This article and any supplementary material should be cited as follows: Picerno P, Viero V, Donati M, Triossi T, Tancredi V, Melchiorri G. Ambulatory assessment.

Slides:



Advertisements
Similar presentations
This article and any supplementary material should be cited as follows: Paquet N, Taillon-Hobson A, Lajoie Y. Fukuda and Babinski-Weil tests: Within-subject.
Advertisements

This article and any supplementary material should be cited as follows: Mazzoleni S, Van Vaerenbergh, J, Stokes E, Fazekas G, Dario P, Guglielmelli E.
This article and any supplementary material should be cited as follows: Cameron MH, Huisinga J. Objective and subjective measures reflect different aspects.
This article and any supplementary material should be cited as follows: Kumar SN, Omar B, Htwe O, Joseph LH, Krishnan J, Jafarzedah Esfehani A, Min LL.
This article and any supplementary material should be cited as follows: Barton JE, Sorkin JD. Design and evaluation of prosthetic shoulder controller.
This article and any supplementary material should be cited as follows: Jeyasurya J, Van der Loos HF, Hodgson A, Croft EA. Comparison of seat, waist, and.
This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial.
This article and any supplementary material should be cited as follows: Eicholtz MR, Caspall JJ, Dao PV, Sprigle S, Ferri A. Test method for empirically.
This article and any supplementary material should be cited as follows: Meier MR, Tucker KA, Hansen AH. Development of inexpensive prosthetic feet for.
This article and any supplementary material should be cited as follows: Smit G, Plettenburg DH, van der Helm FCT. Design and evaluation of two different.
This article and any supplementary material should be cited as follows: Wininger M, Crane B. Effect of interpolation on parameters extracted from seating.
This article and any supplementary material should be cited as follows: Makowski P, Knutson J, Chae J, Crago P. Interaction of poststroke voluntary effort.
This article and any supplementary material should be cited as follows: Bickel CS, Gregory CM, Azuero A. Matching initial torque with different stimulation.
This article and any supplementary material should be cited as follows: Larson GE, Norman SB. Prospective prediction of functional difficulties among recently.
This article and any supplementary material should be cited as follows: Raya MA, Gailey RS, Gaunaurd IA, Ganyard H, Knapp-Wood J, McDonough K, Palmisano.
This article and any supplementary material should be cited as follows: Barks L, Luther SL, Brown LM, Schulz B, Bowen ME, Powell-Cope G. Development and.
This article and any supplementary material should be cited as follows: Akbari M, Jafari H, Moshashaee A, Forugh B. Do diabetic neuropathy patients benefit.
This article and any supplementary material should be cited as follows: Nilsson L, Durkin J. Assessment of learning powered mobility use— Applying grounded.
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements.
This article and any supplementary material should be cited as follows: Morgan P, Embry A, Perry L, Holthaus K, Gregory CM. Feasibility of lower- limb.
This article and any supplementary material should be cited as follows: Laciuga H, Rosenbek JC, Davenport PW, Sapienza CM. Functional outcomes associated.
This article and any supplementary material should be cited as follows: Levy CE, Silverman E, Jia H, Geiss M, Omura D. Effects of physical therapy delivery.
This article and any supplementary material should be cited as follows: Kim J, Park H, Bruce J, Rowles D, Holbrook J, Nardone B, West DP, Laumann AE, Roth.
This article and any supplementary material should be cited as follows: Ekiz T, Doğan Aslan M, Özgirgin N. Effects of Kinesio Tape application to quadriceps.
This article and any supplementary material should be cited as follows: Zeller S, Abel T, Smith PM, Strueder HK. Influence of noncircular chainring on.
This article and any supplementary material should be cited as follows: Watson EC, Cosio D, Lin EH. Mixed-method approach to veteran satisfaction with.
This article and any supplementary material should be cited as follows: Collins MP, Liu CF, Taylor L, Souza PE, Yueh B. Hearing aid effectiveness after.
This article and any supplementary material should be cited as follows: Oleson CV, Seidel BJ, Zhan T. Association of vitamin D deficiency, secondary hyperparathyroidism,
This article and any supplementary material should be cited as follows: Schoeman M, Diss CE, Strike SC. Asymmetrical loading demands associated with vertical.
This article and any supplementary material should be cited as follows: Kang YS, Park YG, Lee BM, Park HS. Biomechanical evaluation of wrist- driven flexor.
This article and any supplementary material should be cited as follows: Wu TM, Chen DZ. Biomechanical study of upper-limb exoskeleton for resistance training.
This article and any supplementary material should be cited as follows: Barfield JP, Malone LA. Perceived exercise benefits and barriers among power wheelchair.
This article and any supplementary material should be cited as follows: Russell TG, Hoffmann TC, Nelson M, Thompson L, Vincent A. Internet- based physical.
This article and any supplementary material should be cited as follows: Guidali M, Keller U, Klamroth-Marganska V, Nef T, Riener R. Estimating the patient’s.
This article and any supplementary material should be cited as follows: Ferguson-Pell M, Ferguson-Pell G, Mohammadi F, Call E. Applying ISO Standard.
This article and any supplementary material should be cited as follows: Rine RM, Roberts D, Corbin BA, McKean-Cowdin R, Varma R, Beaumont J, Slotkin J,
This article and any supplementary material should be cited as follows: Nunes PM, de Oliveira DG, Aruin AS, dos Santos MJ. Relationship between hand function.
This article and any supplementary material should be cited as follows: Mahajan HP, Spaeth DM, Dicianno BE, Brown K, Cooper RA. Preliminary evaluation.
This article and any supplementary material should be cited as follows: Zhang M, Davies TC, Zhang Y, Xie S. Reviewing effectiveness of ankle assessment.
This article and any supplementary material should be cited as follows: Sandroff BM, Hubbard MS, Pilutti LA, Motl RW. No association between body composition.
This article and any supplementary material should be cited as follows: Khattab A, Docherty S, Bagust J, Willington R, Thomas P, Amar K. Subjective visual.
This article and any supplementary material should be cited as follows: Eyskens JB, Nijs J, D’Août, Sand A, Wouters K, Moorkens G. Timed loaded standing.
This article and any supplementary material should be cited as follows: Umpierres CS, Ribeiro TA, Marchisio ÂE, Galvão L, Borges ÍN, Macedo CA, Galia CR.
This article and any supplementary material should be cited as follows: Alcaide-Aguirre RE, Morgenroth DC, Ferris DP. Motor control and learning with lower-limb.
This article and any supplementary material should be cited as follows: van Nunen MP, Gerrits KH, de Haan A, Janssen TW. Exercise intensity of robot-assisted.
This article and any supplementary material should be cited as follows: Moloney NA, Hall TM, Doody CM. Reliability of thermal quantitative sensory testing:
This article and any supplementary material should be cited as follows: Fu J, Jones M, Jan Y. Development of intelligent model for personalized guidance.
This article and any supplementary material should be cited as follows: Ickmans K, Clarys P, Nijs J, Meeus M, Aerenhouts D, Zinzen E, Aelbrecht S, Meersdom.
This article and any supplementary material should be cited as follows: Cater JK. Traumatic amputation: Psychosocial adjustment of six Army women to loss.
This article and any supplementary material should be cited as follows: Ishikawa S, Stevens SL, Kang M, Morgan DW. Reliability of daily step activity monitoring.
This article and any supplementary material should be cited as follows: Marchiori C, Bensmail D, Gagnon D, Pradon D. Manual wheelchair satisfaction among.
This article and any supplementary material should be cited as follows: Redfield MT, Cagle JC, Hafner BJ, Sanders JE. Classifying prosthetic use via accelerometry.
This article and any supplementary material should be cited as follows: Keser I, Kirdi N, Meric A, Kurne AT, Karabudak R. Comparing routine neurorehabilitation.
This article and any supplementary material should be cited as follows: Koester HH, Simpson RC. Method for enhancing text entry rate with single-switch.
This article and any supplementary material should be cited as follows: Berning K, Cohick S, Johnson R, Miller LA, Sensinger JW. Comparison of body-powered.
This article and any supplementary material should be cited as follows: Maitre J, Jully JL, Gasnier Y, Paillard T. Chronic physical activity preserves.
This article and any supplementary material should be cited as follows: Hebert JS, Lewicke J. Case report of modified Box and Blocks test with motion capture.
This article and any supplementary material should be cited as follows: Hebert JS, Lewicke J, Williams TR, Vette AH. Normative data for modified Box and.
This article and any supplementary material should be cited as follows: Gailey RS, Gaunaurd IA, Raya MA, Roach RE, Linberg AA, Campbell SM, Jayne DM, Scoville.
This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art.
This article and any supplementary material should be cited as follows: Ficanha EM, Rastgaar M, Kaufman KR. Ankle mechanics during sidestep cutting implicates.
This article and any supplementary material should be cited as follows: Tsai J, Rosenheck RA. Homeless and nonhomeless VA service users likely eligible.
This article and any supplementary material should be cited as follows: Hollington J, Hillman SJ. Can static interface pressure mapping be used to rank.
This article and any supplementary material should be cited as follows: Resnik L, Klinger SL, Etter K. User and clinician perspectives on DEKA Arm: Results.
This article and any supplementary material should be cited as follows: Sensinger JW, Lipsey J, Thomas A, Turner K. Design and evaluation of voluntary.
This article and any supplementary material should be cited as follows: Sloan DM, Bovin MJ, Schnurr PP. Review of group treatment of PTSD. J Rehabil Res.
This article and any supplementary material should be cited as follows: Smit G, Plettenburg DH. Comparison of mechanical properties of silicone and PVC.
This article and any supplementary material should be cited as follows: Worobey LA, Udofa IA, Lin Y, Koontz AM, Farrokhi SS, Boninger ML. Reliability of.
This article and any supplementary material should be cited as follows: Major MJ, Johnson WB, Gard SA. Interrater reliability of mechanical tests for functional.
This article and any supplementary material should be cited as follows: Wessles KK, Brown JL, Ebersole KT, Sosnoff JJ. Sex, shoulder pain, and range of.
Presentation transcript:

This article and any supplementary material should be cited as follows: Picerno P, Viero V, Donati M, Triossi T, Tancredi V, Melchiorri G. Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor. J Rehabil Res Dev. 2015;52(2):XX–XX. Slideshow Project DOI: /JRRD JSP Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor Pietro Picerno, PhD; Valerio Viero, MSc; Marco Donati, PhD; Tamara Triossi, MSc; Virginia Tancredi, PhD; Giovanni Melchiorri, PhD

This article and any supplementary material should be cited as follows: Picerno P, Viero V, Donati M, Triossi T, Tancredi V, Melchiorri G. Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor. J Rehabil Res Dev. 2015;52(2):XX–XX. Slideshow Project DOI: /JRRD JSP Aim – Assess reliability of using a single inertial measurement unit (IMU) for determining strength curves during isoinertial exercises. Relevance – Strength curves have typically been measured with isometric and isokinetic dynamometers, which are expensive and cumbersome for clinicians.

This article and any supplementary material should be cited as follows: Picerno P, Viero V, Donati M, Triossi T, Tancredi V, Melchiorri G. Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor. J Rehabil Res Dev. 2015;52(2):XX–XX. Slideshow Project DOI: /JRRD JSP Method 45 men and women without previous/current shoulder impairment and not involved in professional sports participated. Seated subjects performed 1 consecutive shoulder abduction-adduction movement while holding 1 kg dumbbell. Strength curve relative to shoulder abduction movement was assessed using wireless IMU fixed to upper arm.

This article and any supplementary material should be cited as follows: Picerno P, Viero V, Donati M, Triossi T, Tancredi V, Melchiorri G. Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor. J Rehabil Res Dev. 2015;52(2):XX–XX. Slideshow Project DOI: /JRRD JSP Results High intraclass correlation coefficient values for range of motion and angular velocity. – Indicates high within-subject repeatability of task. High waveform similarity of torque curves between trials. With respect to isokinetic dynamometer, high IMU accuracy in estimating range of motion. – Error always <1 .

This article and any supplementary material should be cited as follows: Picerno P, Viero V, Donati M, Triossi T, Tancredi V, Melchiorri G. Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor. J Rehabil Res Dev. 2015;52(2):XX–XX. Slideshow Project DOI: /JRRD JSP Conclusion A single wearable IMU can effectively assess strength curves during isoinertial movements. Clinicians could easily apply this method in ambulatory settings and, hence, use it as routine diagnostic tool for assessing functional joint recovery.