 The zigzag readout board is divided into eight η-sectors; each sector has a length of ~12 cm and comprises 128 zigzag strips; zigzag strips run in radial.

Slides:



Advertisements
Similar presentations
Study of Large-area GEM Detectors for a Forward Tracker at a Future Electron-Ion Collider Experiment Aiwu Zhang, Vallary Bhopatkar, Marcus Hohlmann Florida.
Advertisements

Kondo GNANVO Florida Institute of Technology, Melbourne FL.
Analysis for J2 chamber Yousuke Kataoka (University of Tokyo) Atsuhiko Ochi, Yuki Edo (Kobe University) 11 / 12 / 2012 Micromegas weekly meeting 1.
Behaviour of MicroMega chambers in magnetic field: analysis of H2 June data Outline: (0) Introduction (1) Data set used and noise filtering (2)Cluster.
E/π identification and position resolution of high granularity single sided TRD prototype M. Târzilă, V. Aprodu, D. Bartoş, A. Bercuci, V. Cătănescu, F.
Large-area GEM Detector with Zigzag Strip Readout Aiwu Zhang, Marcus Hohlmann, Vallary Bhopatkar, Jessie Twigger, Elizabeth Starling, Michael Phipps, Eric.
The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider.
CMS GEM Workshop III, April 20, 2012
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 technical workshop 03/17/ 2010 Jefferson lab Update on.
FNAL beam test results update -- tracking in (r,ϕ) plane for ref. detectors A. Zhang, V. Bhopatkar, M. Phipps, J. Twigger, M. Hohlmann HEP Group A, Florida.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 central detector meeting : 2 december 2009 Cea Saclay CERN.
Standalone VeloPix Simulation Jianchun Wang 4/30/10.
US CMS Phase 2 R&D Discussion 30-July-2013 “Phase 2 muon R&D” J. Hauser, UCLA  Add redundancy (power) to trigger where most needed  First and innermost.
Rate and Gain Measurements of the 1-m long GEM detector Aiwu Zhang EIC tracking R&D weekly meeting.
Beam Test Results for a Large-area GEM Detector Read Out with Radial Zigzag Strips Aiwu Zhang, V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger Dept. of.
Gain measurements of Triple Gas Electron Multiplier (GEM) detector with zigzag readout strips V. BHOPATKAR, E. ESPOSITO, E. HANSEN, J. TWIGGER M. HOHLMANN.
2012 IEEE Nuclear Science Symposium Anaheim, California S. Colafranceschi (CERN) and M. Hohlmann (Florida Institute of Technology) (for the CMS GEM Collaboration)
RD6 Progress January 2015 TK Hemmick for RD6. RD6 Core Program Summary Stony Brook University: CF 4 -based RICH for hadron ID at high momentum (EIC also.
Updates on GEMs characterization with APV electronics K. Gnanvo, N. Liyanage, K. Saenboonruang.
Study of Large-area GEM Detectors for a Forward Tracker at a Future Electron-Ion Collider Experiment Aiwu Zhang, Vallary Bhopatkar, Marcus Hohlmann Florida.
Status of straw-tube tracker V.Peshekhonov, D.Peshekhonov, A.Zinchenko JINR, Dubna V.Tikhomirov P.N.Lebedev Physics Institute, Moscow Presented on the.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
Construction and first commissioning of the self-stretched gas electron multiplier (GEM) detector J. Twigger, V. Bhopatkar, J. Wortman, M. Hohlmann 77th.
75 th Annual Meeting March 2011 Imaging with, spatial resolution of, and plans for upgrading a minimal prototype muon tomography station J. LOCKE, W. BITTNER,
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
Mitglied der Helmholtz-Gemeinschaft Calibration of the COSY-TOF STT & pp Elastic Analysis Sedigheh Jowzaee IKP Group Talk 11 July 2013.
Fermilab Test Beam analysis for CMS GE1/1-III GEM detector Aiwu Zhang, V. Bhopatkar, M. Hohlmann, A.M. Phipps, J. Twigger Florida Institute of Technology.
A Proposal: GE2/1 Readout with Zigzag Strips
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
GEM Detector R&D at Florida Tech – “Get to know each other” –
M. Staib, M. Abercrombie, B. Benson, K. Gnanvo, M. Hohlmann Department of Physics and Space Sciences Florida Institute of Technology.
Progress on the beam tracking instrumentation Position measurement device Tests performed and their resolution Decision on electronics Summary.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
Large-Area GEM Detector Development at CMS, RD51, and Fl. Tech – A brief overview – Marcus Hohlmann Florida Institute of Technology, Melbourne, FL PHENIX.
Cost Reduction for Gas Electron Multiplier Detector Readout Boards Using Zigzag Strips Elizabeth Starling Marcus Hohlmann Kimberley Walton, Aiwu Zhang.
FNAL Beam test results A. Zhang, V. Bhopatkar, M. Phipps, J. Twigger, M. Hohlmann HEP Group A, Florida Tech 2013/11/18.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
TEMPLATE DESIGN © CONFIG. 1: 12mm(Drift) / 12mm(T1) / 12mm(T2) / 12mm(Induction) CMS Endcap Resistive Plate Chamber Muon.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
GE1/1-III GEM Cluster Size and Resolution Studies with the FNAL Beam Test Data Aiwu Zhang, Vallary Bhopatkar, Marcus Hohlmann Florida Institute of Technology.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
FNAL beam test simulation with Geant Aiwu Zhang Florida Tech
RD51 GEM Telescope: results from June 2010 test beam and work in progress Matteo Alfonsi on behalf of CERN GDD group and Siena/PISA INFN group.
Irradiated 3D sensor testbeam results Alex Krzywda On behalf of CMS 3D collaboration Purdue University March 15, 2012.
FNAL beam test data analysis A Hands-on session at CMS Upgrade School Aiwu Zhang Florida Institute of Technology On behalf of the CMS GEM collaboration.
Performances of a GEM-based TPC prototype for the AMADEUS experiment Outline: GEM-TPC in AMADEUS experiment; Prototype design & construction; GEM: principle.
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
Trigger & Tracking detector for CMS
SRS TIMING ANOMALY RD51 Mini-Week June 9, 2015 M. Phipps, BNL 1.
Slow Control and Run Initialization Byte-wise Environment
Slow Control and Run Initialization Byte-wise Environment
Section N4A4 Gaseous Detectors: R&D II.
FCAL R&D towards a prototype of very compact calorimeter
Dept. of Physics and Space Sciences, Florida Institute of Technology
A. Zhang, S. Colafranceschi, M. Hohlmann
Integration and alignment of ATLAS SCT
Matthew Bomberger1, Francisco Izquierdo1, Aiwu Zhang2
Characterization and test beam results of novel triple-GEM
Development of Gas Electron Multiplier Detectors for Muon Tomography
EIC Tracking Meeting, March 26, 2012
J. Twigger, V. Bhopatkar, E. Hansen, M. Hohlmann, J.B. Locke, M. Staib
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Pre-installation Tests of the LHCb Muon Chambers
A. Zhang, S. Colafranceschi, M. Hohlmann
(On Behalf of CMS Muon Group)
Gain measurements of Chromium GEM foils
Presentation transcript:

 The zigzag readout board is divided into eight η-sectors; each sector has a length of ~12 cm and comprises 128 zigzag strips; zigzag strips run in radial direction and measure polar coordinates (φ).  The opening angle of the board is 10°; the angular pitch between zigzag strips is ~1.37 mrad.  Distance between two neighboring tips is 0.1 mm; distance between two tips in one strip is 0.5 mm.  GEM foils and drift frame are from a CMS-GEM prototype (GE1/1-III) for the CMS muon upgrade; gas gaps in the 3-GEM detector are 3/1/2/1 mm.  Only 8 APVs are needed to fully read out the detector, 2/3 of electronics are saved compared with 24 APVs in the CMS project w/ straight strips. Study of a Large-Area GEM Detector Read Out with Radial Zigzag Strips for Forward Tracking in Experiments at a Future Electron-Ion Collider A. Zhang, V. Bhopatkar, M. Hohlmann, E. Hansen, M. Phipps, E. Starling, J. Twigger, K. Walton Dept. of Physics and Space Sciences, Florida Institute of Technology, Melbourne, FL 32901, USA Introduction The RD6-FLYSUB consortium is performing R&D on tracking and particle ID with GEM detectors for a future Electron-Ion Collider (EIC). A 1m-long trapezoidal triple- GEM detector read out by 1,024 radial zigzag strips in eight  -sectors is an option under study for tracking in the forward region. The zigzag structure allows a threefold reduction in the required number of strips and electronic channels over a conventional straight-strip readout while preserving good spatial resolution. The geometry of this zigzag structure is briefly discussed. We report results from a beam test of this prototype with GeV hadrons at the Fermilab Test Beam Facility (FTBF). The readout design shows a typical cross-talk of not more than 6%. Spatial resolution and efficiency are studied as a function of high voltage and for different positions on the detector. The measured charged-particle detection efficiency of this detector on plateau exceeds 98%. With hit positions based on the barycenters of zigzag-strip clusters, the overall measured spatial resolution of the detector is ~240 μrad given a 1.37 mrad azimuthal pitch of the radial zigzag strips. The non-linearity of the zigzag-strip response is corrected using track information which improves the resolution to ~170 μrad, or 12% of the strip pitch. 4. Spatial Resolutions with Centroid Method 1. Zigzag Readout Strips & GEM detector 2. Setup in the Beam at Fermilab TBF  The zigzag GEM detector was tested at FTBF in a tracking system. Four standard GEM detectors worked as trackers (two in front and two in back).  All detectors were operated with Ar/CO 2 70:30.  Most of the data for the zigzag GEM were taken with 32 GeV/c mixed hadrons (p, π, and K). IEEE Nuclear Science Symposium & Medical Imaging Conference Seattle, WA USA 8-15 Nov Basic Performances of the Zigzag GEM  Cluster charge distribution fits well to a Landau function. A typical exp. ‘gain’ curve is obtained with the HV scan on the middle of sector 5.  Mean cluster size (number of strips in a cluster) is approximately an exponential function of HV. Mean cluster size at the highest voltage is less than 3 strips. 3200V, sector 5 ‘gain’ vs. HV 3200V, sector 5 Mean cluster size vs. HV  Time bin where the maximum signal appears in APV time window. At higher HV, the time bin is smaller because the signal pulse peaks earlier. Mean time bin vs. HV  Detection efficiency of the zigzag GEM is measured to be (98.4 ± 0.2) % with a 5σ threshold cut, where σ is the width of the pedestal distributions. Different thresholds are compared and consistent efficiencies are observed. Efficiency plateau width is about 250V.  The zigzag GEM was scanned at two points in each of sector at 3200V. The response in cluster charge varies by about 25% at different positions. This non-uniformity is most likely caused by slight bending of the drift board after foils are stretched. Efficiency Uniformity Exclusive 3300V Inclusive 3300V Resolution vs. HV in sector 5Resolutions at different positions  Resolution as a function of HV is plotted; resolutions with different cluster sizes are also compared. On the efficiency plateau, resolution is ~240 μrad.  Resolution at different positions are measured to be around 260 μrad. 5. Correction of Non-linear Strip Response and Resulting Resolution  The zigzag strips have non-linear response to signal collection due to their special structure, which biases the cluster centroids away from their true positions.  Correction method: Resolutions after correction HV scan data Sector scan middle positions Sector scan upper positions After corrections, the resolution on the efficiency plateau is improved to 170 μrad. We observed resolution improvements for all positions on the chamber. 6. Crosstalk among Zigzag Strips The zigzag strips #63 and #127 were grounded by mistake when the PCB was manufactured, which allows us to check the crosstalk between the strips experimentally. From pedestal widths, we estimate the mean cross talk on the ‘victim’ strips to be about 5-6%. 7. Conclusion & Outlook  The GEM detector with zigzag strip performed quite well in the beam test.  The efficiency is high; the response uniformity can be improved further.  The angular resolution of the detector reaches 170 μrad (170 μm at r = 1 m), or 8% of the strip pitch. Multiple scattering (for ~14% X 0 ) is not yet included in the analysis; we expect even better resolution after this effect is subtracted.  In conclusion, a GEM with zigzag strip readout is a viable and cost- effective option for forward tracking in an experiment at a future EIC. RD6-FLYSUB is a collaboration of researchers from BNL, Florida Institute of Technology, Lawrence Livermore National Lab., Stony Brook U., U. of Virginia, Weizmann Institute of Science and Yale U. formed to carry out R&D for tracking and particle identification for detectors for a future Electron-Ion Collider (EIC). We would like to acknowledge BNL for the support of this work (under the EIC-RD6 task force) and the staff of the FNAL test beam facility for all their help. ~1m ~45 cm ~22 cm subtracting  -dependent offsets given by the 2-strip and 3-strip fit functions from the original residuals. All clusters BEFORE corr.All clusters AFTER corr.