Plant Wide Alarm System Alarm Tones  4 Alarm Tones  General Evacuation – Wail  Severe Weather – Pulsed Steady  Local Alarm – Pulsed Wail  All.

Slides:



Advertisements
Similar presentations
Log In with RF LCD Clickers Channel 65. Log In with your Clicker This is what the clicker looks like Here are the steps: 1.Click on CH button 2.The light.
Advertisements

Home Automation Products Introduction Home Automation Products تقنية البيوت والمكاتب الذكية –الأجهزة المستخدمة.
How to use the NEC projector Its easy! Really!. How to use the NEC projector IMPORTANT-make sure you have reserved the equipment (projector and/or laptop).
AIM Armstrong’s Intelligent Monitoring Training presentation.
TAG Content Development MOTOROLA and the Stylized M Logo, and ASTRO are registered in the US Patent and Trademark Office. All other product or service.
1 Introduction USG-2602 Children's safety zone service Universal Security Group Israel ltd.
LogTag Training January 2015
Portable Radio Operations
To Begin, visit Updating the Software Step 1 Eclipse AVN726E / AVN76D.
How to Reprint a Registration Statement via Colleague Updated
May 2007 North Zone – Communications Motorola W9 Control Head North Zone Communications Committee.
Scott Electronic Management System
TORNADO WARNING SIGNAL Tornados and Severe Weather Fort Rucker Severe Weather Siren Warning System STEADY TONES ON THE POST SIREN SYSTEM TAKE IMMEDIATE.
XP Tutorial 4 New Perspectives on Microsoft Windows XP 1 Microsoft Windows XP Personalizing Your Windows Environment Tutorial 4.
ROTHENBUHLER ENGINEERING
The physical parts of Computer
PSS MERLIN TELEMETRY BOARD Quick Menu
MySOS User Guide.
PART-2. Access the functions as described. Accessing functions. To change the accessing password, follow the steps below. Use the NEXT key to select:
Yuma Regional Communications System
The Comfort System Product Presentation The Intelligent Home System.
Microsoft Windows Vista Chapter 6 Customizing Your Computer Using the Control Panel.
Network Printing. Printer sharing Saves money by only needing one printer Increases efficiency of managing resources.
TORNADO WARNING SIGNAL Tornados and Severe Weather Fort Rucker Severe Weather Siren Warning System STEADY TONES ON THE POST SIREN SYSTEM TAKE IMMEDIATE.
Troubleshooting Computers in the FHC. Hardware Issues Computer will not turn on – Check power cable – Check power strip Computer is on, but screen is.
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
MySOS Device User Training
North Zone – Communications
1 BRIDGEPAD (BP) SYSTEM TRAINING Adapted for ScoreBridge Users By John de Ridder PSBC Revised 2 November 2009.
The Comfort System Product Presentation The Intelligent Home System Revised May 2009.
The Headphones1 Trainer Training The Headphones. 2 There are three sets of headphones There are three transmitters Transmitters also act as battery chargers.
Systems technologies // healthcare solutions. What is messenger? Multi-user messaging platform Sends messages to: Wireless Telephones (WiFi / DECT) Pocket.
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
Speech Room AV Capture Station Speech Room AV Capture Station Revision Date: November 2014.
System introduction Sept What is Urgentys ? The Urgentys is a unique lone worker protection system centrally operated on a world-class platform.
The Computer The Survival Guide to Turning On, Logging On, Logging Off, and Shutting Down Your Computer.
Basic MAC Troubleshooting. Kernal Panic Error A kernel panic during startup can have many possible causes, including: Hardware Devices Corrupted file.
2007 TAX SEASONERO TRAINING - MODULE 31 ERO (Transmitter) Training Module 3 Transmitting and sending Training returns.
TRBOnet Indoor Components Beacon (Transmitter) Option Board with Antenna (Receiver) TRBOnet Software.
Floor Wardens Safety Monitors & Guests. Overview.
 Transportation puts in the student conduct report, describes the student, the incidents, and makes sure to assign the appropriate school THEN CLICKS.
1. 2 INDEX MAIN DISPLAYS3-4 SYSTEM LAYOUT 5-6 ROOM P-109 DISPLAY7 ROOM P-108 DISPLAY8 ROOM P-107 DISPLAY 9 ROOM P-106 DISPLAY 10 ROOM P-105 DISPLAY 11.
Display System for 6400/6300 Protec Alarm Control Systems. Series of Graphic Screens shows all Addressable Devices and their status indication Complicated.
2007 TAX YEARERO TRAINING - MODULE 41 ERO (Transmitter) Training Module 4 Acknowledgements.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Elluminate Live! Participant's Guide Ensure your computer meets the minimum system requirements recommended for running an Elluminate Live! session on.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Computer Lab Login and Trouble Shooting Weber School District 2002.
2015 Touch Screen Voting Device Training For AVPM and Non-AVPM TSX Counties Presented by: Derrick Cooper Elections Systems Training Specialist Mississippi.
1 Touch Screen Voting Device Training Election Systems & Software.
Touch Screen Voting Device Training Election Systems & Software Presented by: Bill Lowe.
When you open the slide show you will see the following dialog box asking do you want to activate the clicker session. Select YES. Starting the Clicker.
EGIS Man-Down - Quick User Guide Version
Louisiana State University Radiation Safety Office
Contents and Direct Links
XT Camera Firmware Update Process
Ping™ 6.
Fire or Emergency Procedures
Giant Voice (GV) Siren System At Hoc Desktop Alerting
1. Press the Power button or switch to flip on the printer, if it is turn off. 2. From the Home display screen on the product control panel, click the.
Installing the HP LaserJet Pro 500 color MFP M570 printer software in Windows on a Wireless Network & Wired Network.
Automatic Test Station for GasAlertClip Extreme Portable H2S Monitors
AIM Armstrong’s Intelligent Monitoring Training presentation.
Pubic Safety Radio System Paging System Operation Overview
SAGE Test Administration
Using the Dean’s Boardroom
Public Safety Radio System
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
Click “Execute” button.
Presentation transcript:

Plant Wide Alarm System

Alarm Tones  4 Alarm Tones  General Evacuation – Wail  Severe Weather – Pulsed Steady  Local Alarm – Pulsed Wail  All Clear - Steady  4 Alarm Tones  General Evacuation – Wail  Severe Weather – Pulsed Steady  Local Alarm – Pulsed Wail  All Clear - Steady

Alarm Locations Alarms are located in following locations:  Area 2 (Tag # S-M-301E)  Area 5 (Tag # S-M-301D)  Area 4 (Tag # S-M-301G)  Area 6 South (Tag # S-M-301C)  Dock (Tag # S-M-301H)  North Tank Farm (Tag # S-M-301F) Alarms are located in following locations:  Area 2 (Tag # S-M-301E)  Area 5 (Tag # S-M-301D)  Area 4 (Tag # S-M-301G)  Area 6 South (Tag # S-M-301C)  Dock (Tag # S-M-301H)  North Tank Farm (Tag # S-M-301F)

Area 2 Area 2 Area 5

Area 4 Area 6 South

Dock North Tank Farm

Discrete Alarms  Each alarm location is activated thru a radio frequency  MHz UHF  Alarm Locations are battery powered by Volt Batteries  Batteries are kept charged by solar panels at each location.  Each alarm location is activated thru a radio frequency  MHz UHF  Alarm Locations are battery powered by Volt Batteries  Batteries are kept charged by solar panels at each location.

Alarm Activation Alarm can be activated in 2 locations  Northeast Corner of Central Control Room (Tag # S-M-301A)  SS2000D Encoder, Microphone and Computer  Security Office Administration Building on St. Bernard Hwy. (Tag# S-M-301B)  SS200D Encoder and Microphone only Alarm can be activated in 2 locations  Northeast Corner of Central Control Room (Tag # S-M-301A)  SS2000D Encoder, Microphone and Computer  Security Office Administration Building on St. Bernard Hwy. (Tag# S-M-301B)  SS200D Encoder and Microphone only

Alarm Activation  When event has been identified  Appropriate alarm is activated by pressing the pre programmed key sequence on the SS2000D FSK Encoder or the computer in Central Control  Warning tones will sound for the pre- programmed period of 3 minutes or until cancelled.  The Microphone can be used for making emergency voice broadcasts  When event has been identified  Appropriate alarm is activated by pressing the pre programmed key sequence on the SS2000D FSK Encoder or the computer in Central Control  Warning tones will sound for the pre- programmed period of 3 minutes or until cancelled.  The Microphone can be used for making emergency voice broadcasts

Activating via the SS2000D

System Activation 2. Press the Function Button SYSTEM ACTIVATED 1. With Key in, turn Key switch to “ON” 3. Verify function selection 4. Press the “Send” Button

Canceling a Command or an Activation Before a Function has been sent, Press “CLEAR” to Cancel After a Function has been sent, Press “CLEAR” if polling is in progress then press “CANCEL ALL” and press “SEND” CANCEL ALL

SS2000D Alarms and Status Indicators  PRINTER – Indicates when the SS2000 sends information to the printer  CARRIER – RF Channel busy indicator  AUX. – Auxillary use only  KEY – Lights whenever a key on the mylar keypad is depressed  PRINTER – Indicates when the SS2000 sends information to the printer  CARRIER – RF Channel busy indicator  AUX. – Auxillary use only  KEY – Lights whenever a key on the mylar keypad is depressed PRINTER CARRIER AUX. KEY

Monitor and Activate via the Computer

Recommended View – Map Screen 1. Click “Map”2. Click “Legend”

Checking for Site Status Click desired Site Click Poll To get an updated Site status Click “Notepad” to create Notes

System Activation 1. Click “Activate”3. Click “OK”2. Click desired Hot Key SYSTEM ACTIVATED

Canceling a Command or an Activation Click “Cancel” before Entry has been sent. Click “Cancel All”, “OK,” after Command has been sent.

“Minimize” Acknowledging an Alarm Click AcknowledgeClick “System Log”

Never Exit the Program

System Monitoring  The PC at the base station in central control continuously monitors the system  The software keeps running log of all events and “Quiet Test” responses  Quiet Tests are performed automatically  Failure of Quiet Test will be indicated on the PC  The PC at the base station in central control continuously monitors the system  The software keeps running log of all events and “Quiet Test” responses  Quiet Tests are performed automatically  Failure of Quiet Test will be indicated on the PC