Intensity measurements using TRIC Juan Carlos Allica On behalf of: M. Andersen, D. Belohrad, L. Jensen, F. Lenardon, A. Monera, L. Søby 1.

Slides:



Advertisements
Similar presentations
D. Wei, Y. Huang, B. Garlepp and J. Hein
Advertisements

The Industry’s Smallest 16 Bit ADC’s
A scalable DAQ system using the DRS4 sampling chip H.Friederich 1, G.Davatz 1, U.Hartmann 2, A.Howard 1, H.Meyer 1, D.Murer 1, S.Ritt 2, N.Schlumpf 2 1.
Test of LLRF at SPARC Marco Bellaveglia INFN – LNF Reporting for:
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
RF Synchronisation Issues
Yu. Artyukh, V. Bespal’ko, E. Boole, V. Vedin Institute of Electronics and Computer Science Riga, LATVIA 16th International Workshop on Laser.
BI SW for LINAC4 On behalf of BE/BI/SW BI software development process Specifications List of BI Systems – Not covered: PSB ring systems Conclusions Lars.
3/7/05A. Semenov Batch-by-Batch Intensity Monitor 1 Two-Channel Batch by Batch Intensity Monitor for Main Injector BBI.
TOF Electronics Qi An Fast Electronics Lab, USTC Sept. 16~17, 2002.
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
LLRF System for Pulsed Linacs (modeling, simulation, design and implementation) Hooman Hassanzadegan ESS, Beam Instrumentation Group 1.
The GANDALF Multi-Channel Time-to-Digital Converter (TDC)  GANDALF module  TDC concepts  TDC implementation in the FPGA  measurements.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
Feedback on Nanosecond Timescales (FONT) - Review of Feedback Prototype Tests at ATF(KEK) Glenn Christian John Adams Institute, Oxford for FONT collaboration.
Prototype Test of SPring-8 FADC Module Da-Shung Su Wen-Chen Chang 02/07/2002.
TDC and ADC Implemented Using FPGA
David Cussans, AIDA/CALICE DAQ Palaiseau, 10 Nov 2011 Trigger/Timing Logic Unit (TLU) for AIDA Beam-Test.
Booster Cogging Upgrades Craig Drennan, Kiyomi Seiya, Alex Waller.
K.C.RAVINDRAN,GRAPES-3 EXPERIMENT,OOTY 1 Development of fast electronics for the GRAPES-3 experiment at Ooty K.C. RAVINDRAN On Behalf of GRAPES-3 Collaboration.
Beam phase and intensity measurement Grzegorz Kasprowicz Richard Jacobsson.
1 FermiLab Recycler Ring BPM Upgrade Based on Digital Receiver Technology R. Webber, J. Crisp, P. Prieto, D. Voy, C. Breigel, C. McClure, M. Mengel, S.
Status of the Beam Phase and Intensity Monitor for LHCb Richard Jacobsson Zbigniew Guzik Federico Alessio TFC Team: Motivation Aims Overview of the board.
Micro-Research Finland Oy MRF Timing System Jukka Pietarinen Timing Workshop CERN February 2008.
The World Leader in High-Performance Signal Processing Solutions Design a Clock Distribution for a WCDMA Transceiver System CSNDSP 2006 Session: B.11 Systems.
Linac4 FBCT’s 18/ L4 BI BCT review Lars Søby On the behalf of: M. Andersen, D. Belohrad, L. Jensen, Franco Lenardon and J. C. Allica Santamaria.
The PITZ Timing System Frank Tonisch DESY - Zeuthen.
BI day 2011 T Bogey CERN BE/BI. Overview to the TTpos system Proposed technical solution Performance of the system Lab test Beam test Planning for 2012.
LLRF ILC GDE Meeting Feb.6,2007 Shin Michizono LLRF - Stability requirements and proposed llrf system - Typical rf perturbations - Achieved stability at.
HBD FEM Overall block diagram Individual building blocks Outlook ¼ detector build.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
BCT for protection LHC Machine Protection Review April 2005 David Belohrad, AB-BDI-PI
1 VeLo L1 Read Out Guido Haefeli VeLo Comprehensive Review 27/28 January 2003.
Digital Phase Control System for SSRF LINAC C.X. Yin, D.K. Liu, L.Y. Yu SINAP, China
Alexei SemenovGeneric Digitizer Generic Digitizer 10MHZ 16 bit 6U VME Board.
PSI - 11 Feb The Trigger System of the MEG Experiment Marco Grassi INFN - Pisa On behalf of D. Nicolò F. Morsani S. Galeotti.
1 DAQ Update MEG Review Meeting, Feb. 17 th 2010.
Charge Measurement Using Commercial Devices Jinyuan Wu, Zonghan Shi For CKM Collaboration. Jan
BI day /12/00 1 PIPOS Project (TT2 & TT10) (Beam performances) G. Vismara  Present situation  Proposals  Beam parameters  Technical solution.
Collimator BPM electronics – Results from the lab, SPS and LHC
Beam Line BPM Filter Module Nathan Eddy May 31, 2005.
Charge Measurement Using Commercial Devices Jinyuan Wu, Zonghan Shi For CKM Collaboration. Jan
Beam diagnostics developments at LAPP: Digital part CTF3 Collaboration Meeting Louis Bellier, Richard Hermel, Yannis Karyotakis, Jean Tassan,
L.Royer – Calice Manchester – Sept A 12-bit cyclic ADC dedicated to the VFE electronics of Si-W Ecal Laurent ROYER, Samuel MANEN LPC Clermont-Ferrand.
Mixed-Signal Option for the Teradyne Integra J750 Test System
1 MGPA Linearity Mark Raymond (Dec.2004) Non-linearity measurements in the lab hardware description method results.
VME64x Digital Acquisition Board (TRIUMF-DAB) Designed to handle 2 channels of 12-bit 40MHz Data Will be used for both the LTI & LHC beam position system.
SKIROC ADC measurements and cyclic ADC LPC Clermont-Ferrand Laurent ROYER, Samuel MANEN Calice/Eudet electronic meeting Orsay June.
S. Bota – Calorimeter Electronics overview - July 2002 Status of SPD electronics Very Front End Review of ASIC runs What’s new: RUN 4 and 5 Next Actions.
FBCT experience at Desy Presenter: Matthias Werner, DESY At CERN Workshop: „Improving the accuracy of the BCT measurements in the LHC“ January 2011.
2/June/2009LHCb Upgrade1 Single ended ADC Differential ADC –Convert single ended signal to differential (use AD8138 amp) –ASIC differential output ADC.
Mitglied der Helmholtz-Gemeinschaft Hardware characterization of ADC based DAQ-System for PANDA STT A. Erven, L. Jokhovets, P.Kulessa, H.Ohm,
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
Digitization at Feed Through R&D (2) Digitizer Performance Evaluation Student: John Odeghe ; SC State, Fermi Lab Intern Supervisor: JinYuan Wu; Fermi Lab.
MADEIRA Valencia report V. Stankova, C. Lacasta, V. Linhart Ljubljana meeting February 2009.
TDC and ADC Implemented Using FPGA
Front-end Electronic for a neutrino telescope : a new ASIC SCOTT
Jinfan Chang Experimental Physics Center , IHEP Feb 18 , 2011
AHCAL Beam Interface (BIF)
BI-day 2014, The SEM-grid renovation project Michel Duraffourg
Alternative FEE electronics for FIT.
96-channel, 10-bit, 20 MSPS ADC board with Gb Ethernet optical output
Status of the Beam Phase and Intensity Monitor for LHCb
BCTW calibration status and future
FPGA implementation of a multi-channels, 1 ns time resolution, multi-hit TDC Lorenzo Iafolla Lorenzo Iafolla SuperB Workshop.
A Software Defined Radio for the Masses, Part 4
Low Level RF Status Outline LLRF controls system overview
BESIII EMC electronics
FPGA Based Trigger System for the Klystron Department
Low Level RF Status Outline LLRF controls system overview
Presentation transcript:

Intensity measurements using TRIC Juan Carlos Allica On behalf of: M. Andersen, D. Belohrad, L. Jensen, F. Lenardon, A. Monera, L. Søby 1

What is TRIC (TRansformer Integrator Card)? – TRIC is a VME64x 6U standard card used to measure beam intensity coming from FBCTs (Fast Beam Current Transformers) in the PS complex. – It integrates signals coming from an FBCT using its calibrator as a reference. – Calibration can be either on-line (charges, current) or off-line. – It offers different integration modes (bunch to bunch, total intensity) with offset suppression. – It is remotely managed by software, a FESA class (internal analyzer). Introduction 2

Why TRIC? Automated calibration Remote setup Maintainability Fast upgrade, FPGA remote programming Introduction 3

4 Hardware CPLD ADC 212MHz FPGA µController DAC ADC DC-DC 10V TO 200v CALIBRATIO N VME PLL CLK Analog Inputs Calibration Outputs Trigger, Inputs and Outputs TRIC 4 TRIC 3.X

Calibration Concept 5 Q = C x V => x (Beam integra – Offset integra) (Beam integral – Offset integral) N charges calibration x (Cal integral – Offset integral) N charges Beam = Sampling = 5 ns maxMeasured Signal 212 MHz ADC Calibrator Gate Calibrator Offset Gate Beam GateBeam Offset Gate Measurement principle e N charges Cal = C x V

Measurement process 6 VME BUS TRIC PSB-CPS Timing t t t t t Trigger Calibrator out Signal 1 Beam and Offset Meas Gate Cal and Offset Meas Gate (Beam integral – Offset integral) N charges calibration x (Cal integral – Cal Offset integral) N charges Beam = EXPERT GUI SOFTWARE 3And PSB-CPS trigger 1. Settings from Expert GUI 3. Beam signal to TRIC 4. Cal signal to FBCT 5. Cal signal to TRIC 6. Intensity calculation FBCT Signal 1 Calibrator

7 Expert GUI Beam Beam offset Calibration by Charges Cal. offset

Cal factors improve the measurement precision Are calculated by averaging on-line intensity measurements Cal factors for 0dB, 14dB and 28dB attenuation in order to maximize the dynamic range 8 Expert GUI Cal Factors Measured in Booster and Isolde

9 Cross calibration In order to improve the relative precision between the FBCTs we have cross calibrated the TRICs reducing the relative error between them to just TRIC measurement standard deviation (0.25 %) [1], for more info [2]. - The cross calibration procedure starts by sending 1024 calibration pulses from a reference TRIC to the analog inputs of the TRIC been cross-calibrated. - The measurement results are then averaged in each channel and later on averaged with all the other TRICs. The result of the averaging is the number of charges sent by the reference TRIC but with a lower uncertainty. This value is used to calibrate the other TRICs and to reduce the total uncertainty. [1] Lab Measurement with the TRIC ref’s pulse as input [2] DIPAC 2011, Upgrade of the PCB/CPS Fast Intensity Measurements

10 Cross calibration 1024 measurements for each card

11 Cross calibration set up This set up is repeated for all the TRICs resulting in a calibration constant that gives us the deviation for each TRIC in respect to the TRICs’ average. 1.Process starts with a C program “testric”. 2.TRIC ref sends a calibration pulse which simulates the beam. 3.Signal is received on the TRIC DUT for both channels. 4.TRIC Under Test sends its calibration pulse. 5.Sends measurement results via VME. 6.The program “testric” saves the data and repeats the process 1024 times to have the average value of the measurement; all the data is stored in one file.

12 Measurements with a calibration constant Under Test Operative DCCT User : CNGS :00: To :48:13.900

FBCT-DCCT transfer function without Cal constant FBCT-DCCT transfer function after Cal constant F16.BCT: difference between non cross-cal and cross-cal is 1% when comparing with DCCT. User : CNGS :00: To :48: Measurements with a calibration constant

14 TRIC deployment Under Test Operative 04/11/2011

15 TRIC deployment FCBTDate PS to AD:TRA TRA AD:TFA DE.TFA LINAC3ITL.TRA ITF.TRA ITF.TRA ITH.MTR LEIRETL.MTR ETL.MTR EI.MTR ER.MTRF L4 3MeVL4L.BCT CHOPPER L4L.BCT CHOPPER L4L.BCT.2012 ML L4L.BCT.2012 ML Trafos (IWD)BuildingAreaCal ConstantOn-line Cal ADE.BCTFPS193AD NO BT.BCT.00361Booster Yes BTM.BCT.00361Booster NO BTP.BCT.00361Booster Yes BTY.BCT ISOLDE +IWD Yes BTY.BCT ISOLDE +IWD NO BTY.BCT ISOLDE +IWD Yes EE.BCT10363LEIRto updateyes ETP.BCT10363LEIR Yes F16.BCT126359TT Yes F16.BCT203269TT NO F16.BCT212269TT2to updateNO F16.BCT372269TT Yes F16.BCT386269TT2to updateYes F61.BCT02157EastA yes FTS.BCT379269TT Yes TRICs currently installed Outlook

Introduce certain hardware modifications to reduce the thermal and electromagnetic noise (new DC-DC converter in new version TRIC 4). Replace the old FBCTs (some are more than 30 years old) in order to have a standard set TRIC + FBCT for the intensity measurements. 16 Outlook

TRIC has become the new standard for the beam intensity measurement in the PS complex. TRIC 4 prototype manufacturing and 30 boards buch intended for 1 st Q units currently installed in total, 30 units expected to be installed for LINAC3, LINAC4, AD and LEIR. 17 Conclusions

Thank You, Questions ?? 18

19 ADC Analog Devices AD9430 Resolution Q = FSR/N => 1.5/2^10.6 Q = µV Differential Non Linearity Integral Non Linearity Phase Jitter: 12kHz~80MHz 0.5ps typ., 1ps RMS max Model CCPD-034 is a MHz to MHz LVPECL Clock Oscillator

20 TRIC Specs

21 Cross correlation FBCT Before Cal constant F16.BCT.126:TOTAL_Cal_CteF16.BCT.372:TOTAL_Cal_cteFTS.BCT.379:TOTAL_Cal_ctePR.DCBEFEJE_1:INTENSITY F16.BCT.126:TOTAL_Cal_Cte 1 F16.BCT.372:TOTAL_Cal_cte FTS.BCT.379:TOTAL_Cal_cte PR.DCBEFEJE_1:INTENSITY