MDI Meeting 13 th MDI: Latest news on civil engineering and services First draft concept for the ventilation system in the CLIC experimental area 11/06/2010.

Slides:



Advertisements
Similar presentations
MODULE TRANSPORT CLIC Module Working Group 27 September 2010 Keith Kershaw CERN EN-HE.
Advertisements

Plasma Wakefield (AWAKE) Project Meeting 18 October 2012 Civil Engineering Feasibility Issues for the West Area EDMS : John Osborne GS-SE.
HSE Preliminary General Requirements for FCC layout and air management A. Henriques & M. Widorski on behalf of the HSE Unit 17/12/2014 FCC I&O Meeting.
Experimental hall in Japanese mountain site Y. Sugimoto ILD MDI/Integration 1.
First Considerations on CLIC Cooling System Ch. Martel, J. Inigo-Golfin TS/CV.
June 2004 Andrea Gaddi, PH-CMI USC Installation Commissioning Task Force 1st Run Meeting, June 3rd, 2004.
Construction and Installation of the CLIC Experimental Area
19/10/2010 GS-SEM J Osborne N Baddams A Kosmicki EN-CV M Nonis EN-MEF M Gastal PH-CMX A Gaddi H Gerwig A Herve N Siegrist DGS-SC.
Cryogenic cavern in Asian site Conceptual design of the cryogenic system Layout of the cryogenic plant for site A & B New layout of the cryogenic system.
Global Design Effort - CFS for Asian Single Tunnel Configuration Design Progress Masanobu Miyahara KEK.
CES Status J.Osborne 6 November 2009 Status Report from Civil Engineering and Services Working Group J.Osborne GS/SEM for CES Working Group.
1 Alternative assembly option of ILD Y.Sugimoto 2010/10/18 ILD Integration
TS Department / Civil Engineering Group 17 October 2007 Civil Engineering Layouts & Tunnel Cross Section 1 CLIC workshop – Working group: Two beam hardware.
1. Civil Engineering works for Linear Colliders* : -Brief introduction on the overall machine layout (just for CLIC at this stage) -Experimental Area.
WP2 Superbeam Work Breakdown Structure Version 2 Chris Densham (after Marco Zito version 1 )
CLIC CES Meeting 14 jan 2009 A resume table for fire safety in LHC, and a possible scheme for other machine – part 1 CERN –SC Fabio Corsanego.
ILC experimental area - How to ‘develop’ CFS details for TDP (cavern size, number of shafts, HVAC, EL spec etc) ? - KEK site specific issues CFS V.Kuchler.
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 28/7/2009 Already presented by C. Martel/ J Inigo Golfin on15 th October 2008 CLIC WORKSHOP.
Conventional Facilities and Siting 1 Alternate Site and Tunnel Configuration Status Report KEK (2) Nov. 2008, Chicago Global Design Effort Masami Tanaka.
Global Design Effort - CFS TILC09 and GDE AAP Review Meeting - Tsukuba, Japan 1 GDE ACCELERATOR ADVISORY PANEL REVIEW CONVENTIONAL FACILITIES.
1 CLIC / ILC Collaboration for CES issues JOHN OSBORNE – CES 8 April 2009.
Agenda : CLIC Civil Engineering and Services (CES) WG.
John Osborne : GS-SEM Civil Engineering 19 May 2009 Report on behalf of CLIC Civil Engineering and Services (CES) WG CTC 19 May 2009 Tunnel Cross Section.
10/2010 IWLC2010 Global Design Effort 1 Brief Overview of Interaction Region Conventional Facilities in RDR Times Presenter Tom Lackowski.
Civil Engineering and Services - drawings for CDR - CDR chapter J.Osborne and M.Gastal for CES WG 1.
A. Hervé - 17 Oct CLIC-Workshop CLIC Workshop: 17 Oct. 07 Interaction Region Engineering at ILC Push-Pull Option A. Hervé/CERN.
COOLING & VENTILATION FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 16/9/2009 CLIC TWO BEAM MODULES REVIEW
John Osborne : GS-SEM Civil Engineering 18 May 2009 CES 9 June News from ILC Japan CFS review 1-3 June 2010 :
Experimental Areas Studies Lessons learnt at CMS M Gastal & CMS Technical Coordination (A Ball, W Zeuner)
ILC D RAFT P ROJECT S CHEDULE K LYCLUSTER 500GeV K Foraz & M Gastal ILC Mechanical & Electrical Review and CFS Baseline Technical Review Many thanks to.
ICL 26/05/2010 Relocation of electronics at Pt5 Summary of week 22 + roadmap Contributions from GS-SEM, EN-MEF, EN-EL, EN-CV, BE-ASR, TE-MPE, PH-CMX, TE-EPC.
General Infrastructures Services Department Civil Engineering planning for LSS4 Option, presented at review workshop 30/7/ months Planning and Resources:
Contributions from BE -ABP -ASR -BI -CO DG -RP EN -CV -EL -MEF -STI GS -SEM -ASE IT -CSPH -CMXTE -CRG -EPC -MPE Follow.
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL CERN TS/CV Wednesday 9 th July 2008 CLIC.
Europe / CERN studies for SB2009 ILC Re-Baseling J.Osborne CERN (CFS & CES) 2009 Linear Collider Workshop of the Americas 28 September - 4 October 2009.
The integration of 420 m detectors into the LHC
CLIC MODULE TRANSPORT AND INSTALLATION Keith Kershaw CES, 8 October 2008.
MDI Meeting 13 th MDI: Latest news on civil engineering and services First draft concept for the ventilation system in the CLIC experimental area 11/06/2010.
1 st LTEX meeting Protecting the experimental caverns and personnel from a "sector 34 like" incident: work planned in the LHC tunnel Prepared by M GASTAL.
Experimental hall in Japanese mountain site 2011/11/30 Yasuhiro CFS Webex meeting 1.
Accelerator Tunnel Layout (G01) Nick Gazis Senior Mechanical Engineer Review of ESS Accelerator Conventional Facility Design.
SECONDARY BEAM HANDLING AND INFRASTRUCTURE DESIGN STATUS BRUNO FERAL (CERN/EN) DIAMANTO SMARGIANAKI (CERN/EN) Project Leader: I.Efthymiopoulos (Cern/EN)
COOLING & VENTILATION PLANTS M. Nonis – CERN EN Department / CV Group Annual Meeting of the FCC study – Rome 14 th April 2016.
August 2007Andrea Gaddi, CERN Physics Dept. Detectors Infrastructures & Services Baseline to design detectors infrastructures. Tentative arrangement of.
CV Activities for PSB-LIU POPS-B (new MPS for the PSB-LIU) B 245 PSB Demi water cooling plant Stefano Moccia, EN-CV Meeting 07/03/16.
1 Update of detector hall in mountain regions Y.Sugimoto in Granada.
Experimental Hall in Mountain Regions
FCC Underground Infrastructure
Civil Engineering for FCC-eh and LHeC
CLIC Handling Engineering Update
CLIC Civil Engineering Update
Yasuhiro Sugimoto 2012/2/1 ILD integration meeting
FCC Civil Engineering John Osborne, Jo Stanyard, Matt Stuart(SMB - Site Engineering - FAS Section) Cost & schedule Phase 3 - specification 10th May 2017.
CLIC Civil Engineering & Infrastructure
Experimental hall design in Japanese site
Tunnel Cross Section Studies
CLIC / ILC Collaboration for CFS works
Interaction Region Alternative Layouts
Part II: Integrated Design of Infrastructures
Radiation protection of Linac4 M. Silari Radiation Protection Group
Detector Service Cavern for ILC
FCC Tunnel and Shaft Cross Sections
Accelerator and Experiment Interface Session: LS2, LS3
Detector hall in mountain regions
A very first look at siting issues
COOLING & VENTILATION INFRASTRUCTURE
CLIC Civil Engineering Update
Detector hall in mountain regions
Extract from today’s talk given to DCB
RDR Baseline Layouts for Interaction Region
Presentation transcript:

MDI Meeting 13 th MDI: Latest news on civil engineering and services First draft concept for the ventilation system in the CLIC experimental area 11/06/2010 GS-SEM J Osborne N Baddams A Kosmicki EN-CV M Nonis EN-MEF M Gastal PH-CMX A Gaddi H Gerwig A Herve N Siegrist DGS-SC F Corsanego Contributions from

MDI Meeting Towards an integrated design: → Collect input from all actors → Detector community (H Gerwig, A Gaddi, A Herve et al) → Service groups (CV, EL, HE, ASE...) → Safety bodies (RP, SC...) → Modify Civil Engineering layout accordingly → Step 1: Basic requirements for detector → See Talk by A Gaddi presented at MDI on 23/04 → Step 2: Produce 1 st 2D CE drawings → See Talk by J Osborne presented at MDI on 07/05 → Step 3: Collect input from EN-CV on ventilation → See Talk by M Nonis presented at CES on 09/05 → Step 4: Present an updated CE layout and ventilation concept

MDI Meeting Machine By-Pass added To be moved away from cavern volume Survey gallery added Emergency escape tunnel First draft Experimental area layout as presented at CES 11/06/2010 No Alcoves

For CDR proposal of a cavern in a deep CERN type clay 7 May 2010H. Gerwig - 13th MDI4 Hall Experiment 1 Hall Experiment 2 Transfer tunnel with IP Alignment Tunnel Discussed with J. Osborne & M. Gastal Excavated volume is less than for a standard hall Flat walls on tunnel sides

MDI Meeting First draft concept for the ventilation system in the CLIC experimental area Warning: “The following ventilation concept is a first answer that needs to be confirmed and validated when details on geometry, thermal charges, fire safety and RP issues shall be communicated. At the present stage is not possible to size the installations, therefore major modifications can intervene” M Nonis

MDI Meeting FUNCTIONNALITIES ENSURED BY THE VENTILATION: Provide fresh air for personnel. Treat air according to need: heating, conditioning, dehumidify. Evacuate thermal charges. Ensure dynamic confinement between machine and accessible areas where 100% air tightness cannot be achieved Provide extraction capabilities Filtering exhaust air before releasing into the environment. Purge of areas (after fire).

MDI Meeting Assumption critical for the concept to be validated: → The airtight sealing of both experimental caverns should maintain a leak rate compatible with the establishment of a pressure differential with respect to the interaction region 11/06/2010 P USC55 – P UXC55 = 20Pa P Shelter – P USC55 = 20Pa P UXC55 – P S45 = 20Pa P UXC55 – P S56 = 20Pa Scheme at CMS

MDI Meeting First idea: Use of mobile shielding in conjunction with inflatable seal and expanding fire proofing sacks (TX54) 11/06/2010

MDI Meeting First idea: For CLIC moveable shielding walls, the cavern side of the opening to the transfer tunnel could be equipped similarly 11/06/ st layer of sacks Inflatable Seal 2 nd layer of sacks Transfer Tunnel

MDI Meeting The detector would be moved into beam position on a moving platform The concept could be similar to the PX56 plug (2200 tons) N Siegrist – PH-CMX

MDI Meeting

11/06/2010 Solutions to seal off a moving platform the size of the PX56 plug have been successfully implemented. → Area between the platform and the floor of the interaction region would have to be made airtight

MDI Meeting 11/06/2010 Since the services should not be disconnected, Cable chains will have to be used. Sealing off moving cable chains will be challenging Option to study: → Trenches could be closed in an airtight fashion using appropriate cover plates

MDI Meeting Ventilation sectors: The underground area shall be divided in the following sectors: → Cavern A → Cavern B → Bypass and interaction region → Emergency escape tunnel → Pressurised areas in shaft (2)

MDI Meeting Ventilation sectors: The underground area shall be divided in the following sectors: → Cavern A → Cavern B → Bypass and interaction region → Emergency escape tunnel → Pressurised areas in shaft (2)

MDI Meeting The standard ventilation scheme foreseen for the tunnel shall stop before the bypass junction. 11/06/2010

MDI Meeting Ventilation sectors: The underground area shall be divided in the following sectors: → Cavern A → Cavern B → Bypass and interaction region → Emergency escape tunnel (2) (changed at CES) → Pressurised area in shaft (2) Suggestion from DGS-SC: Each escape gallery should connect directly into a shaft shelter area

MDI Meeting For each sector it is foreseen: fresh air supply, extraction system, redundant AHUs located on surface, air recycling, ducts via existing shafts.

MDI Meeting Geometry of each area → Models by GS-SEM to be provided shortly Thermal charges: –equipment, personnel….. –their localisation –specific cooling needs in closed premises → 1st order number should be 125kW for each detector (A Gaddi) Radioprotection: –confirm air tightness between different sectors - caverns and interaction area (shielding, cable trays, drills etc.) –Confirm the need of an overpressure between areas (20 Pa) –Can we assume that the same air goes through the bypass and interaction region? –Can it be accepted that when the mobile shielding structures are open no ∆P can be maintained? Need for dedicated gas extraction in some areas? Need of secure network (UPS, diesel) Basic data to be provided in order to reach a more detailed proposal

20 Experimental Area Organization Power supply Slow dump resistor Breakers Cold box Fast dump resistor Dewar Flexible sc bus-bars Flexible transfer lines Services at end of Cable Chains Potentially closed A Gaddi

MDI Meeting In the past, it had been suggested to use the water from Lake Geneva mainly because cooling towers have a high environmental impact. Should this option be considered for the CDR, GS-SEM would suggest adding a new cavern. Shaft + Cavern would allow: 1.Space for machine equipment 2.Connection with water transfer tunnel 3.Take the bypass off the volume of the experimental cavern 4.Hosting of ventilation ducts for interaction region 5.Installation of heavy vibration equipment 6.Setup and removal of TBMs still being considered Point of attention → Equipment in new cavern should not introduce vibration in the EA Water transport tunnel Lake GVA 11/06/2010 To be confirmed

MDI Meeting CLIC WORKSHOP - Cooling Pumping station Cooling Production JIGolfin

MDI Meeting Summary → This very first concept of ventilation in the experimental area has led to consider modifications in the CE layout. More modifications are expected as constraints from other services groups are consolidated. → CE modifications to appear in next version of 2D drawings: → Bypass out of volume of experimental caverns → 2 Escape galleries connecting to the shaft shelters → Request for services from the detector community are educated guesses only → Designing the CLIC experimental area will pull together resources from different departments: Feedback on proposal welcome → In these areas detector, machine, infrastructure and construction issues are inter-related. → All stakeholders are encouraged to provide initial estimates of the characteristics of the equipment they plan to have running in the experimental area 11/06/2010

MDI Meeting Latest News → Feedback from accelerator community → Foresee an additional tunnel for 500GeV option to be used as delay loop → Necessity of a 3 rd shaft for the accelerator has to be assessed → Feedback from Detector community → A dew point regulation system should be foreseen – humidity control → T=20°C, Humidity [40%-60%] → Heat load in experimental hall = 125kW +/- 50% → Dynamic confinement might not be needed, more radiation protection studies needed → Purge system might not be needed → Gas extraction system has to be foreseen. Should be the same as for CMS → Pumping station has to be far enough from the IP as to not introduce vibration. Maybe, should they be installed at the extremity of the main linac. → Next steps: → Come up with a draft shaft cross section including lift, ventilation ducts, elements of detector, staircase, cable trays → Come up with a draft layout of surface assembly halls. One idea to investigate would be to have only one gantry crane