman 4/27/12.
440-LC Fraction Collector
Waters HPLC Competitive Review
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Mechanical Components and Programming Ken Youssefi Introduction to Engineering – E10 1.
Temperature Back to Basics RTDs (Resistance Temperature Detectors)
A. Checks to run to make sure the instrument is in good working condition: Absorbance optics: ● run an intensity wavelength scan on an empty hole at 5.9.
Product and Application Overview
LIQUID CHROMATOGRAPHY
LIQUID CHROMATOGRAPHY
Fundamental Techniques and Measurements
Varian 940-LC Analytical to Prep HPLC
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Agilent 1100 Series System Operating principles
UCSB Short-term Testing Plan
UCSB Short-term Testing Plan
Running the BioLogic DuoFlow Starter Kit
Fundamental Techniques and Measurements
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Exploring Boyle’s Law using Vernier Equipment
High Accuracy UV-VIS Spectroradiometer ( nm)
Introduction to the NGC Chromatographic System
SAVI SCOUT® System Setup
Injector Drive Laser Technical Status
Presentation transcript:

ProStar 335 Detector Wednesday, 26 April 2017 Petro van Poppel – Field Support Specialist Wednesday, 26 April 2017

Overview Production Tests with 0x0 flow cell Introduction to PS 335 Detector Dual Array option Poly Verify Software Flow cell Communications Poly Verify Production Tests with 0x0 flow cell Wavescan (Settings Tab) (Input/Output Tab) (EEPROM) (COMMS Tab) (Calibration Tab) PS 335 Shipping Test Problems

ProStar 335 Mechanical Optical layout

ProStar 335 Ray Trace Layout

335 Optics

335 Ray Trace

335 Single and Dual Array Single Array 1024 photodiode sample array 2 photodiode references (250nm and 500 nm) No extended range spectra Uses only 9x0 and 4x0 flow cells Microbore to Analytical applications Dual Array 1024 photodiode sample and reference array Extended range spectra (up to 70-100 AU) Used for analytical to prep apps

Flow Cell Ray Beam General design of the 9x0 flow cell

Flow Cell Specs Flow Cell Prep (9 x 1) Super Prep (4 x 0.15) Analytical (9 x 0) Micro (4 x 0 ) Pressure rating 1000 psi Flow Cell Volume 30 µl 145 µl 15 µl 1.5 µl Material (non optical) Ti & PEEK Noise Performance 200 ml/min 10-500ml 1x10-4AU 800 ml/min 0.80-10 L 40 ml/min 0.1 µl-100 ml 5x10-3AU 1 ml/min 0-20 ml 7.5x10-3AU

Communications TCP/IP communications for Detector: Static or Dynamic Networked or standalone Firewall Access on Network, OS or PC

PS 335 PolyVerify Software

PS 335 PolyDiagnostics Ctrl-Shift-F10 to enable Diagnostics side Ctrl-Shift-F9 to hide Diagnostics side

335 PolyVerify Test Certificate Test Certificate provided by the factory for each 335 detector

PS 335 PolyVerify Tests

PS 335 Noise Test

PS 335 Wavelength Accuracy test Run with a 4 nm slit

PS 335 SBW Accuracy Test Wavelength Range of 190 to 950 nm

PS 335 Detector Linearity Test pump head pressure of at least 100 atm using a back pressure restrictor of 40psi .

PS 335 Wavescan

PS 335 Wavescan Results This wavescan seems to have a rather large difference between the sample and reference paths (long and short paths). Possible reasons for this are bad calibration, dirty flow cell, air bubbles in flow cell, foggy optics.

PS 335 Contributions from each Lamp

PS 335 PolyDiagnostics Mode

PS 335 Input/Output Mode

PS 335 Main PWB Power Supply LED’s C A: + 24 V power Supply B: + 9V and – 9V Power Supply C: + 5 V Power Supply Front of the Unit

PS 335 Identifying the Array Type Knowing the Array type is necessary when running the Input/Output test diagnostics

PS 335 Dual Array P8 disconnect P8 connection

PS 335 PolyDiagnostics EEPROM

PS 335 PolyDiagnostics COMMS

PS 335 PolyDiagnostics Calibration Tab

Caffeine Shipping Test PS 335 Caffeine Shipping Test: Test made up of 1 components: Loop injection using 25 µg/ml caffeine Test is conducted using Galaxie Software

PS 325/335 Caffeine Loop Injection Test Test Calculates: Peak Height Peak Area Noise S/N

Common Problems PS 335 Error Messages Table can be found: High Noise Lamp on, not ready SIG_CC_SLIT_PEAK_NOT_FOUND SIG_CC_SIGNAL_OVERRANGE_REPREFORM_ LAMP_CAL COM_CC_CIRCULAR_BUFFER_OVERRUN _OCCURED 9555 LMP_CC_D2_FILAMENT_FAILURE Foggy Optics PS 335 Error Messages Table can be found: PS 335 Service Manual Dealernet

Foggy Optics What is Foggy Optics?

What is Foggy Optics? Three types of Foggy optics White powdery coating Rust/brown spot burn Speckled mirror (delamination)

What is Foggy Optics? Diagnosing Foggy Optics

Diagnosing Foggy Optics Run a “wavescan” test, When bad Open the optics and inspect.

Wavescan test results Intensity for the 254 nm line Currently is 10 – 50 K counts

False positive New D2 vs Aged D2 Intensities

What is Foggy Optics? Diagnosing Foggy Optics Treating Foggy optics

0603 Project (Foggy Optics) Proposed Fixes and their status: White powder fogging: due to leaky flow cells and customer sample depositing on the mirrors New Flow cells & fittings available for all cells except 4 x 0.15 Brown powder fogging: due to UV attack on some of the foam parts close to the UV source. Eliminating as much of the foam as possible and shielding the rest. Mirror delamination: due to UV attack on the thin Al coating of the mirrors Eliminated by putting a NiCr coating on the mirrors to strengthen the Al coating.

Opening and cleaning the optics

Cleaning 325 optics Clean area in circle Do not adjust!!

Wavelength calibration data must be entered into the 335 EEPROM Replacing Optics Wavelength calibration data must be entered into the 335 EEPROM

Replacing Optics This label is attached to the top of each optics module, the shipping box and the test document

Summary Single and Dual Array Optical path is open Flow cell is dual path Diagnostics Tests, like wavescan Shipping Test Main Problems (Foggy Optics)