Mount structure concept FM1 & FM2 Mount structure design 1) Aluminum structure. 2) Structure design for holding Newport mirror mount because of its compact.

Slides:



Advertisements
Similar presentations
Mock-Up Test For Optical Diagnostics MERIT VRVS Meeting April 12 th, 2006 By Thomas Tsang (BNL), Hee Jin Park (SUNY at Stony Brook) Thanks to Bill Sands.
Advertisements

LWIR FPA Mirror Image Problem & Recovery April 11, 2011 Roy W. Esplin Dave McLain.
Click on this image to open the full PDF document.
FourStar Image Motion Stephen Smee (410)
CMS ZDC Crane Emergency Payload Removal Procedures This document proposes the viability of using a portable hydraulic actuator Hand crane (Davit crane)
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
1 Grating Mount Requirements Weight:< 75 Lbs including grating (43.1 Lbs) Size:Fit within structural envelope. 1.5” for cell behind grating. Alignment:Adjust.
FDR Station 3 lift fixture, laser screens and brackets T. Brown and L. Morris with analysis support from A. Brooks December 3, 2007.
, CLIC Test Module Meeting Status of the DB Quad adjustable support design Mateusz Sosin CLIC Module WG Meeting, 22-May-2013.
1 Effect of missing/loose screws 03/01/04. 2 Moment Load about E-W Axis-1 S N 20 lbs +/-5% Result of 20 lbs load:.005 inch flexure at point of application.
1 Acquisition Camera: Troubleshooting Help Vern STAHLBERGER Institute for Astronomy August Comments and Purpose: 1)Images not centered in Acquisition.
PALM-3000 Optical Bench Update Jenny Roberts Optical Bench Team: C. Baranec, A. Bouchez, K. Bui, R. Burruss Team Meeting #15 10/29/2009.
1 Acquisition Camera: Task-List to check Flexure Date first created: 02/05/04 Date last modified:02/06/04.
Senior Design: Validation of Design December 15, 2008.
PALM-3000 HOWFS - 7/24/09 C. Baranec. PALM-3000 Current Status Summary 2 Telescope simulator assembled HOWFS assembled and tested Alignment plan (CIN.
1 RF-Structures Mock-Up FEA Assembly Tooling V. Soldatov, F. Rossi, R. Raatikainen
18/13/2015Alex Delacroix NGAO Laser Guide Star Mechanical PDR.
Oct 17, 2001SALT PFIS PDR - Structure1 Structure Interface/ constraints Loads Structure design rationale Truss Weight and CG Finite Element Analysis/ Image.
Automated HIC assembly A. Di Mauro ITS-MFT mini-week
ISHELL Design Review Cryostat & Optics Bench Dan Kokubun 9/11/2013.
P14542: Vertical XY Camera Rig Subsystems Design Review Oct
SAM PDR1 SAM LGS Mechanical Design A. Montane, A. Tokovinin, H. Ochoa SAM LGS Preliminary Design Review September 2007, La Serena.
ZDC/Dummy Absorber Exchange Crane Proposal Paul Debbins Ianos Schmidt Univ. of Iowa - Nov. 5, 2007.
MCAO Adaptive Optics Module Mechanical Design Eric James.
Determinate Space Frame Telescope Structures for SNAP Bruce C. Bigelow University of Michigan Department of Physics 7/28/04.
Thomas Jefferson National Accelerator Facility Page 1 IPR October Independent Project Review of 12 GeV Upgrade Jefferson Lab October 18-20,
Update on alignment kit and stave 250 frame M.Gibson (RAL) 1.
PACS IIDR 01/02 Mar 2001 FPFPU Alignment1 D. Kampf KAYSER-THREDE.
MARS 2 Design Review-Optomechanical Review 07 Nov 2002 GLW1 MARS 2 Mechanical Design Review.
MERLIN BEAMLINE RIXS refocusing mirror system D. Yegian
CLASSE prototype: mechanical concepts G. De Michele, EPFL-PSI-CERN on behalf of CERN team SLAC, 16 th April, 2012.
LARP LHC PHASE II COLL RC1 TESTS - S. Lundgren 06 June 2006 No 1 /17 LARP Phase II Secondary Collimator RC1 Collimator Test Program Plan Forward Revised.
STATUS of the final PACMAN bench integration PACMAN meeting 11/06/2015 Hélène Mainaud Durand.
Laboratory Tips and Microscope Use. Setting Up: Microscope Carrying and Bench Layout Always hold the arm of the microscope while supporting the base with.
ZDC Remote Handling Tool Structure and Force Analysis P. Debbins University of Iowa December 10, 2009.
Oct 17, 2001SALT PFIS Preliminary Design Review1 Southern African Large Telescope Prime Focus Imaging Spectrograph Mechanical Mechanism Design Michael.
1 MC Assembly over the VV FPA Station 3 FDR Review July 13, 2007 T. Brown.
Exit slit toroid, with horizontal steering servo-loop to slits monochromator, with mirror and grating scanning Beamline Mono residual steering effects.
Systems Level Demo P15010: Arc Wheelchair Swing. Maggie Bates BS/ME Industrial & Systems Engineering Owen Breese BS Mechanical Engineering Elizabeth Cutolo.
Team INASAD Members: Jose Medina Joseph Leone Andrew Merk Alex Sanders Michael Fox.
VEA’s proposal of automated assembly system WP6 meeting, 16/01/14.
LIGO-G D Design Requirements Larry Jones Advanced LIGO, Seismic Isolation System (SEI) Structural Design & Fabrication Bidder’s Conference April.
Cloudland Instruments Hawkeye Mechanical Design Snapshot Compiled April 8th, 2016.
Ladder Mount R&D T. Tsuboyama (KEK) 2 Oct T. Tsuboyama (KEK) 2 Oct
1 VV Support Fixture FPA Stage 1 PDR Review August 10, 2005 T. Brown.
Camera Motion System Requirement Design Details FEA.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Four OTRs for ATF2 OTR History Current OTR setup New OTR design.
K.Long/G.Barber Mice Tracker Mechanical Status CM20 Feb 08 1 Mice Tracker Mechanical Status Contents:- Tracker 1 Status Tracker 2 Status Further Hardware.
Integral Field Spectrograph Opto-mechanical concepts PIERRE KARST, JEAN-LUC GIMENEZ CPPM(CNRS),FRANCE.
F/8 tip-tilt mechanism and handling cart P. Schurter December 2012.
TPC Support Installation 26 Apr 2016Dan Wenman Mechanical Engineer1 Overview Installation of the support rails Details of the rail from the SAS to the.
Mars Sextant PDR Opti 523 Paul Ward-Dolkas.
Annex 5 - Tower and Lock installation
HLTS Kickoff Presentation Derek Bridges Bobby Moore July 7, 2011
Mechanical Design Review February 25, 2008 Université de Montréal
LARP Phase II Secondary Collimator RC1, ETC - Status 4/10/06
From: Microtube Laser Forming for Precision Component Alignment
LARP Phase II Secondary Collimator RC1
IR Detector - Test cryostat : Machining
Hawkeye Mechanical Design Snapshot
Equilibrate System upgrade
iSHELL Design Review Cryostat & Optics Bench
Adjusting Tilt and Turn Inswing Door or Window
Additional Upstream Coil Shielding
Please see slide 2 for the caption of this figure.
Additional Upstream Coil Shielding
Gattini Detector Installation
450DA 4”-10”.
Goodman Acquisition Camera
Presentation transcript:

Mount structure concept FM1 & FM2 Mount structure design 1) Aluminum structure. 2) Structure design for holding Newport mirror mount because of its compact. 3) FM1 assy can be manually adjusted in vertical direction. 4) FM2 assay can be adjusted in horizontal direction. July KHANH Newport mirror mounts with 6” mirror )versized base plate for ease of clamp On the bench FM1 FM2

FM1 & FM2 Mount structure design Displacement analysis The displacement of the structure is greatest when it is in horizontal position as shown. The flexure analysis is only focus on the FM1 mounting shaft, which has the greater distance from the base. Empty structure weight : 10.5 lbs Each mirror mount assy weight : 8 lbs max. (assy includes mirror, Newport mount, mount bracket and shaft) - Structure constrain at the base (no translation) - Entire structure (includes FM1 & FM2 assy) under gravity. Displacement result: FM1 mounting shaft displacement relative to the fixed base :.009 mm (linear) (rotation) = 5.4arc sec With the allowable flexure of 10arc sec,the structure‘s stiffness is acceptable. FM1 mounting shaft FM2 mounting shaft

Mirror holder modification Newport P/N 625-RC6 1) Component replacement : T increase the stiffness of the mirror mount, The compression Spring must be replaced with higher spring rate. - Existing spring rate : 9 lbs/in - New spring rate 17.7 lbs/in 2) Structure modification Spring plunger with nylon ball tip 1.5 to 3 lbs load Retainer in mirror holding position Retainer in position for mirror release Area represents the required Aperture of 116mm in diameter 3 Retainer are mounted on the shell of Newport mirror mount, which can rotate around the screw to clamp or Release the mirror. These retainers are totally clear of an required aperture.

FM3 Mount structure design 8” Mirror mount Photosigma # Because of space constrain.some Conditions must be met: - Compact design of the mirror mount adaptor assy. -Vertacal orientation of the mirror mount. -

FM3 Mount flexure Gravity in Z-dir Gravity in X-dir Z X Y

FM3 Mount flexure flexure in Y-dir Flexure in X-dir Flexure in Z-dir Gravity in X-dirGravity in Z-dir Mount structure weight : 9.4 lbs Optosigma mirror mount weight : 4.9 lbs 8” mirror estimate weight : 4 lbs Unit in [arc sec]

HOWFS/ACam Partial HOWF assy is shown

HOWFS/ACam Adaptor plate Collimating mirror mount #2 Lens mount (CO1) Focus camera assy (shown with dark cover ) By using adaptor plate,the entire optical assembly can be installed or removed from the stage without disturbing an optical alignment.

HOWFS/ACam Main dark cover Snap-in rubber profile for light seal Dark cover structure

HOWFS/ACam Dark cover Camera assy Pins installed to ensure the repeatability of the camera assy Focus camera assy lay-out Array lens #1 CCD50 Adjustment knobs will be replaced With low profile hardware

HOWFS/ACam Flexure of the optical components of the focus camera assy Z X Y Camera weight = 3 lbs Array lens assy : 1 lb max Gravity in Z-dir Gravity in Y-dir GravityRotationArray lens #1CCD05UTS50CC Max. allowable flexure/hr From FEAMax. allowable flexure From FEA Max. shift Z-dir90° 0.1 arcsec =3.6 µm.78 µm 0.1 arcsec =1.2 µm.58 µm.05 arcsec. 15°/hr.005 arcsec.012 arcsec Y-dir90°1.2 µm.33 µm 15°/hr.008 arcsec.007 arcsec

HOWFS/ACam Flexure of the main optic mount struture Z Y X Boundaries: Loads apllied to the maun structure as follow : *1 : Focus camera assy = 15 lbs *2 : Lenslet assy with stages = 4 lbs *3 : Acam. Lens mount assy with stage = 4 lbs *4 : Field lens mount assy = 1 lb *5 : Acam M2 assy = 1 lb *1 *2*3 *4 *5

Flexure of the main optic mount struture Deflection of the focus camera assy in Y-dir under gravity Max. allowable flexure 1.2 µm = 0.1 arc sec/hr From FEA : 0.27 µm =.022 arcsec /hr

HOWFS/ACam GravityRotationCO1Mirror #1Field stop Max. allowable flexure/hr From FEAMax. allowable flexure From FEA Max. allowable flexure From FEA Z-dir90° 0.1 arcsec =3.6 µm.17 µm 0.1 arcsec =39 µm.075 µm 0.1 arcsec=39 µm.18 µm 15°/hr.0012 arcsec arcsec.0001 arcsec Y-dir90°048 µm.08 µm 0.1 arcsec=39 µm 1 arcsec arcsec arcsec 15°/hr.0006 arcsec GravityRotation CCD05Array lens #1CO1Mirror #1Field stopTotal flexure From FEA Z-dir15°/hr 012 aarcsec.005 arcsec.0012 arcse arcsec arcsec arcsec Y-dir15°/hr 007 aarcsec.008 arcsec arcse arcsec arcsec 0164 arcsec Total flexure of Optic mount struture Total flexure of MPA-CC stage Total flexure of UTS50 stage Total flexure of ATS150 stage +++ (Z-dir).0184 arcsec (Y-dir).0164 arcsec.012 arcsec.05 arcsec ? ≤ 0.1 arcsec/hr

HOWFS/ACam Field stop assy using existing components Cut for clearance Adjustment direction

HOWFS/ACam Field stop assy usung XYZ stage Direction of adjustment of mirror Direction of adjustment Of mirror Newport XYZ stage Work progress: - All fabrication parts are released. - Assy drawing completed and checked into the vault - Need stage #461-XYZ-LH-M and actuator #AJS ARE ON ORDER

HOWFS/ACam Field stop assy usung XYZ stage Field stop assy

HOWFS/ACam Main dark cover design and installation Main dark cover with Captive hardware Baffle tube (part of the dark cover) To prevent the dark cover from striking the fold mirror assy during an installation of the cover,two long posts are mounted in place as shown for the cover to slide Down. The dark cover will be engaged with the posts first before sliding past the fold mirror assy. Sliding posts

HOWFS/ACam Top view of the optical bench

DM 3368 Design concept DM holding frame assy Weight :8.6 lbs Frame shown with DM assy in place

DM 3368 X Y X Displacement at the center of DM3368 [mm] DM 3368 tilted thru gravity [arcsec] Gravity in X dirGravity in Y dirTilt in Y dir of gravity only 2.28 e e Block to represent the DM3368 assy for analysis (weight approx. 21 lbs) Flexure analysis