PID Detector Requirements for Emittance Measurement Chris Rogers, MICE PID Review, Thursday Oct 12.

Slides:



Advertisements
Similar presentations
1 MICE Beamline: Plans for initial commissioning. Kevin Tilley, 16 th November. - 75days until commissioning Target, detectors, particle production Upstream.
Advertisements

HARP Anselmo Cervera Villanueva University of Geneva (Switzerland) K2K Neutrino CH Meeting Neuchâtel, June 21-22, 2004.
1 Acceptance & Scraping Chris Rogers Analysis PC
PID Detector Size & Acceptance Chris Rogers Analysis PC
1 Simulation Status/Plans Malcolm Ellis Sci Fi Tracker Meeting Imperial College, 10 th September 2004.
1 Progress report on Calorimeter design comparison simulations MICE detector phone conference Rikard Sandström.
Emittance definition and MICE staging U. Bravar Univ. of Oxford 1 Apr Topics: a) Figure of merit for MICE b) Performance of MICE stages.
FIGURE OF MERIT FOR MUON IONIZATION COOLING Ulisse Bravar University of Oxford 28 July 2004.
1 Angular Momentum from diffuser Beam picks up kinetic angular momentum (L kin ) when it sits in a field –Canonical angular momentum (L can ) is conserved.
MICE the Muon Ionization Cooling Experiment Emilio Radicioni, INFN EPS-HEP Aachen 2003.
Particle by Particle Emittance Measurement to High Precision Chris Rogers Imperial College/RAL 17th March 2005.
1 EMCal & PID Rikard Sandström Universite de Geneve MICE collaboration meeting 26/6-05.
1 Emittance Calculation Progress and Plans Chris Rogers MICE CM 24 September 2005.
1 PID, emittance and cooling measurement Rikard Sandström University of Geneva MICE Analysis phone conference.
International Muon Ionization Cooling Experiment Edward McKigney Imperial College RAL March 25, 2002 Physics Motivation and Cooling Introduction.
Changing the absorbers: how does it fit in the MICE experimental programme? Besides the requirement that the amount of multiple scattering material be.
1 Downstream PID update Rikard Sandström PID phone conference
1 Downstream scraping and detector sizes Rikard Sandström University of Geneva MICE collaboration meeting CERN.
1 PID Detectors & Emittance Resolution Chris Rogers Rutherford Appleton Laboratory MICE CM17.
1 G4MICE studies of PID transverse acceptance MICE video conference Rikard Sandström.
1 Chris Rogers Imperial College 18 May 2006 TOF II Justification.
PID Detector Size & Acceptance Chris Rogers Analysis PC
M.apollonioCM17 -CERN- (22/2 - 25/2 2007)1 Single Particle Amplitude M. Apollonio – University of Oxford.
A Few Words on Emittance Chris Rogers MICE vc 27/05/05.
1 G4MICE downstream distributions G4MICE plans Rikard Sandström Universite de Geneve MICE collaboration meeting 27/6-05.
1 Statistics Toy Monte Carlo David Forrest University of Glasgow.
K.Walaron Fermilab, Batavia, Chicago 12/6/ Simulation and performance of beamline K.Walaron T.J. Roberts.
Chris Rogers, MICE CM16 Wednesday Plenary Progress in Cooling Channel Simulation.
Beam line characterization with the TOFs1 Demonstrating the emittance-momentum matrix Mark Rayner, CM26 California, 24 March Initial.
Simulated real beam into simulated MICE1 Mark Rayner CM26.
Emittance Calculation Chris Rogers, Imperial College/RAL Septemebr
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
1 Downstream PID update - How cooling section affects TOF measurement Rikard Sandström PID phone conference
1 Emittance Calculation Progress and Plans Chris Rogers Analysis PC 18 August 2005.
1 PID Detector Size & Acceptance Chris Rogers Analysis PC
TOF Resolution Required to measure bunch length ~ 0.5 ns RMS from RF Bucket size For 1e-3 emittance measurement resolution of TOF should be
Mark Rayner, Analysis workshop 4 September ‘08: Use of TOFs for Beam measurement & RF phasing, slide 1 Use of TOFs for Beam measurement & RF phasing Analysis.
18 August 09Mark Rayner – Momentum measurement by The TOFs1 Momentum measurement by the TOFs A correction to an O(4 MeV/c) bias on the current muon momentum.
Chris Rogers, Analysis Parallel, MICE CM17 Progress in Cooling Channel Simulation.
1 Tracker Window & Diffuser Radius vs Scraping Aperture Chris Rogers Analysis PC 6th April 06.
M.apollonio/j.cobbMICE UK meeting- RAL - (9/1/2007) 1 Single Particle Amplitude M. Apollonio – University of Oxford.
1 EMCal design MICE collaboration meeting Fermilab Rikard Sandström.
Diffuser Studies Chris Rogers, IC/RAL MICE VC 09 March 2005.
Critical Issues for MICE Chris Rogers MICE CM 15.
Analysis of MICE Chris Rogers 1 Imperial College/RAL Thursday 28 October, With thanks to John Cobb.
Oct 15, 2003 Video Conference Energy Deposition Steve Kahn Page 1 Energy Deposition in MICE Absorbers and Coils Steve Kahn November 2, 2003.
Report on the Analysis Group & Plans V. Blackmore MICE VC 163 Thursday, 12 th December /11.
MICE pencil beam raster scan simulation study Andreas Jansson.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
Results from Step I of MICE D Adey 2013 International Workshop on Neutrino Factories, Super-beams and Beta- beams Working Group 3 – Accelerator Topics.
MICE input beam weighting Dr Chris Rogers Analysis PC 05/09/2007.
MICE at STFC-RAL The International Muon Ionization Cooling Experiment -- Design, engineer and build a section of cooling channel capable of giving the.
MICE: The International Muon Ionisation Cooling Experiment MOPLT106 Abstract The provision of intense stored muon beams would allow the properties of neutrinos.
Oct 15, 2003 Video Conference Energy Deposition Steve Kahn Page 1 Energy Deposition in MICE Absorbers and Coils Steve Kahn November 2, 2003.
1M. Ellis - NFMCC - 31st January 2007 MICE Analysis.
PID simulations Rikard Sandström University of Geneva MICE collaboration meeting RAL.
1 PID Detector Size & Acceptance Chris Rogers Analysis PC
A bin-free Extended Maximum Likelihood Fit + Feldman-Cousins error analysis Peter Litchfield  A bin free Extended Maximum Likelihood method of fitting.
26 Oct 2010PC Physics Requirements of Software from Chris R ~19 Oct. My.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Mark Rayner – Analysis SessionCM25, 4 November Beam characterization by the TOFs Mark Rayner The University of Oxford MICE CM25.
Learning Theory Reza Shadmehr Distribution of the ML estimates of model parameters Signal dependent noise models.
Monte Carlo simulation of the particle identification (PID) system of the Muon Ionization Cooling Experiment (MICE) Mice is mainly an accelerator physics.
MEASUREMENT OF EMITTANCE AND OTHER OPTICS QUANTITIES V. Blackmore 01/19.
Mark Rayner – Analysis SessionCM25, 4 November The TOF detectors: Beyond particle identification Mark Rayner The University of Oxford MICE CM25.
MICE S TEP IV P HYSICS ‘D ELIVERABLES ’ V. Blackmore MAP 2014 Spring Meeting 30 th May, /15 AKA “What will we learn from Step IV?”
Marco apollonioAnalysis Meeting (9/12/2006)1 transmission vs amplitude with a finite size diffuser M. Apollonio – University of Oxford.
MEASUREMENT OF EMITTANCE AND OTHER OPTICS QUANTITIES V. Blackmore MICE Optics Review 14 th January, /22.
Using MICE to verify simulation codes?
The Detector System of the MICE Experiment
Presentation transcript:

PID Detector Requirements for Emittance Measurement Chris Rogers, MICE PID Review, Thursday Oct 12

Overview Emittance definition & MICE aims Longitudinal and transverse phase space Trade-off between longitudinal heating and transverse cooling Emittance calculation method Longitudinal emittance measurement using TOF I PID Effects on longitudinal and transverse emittance Pi mis-ID Mu mis-ID e mis-ID But the effects of the PID Detectors on emittance has barely been studied The effort should come from the PID group Needs someone on it full time

Emittance Definition Reminder: emittance is defined according to the covariance matrix of the phase space variables Phase space vector U 6D =(t,E,x,p x,y,p y ) Transverse phase space vector U 4D =(x,p x,y,p y ) Longitudinal phase space vector U 2D =(t,E) To a good approximation longitudinal and transverse phase space are independent Then we want to measure at least the following quantities: Where V(U) is the determinant of a matrix with elements which is the covariance and

MICE Aims MICE decreases transverse emittance  4D And MICE increases longitudinal emittance  2D Energy straggling increase  (E) An accelerator has a maximum 2D and 4D emittance which it can accept If we are to show that MICE really cools, i.e. increases the number of muons we can fit into an accelerator, we need to measure both longitudinal emittance and transverse emittance This means we need to measure the time to calculate 6D emittance This is in the RAL proposal Time measurement is a responsibility of TOF1 and TOF2 i.e. the PID group

Emittance Calculation The baseline emittance calculation (upstream): 1. Particle passes through upstream detectors 2. Particle is identified 3. Throw away particles identified as background There may be a better way 4. Particles have some measured distribution in E,x,P x,y,P y and a ~ flat distribution in time (on scale of RF) 5. Particles are given a statistical weight to tweak the distribution from the beamline so that particles have a chosen distribution that corresponds to a known emittance E.g. give particles a gaussian distribution in momentum and position The distribution of measured variables should be chosen to be the “convolution” of the desired true distribution and the distribution of errors 6. (This set of particles is then measured downstream and the new, cooler emittance is calculated)

(1) Time measurement Measure time of each muon at the TOF Extrapolate the measured time at the TOF to the tracker using measured (x,y,p x,p y p z ) in the tracker Uncertainty due to presence of diffuser/materials stochastic processs ~ 40 ps RMS (+ ~25 ps mean time offset due to Multiple Scattering effects) Uncertainty due to tracker resolution ~ 25 ps RMS Uncertainty due to TOF resolution ~ 70 ps RMS Total uncertainty ~ 90 ps RMS for 70 ps TOF

(2) Deconvolution Beam RMS width is ~ 500 ps We want to measure this RMS to ~ 1% accuracy (5 ps) TOF resolution is ~70 ps IF the error on t is independent of the phase space variables If we know  2 (dt) to <10% then we can get the desired accuracy In practice this “deconvolution” will be more complicated But a careful calibration is crucial to perform the emittance calculation Calibration resolution is more important than the absolute resolution

Effect of mis-ID on emittance This timing measurement is probably as important/more important than the PID measurement But on to PID! Measured emittance is related to true emittance via: N meas meas =N true true +N bg bg - N mis mis Subscript “meas” is measured, subscript “true” is true, subscript “bg” is background identified as muons, subscript “mis” are muons identified as background A 2 is amplitude squared is “emittance” of a particle wrt beam ~ beam emittance (with some constant terms) We select our beam to have the distribution with meas The actual beam will be a distribution with true Fine… but really we want to know what will happen to the change in emittance…

Effect of mu mis-ID Muon mis-ID as something else If we lose muons upstream, this will not effect the emittance change at all The only effect is the damage to muon rate Don’t want to lose all muons in some region of phase space! E.g. if we lose a large number of muons with a particular momentum that are mis-ID’d by the Cerenkov then we may find trouble Require that the mis-ID of muons is not sufficient to reduce the phase space density by > 10 % in any region of phase space I.e. for any values of U 6D =(t,E,x,p x,y,p y )

Effect of pi/e mis-ID Pion mis-ID as muon Pions that are mis-identified will typically decay somewhere in the cooling channel to muons Many decay muons will be lost and we will see an excess of scraping/muon decay Other decay muons will typically have a higher transverse momentum than the incoming pions RMS distribution of the decay Any Multiple Scattering the pion sees in material This will look like beam heating With what significance? Needs quantitative study Electrons mis-ID as muon If electrons are mis-ID’d as muons upstream, we will see an excess of scraping/muon decay downstream Not a problem I think

Cooling measurement bias I hesitate to give even an estimate of the bias in the cooling measurement I will try but forgive me for my lack of physics Say that ~1/2 of muon decays from mis-ID’d pions are captured in the channel Say that the decay muons have ~double the single particle emittance of decayed pions Then use Emittance  = so that  =N bg /N true bg Then  = N bg /N true For  << 10e-3 require N bg /N true << 10e-3 BUT this needs a serious quantitative study

Conclusions The effects of the PID Detectors on emittance has barely been studied This is essential and the effort should come from the PID group Needs someone on it full time The PID group must sail their own ship For me the timing measurement is probably as important/more important than the PID measurement Calibration resolution is more important than the absolute resolution In general pi mis-ID is what we worry about Require ~10 -3 purity Require muon density is not heavily depleted in a particular region But it all needs a quantitative study There is no manpower on this effort We are close to running