Datacenter Energy Efficiency Research: An Update Lawrence Berkeley National Laboratory Bill Tschudi July 29, 2004.

Slides:



Advertisements
Similar presentations
UPS Topologies and Multi-Module Configurations
Advertisements

Data Center Design Issues Bill Tschudi, LBNL
New Paradigms for Measuring Savings
NEMA. 2 Utility Metering vs. Submetering 10/11/2014 New PowerPoint Template Utility Meter Meter provided by utility with the purpose of measuring.
1 DOE Data Center Tools Suite Assessment Tool Development Electrical Example Lawrence Berkeley National Laboratory ANCIS EYP Mission Critical Rumsey Engineers.
Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Increasing the Efficiency of UPS Systems – And Proving It!
Variable Frequency Drives VFD Basics
PI – Monitoring Energy in the Data Center Peter Vieites Technology Architect Microsoft Technology Center - New York.
IBM Energy & Environment © 2008 IBM Corporation Energy Efficiency in the Data Centre … and beyond Peter Richardson UK Green Marketing Leader.
IT Equipment Efficiency Peter Rumsey, Rumsey Engineers.
1 Page 1 Public Interest Energy Research (PIER) California Institute for Energy & Environment (CIEE) Lawrence Berkeley National Laboratory Bill Tschudi.
Anand Vanchi- Intel IT Ravi Giri – Intel IT Sujith Kannan – Intel Corporate Services Comprehensive Energy Efficiency of Data Centers – Case study shared.
How Energy Efficiency and Demand Response can Help Air Quality Presentation to the California Electricity and Air Quality Conference October 3, 2006 Mary.
Datacenter Power State-of-the-Art Randy H. Katz University of California, Berkeley LoCal 0 th Retreat “Energy permits things to exist; information, to.
Energy Efficient Data Centers - an Update December, 2006 William Tschudi
All content in this presentation is protected – © 2008 American Power Conversion Corporation Rael Haiboullin System Engineer Capacity Manager.
My Ton – Ecos Consulting Brian Fortenbery – EPRI Solutions Bill Tschudi – Lawrence Berkeley National Laboratory Sponsored by: California Energy Commission.
Key Questions Behind Ecos Consulting’s Power Supply Research How many power supplies are out there? What does it mean for a power supply to be energy efficient?
24 x 7 Energy Efficiency February, 2007 William Tschudi
Reliability and Energy Efficiency – Not Mutually Exclusive
Creating Energy-Efficient Data Centers
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior.
Enabling High Efficiency Power Supplies for Servers : Update on industry, government and utility initiatives Brian Griffith System Power Architect Intel.
Data Centre Power Trends UKNOF 4 – 19 th May 2006 Marcus Hopwood Internet Facilitators Ltd.
Data Center Consolidation & Energy Efficiency in Federal Facilities
Connectivity Week Santa Clara Convention Center May 23, 2011.
Data Centers - They’re Back… E SOURCE Forum September, 2007 William Tschudi
Page 1 Public Interest Energy Research (PIER) California Institute for Energy & Environment (CIEE) Bill Tschudi Lawrence Berkeley National Laboratory
1 Page 1 Bill Tschudi Sponsored by: Public Interest Energy Research (PIER) California Energy Commission and administered by California.
Thermodynamic Feasibility 1 Anna Haywood, Jon Sherbeck, Patrick Phelan, Georgios Varsamopoulos, Sandeep K. S. Gupta.
LBNL and Government Data Center Programs SC07 November, 2007 William Tschudi
Energy Efficient Digital Networks Rich Brown Lawrence Berkeley National Laboratory Presentation to DOE State Energy Advisory Board Meeting August 14, 2007.
1 DOE Data Center Energy Efficiency Program and Tool Strategy Paul Scheihing U.S. Department of Energy Office of Energy Efficiency and Renewable Energy.
Overview of LBNL’s High-Tech Buildings Project Activities Bill Tschudi and Tim Xu April 21, 2004
My Ton – Ecos Consulting Brian Fortenbery – EPRI Solutions Bill Tschudi – Lawrence Berkeley National Laboratory Sponsored by: California Energy Commission.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Power Usage Effectiveness Index- Electrical Systems DATA CENTER Hareesha K Texas Instruments.
Federal Data Center Programs 7 X 24 Exchange October, 2007 William Tschudi
1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory
50th HPC User Forum Emerging Trends in HPC September 9-11, 2013
The Data Center Challenge
Energy Efficient Data Centers Update on LBNL data center energy efficiency projects June 23, 2005 Bill Tschudi Lawrence Berkeley National Laboratory
Electrical Systems Efficiency Bill Tschudi, LBNL
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
1 CTO Challenge William Tschudi February 27, 2008.
Data Center Energy Efficiency Sonoma Mountain Village November 29, 2007 William Tschudi
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
1 Data Centers for the 21st Century Working with Industry to Improve Energy Efficiency in Data Centers Dale Sartor, P.E. LBNL Applications Team June 7,
Environmental Energy Technologies datacenterstalk ppt Latest Measured Data on Data Center Power Use in the U.S. Jonathan Koomey, Ph.D. Lawrence Berkeley.
1 Page 1 Steve Greenberg Sponsored by: Public Interest Energy Research (PIER) California Energy Commission and administered by California.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
Welcome to Lawrence Berkeley National Laboratory Workshop on Energy Saving Opportunities in Cleanrooms March 15, 1999 Environmental Energy Technologies.
Metrics & TCO For Real Efficiency Improvements It’s About The Total Cost of Ownership My Friend.
MVDC Collaboration MVDC Issues and Viability of Red Demo in Philadelphia.
Data Center Energy: Going Forward John Tuccillo, APC by Schneider Electric Founding Board of Director Member.
Data Center Energy Efficiency SC07 Birds of a Feather November, 2007 William Tschudi
Energy Conference and Exhibition 2007 Best Practices for Energy-Efficiency in Critical Power Applications Kit Killingsworth.
Enabling High Efficient Power Supplies for Servers
Fort Stanwix National Monument Energy Audit Contract
The Data Center Challenge
Electrical Systems Efficiency
DOE Data Center Energy Efficiency Program and Tool Strategy
Data Center Research Roadmap
Data Center Research Activities
PowerValue 11 RT Sales Presentation
IT Equipment Efficiency
IT Equipment Efficiency
Presentation transcript:

Datacenter Energy Efficiency Research: An Update Lawrence Berkeley National Laboratory Bill Tschudi July 29, 2004

Data center energy efficiency research and deployment sponsors California Energy Commission Pacific Gas and Electric Co. New York State Energy Research and Development Authority DOE Federal Energy Management Program

Today’s outline Overview of past and present research Energy benchmarking and best practices Power supplies in IT equipment Efficient UPS systems Demonstrations Q & A

Completed activities OVERVIEW Data center case studies and benchmarking Research roadmap for CA CA market assessment

OVERVIEW Prior work in New York Case studies/energy benchmarking Workshops

OVERVIEW Related prior activities Jon Koomey study of impact of the Internet Jennifer Jackson-Mitchell thesis/case study Case studies/energy benchmarking Studies of standby losses and power supplies

OVERVIEW Current activities Benchmarking and best practices identification Self-benchmarking protocol Investigate uninterruptible power supplies (UPS) Investigate power supplies in IT equipment Collaborate on building interface developments

–NYSERDA sponsored project Air management – modeling and demonstration with SUNY, GA TECH, and IBM –CEETherm University of Maryland/Georgia Tech Related activities OVERVIEW

6-10 data centers – (still seeking sites) Self-benchmarking protocol Review all benchmark results to determine better performing systems Best Practices Add benchmarks for standby generation Investigate other performance metrics Energy benchmarking Benchmarking

local distribution lines to the building, 480 V HVAC system lights, office space, etc. UPSPDUcomputer racks backup diesel generators Energy end use in data centers computer equipment uninterruptible load UPS = Uninterruptible Power Supply PDU = Power Distribution Unit;

“In God we trust – all others bring data” Quote: Lee Eng-Lock

Power consumption in data centers Benchmarking

Benchmarks of IT equipment load density Benchmarking

Projections if fully loaded Benchmarking

Distribution of computer room power reported to uptime institute Benchmarking

HVAC effectiveness Benchmarking

Benchmarks of chillers Benchmarking 7.5 average

Benchmarking UPS efficiency

Inverter InOut Bypass Battery/Charger Rectifier Internal Drive External Drive I/O Memory Controller  Processor SDRAM Graphics Controller DC/DC AC/DC DC/DC AC/DC Multi output PS Voltage Regulator Modules 5V 12V 3.3V 12V 1.5/2. 5V 1.1V- 1.85V 3.3V 12V PWM/PFC Switcher Unregulated DC To Multi Output Regulated DC Voltages How many times are we converting electricity? Typical existing data center configuration

Measure performance of various systems at several load factors Investigate effects of different redundancy configurations Develop energy efficiency spec for UPS systems Scoping study for data center DC architecture Investigating efficiency opportunity for UPS systems UPS Systems

Status of UPS investigation Protocols developed for field or shop measurement. Mfgs specifications reviewed for efficiency versus load for static and inertial UPS topology. Calculation tools developed: For comparing AC versus DC powering at rack level For evaluating cost savings due to higher efficiency UPS. Completed testing of UPS to show impact of “high efficiency” option on static UPS Coordinating with International labeling effort for power quality & efficiency UPS Systems

Measured efficiency vs. load Sample of 12 field measurements, including ten from LBNL roadmap activity UPS Systems

Potential savings UPS Systems Preliminary macro and rack level energy savings estimate for improving UPS efficiency.

Delta Conversion Double Conversion Delta conversion UPS efficiency manufacturers data Courtesy: American Power Conversion (APC)

Operational/installation/space considerations also have a role in designing the UPS configuration. If actual load is 50% of design load, each UPS is loaded 25% If actual load is 50% of design load, each UPS is loaded 33% Design Load = 600kW 600kW 300kW UPS configuration and impact on loading

Document efficiency of existing power supplies Measure performance to determine real life efficiency Recommend efficiency performance thresholds Work with Server System Infrastructure (SSI) group to advance better performance Investigating power supplies commonly used in IT equipment Energy Efficient Power Supplies

Electricity use in a server Based on a typical dual processor 450W 2U Server; Approximately 160W out of 450W (35%) are losses in the power conversion process (Source: Brian Griffith: INTEL) Energy Efficient Power Supplies

Recommending more efficient power supplies Existing Efficiency Recommendation in SSI PS Design Guides The Server System Infrastructure (SSI) Initiative’s goal is to deliver a set of specifications covering two primary server elements: power supplies and electronics bays. Members of SSI are Intel, Dell, HP, Silicon Graphics, IBM. Energy Efficient Power Supplies

Full Load Efficiency > 68% Redundant System of Power Supplies for Servers Energy Efficient Power Supplies

Testing power supplies

Percent Loading Factory Spec Test Results 100%94%89.6%* 85%N/A89.4% 50%86.5% Real life efficiency Based on EPRI PEAC Testing of a 20kVA, 3-Ph Double Conversion UPS Energy Efficient Power Supplies

Importance of a flat power supply efficiency curve Energy Efficient Power Supplies

Redundant Power Supply (300W + 300W) At 50% Design Load each supply is loaded 25% 1200 W 4+1 (N+1) Redundant Power Supply System At 50% design load each supply is loaded 40% Power supply system redundancy can be accomplished without using “redundant power supplies”. Power supply redundancy Energy Efficient Power Supplies

Courtesy: American Power Conversion (APC) 80% of the time the processor usage was less than 4% of its peak capability A GHz processor is using MHz resource most of the time

Looking for production metrics Very Low Processor Activity does not relate to very low power consumption Most of the time the GHz processor is doing activities that can be done by a MHz processor but the input power consumption does not change much

CA public utilities’ emerging technology program and the CA Energy Commission are planning demonstration projects. Possibilities: –Air management –Air flow visualization –Alternative cooling strategies –UPS upgrades and reconfigurations –Rack level DC distribution –On site power generation –Ideas? Demonstration projects

Technology Transfer LBNL data center websites

Thank you Questions?