1 Chang Shuan Electronics Co., Ltd

Slides:



Advertisements
Similar presentations
MP200 Presentation MICRO-BIT TECHNOLOGY, INC..
Advertisements

MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
AC 650 the NEW 650 series ac inverters beauty in simplicity...
Supervisory Control & Data Acquisition DAQ Networking.
Arctic IEC-104 Gateway Jari Lahti, CTO.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
The New PAX Lite Meters. 2 © Red Lion Controls Inc. PAX Panel Meters PAX Lite Meters 16 Dedicated Meters Indication Only AC Powered Low Price PAX Meters.
1 Titre Tous droits réservés – Le contenu et les spécifications peuvent être modifiés sans avis préalable Digital process controller eNod3.
EUT 1040 Lecture 10: Programmable Logic Controllers.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Ahmed Abdel-Fattah Jerry Chang (a.k.a. Fred) Derrick Culver Matt Zenthoefer.
Aztec PC Scope Preliminary Design Review Fall 2006 Michael MasonJed Brown Andrew YoungsJosh Price.
Aloha Proof Module Design Cabled Observatory Presentation School of Ocean and Earth Science and Technology February 2006.
“We Weigh The World!” CAS Newton-500 Series CAS Marketing Team CAS Corporation.
DP Cabinet.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Temperature is more than just hot or cold - You are responsible for temperature - we give the tools.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
1 Sutron Corporation ModBusLink Plus sutron.com ModBusLink Plus.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
Let’s be Digital Introduction to NT-200 Series ( ) CAS.
Controller Wiring.
ESTeem Training Class ESTeem Overview. ESTeem Product Categories Licensed Serial – Long Range Application – Exclusive Use of FCC Frequency – PLC Emulation.
7526A Precision Temperature/Pressure Process Calibrator
Janus Convertible Line – interactive Series UPS
1 Chang Shuan Eletronics Co., Ltd
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
October 1, 2012 PAX2C Product Launch. 2 © Red Lion Controls Inc. PAX 2 C Universal PID Controller.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
SCAD 508 Strain Measurement System Click Here To Download Complete Information On SCAD Products EXCITATION VOLTAGESelectable from 0.5VDC to 10 VDC in steps.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
Modular Inverter.
Control Indicator R30 R30 Appearance
1 SPECIFICATION Power : DC 24V ± 5% Input Signal : RS – 485 SERIAL Display: 4 DIGIT LED (H:10.16mm) Address Selection : POWER TO INPUT Isolation: POWER.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
AGILENT 34401A MULTIMETER Produced by
Welcome to Product Workshop 2008!. The Indication Group Panel Meters Large Displays Sensors Temperature Controllers Signal Conditioners.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
CUE – Make Any Pump an E-Pump
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.
0 Configuring a 3500 Using iTools 2 iTools Workshop - getting started Start iTools and from the New File menu choose 3504 v1.04 programmer.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
WavePak DC/DC Isolator / Converter. Essential facts Scalable I/O ranges “Lite” version of Wave PRO DC/DC Selectable Active or Passive input 24Vdc to power.
DC motor principles Speed control Direction Stepper motor principles
April 24, 2015 FlexBus TM and FlexCards TM. 2 © Red Lion Controls Inc. FlexBus What is FlexBus?  A parallel bus that expands the option card capability.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
Digital Instrumentation Topics Multimeters Digital Multimeters (DMMs) Specifications (Display,Accuracy, Resolution) Meter Applications.
Power Budget Automation System Team #40 Hai Vo, Ho Chuen Tsang, Vi Tran ECE 445 Senior Design April 30 st, 2013.
1 Lab 4: D/A Converter Lab 4: D/A Converter This is a simple resistive network for a D/A converter Port 1, Port 0 are digital inputs ==> 00 (minimum),
Workshop 2013 Indication. 2 © Red Lion Controls Inc.  PAX2 Series Update  Expanding Our Range Indication Goals.
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
Site Controller Unit and Trunk Interface Unit
New EM210_AV.
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
Newton-500 Series CAS Corporation CAS Marketing Team.
HD SIGNAL CONDITIONER SERIES
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
LDA Large Display for Analog Inputs
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Lesson 8: Analog Signal Conversion
Presentation transcript:

1 Chang Shuan Electronics Co., Ltd

2 ST SERIES FAMILY

3 ST Signal Transmitter ST-VA ST-VA Voltage / Current Controllers 0~600V / 0~10A for DC/AC/TRMS ST-PR ST-PR Linear Process Controllers 0~10V & 0(4)~20mA all in one ST-SG ST-SG Stain Gauge Controllers 1.0/2.0/4.0 ~ 10.0/20.0/40.0 mV/V 1.0/2.0/4.0 ~ 10.0/20.0/40.0 mV/V ST-PM ST-PM PotentioMeter Controllers 0~2.0K / 0~50.0K ohm (3 Wired) 0~2.0K / 0~50.0K ohm (3 Wired) ST-T ST-T Temperature Controllers Pt100 ohm / Thermocouple K,J,E,T,R,S,B. Pt100 ohm / Thermocouple K,J,E,T,R,S,B. ST-RL Linear Speed / Rotation Controllers 0.01~100KHz /~140KHz (Optional), NPN/PNP/Contact/Vp 0.01~100KHz /~140KHz (Optional), NPN/PNP/Contact/Vp /30~600Vp /30~600Vp ST-LC Math ( +- X ÷ ) Conditioner with LED Display 0~10V & 0(4)~20mA / 1.0/2.0/4.0 ~ 10.0/20.0/40.0 mV/V 0~10V & 0(4)~20mA / 1.0/2.0/4.0 ~ 10.0/20.0/40.0 mV/V

Features of ST series 1 relay output, Analogue output, and RS 485 Communication can be selected at same Meter 1 relay output  Hi / Lo / Hi.HLd / Lo.HLd / do  with Start Delay / Hysteresis / Energized & De-energized Delay / DO / Relay Energized Hold….. Relay Energized Hold….. Analogue output Analogue output  Analogue High and Low settable as zoom-in function  Analogue output high limited function RS 485 port RS 485 port  Address number 1~255, Baud Rate from 2400~38400 bps  Showing data in display screen from Modbus RTU mode 06 function

Display  Present Value (PV) / Maximum or Minimum Hold / RS485 writing  Low Cut, Average, Digital Filter, Scaling, Digital Fine adjustment…..

1 Relay Output 1 Relay Output  Hi / Lo / Hi.HLd / Lo.HLd / do Hi: High Limit Energized, when the PV >= Set-point Hi: High Limit Energized, when the PV >= Set-point Lo: Low Limited Energized, when the PV <= Set-point Lo: Low Limited Energized, when the PV <= Set-point Hi.HLd (Lo.HLd): High (Low) Limit Energized continuously Hi.HLd (Lo.HLd): High (Low) Limit Energized continuously until manual reset by front key or External Control Input (ECI) until manual reset by front key or External Control Input (ECI) do: Relay energized according the RS485 command do: Relay energized according the RS485 command

7 Start Delay / Hystersis / Relay energized Start Delay / Hystersis / Relay energized delay / Relay De-energized delay delay / Relay De-energized delay Start Delay Start Delay Hysteresis: Settable range from 0~9999 Counts Hysteresis: Settable range from 0~9999 Counts Relay energized delay: Settable range from Relay energized delay: Settable range from 0.1(second)~9(minutes)59.9(seconds); 0.1(second)~9(minutes)59.9(seconds); Relay de-energized delay: Settable range from Relay de-energized delay: Settable range from 0.1(second)~9(minutes)59.9(seconds) 0.1(second)~9(minutes)59.9(seconds)

Analogue output Analogue output Accuracy: ≦  0.1% of F.S.; 16 bits AD converter Accuracy: ≦  0.1% of F.S.; 16 bits AD converter Response time: ≦ 200 msec. (10~90% of input) Response time: ≦ 200 msec. (10~90% of input) Isolation: AC 2.0 KV between input and output Isolation: AC 2.0 KV between input and output Functions: Functions:  Ao.Hi(output high): PV Hi vs. output range Hi  Ao.Lo(output range Low): PV Low vs. output range Lo  Ao.LMt(output High Limit): 0.00~110.00% of output High

RS 485 port RS 485 port  Modbus RTU Mode Address: 1~255. Address: 1~255. Baud Rate: 1200 / 2400 / 4800 / 9600 / / selectable. Baud Rate: 1200 / 2400 / 4800 / 9600 / / selectable. Parity: Even / Odd / None parity, 8 data bits, 1 stop bit / None Parity: Even / Odd / None parity, 8 data bits, 1 stop bit / None parity, 8 data bits, 2 stop bit selectable. parity, 8 data bits, 2 stop bit selectable.  Can read External Control Input (ECI) status  Can send the data to display screen by Modbus command

10 Specification ST-VA  Measuring: Vdc, Vac, Adc, Aac) / 0~600V or 0~10A  Accuracy): DC: ± 0.04% F.S.± 1 count; AC: ± 0.1% F.S.± 1 count  Display: ~29999, 0.28” high bright LED -PR ST-PR  Measuring: 0~(5)10Vdc & 0(4)~20mAdc All in one  Accuracy: ± 0.04% F.S.± 1 count  Display: ~29999, 0.28” high bright LED ST-SG  Measuring: 0~1.0/~2.0/~4.0/~10.0/~20.0/~40.0mV/V specify  Accuracy: ± 0.04% F.S.± 1 count  Display: ~29999, 0.28” high bright LED

11 Specification -PM ST-PM  Measuring: 0.0~2.0KΩ/~100.0KΩ (3 wired)  Accuracy: ± 0.04% F.S. ± 1 count  Display: ~29999, 0.28” high bright LED -RS ST-RS  Measuring: 0.1~200Ω/~2000Ω/~20.0KΩ/~200.0KΩ (2 wired)  Accuracy: ± 0.04% F.S. ± 1 count  Display: ~29999, 0.28” high bright LED -T ST-T  Measuring: Pt100Ω (3 wired) / Thermocouple K,J,E,T,R,S,B..  Accuracy): Pt100Ω: ± 0.1% F.S. ± 1 count Thermocouple K,J,E,T: ± 0.2% F.S. ± 1 count Thermocouple K,J,E,T: ± 0.2% F.S. ± 1 count Thermocouple R,S,B: ± 0.3% F.S. ± 1 count Thermocouple R,S,B: ± 0.3% F.S. ± 1 count  Display: ~29999, 0.28” high bright LED

12 Specification -RL ST-RL  Measuring: 0~100KHz(140KHz max.), decimal point auto set  Accuracy: ± 0.005% F.S. ± 1 count  Display: 0~99999, 0.28” high bright LED  Input mode: NPN / PNP / Vp changeable by Dip Switch on top pcb -LC ST-LC  Measuring: 2 inputs (internal isolated) 0~(5)10Vdc / 0(4)~20mAdc specify 2 inputs (internal isolated) 0~(5)10Vdc / 0(4)~20mAdc specify 0~1.0/~2.0/~4.0/~10.0/~20.0/~40.0mV/V specify; selectable 2 0~1.0/~2.0/~4.0/~10.0/~20.0/~40.0mV/V specify; selectable 2 different input signals different input signals  Accuracy: ± 0.04% F.S. ± 1 count  Display: ~29999/99999(mathematic), 0.28” high bright LED

13 Applications

14 Applications