B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 1 Learning.

Slides:



Advertisements
Similar presentations
Supplementary Training Modules on Good Manufacturing Practices
Advertisements

Dr. Birgit Schmauser, BfArM, Bonn
Instrumental Analysis
Calibration methods Chemistry 243.
Estimation of TLD dose measurement uncertainties and thresholds at the Radiation Protection Service Du Toit Volschenk SABS.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
CHEMISTRY ANALYTICAL CHEMISTRY Fall Lecture 17 Chapter 13: Acid-Base Titrations.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Accreditation & Validation
EPIDEMIOLOGY AND BIOSTATISTICS DEPT Esimating Population Value with Hypothesis Testing.
Summary 1 l The Analytical Problem l Data Handling.
Supplementary Training Modules on Good Manufacturing Practice
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Chemometrics Method comparison
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 D. RuddThe Importance of “Good” Measurements.
Validation of Analytical Method
Laboratory Validation of Analytical Methods
WELCOME. UV Spectrophotometric Method Development And Estimation of Bicalutamide in Pharmaceutical Dosage Form.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 E. LeePT Scheme for Pre-university Students.
Determination of System Equivalency – Starting note for WLTP IWG Meeting #8 in Pune, India Audi, EA-52, V2.0 WLTP-08-09e.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 A. Townshend, G.M. GreenwayIntegration of.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 P. HoulgateAssessment of Test Kits in Terms.
VALIDATION METHODOLOGY
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
M. Rösslein, B. Wampfler Evaluation of Uncertainty in Analytical Measurements B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag.
Analytical considerations
VTT-STUK assessment method for safety evaluation of safety-critical computer based systems - application in BE-SECBS project.
Chem. 31 – 9/23 Lecture Guest Lecture Dr. Roy Dixon.
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Author: TitelKaus, R., Nagel, T.: Calibration and Detection Limits© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality.
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 P. RadvilaConcepts of Quality Management.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 J. Green Why do we need Good results? 1 Chemical.
Quality Control Lecture 5
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 A. RíosTraceability / Trackability 1 It is.
Chapter 8: Sampling, Standardization & Calibration
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 M. ValcárcelMetrology in Chemistry 1.
Data Analysis: Quantitative Statements about Instrument and Method Performance.
Chimiometrie 2009 Proposed model for Challenge2009 Patrícia Valderrama
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 H. Albus Basic Course Experiments to Demonstrate.
Introduction The importance of method validation
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 U. PyellBasic Course Experiments to Demonstrate.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
Chapter 1: Introduction Analytical Chemistry Analytical Chemistry Qualitative analysis Qualitative analysis Quantitative analysis Quantitative analysis.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Data handling Sabine Beulke, Central Science Laboratory, York, UK Kinetic Evaluation according to Recommendations by the FOCUS Work Group on Degradation.
 Routine viral diagnostics: indirect and direct detection of viruses. ◦ Indirect detection: serological tests; ◦ Direct detection:  Viral antigens;
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
EQUIPMENT and METHOD VALIDATION
Setting the requirements for a method (including aspects of MU) Bertil Magnusson, SP Technical Research Institute of Sweden.
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Serpil KILIÇ, Murat KILIÇ
World Health Organization
Principles of Instrumental Analysis
Dr. Birgit Schmauser, BfArM, Bonn
EPA Method Equivalency
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
EPA Method Equivalency
Analytical Method Validation
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
ANALYTICAL METHOD VALIDATION
World Health Organization
Umweltbundesamt, Austria
Multi-laboratory Method Validation
Presentation transcript:

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 1 Learning Objectives: Student n is able to inquire in sufficient depth on the purpose of analytical work n is able to translate this information into stepwise strategy keeping in mind suitable performance characteristics at each step n can devise experiments to test against these criteria performs statistical analysis of obtained data with the goal to make a valid judgement regarding the suitability of the method performs statistical analysis of obtained data with the goal to make a valid judgement regarding the suitability of the method Validation: an Example

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 2 Validation Must Be Performance Based  Definition of the need of the client translated to analytical quality criteria including cost and time  Compilation of candidate methods  Critical appraisal of candidate methods with respect to expected method performance  Design and execution of validation study  Evaluation of results, go-ahead or modifications or alternative method  Measure the unknown with due regard to previously established quality criteria

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 3 Worked Example: Fe 2 O 3 in MgO For certain industrial applications of MgO the upper limit of Fe oxide needs to be controlled very tightly  Definition of the need of the customer translated to analytical quality criteria including cost and time In this application an upper limit of 0.5 % was guaranteed by the supplier, the customer found 0.64 %, the supplier 0.41 %.

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 4 Deriving Minimum Performance Characteristics from Requirements  overall uncertainty (including sampling):<0.03 % uncertainty at required level of concentration from analysis itself:~0.01%uncertainty at required level of concentration from analysis itself:~0.01%  limit of quantitation (with matrix):<0.03 %  limit of detection (with matrix):<0.01 %  selectivity/interferences:CRM  linearity:at least % As the differences from one another was about 0.1 % Fe 2 O 3 the proposed method needs to have the following characteristics:

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 5 Preliminary Examination of Candidate Methods (1)

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 6 Preliminary Examination of Candidate Methods (2)

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 7 Validation Plan  Produce calibration curves for Fe by flame AA under standard conditions with and without MgO  Compare calibration functions  Evaluate limit of detection and limit of quantitation  Estimate precision for meeting previously established requirements (+ margin): allowance for day to day variability, etc.  Produce recovery data by mixing various aliquots of CRM MgO with high purity MgO  Compare with alternative method ?  Estimate (laboratory) sampling error for sample as received

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 8 Calibration without MgO

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 9 Calibration with MgO

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 10 Graphical Comparison without matrix with matrix mg/mL

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 11 EXCEL Macro ValiData  Basis of the program is ISO 8466 and DIN Homogeneity of variances test Calibration functions linear OR quadratic following Mandel´s test weighted linear and weighted quadratic standard additions  Performance characteristics Decision limit and detection limit from calibration Limit of quantitation Linear range, sensitivity, confidence limits  Recovery studies orthogonal regression robustregression

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 12 Numerical Comparison without matrix with matrix

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 13 Limits of Detection Limits of Quantitation without matrix LOD % with matrix LOD % LOQ %

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 14 Estimation of Recovery serial dilution of Burned Magnesite SRM 104 Fe content of % (1 s) with pure MgO between 0.1 and 0.6 % found/(given) found/(given) found found Slope IC (slope) Ordinate intersect IC (Ordinate intersect) is about % at 0.5 % level

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 15 Alternative Method: Titrimetry 1. dissolve SRM in HCl, dilute to 100 ml 2. reduce with SnCl 2 3. add 20 ml HgCl 2 and 50 ml Zimmermann-Reinhart- Solution 4. titrate with 0.01 n KMnO 4 Result: 7.01 % Fe 2 O 3 Certified: %

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 16 Estimation of Uncertainty from Sampling P about 500 g laboratory sample delivered P sampled “according to ISO” by customer P max. concentration about 1 % Fe in dark pieces P min. concentration below LOD in light pieces P many larger grains: ca 1 cm 3 corresponds to 3 g P total of 500 g/3 g ~ 160 pieces P 80 pieces give a relative uncertainty of 9 % P at the 0.5 % level this is % (0.02 % requ. !!!) CONCLUSION: Pthe laboratory sample must be about 2000 g

B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 17 Content of Validation Report Introduction Test principle Definition of the type of the analytical test procedure Definition of validation parameters Performance of the test Test outline and acceptance criteria Equipment qualification System suitability Qualification of samples and standards SummaryReferencesResults