HDL KNX System Introduction

Slides:



Advertisements
Similar presentations
Linking A quick overview of how to configure PulseWorx UPB devices to control each other.
Advertisements

EndNote. What is EndNote:  EndNote is referencing software that enables you to create a database of references from your readings. Your database of references.
Software setup with PL7 and Sycon V2.8
HAI Lighting Control Options UPB Technology Presentation Advance Information January, 2004.
Modbus Slave & Modbus Master in S7
DriveAP 1.2 & 2.1 DriveWare®.
Show Controller——DMX Module 48 Channel——SB-DN-48DMX 512 Channel——SB-DN-512DMX Configuration of Show Control ler ( DMX Module ) 240 Channel——SB-DN-240DMX.
Hytera Patrol System Tutorial
Geo CE-XM ch 4 Edited 10/14/05 1 The XM is the newest of the rovers, and unlike other units, it comes with software installed on the unit as well as using.
VistA Imaging Capture via Scanning. October VistA Imaging Capture via Scanning The information in this documentation includes only new and updated.
DLP LCD PANEL Programming
An Introduction to Designing and Executing Workflows with Taverna Aleksandra Pawlik materials by: Katy Wolstencroft University of Manchester.
Programming Software and Setting. if forget the IP address of SB-DN-1IP, programmer can press the reset button till the led goes red, then it is reset.
EndNote. What is EndNote? EndNote is referencing software that enables you to create a database of references from your readings.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
Dimmer debugging Big dimmer ( hanging dimmer ) ◆ 12ch 10A professional Intelligent Dimmer ◆ 6ch 20A professional Intelligent Dimmer ◆ 6ch 10A professional.
SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. Addressing button HDL -BUS.
Touch screen function manual Right & left scroll key Room selecting key, Maximal quantity 50. Controlling Target icon Room background image brightness.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
Chapter 3 Device Monitor Screen Otasuke GP-EX! Chapter 3 Device Monitor Screen Chapter 3 Device Monitor Screen.
Hotel Room Intelligent System applications SMART-HDL.
Quick guide to ASIMON configuration For version 3.0 or greater SAFETY AT WORK Date: 3/18/2009.
HDL-Bus International Technical Training Mr. Zeng Last revision: Aug 28, 2013.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the CON-DVT-IOE. Intellect 1.5 is used for the software portion. NEXT.
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the DVT CON-IOE. Intellect 1.0 is used for the software portion.
Buspro Wireless Last update: April 10, HDL-MCIP-RF.10 Connections: Buspro, Ethernet, Buspro wireless Work Mode: Mesh mode or Bridge mode Wireless.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Programming Software and Setting. Default IP Add : , also can be changed via Programming Software, if forget IP address, Programmer can.
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
STEINEL ACADEMY 1 Welcome to the Steinel Academy.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
目录 SB-CMS-8in1 Features ● 1 PIR motion sensor ● 1 Lux sensor ● 2 Dry contact inputs ● 2 external condition inputs ● IR(infrared) receiver ● IR(infrared)
Multi-Programmer User Guide 1. Contents 1.Product ComponentsProduct Components 2.Software InstallationSoftware Installation 3.Software UseSoftware Use.
KNX Push-button Pro Confidential Property of Schneider Electric |
Air-Condition controller
DIN Rail Music Player HDL-MZDN.432A.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
DALI-Gateway DG/S 1.1.
DALI Scene Controller HDL-MC-DALI.431.
DALI Scene Controller HDL-MC-DALI.431.
Wireless Power Interface
ETS Inside Product Launch
Multifunctional Sensor
ILife App.
FCU Controller M/FCU
DALI-Gateway DG/S 8.1.
Downloading Arduino FOR WINDOWS.
Dimmer 6fold 10V Actuator M/DA
Wireless Relay HDL-MPR01-RF.18.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Universal Interface, 4-fold, FM, US/U 4.2
DMX Controller SB-DN-48DMX.
Haiwell PLC Modules Introduce
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
DMX512 Gateway M/DMX512.1.
Wireless 3 Buttons Touch Panel
MOSFET Dimmer Actuator
Wireless Relay HDL-MPR02-RF.18.
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Siemens Step 7 Project with Controllere in 7 Steps: Step 1
IQCare Tab Mapping Tool
EndNote by: fatimah alotaibi.
Universal I/O Concentrator UK/S 32.2
ABB i-bus® EIB / KNX EIB Monitoring Unit EUB/S 1.1
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Presentation transcript:

HDL KNX System Introduction

KNX Introduction KNX- International standard of Home and Building Automation KNX organization Founded in 1999, head office - Brussels, Belgium Member companies : ABB, Siemens, Schneider, HDL..., more than 200 producers Organization website http://www.knx.org

KNX BUS EIB = European Installation Bus KNX = EIB + BatiBUS + EHSA KNX transmission media: Twist Pair – EIB:the most widely used Power Line - Batibus Radio Frequency - EHSA IP/Ethernet

KNX System Structure - Line 1.1.1 1.1.63 A line can have 64 devices The Max. length of one line is 1000 meters The Max. length of two devices on the same line is 700 meters The Max. length between the power supply and a device is 350 meters

KNX System Structure - Area Main line 1.0 Line 1 Line 15 LC1 LC15 1.15.1 1.15.63 1.1.1 1.1.63 1.1.0 1.15.0 Area An area can have 15 lines Every line is connected to main line via a line coupler The main line needs a separate power supply module

KNX System Structure A system can have 15 areas 3 4 5 6 7 8 9 10 11 12 13 14 15 Area line 0.0 Main line 1.0 Linie 1 Linie 15 LC1 LC15 1.15.1 1.15.63 2 1.1.1 1.1.63 1.1.0 1.15.0 Area 1 BC1 1.0.0 A system can have 15 areas A system can have as many as 14400 devices(15*15*64)

PA – Physical Address LC1 LC15 Area15 Area1 Physical Address indicates the physical location the device locates in, assign an unique physical ID to every device by ETS according to the device’s physical installation position. Line 1 LC1 DVC1 DVC63 LC15 Line15 Area15 Area1 1.0.0 15.0.0 1.15.0 1.1.0 1.1.1 1.15.1 1.1.63 1.15.63 1. PA format: A(area).B(line).C(device) A=0-15, B=0-15, C=0-255 2. The same area, the same A 3. The same line, the same B

Line Coupler/Repeater LC1 DVC1 DVC63 LC2 1.2.0 1.1.0 1.1.1 1.1.63 LC15 1.15.0 LR1 1.1.64 1.1.65 1.1.127 LR2 1.1.128 1.1.129 1.1.191 LR3 1.1.192 1.1.193 1.1.255 Main line Area1 M/LCR.1 Line Coupler: area、line isolation Line Repeater: line devices extension (one line can connect up to 3 repeaters in parallel)

Target/Control Object Object can send or receive telegram Every object has fixed control type(DPT: Data Point Type), e.g. on/off, relative dimming, etc. Every object has fixed data type and length. 220V A B Dimmer Object1:on/off 1bit Object2:relative dimming 4bit Object3:absolute dimming 8bit

GA – Group Address Group Address is a link, to achieve the control function. With same group address, the objects can communicate with each other, e.g., if you want to use button A to control relay channel C, then you need to assign a GA to both of them. 1. GA format: X/Y/Z Main group/middle group/sub-group X=0-15, Y=0-7, Z=1-255 2. Group address 0/0/0 is reserved for broadcast 3. One object can link with more than one group addresses 4. Different objects can link with same group address

GA – Group Address Main line Line 1 LC1 LC2 A S Line 2 Pushbutton 1 Lamp 1 1/1/2 A 1/1/1 S 1.1.1 1.1.2 1. 2.1 1. 2. 2 Movement detector Lamp 2 Line 2

ETS - Introdunction ETS is a configuration tool software made by KNX organization, the newest version is ETS5, however ETS3.0f is still widely used. When purchase a KNX product from a company, you will also receive a database of the product, you can then import the product database to ETS software and configure it, and finally upload your configuration to the product.

ETS - Create Database name your new project database double click click ‘new’ to create your project database click the icon in the manu bar to add project, click 'OK' then it will dispaly the windows for this project

ETS - Import Database Steps: manu bar->file->import->select database ->import the selected one or import all

ETS - Add Device Steps: new line->add device->find-> select the imported database->insert

Tips for Database Version Please check the production version from the module label, and use the corresponding database. For MOSFET Dimmer, production version V1.0 & V1.1---database V1.1; production version V1.2---database V1.2 For other devices: production version V1.0---database V1.0; production version V1.1---database V1.1; production version V1.2---database V1.2. 2017/4/26

ETS - Physical Address double click change physical address

ETS - Group Address 1- select the object 2- right-click to select 'link with...' option 3- assign group address for it: create new group address link with existing group address

ETS - Build Communication

Example - DLP + Dimmer Create a project and name it as 'Dimming', add one DLP(M/DLP04.1 ) database and one 4CH MOS Dimmer(M/D04.1) database in area1, line1. The M/DLP04.1 default physical address is 1.1.1, the M/D04.1's is 1.1.2. The default enabled object function of the DLP is switching(on/off) and the dimmer's is channel output(on/off) & relative dimming

Example - DLP + Dimmer Right-click the M/D04.1, select 'edit parameters' to enter the configuration page, enable the 1 bit response function for each channel.

Example - DLP + Dimmer Right-click channnel objects of dimmer, select 'link with...' to assign group addresses for them, here all group addresses are the new one, then select 'create new group address', set the address value then click 'OK'

Example - DLP + Dimmer Right-click the M/DLP04.1, select 'edit parameters' to enter the configuration page, select 'Dimming controller' work mode and 'Single button' operation mode for Rocker A & B

Example - DLP + Dimmer Right-click Rocker A&B objects of DLP, select 'link with...' to assign group addresses for them, here all group addresses need to be corresponding with the dimmer's, then select 'link with existing group address', set the address value then click 'OK'

Example - DLP + Dimmer 1- Right-click the M/DLP04.1, select 'Download...' 2- Select 'Program Address & Application' 3- Press the first and last buttons of DLP at the same time, it will enter the programming mode and its button LED will fresh 4- Start download

Example1 - DLP + Dimmer 1- Right-click the M/D04.1, select 'Download...' 2- Select 'Program Address & Application' 3- Press the 'PROG' button of dimmer, it will enter the programming mode and its LED will turn red 4- Start download

About Downloading Program Individual Address: Download physical address to device (need to press the PROG button to let it enter the programming mode) Download Application Program: Download configuration to device (if you know its physical address, just click this option to download the configuration directly) Program Address & Application: Download physical address and the configuration to device (if you donot know its physical address, click this option to download both of them, need to press the PROG button to let it enter the programming mode)

Combined Application 1 KNX bus fan coil unit DLP+FCU M/DLP04.1 M/FCU01.10.1 KNX bus HVAC can read temp from bus or local module. if read temp from local, must connect with the digital temp sensor. TS/C 1.0 digital temperature sensor

Combined Application 2 DLP+M/IRAC.1 Need to learn the IR codes and download them to IR emitter from HDL KNX Assistant Software HDL KNX Assistant Software

Combined Application 3 M/S04.1 + TTS/APR 1.0 1> dry contact input 2> temperature sensor input (TTS/APR 1.0, HDL type) 3> 0-10V ballast dimming output TTS/APR 1.0