HYDRO MULTI-B – Pressure boosting made simple.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
MAGNA3 – “built on a proven foundation”
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Total HVAC Control from anywhere Easy control that can save a fortune
AC Inverter Drives 500 Series Product Range Overview 2000 AC Inverter Drives.
` ACEEE HOT WATER FORUM ACT D’MAND KONTROLS® SYSTEM February 16 th 2015 PRESENTED BY LARRY ACKER “Designed for today, Dedicated to the Future®”. 1.
Expect More. World’s leader in pressure technology NA Sales Training Rev B – 10/10/13.
NH 3 BASED SCREW COMPRESSOR CHILLER. We use Alfa-Laval (Sweden) make WPHEs in the evaporator as well as the condenser(optional) in the chilling system.
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Booster System Basics: Constant Speed Systems
FORD FIELD BOOSTER Aqua~FloPacTM
Lindab Pascal - Simplified VAV solution with full potential...
Select the Appropriate Pumps and Controls. © Irrigation Association Understanding Basic Pump Selection Considerations Matching the pump and system Flat.
Efficient flexibility in room management with SAUTER EY-modulo.
One solution, many application Integrated Electronic Solution PowerSupply Flex.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
AccuMax Multi-Point Injection Mechanics
Demystifying SelfSensing Pumps. Design Operating Point 300 Gallons Per Minute 53 Feet of Head System Curves 150 ton 12deg Delta T 60 GPM each.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Kinetix 3 Component Servo Drive
The Smart Pumper TM enables you to create an Automated Smart Field today with One Device Patented Precision Pump Control based on real time fluid level.
SubDrive Constant Pressure Controller
A tour of new features Introducing the PATTERSON VIL-VS.
1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY.
Teezle TMatics M2M Platform & Solutions Overview January 28 th, 2014.
Melcotel TM Features and Benefits Melcotel - Introduction New features –Links with up to 250 room units –Settings reset –Automatic switch OFF –Setback.
1 Sales Academy Training Inner Range Product Advantages, Competitors & The Future.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
MAGNA3 vs. MAGNA.
Single Loop Analogue addressable fire control Panel
Page 1 May 2010 © Siemens AG 2010 Industry / Drive Technologies Innovative Hybrid Drive Systems for Commercial Vehicles Industry – Drive Technologies Innovative.
1 Upon completion of this training one should be able to: Identify different types of hydronic heating systems Identify key components in a simple hydronic.
MonoDrive & XT Constant Pressure Controller
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
1. Footer Date SpiralAIR Product Introduction People. Passion. Performance.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Chiller control system Lukasz Zwalinski – PH/DT.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
HYDRO MULTI-B – Pressure boosting made simple The CU323 1) Power in. 2) Internal Geni 3) Optional CIM Module 4) Analog input 5) PTC terminals 6) DI terminals.
Pressure Governor System Electronics. 2 Sentry Pressure Governor System Description The Sentry Pressure Governor System (SPGS) is a J1939 CAN based pressure.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Machine Condition Monitoring on ControlNet RSLogix5000 support for XM ®
1 Transitioning TAC I/A Series ™ to SmartStruxure ™ solution 11 June 2016.
Solar Pumps- High profitability and reliability lead to prosperity.
Integrated Blower Packages Kaeser Integrated Blower Family.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
Altivar Process Unique Value Propositions. Drives vision Extend drives sales from Transactional to Solutions & Segments Best in Class Products Solutions.
It’s…….
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
Avaya VA Line-interactive UPS
The New C55* CPVSd 10-20hp People. Passion. Performance.
SCALA2 landing page Digital content for distributors
HIGH PERFORMANCE PRESSURE SYSTEMS.
Parul Institute of Technology
OH3 or OH5 Direct Drive API 610 Centrifugal Pumps
Traditional Water Booster System
Solar Drive Enclosure and ATV312 Solar Drive
Champion RotorChamp HP
Geothermal Alliance of Illinois
Champion RotorChamp HP
Presented by Mike Zacharias
WEMCO® Hydrogritter® II Complete Grit Removal Package
Presentation transcript:

HYDRO MULTI-B – Pressure boosting made simple

NAMREG - Objective of Multi-B system Fill the gap where Hydro MPC is too large, too complicated and too expensive in markets for constant pressure booster systems. Compliment the current Grundfos Booster Program Differentiate with BoosterpaQ Hydro MPC systems Advance E-solutions benefits to customers Open up sales to other channels Increase overall Grundfos booster system sales Competitively Priced Booster System offering (60-70% of comparable BoosterpaQ system)

Hydro Multi-B - What, Why and How ? SYSTEM OVERVIEW APPLICATIONS SIMPLE TO USE COMPACT SPEED CONTROLLED PUMPS INTEGRATED VFD ENERGY EFFECTIVE ONE SUPPLIER SAFETY FEATURES COMMUNICATION COLLATEROL

Multi-B Pump System – System Overview Simple to use all VFD control pumping system NSF 61/UL372 Drinking Water Approval & UL Listed Packaged Pumping System 2-3 pump systems, CME pumps (I-Version – 304SS) Pump Size: 1.5HP – 7.5HP (CME3 – CME15) Communication capability using CIM cards 36 Catalog P/N systems

Hydro Multi B/E Booster Control Panel Pressure Transducer (Discharge Manifold) Discharge manifold (316 SS) Suction manifold (316SS) CME pumps (I-version 304SS) Oval Flange connection (two per pump)* Pump Isolating Valves (two per pump) Check Valve (one per pump)

Performance Range Q max: 330 gpm H boost max: 231 ft (100 psi boost) Max Working pressure – 232 psi

Applications for Hydro Multi B pump systems Domestic water pressure boosting Pressure boosting in multistory buildings Apartment Buildings Small Hospitals Hotels Large homes Rural areas requiring pressure boosting Anywhere redundant pumping is required

SIMPLE TO USE! Extremely simple HMI! (CU323 controller) Same platform as CU352 controller Automatically ensures best operation in all situations: Number pumps in operation Energy optimized cascade control No need for highly specialized people to operate the system. Less risk for improper use.

Compact! => Easier to retrofit into existing building. => Easier to retrofit existing end suction pumps

Speed controlled Pumps The Multi-B is equipped with speed controlled pumps, which enables the system adapt perfectly to the demand of the system. Operates at a constant pressure Quiet Operation Benefits include: Energy savings. Less wear of pipes due to less risk of water hammer or surges. Smaller diaphragm tank needed High comfort for users due to constant pressure and quite operation.

Integrated VFD – MLE The CME Pump is equipped with integrated VFD/motor combination – MLE The motor and VFD are perfectly matched. Quite operation Some MLE motors use permanent magnet motors 1x230V – up to 2HP 3x460V – up to 3HP MLE motors using permanent magnet motors have combined efficiency (motor + VFD) greater than NEMA Premium Efficient motors alone.

Energy effective The Multi-B has several features that makes it energy efficient. VFD operation ensures that the system delivers exactly what is needed and nothing more. Automatic cascade that makes sure that the optimum number of pumps are running at all time. Special software that ensures low energy consumption during low flow. => Save electricity => Less carbon emission.

One supplier! Grundfos designs, manufactures and assembles all major components of the system. Pumps Motor/VFD System components – Manifolds Controller (CU323) Single Source Responsibility! System undergoes complete system test before leaving the Factory.

Alarms and warnings Dry-running alarm Sensor fault Max. pressure exceed (Setpoint+22 psi) alarm All pumps alarm E-pump alarm Dry running alarm can be set to manual restart, all alarms and warnings can be reset automatically when the actual alarm disappears

=> Protects system against costly breakdowns Safety Features The Multi-B monitors several parameters to ensure that the system is run in a safe way. Water shortage protection (3-5 psi pressure switch standard) Sensor fault protection Max. pressure exceed (Setpoint+22 psi) alarm High voltage, low voltage & loss of phase on input power Monitors if system is outside duty range => Protects system against costly breakdowns

Communication Capable to communicate through the most common BUS protocols using CIM expansion cards. BACnet LON Modbus GRM Can connect into BMS and gives the operator full control of the system. Makes it possible to get alarms remotely, ensuring fast respond to alarms.

Benefits of Grundfos manifolds Reduced pressure drop with smooth transition No stagnant water areas in manifold What are the benefits of the T-drill machining process of the manifold? Key words: No pipe necks Reduced dead water zones (rounded edges) No gaps and cracks reduced hydraulic losses Reduced noise emission Reduced vortex generation when the pumped liquid passes through the manifold

Manifolds

Sales Collateral Sales Brochure Lit# L-PB-SL-003 Data Booklet I&O Manual Lit# 98504518 Quick Guide I&O Lit# 98515759

Summarized “Elevator” talking points All VFD controlled booster pump system – Energy Efficient Optimized Simple to use controller NSF 61/UL372 Drinking Water Approval UL Listed Packaged Pumping System Plug-n-Pump – Single Point Power Connection All Grundfos Components – Single Source Responsibility SCADA Communication capable Super COMPACT booster pumping system! Competitively Priced!

Release of Multi-B in NAMREG Estimated release date for orders: March 3rd, 2014 Standard Lead Time for Multi-B systems will be 4 weeks Stocking Programs for distribution channel

Multi-B compliments the Grundfos Booster program

Key elements of differentiation with Hydro MPC BoosterpaQ a “Non-CR” pump Simple controller (Not MPC) Limited to 2-3 pump systems Limited flow performance range (330 gpm) Total of (36) Catalog P/N systems 2 and 3 pump systems only Limited functionality compared to Hydro MPC BoosterpaQ Catalog P/N systems only (no options available) Target price is 60-70% of Hydro MPC BoosterpaQ

On/Off Button Pump status LED Pump Auto/off Up Button Pump number Set point Pump manual stop LED Down Button Auto LED Water Shortage Sensor Fault LED System Reset Process value System running LED System alarm LED