Understanding residual limb volume loss - utilising a physical model (Manikin) Jia Lizhang 1, Kerry Coleman 2, Magnus Gislason 2, Lüder Mosler 3, and Arjan.

Slides:



Advertisements
Similar presentations
Introduction A challenge of single kernel testing using an instrument such as the Perten Single Kernel Characterisation System (SKCS) is to relate the.
Advertisements

Stephen Gaw, MS Georgia Tech MSPO April 23, 2008 Stiffness properties in the frontal plane of multiaxis prosthetic feet and the influence of shoes.
Aerospace Engineering Laboratory II
Statistics in Science  Statistical Analysis & Design in Research Structure in the Experimental Material PGRM 10.
Amanda Neves URI Biomedical Engineering.  Fit of the prosthesis is extremely important for the comfort of the limb and prevent skin irritation or pain.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
This article and any supplementary material should be cited as follows: Sanders JE, Severance MR, Swartzendruber DL, Allyn KJ, Ciol MA. Influence of prior.
Fluid structure interaction of left ventricle modelling from diastole to systole based on in-vivo CMR Hao Gao 1, Boyce E. Griffith 2, David Carrick 3,
The Effect of Transtibial Prosthesis Suspension on Residual Limb Pistoning Austin Balogh MSPO Research Presentation April 23, 2008.
L Exercise Training and Body Composition Training.
An Experimental Study and Fatigue Damage Model for Fretting Fatigue
Limiting fiber extensibility as parameter for damage in venous wall Lukas Horny, Rudolf Zitny, Hynek Chlup, Tomas Adamek and Michal Sara Faculty of Mechanical.
Conductivity Testing of Unsaturated Soils A Presentation to the Case Western Reserve University May 6, 2004 By Andrew G. Heydinger Department of Civil.
Impacts of Seismic Stress on Pore Water Pressure in Clayey Soil By: Qazi Umar Farooq Lecturer Civil Engineering Dept Univ of Engg & Tech Taxila.
No More Peg Legs and Hooks Better Prosthetic Design through Engineering.
An Experimental Investigation of Turbulent Boundary Layer Flow over Surface-Mounted Circular Cavities Jesse Dybenko Eric Savory Department of Mechanical.
Prediction of Load-Displacement Curve for Weld-Bonded Stainless Steel Using Finite Element Method Essam Al-Bahkali Jonny Herwan Department of Mechanical.
Two-Phase Heat Transfer Laboratory Texas A&M University Experimental Study of Condensation on Micro Grooved Plates R. Barron-jimenez, H. Y. Hu, G. P. Peterson.
CE 230-Engineering Fluid Mechanics Lecture # 4and5 Fluid properties (2)
The Advanced Prosthetic Hand Project Jessica Reddy, IMSURE Fellow Mentor: Dr. William C. Tang.
AE 495 Project Progress Report XX Presentation, Put Date Here Put Your Presentation Title Here Names of the students in your group Department of Aerospace.
Numeracy in Nursing. Copyright © ijc2003 Numeracy Overview Numeracy & Key skills Why numeracy is important Types of Nursing Calculations Problems with.
PROSTHESIS MUHAMMAD FARRUKH BASHIR FCPS(ORTHO) MUHAMMAD FARRUKH BASHIR FCPS(ORTHO)
Numeracy in Nursing. Copyright © ijc2003 Numeracy.
Durability Testing and Analysis at The University of Alabama The Structural Durability and Fatigue Performance Group was established by Dr. M. E. Barkey.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
And the effects of Diabetes.  62 y.o.  Black Male  5’7”  lbs  Poly-pharmacy  Multiple diagnosis including diabetes.
PHYSIOLOGICAL STRATEGIES.  Physiological strategies is the focus of two elements- the removal of metabolic by-products and a nutrition plan to replace.
Upper Limb Prosthetic Adaptation/Redesign Group 6 Cassie Edwards, Meg Stevenson, Amy Thomas, Meagan Williams Advisor: Dr. Mark Richter Aaron Fitzsimmons.
Introduction to Fluid Mechanics Engineering 1h Prof Bill Easson.
This article and any supplementary material should be cited as follows: Sanders JE, Severance MR, Allyn KJ. Computer-socket manufacturing error: How much.
This article and any supplementary material should be cited as follows: Juhnke D, Beck JP, Jeyapalina S, Aschoff HH. Fifteen years of experience with Integral-Leg-Prosthesis:
Hands Free Hydro Cast – Optimising Trans-femoral Socket Design and Maximising Rehabilitation Potential Buis AWP, McGarry A, Kamyab M, Murray KD, Hillman.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
This article and any supplementary material should be cited as follows: Komolafe O, Wood S, Caldwell R, Hansen A, Fatone S. Methods for characterization.
Improved Lower Limb Prosthesis
Towards a Biarticular Prosthesis: Model Development and Sensitivity Analysis of Clutched Spring Parameters Andrea Willson University of Washington VA Center.
Elevated Vacuum Suspension
Chapter 1 These notes are to be written in your composition book.
Part 1: Assessment for Prosthetic Use & Stump Management.
Title of the study. Principal investigator and co workers names Organization/College name.
Investigation of Thin Film Evaporation Limit in Single Screen Mesh Layers Presented to IMECE 2002 Nov. 19, 2002, New Orleans, LA Yaxiong Wang & G.P. “Bud”
School of Civil Engineering University of Nottingham Predicting the Repeated Load Behaviour of Pavement Subgrades Using the Three- surface Kinematic Hardening.
Z. Guo, R. De Vita A Probabilistic Constitutive Law For Damage in Ligaments Page 1 Z. Guo, R. De Vita A Probabilistic Constitutive Law For Damage in Ligaments.
BRACE & LIMB LABORATORY. Processes of making a Transtibial prosthesis.
Chapter 42 Lower Extremity Amputation
This article and any supplementary material should be cited as follows: Kahle JT, Highsmith MJ. Transfemoral sockets with vacuum-assisted suspension comparison.
Fuel Tank Tumbler Presented by: Jay LeiningerProject Manager Bryan EricksonFrame Design Lead Roberto GarciaAir Design Lead Andrew NiemannAcquisitions Officer.
Amputee’s Satisfaction with Two Different Transfemoral Suspension Systems and the Experienced Problems Hossein Gholizadeh 1,2, Noor Azuan Abu Osman 1,
F EASIBILITY C ASE S TUDY ON THE USE OF D YNAMIC E LASTOMERIC F ABRIC O RTHOSES IN CMT​ Sarah Brown ​ Paediatric Neuromuscular Physiotherapist ​ Royal.
This article and any supplementary material should be cited as follows: Major MJ, Johnson WB, Gard SA. Interrater reliability of mechanical tests for functional.
This article and any supplementary material should be cited as follows: Boone DA, Kobayashi T, Chou TG, Arabian AK, Coleman KL, Orendurff MS, Zhang M.
Prosthesis in Transtibial Amputation
Proctor’s Implementation Outcomes
Radiofrequency Ablation of Amputation Neuromas: A Small Case Series
Proximal Femoral Focal Deficiency Treatment:
Pre-clinical evaluation of novel socket materials
Prosthetic Socket Fit & Comfort Score
Results and Discussion
Implantable Endpad Mike
Trinity Amputation and Prosthesis Experience Scales Joanne Hebenton
LIGHTWEIGHT PROSTHETIC FOREARM: A Press-fit Design
÷ 5 = 29 How many 5s are there in 1? Great!
÷ 2 = 24 How many 2s are there in 4?
Regional differences in pain threshold and tolerance of the transtibial residual limb: Including the effects of age and interface material  Winson C.
Accessible incontinence control device
Micrositing for Wind Turbines
Design of Experiments An Introduction.
Philip Huang, MD, MPH Director/ Health Authority
Presentation transcript:

Understanding residual limb volume loss - utilising a physical model (Manikin) Jia Lizhang 1, Kerry Coleman 2, Magnus Gislason 2, Lüder Mosler 3, and Arjan Buis 1 1. NCPO, Department of Bioengineering, University of Strathclyde Glasgow, UK 2. Department of Mechanical and Aerospace Engineering, University of Strathclyde Glasgow, UK 3. Otto Bock HealthCare GmbH

Introduction - Hypothesis It is suggested that vacuum-assisted suspension systems retard limb volume reduction in part through improving fluid inflow into the residual limb so that it better balances with fluid outflow. This study investigated if it is it physically possible to manage volume changes in a controlled environment.

Introduction - Background Volume loss of the residual limb can; cause discomfort, pain, and loss of prosthetic fit; affect the delivery of shear stresses to the weight bearing structure ‘the skeleton’; affect suspension and the limb’s pistoning in the socket during ambulation; In addition, volume fluctuation varies greatly among individuals as a function of comorbidities, prosthesis fit, activity level, etc.

Methods A Physical Model of a Transtibial Residual Limb & Experimental Tests in Instron Right: The physical model tested in Instron Machine Left: The physical model structure

Results –

Results – -200N~35N 30 cycles experimental results 30 KPa 45 KPa 60 KPa

Results – -200N~35N one cycle FE Modelling (no vacuum) Left: one cycle displacement in one secondRight: FE modelling interface pressure distribution

Results – Comparison of experiments & FE modelling (no vacuum)

Results – -700N~35N 30 cycles experiments results

Discussion Limited evidence exists regarding the management of limb volume, and the evidence available focuses on adults with trans-tibial amputation. It is essential to understand what is physically happening under controlled conditions and this study is a first attempt to do so. Furthermore, the development of a Finite-Element model informed by empirical and clinical tests created a valuable understanding what is physiological possible and what not.

Conclusions Application of a vacuum to the socket/liner interface considerably reduces pistoning in the physical model Consistent displacement result was found on the physical model experimental tests and the FE model Reduction of volume loss could not be replicated in the physical model A clinical-significant-study is recommended.

Acknowledgements Ms Katika Samaneeien Dr Philip Riches Bioengineering University of Strathclyde Glasgow Mr Schönemeier Mark Otto Bock HealthCare GmbH