CheckMeter 2.1 Portable Working Standard Page 1 March 2009.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
Static Transfer Switch
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.

Multi Functional Digital Fault Recorder
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
LP33 Series UPS kVA 400Vac/CE
MTE´s Portable Product Portfolio
UR24 Process Refractometer
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
© ABB ABB DELTAsingle Commercial and technical presentation.
© ABB ABB ODINsingle Commercial and technical presentation.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
in the Age of the Photovoltaic
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
MIG II DIGITAL FEEDER PROTECTION
CALPORT 300 Three-Phase Portable Reference Standard
Common Equipment 2 : DC power Supply Common Equipment 2 : DC power Supply ---MODEL LPS-305 Motech.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
/1 Testing Harmonics and Flicker /1 Harmonics & Flicker Two different test standards: EN & EN EN controls.
Janus Convertible Line – interactive Series UPS
PPS 3.3 C Portable Power Source Page 1 January 2011.
POWER PLANT USED IN TELECOM
Portable Working Standard and Power Quality Analyzer
ABEM Terrameter LS Field-proven Imaging system measuring Resistivity, time-domain IP and SP.
MarsⅡ On-Line UPS Series
Distributor URL here  TDS2000 and TDS1000 Series Digital Storage Oscilloscopes Colorful Performance at a Black and White Price Power and precision: with.
17.March Connection to the CERN Power System of the TT2 mercury target project by Karsten KAHLE (TS-EL)
ENERGY of 21 st Century Independent Power Supplies.
Single Loop Analogue addressable fire control Panel
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
SFT 2841 IN CONNECTED MODE Prepare setting files.
Electrical Distribution Systems
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Power Probe The PSP Power Probe is a three phase data logger, quality of supply monitor, and remote terminal unit for demand-side- management. Historical.
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
PTS 2.3 C Portable Test System Page 1 March 2009.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Wiring standards Single phase, 2-wire 120V or 220V Single phase, 3-wire 220V between phases ; 110V between phase-neutral.
ISA CIRCUIT BREAKERS TEST SETS
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh 1, In Ho Ryu 2 and Jeong-Chay Jeon 3 * 1 Department.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
The Quality Control Company Quanti TM product series “Simplicity is the ultimate sophistication” - Leonardo da Vinci.
TRANSMISSION LINE MULTIPLE FAULT DETECTION AND INDICATION TO EB
DIGITAL MULTIMETER DMG
Technical Specification
Meco A Milli-Ohm Meter with Software
Model /21 Clamp on Power HiTESTER
System Network Structure
New EM210_AV.
Portable Working Standard
PTS 3.3 C Portable Test System.
Content * Overview * Project overall * PF meter * Calculation of firing angle * Generation of firing angle * Results * Comparison * Problems.
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh1, In Ho Ryu2 and Jeong-Chay Jeon3* 1Department.
HD SIGNAL CONDITIONER SERIES
DCM305E Earth Leakage Clamp Meter
PowerLogic™ offer for the basic metering market
PM9, PM9P and PM9C Power Meter
Presentation transcript:

CheckMeter 2.1 Portable Working Standard Page 1 March 2009

CheckMeter 2.1 integrates today’s requirements of a Portable Working Standard for testing electricity meters and meter installations: Applications  Size & Dimensions  rigid design  light in weight  Accuracy  Class 0.2%  Functions  Meter testing  1-phase measurement  Current measurement  Voltage measurement  Energy measurement  Documentation  Data memory  Transfer to Windows © Software CALSOFT I Page 2 March 2009

Advantages  Precision test equipment for AC values in the 45 Hz to 66 Hz frequency range  LCD display ¼ VGA (240 x 320 Pixels) with graphical user interface  Wide measuring range with auto ranging  Display of vector diagram for analysis of mains conditions and meter connections  Measurements of wave forms and harmonics with display  Easy detection of circuit connection faults  Data memory for test results and customer data  Small dimensions and light in weight  Serial interface (RS 232) for data transfer Page 3 March 2009

Functions  Active, reactive and apparent energy measurement with integrated error calculator  Impulse output for energy (galvanic isolation)  Registration of active, reactive and apparent energy for register testing  Active, reactive and apparent power measurements  Current and voltage measurements  Phase angle measurement  Power factor measurement  Frequency measurement Page 4 March 2009

Technical data Basic Characteristics  V Auxiliary supply from measurement circuit  Clamp-on CT 10 mA A  Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement  Accuracy  0.2 % Options:  CALSOFT I Software Page 5 March 2009

Connections Top and bottom view CheckMeter 2.1 [1]Phase connection [2]Neutral connection N [3]Connection for CT [4]Pulse input / output [5]Supply voltage connection [6]RS 232 serial line interface Page 6 March 2009

Connections Front view CheckMeter 2.1 [7]LCD display [8]Menu card keys [9]Cursor keys [10]Enter key [11]Start/Stop Impulses [12]Alphanumeric keypad Page 7 March 2009

Current clamps to the CheckMeter 2.1  Error compensated clamp-on CT for measurements in the range 10 mA … 120 A, cable diameter max. 10 mm  Clamp-on CT for measurements in the range 10 mA … 120 A, cable diameter max. 52 mm Page 8 March 2009

Operation Concept SymbolsDisplayControl Keys  Page 9 March 2009

Operation Concept Status Indication Page 10 March 2009

Operation Concept Main Menu Meter Testing  Measurement of load values  Vector diagram  Energy measurement  Basic settings  Page 11 March 2009

Operation Concept Meter Testing Page 12 March 2009

Operation Concept Measurement of Load Values Page 13 March 2009

Operation Concept Harmonics Analysis, Waveform Display, Vector Diagram Page 14 March 2009

Operation Concept Energy Measurement Page 15 March 2009

Operation Concept Administrative data set (ADS) Page 16 March 2009

Operation Concept Examples of test results Page 17 March 2009

Connection example Testing of a direct connected meter up to 100 A Page 18 March 2009

Connection example Testing of transformer operated meter Page 19 March 2009

Windows © -Software CALSOFT Selection of real time readout or readout of sets of data from memory of CheckMeter 2.1 Page 20 March 2009