Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.

Slides:



Advertisements
Similar presentations
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Advertisements

Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Calibration for LHAASO_WFCTA Yong Zhang, LL Ma on behalf of the LHAASO collaboration 32 nd International Cosmic Ray Conference, Beijing 2011.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Figure 5. Histogram of the decay constant. Black curves: raw histograms; Blue curve: Gaussian fit to the histogram from the 20GS/s waveform; Red curve:
Observation of Fast Scintillation of Cryogenic PbI 2 with VLPCs William W. Moses, 1* W.- Seng Choong, 1 Stephen E. Derenzo, 1 Alan D. Bross, 2 Robert Dysert,
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
June/5/20081 Electronics development for fast-timing PET detectors: The multi-threshold discriminator Time of Flight PET system Contents 1. Introduction.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Photon detection Visible or near-visible wavelengths
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
MPPC R&D status Kobe Univ. CALICE collaboration meeting Yuji SUDO Univ. of Tsukuba ~ contents ~ Introduction Linearity curve Recovery time.
1 Performance of multi-anode PMT employing an ultra bi-alkali photo-cathode and rugged dynodes Takahiro Toizumi Tokyo Institute of Technology S. Inagwa.
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
Status of scintillator KLM study P. Pakhlov (ITEP)
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
Uni Bergen:G. Eigen, J. Zalieckas, E. van der Kraaij FZU Prague: J. Cvach, J. Kvasnicka, I. Polák CALICE meeting, Argonne, 19/03/2014.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
A novel gamma-ray detector with sub-millimeter resolutions using a monolithic MPPC array with pixelized Ce:LYSO and Ce:GGAG scintillators Takuya Kato J.Kataoka,
Uni Bergen:G. Eigen, E. van der Kraaij, J. Zalieckas FZU Prague: J. Cvach, J. Kvasnička, I. Polák Linear Collider Workshop, Tokyo 13/11/2013.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
MEG II 実験 液体キセノンガンマ線検出器に用いる 光検出器 MPPC の 実装に向けた最終試験 家城 佳 他 MEG II collaboration + 九大の方々.
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
Proposal to Test Improved Radiation Tolerant Silicon Photomultipliers F. Barbosa, J. McKisson, J. McKisson, Y. Qiang, E. Smith, D. Weisenberger, C. Zorn.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Performance of SiPM Ryuhei Nakamura (Kobe Univ.) GLC calorimeter group (KEK, Kobe, Konan, Niigata, Shinshu, Tsukuba) Contents ・ Introduction ・ Test results.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
Gain stability and the LYSO beam radiation monitor measurements
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
Fumihiko Ukegawa University of Tsukuba, Japan 6th Joint Korea-Japan ScEcal Meeting September 3, 2010 Kobe University Photo-sensor studies.
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
Potential Advantages of Digitally Sampling Scintillation Pulses in Time Determination in PET Q. Xie 1,2, C.-M. Kao 1, X. Wang 2, N. Guo 2, C. Zhu 2, H.
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
M.Teshima (MPP, U-Tokyo) M.Pimenta (LIP) T.Schweizer (MPP)
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
SiPM Readout ASIC LAPP Contribution JM Dubois, N. Fouque, R. Hermel, G. Lamanna, F. Mehrez, J.L. Panazol, J. Prast, S. Rosier.
SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Study of scintillator detectors time resolution with different SiPM readout on T10 test beam.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Development of Multi-Pixel Photon Counters (1)
The dynamic range extension system for the LHAASO-WCDA experiment
Activities at SMI/Vienna in testing the performance of SiPMs
Fabio, Francesco, Francesco and Nicola INFN and University Bari
FINAL YEAR PROJECT 4SSCZ
Fast SiPM readout for PET
Development of a High Precision Axial 3-D PET for Brain Imaging
SiPM Readout ASIC LAPP Contribution
Department of Physics and Astronomy,
The New Readout Electronics for the SLAC Focusing DIRC Prototype (SLAC experiment T-492 ) L. L. Ruckman, G. S. Varner Instrumentation Development Laboratory.
X. Zhu1, 3, Z. Deng1, 3, A. Lan2, X. Sun2, Y. Liu1, 3, Y. Shao2
3x3-MPPC-SMDx16ch SiPM tileable modules from Hamamatsu
A Multi-Threshold Method for TOF-PET Signal Processing
Latest Results from T979: PSec Time-of-flight
MCP PET Simulation (7) – Pixelated X-tal
Test Setup SiPM Hamamatsu S C Pixel size( 25um)
Presentation transcript:

Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of Radiology University of Chicago Topics: Applications and Goals Experimental Setup MPPC Single pe observation at room temperature with 1.2 μs effective gate Initial Time Resolution Studies 137 Cs Source spectrum for MPPC (time permitting)

2 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Applications and Goals Improved small animal PET scanner –Finer spatial resolution using MPPC array on crystal(s) LYSO, LSO, BGO Combination with differing decay characteristics to determine depth of 1 st interaction –Good time resolution (< 50ps) of 511 keV γs to provide real time imaging (10 ps resolution ≡ 3mm) Fine-grained camera for Imaging Atmospheric Cherenkov Gamma-Ray Telescope (AGIS collab in U.S.) –Optical design reduces aberrations by adding curvature to the camera “plane”. (UCLA collaborators) –Small feature size photodetectors required Prototype Support Structure Design for a Two Mirror Aplanatic Telescope Victor Guarino, Argonne Natl. Lab.

3 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Experimental Setups Timing Resolution MEPhI and CPTA SiPM Test Board 408nm Diode Laser 75ps pulse width Bias voltage & output to CFD/ADC Neutral Density Filters Single pe, Linearity, Source Spectra Blue (468nm peak) LED and exponentially-graded filter wheel R580 reference PMT 50μm Pixel MPPC 1x1x10mm 2 LYSO Single pe and Linearity measurements made with correlated double sample-and-hold (Fermilab CDF RABBIT System). 1.2μs effective gate. Timing measurements use output from Ortec 9307 CFD → 25ps/count Phillips 9186 TDC

4 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University MPPC Individual Photoelectron Observation MPPC Sample 53 operating V = 70.23V Noise at operating voltage at room temperature is quite low!! Gate of 1.2μs substantially longer than most other studies Fit has no background! Just sum of 6 Gaussians (pedestal pe). 1x1mm 2 effective area 50μm pixel size 400 total pixels

5 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Comparison to Single pe Detection in MEPhI SiPM Cooled to ~ -15°C using dry ice Same at room temperature Both measurements using correlated double sampled readout with Before/After effective gate width 1.2μs

6 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Initial Timing Resolution Results (1) – MPPCs Time resolution at highest light levels. Substantial saturation of MPPC Time Pulse Height Attenuation of laser pulse to few pe level. Individual pe evident No deconvolution of contribution from laser, CFD, and TDC has been done.

7 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Initial Timing Resolution Results (2) – MEPhI E404  Gain ~ 4 x 10 5

8 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Energy Spectra from LYSO Background ( 176 Lu) & 137 Cs Hamamatsu 25μm pixel MPPC at V = 78.94V MEPhI Sample operated at V = 43.0V Background decays of 176 Lu in 1x1x10mm 3 crystal 200ns

9 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Energy Spectra from LYSO Background ( 176 Lu) & 137 Cs σ/E ~ 9.2% (22% FWHM) Expanded scale from those on left. Rough absolute zero approximated. Background spectrum from 176 Lu decays? Uncalibrated horizontal scales

10 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Future Plans Building several 4x4 MPPC arrays close-packed. We are upgrading the timing DAQ in laser test stand with TAC/ADC capable of 10ps resolution. Three studies with arrays: –Install one test 4x4 array in Argonne/UC TrICE Cherenkov Telescope Use existing TrICE Front End Electronics for readout Determine MPPC sensitivity to Cherenkov light from imaged showers – Study position resolution with charge division with 3 MPPC linear array viewing LYSO crystal irradiated with 137 Cs and 22 Na –Place 4x4 array against LYSO & BGO crystals to study position resolution and depth of 1 st interaction

11 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Conclusions Initial studies indicate good timing resolution with both Hamamatsu MPPC and MEPhI SiPM detectors Hamamatsu MPPC has very good performance for low noise We are still very early in our studies but making good progress. We expect to learn much more in our work over next months with arrays plus work on individual devices both in timing and energy resolution.

12 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Backup Slides Follow

13 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Laser Timing Synch output from laser MPPC output from laser pulse

14 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University Saturation Measurement of Hamamatsu MPPC MPPC μm pixel size with 400 total pixels ADC counts corresponds to 34.3pC. For Gain = 5.65x10 5, implies about 380 pe. (or fired pixels at full gain)

15 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University 25μm Pixel Size I-V Curve

16 R. Wagner, MPPC/SiPM Timing Resolution PD07 Kobe University RABBIT Before/After Timing RABBIT Before/After timing with respect to signal from MEPhI SiPM Blue - Before Purple – After Yellow – SiPm signal using LED pulser