Insert White, Black and Yellow Wires into Switch Terminals as Shown Rotate Switch to Bend Wires. The Wires Should be Bent as Close to the Terminal End.

Slides:



Advertisements
Similar presentations
Activity 1.2.5a Mechanical Efficiency
Advertisements

1 Telephone Connection. 2 Introduction The section instructs you on how to install a required phone line to every receiver.
Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Electricity Lesson II Electrical Symbols EE.
Assembly Manual Mike Fortney 04/09/2004 CricketSat Receiver.
CricketSat Receiver Assembly Instructions This is the instruction slides for the assembly of a receiver board. It would be a good idea to review soldering.
Condensate Trap Heater KGAHT0201KIT 2013 Fall Zone Meeting Gary Georgette/Jerry Shipman UTC Climate, Controls & Security Confidential and Proprietary Information.
Insert White, Black and Yellow Wires into Switch Terminals as Shown.
Wiring Color Codes for McLean County 4-H Projects.
MOOD LIGHT PCB ASSEMBLY V By Phil Townshend 2008.
CricketSat LP (Transmitter) Assembly Instructions This is the instruction slides for the assembly of a transmitter board. This is the board that will fly.
Electrical wiring Household skills. Power Grid All electrical devices in your home are physically connected to a power generating facility You will not.
Electronics Merit Badge Class 4 5/17/2015Electronics Merit Badge Class National Scout Jamboree1.
DC234KL Dust Extraction Adaptor rebuild Reason for change –In 2010 a cordless dust extraction unit was brought to the market. –When connecting the cordless.
Making A Motor Exploring the Magic of Electricity.
American Electrical, Inc. Junction Box / Hookup Box Fast and easy way to make electrical connections An assembled kit – no need to procure and assemble.
© red ©
Wire bundles connecting to Keyence Sensors (screw plug on other end) Colored Wires from bundles (brown, blue, white are nonfunctional, cap with scotch.
Robot Build IT Girls Allowed 2014 Updated 14 th August.
Electrical Wiring Three-Way Switches. Three-Way Switch.
Wiring the Desklamp Basics of Wiring. Types of Wire For this project we will be using two types of wire: 3 wire and standard lamp wire. – 3 wire The wire.
Assembly of Conductivity Flow Loop EAS 199B living with the lab (in preparation for calibrating conductivity sensor)
Basic Electricity Facts and Diagrams. Romex Types Determine your need to determine the type of Romex needed Gage Size of the wire (common = 12 or 14)
MC11000 Kit Replacement 1 1. Open the face plate and remove the 2 screws. Remove and discard the original face plate. 3. Remove the 2 white caps on the.
LAUNCHER BASE PARTS B A D E F C G. LAUNCHER BASE PARTS B A D E F C G.
12. Power Distribution Systems 1) Schematic diagram of part of a house wiring system 1.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
THERMOMETER PROJECT PCB ASSEMBLY INSTRUCTIONS.
BIX In-Building Cross Connect system BIX Installation Guide ELCM 254 Updated December 2013 gmail.com 1 Most of the images and some text for.
ASSEMBLING THE PCB – V3.914 Hold the PCB as shown below.
Basic Electricity Facts and Diagrams. Cable Types Determine your need to determine the type of cable (Romex) needed Gage Size of the wire (common = 12.
Front view LED’s pushed into place Buzzer bolted on Fuse holder bolted on.
P:\ISO \Work Instructions\Assembly\Options\ARMADILLO SWEEPER OPTIONS\10X ARMADILLO SWEEPER OPTIONS MODEL: KIT-MFG-ENG SHDN DSL M&FS SWA.
ASSEMBLING THE PCB Have the PCB in front of you as shown. Make sure there are no copper tracks showing. This side is called the component side.
Easy Reach 7.0 Honda Element Packing List QtyDescriptionPacked 115ft 10ga Red Wire 16ft 10ga Black Wire 140amp Breaker 23/8 Yellow Ring Terminals 25/16.
ASSEMBLING THE PCB Your PCB has two sides, a COMPONENT side and a TRACK side. The view below shows the component side.
Level 1 Diploma in Electrical Installation © 2014 City and Guilds of London Institute. All rights reserved. 1 of 13 PowerPoint presentation Stripping and.
Building controller with joystick and buttons. put joystick together (keep things in order below)
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
Installing Branch Circuits Unit #32. What are Wiring Boxes? hold cable or conduit and protect connections attached to building contain all electrical.
To install the four wires from the back of the coil machine, loosen the four knobs. Keep each wire in center under each knob, off to the side will allow.
PostBase Automatic Feeder Component Removal Service Training
A22N Series Pushbutton Switches/Indicators
Electricity Symbols.
Installing Branch Circuits
This picture shows what the wiring of a new alternator looks like
X-Spot Lamp Socket Replacement Procedure
Activity 1.2.5a Mechanical Efficiency
Schematic diagram of part of a house wiring system
Easy Reach 7.0 Honda Element 2003
Easy Reach 7.0 Honda Element 2003
Testbed 7) Wheel Assembly 6) Battery Strap 8) Clawbot 5) Limit Switch
Activity 1.2.5a Mechanical Efficiency
1) Schematic diagram of part of a house wiring system
Ignition Systems Overview
BIX In-Building Cross Connect system
Excel Basic Operation Manual
Activity 1.2.5a Mechanical Efficiency Winch Construction Guide
Activity 1.2.5a Mechanical Efficiency
Visual Instructions.
Horizontal Installation Overview
Activity 1.2.5a Mechanical Efficiency Winch Construction Guide
Electrical Wiring Single Pole Switches.
To install the four wires from the back of the coil machine, loosen the four knobs. Insert each of the four wires from the side under the knobs. Keep each.
Exploring the Magic of Electricity
THERMOMETER PROJECT PCB ASSEMBLY INSTRUCTIONS Ver: 3.21 edutek.ltd.uk.
What Color is it?.
Which of the following would best describe the situation inside the circle?
A22N Series Pushbutton Switches/Indicators
Presentation transcript:

Insert White, Black and Yellow Wires into Switch Terminals as Shown Rotate Switch to Bend Wires. The Wires Should be Bent as Close to the Terminal End as Possible. 115/120V switch

Insert White, Black and Yellow Wires into Switch Terminals as Shown Rotate Switch to Bend Wires. The Wires Should be Bent as Close to the Terminal End as Possible. Position the yellow wire loop as close to the black wire as possible. Route the white wire loop so that it crosses over the yellow wire as shown 230V switch

Insert Blue wire into back terminal on backside of switch

Insert Brush Holders as Shown.

Insert Left Side Brush Connect Brush Wire, to Back Terminal, on Front Side of the Switch 120V MOD 230V MOD

Insert Right Side Brush. Connect Wire into Front Terminal, on Back Side of the Switch 120V MOD 230V MOD

Brush Wires Routed in Field Case 120V MOD230V MOD

Route Brush Leads through wire traps in Fieldcase as shown

Place Drill SA into Handle and Fasten Together with Screw. Ensure NO Brush Wires are Damaged or Pinched by Screw. Ensure Brush Wires are Tucked Down Below Parting Line Rib

Connect Capacitor Leads to C1 and C2 on Back of Switch FOR 115V and 230V UNITS ONLY After Connecting the Capacitor to the Switch, place them in Handle and orient Capacitor as shown.

Connect Capacitor Leads to C1 and C2 of Switch FOR UNITS WITH CAPACITORS USING N & N After Connecting the Capacitor to the Switch, place them in Handle and orient Capacitor as shown.

Attach Cordset to Handle with Cord Clamp Ensure Cord Jacket is a MINIMUM of 3mm from Cord Clamp

Cordset Assembly (Marquardt): Insert Power Cord wires as shown; Blue or White wire into the push-in terminal L1 and Brown or Black wire into the push-in terminal L2. For Grounded Units, connect Ground wire to Gearcase. Use This Wire Trap on Side of Switch. Ensure Both Wires are Over Boss MOD with Cap Route All Wires through Wire Traps as Shown

Cordset Assembly (Capax): Insert Power Cord wires as shown; White wire to the right of the Quick Disconnect Lever (1) and Black wire in the push-in terminal to the left of the Quick Disconnect. For Grounded Units, connect Ground wire to Gearcase. Use This Wire Trap on Side of Switch. Run the Ground wire past the trigger as shown. Route all wires through wire traps as shown Ensure Both Wires are Over Boss 230V MOD