TT2A Mercury Jet Experiment The Cryogenic System Roger Bennett and Yury Ivanyushenkov CCLRC, Rutherford Appleton laboratory, Chilto, Didcot, Oxon, OX11.

Slides:



Advertisements
Similar presentations
Cryomodule Helium Volumes Tom Peterson, Fermilab AWLC14 13 May 2014.
Advertisements

31/03/11FV 1 CEDAR from flammable gas safety point of view.
Harold G. Kirk Brookhaven National Laboratory The CERN Target Experiment Schedule and Budget MERIT Review BNL December 12, 2005.
A Neutrino Factory Target Station Design based on Solid Targets J. R. J. Bennett STFC, Rutherford Appleton Laboratory, Harwell Science.
Harold G. Kirk Brookhaven National Laboratory Targetry Plans and Status MUTAC Review FNAL March 17, 2006.
Solid Targets for the Neutrino Factory J R J Bennett Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, OX11 0QX, UK
1Managed by UT-Battelle for the U.S. Department of Energy MERIT Videoconference 11 Mar 2009 Neutrino Factory Cryostat 1 Concept V.B. Graves MERIT Videoconference.
CERN P186 Magnet cryogenic system update Yury Ivanyushenkov RAL December 7, 2004.
Spectrometer Solenoid Fabrication Update Steve Virostek Lawrence Berkeley National Lab MICE CM23 at ICST, Harbin January 14, 2009.
High Power Hg Target Conceptual Design Review Hg Target Interface with Solenoid V.B. Graves P.T. Spampinato T.A. Gabriel Oak Ridge National Laboratory.
2.April 2004A.Fabich, H.Kirk Summary for proposal of TT2A target test H.Kirk, A.Fabich March 2004 week 9 morning: Cryogenics,
The TT2A Experiment A Proposal to the ISOLDE and Neutron Time of Flight Experiments Committee
1 New baseline for the magnet cooling system Yury Ivanyushenkov Engineering and Instrumentation Department, Rutherford Appleton Laboratory.
Spectrometer Solenoid Fabrication & Testing Update Steve Virostek Lawrence Berkeley National Lab MICE CM24 at RAL June 1, 2009.
Videoconference, 3rd May 2005A.Fabich, CERN1 Nitrogen release from the TT2A cryogenic solenoid systems A.Fabich CERN AB-ATB, Switzerland Videoconference,
1 Technical Arguments in Favor of using the Cryomech PT-415 Cooler for Cooling the LH 2 Experiment Michael A. Green Lawrence Berkeley Laboratory Berkeley.
UCN Phase 2 Design Status September 10, Design Components Bulk Shielding Target Crypt Cryogenic Insert Target Insert UCN Port Beam Window Cooling.
MICE Hydrogen System Design Tom Bradshaw Iouri Ivaniouchenkov Elwyn Baynham Columbia Meeting June 2003.
MEBT & RT CH Section Thomas Page Fermilab Accelerator Advisory Committee May 10 th – 12 th, 2006.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
Patrick Thornton, SNS/FPE June 9, 2008
March 14, 2002GJG NCSX CRYOGENICS DESIGN DEVELOPMENT STATUS WBS-63.
Neutrino Factory Workshop UK Magnet Manufacturing Capability Elwyn Baynham CCLRC Rutherford Appleton Laboratory, UK Elwyn Baynham UKNF Oct 2003.
SuperFRS Multiplett and Dipole Vacuum Interfaces Multiplett: Insulation vacuum: Insulation Vacuum Pumping flanges: Two CF flanges of the size DN160 must.
LARP LQX and MQX Magnets Cryogenic Testing at Fermilab’s Industrial Building 1 Roger Rabehl Technical Division/Test & Instrumentation Department.
Initiatives in the Target Sector J. R. J. Bennett CCLRC, Rutherford Appleton Laboratory, Chilton, Didcot, Oxon. OX11 0QX, UK.
K. McDonald ICEC23-ICMC2010, Wroclaw July 20, Use of He Gas Cooled by Liquid Hydrogen with a 15-T Pulsed Copper Solenoid Magnet K.T. McDonald Princeton.
Arnaud Vande Craen (TE-MSC) 27/02/20131 EUCARD : ESAC Review – CEA Saclay.
Initiative in the Target Sector J. R. J. Bennett CCLRC, Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, OX11 0QX, UK.
Safety Requirements and Regulations 10/3/20121Safety Requirements & Regulations James Sears.
The MICE Hydrogen System Safety Review Introduction Tom Bradshaw, Yury Ivanyushenkov, Elwyn Baynham, Tony Jones, Mike Courthold and Matthew Hills Rutherford.
Cryogenic Gas Cooling of High Energy Lasers Paul Mason HEPTech – Cryogenics Meeting, Grenoble, France 4-5 th June 2015 STFC Rutherford.
Spectrometer Solenoid Fabrication Status and Schedule Steve Virostek Lawrence Berkeley National Lab MICE RAL October 20, 2008.
UKNF 12 January 2005 Target Studies J R J Bennett RAL.
Exhaust to atmosphere G1 V1 V2 V3 LN2 Storage Vessel 150 l Dewar Cryostat Exhaust to atmosphere Nitrogen or helium gas bottle LN2 Circuit for MIT Test,
1 Target Station Design for Neutrino Superbeams Dan Wilcox High Power Targets Group, Rutherford Appleton Laboratory NBI 2012, CERN.
L. Serio COPING WITH TRANSIENTS L. SERIO CERN, Geneva (Switzerland)
Harold G. Kirk Brookhaven National Laboratory The High-Power Target Experiment at CERN Report to MUTAC LBNL April 25, 2005.
Tungsten Powder Jet Update Ottone Caretta STFC Rutherford Appleton Laboratory, UK 2 nd Princeton-Oxford High Power Target Meeting 6-7 November-2008.
Progress on Hydrogen R&D System
July 2005A.Fabich, CERN AB-ATB1 MERIT (ntof11) experiment: Diagnostics A.Fabich CERN AB-ATB July 2005.
Johan Bremer, 22th-26th September 2008 Cryogenics Operations 2008, CERN, Geneva, Switzerland 1 CRYOGENICS OPERATIONS 2008 Organized by CERN Safety aspects.
To TT10 Nitrogen or helium gas LN2 Storage vessel buffer storage vessel G1G2 Magnet cryostat VALVE BOX Schematic diagram of the cryogenic system.
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
Process Definition of the Operation Modes for Super-FRS Magnet Testing CSCY - CrYogenic department in Common System, GSI, Darmstadt Y. Xiang, F. Wamers.
1 Small Coolers for MICE Michael A. Green University of Oxford Department of Physics Oxford OX1 3RH, UK MICE Collaboration Meeting RAL.
Cryostat & LHC Tunnel Slava Yakovlev on behalf of the FNAL team: Nikolay Solyak, Tom Peterson, Ivan Gonin, and Timergali Khabibouline The 6 th LHC-CC webex.
LHC Cryostat evaluation Nikolay Solyak Thanks Rama Calaga, Tom Peterson, Slava Yakovlev, Ivan Gonin C11 workshop. FNAL, Oct 27-28, 2008.
Harold G. Kirk Brookhaven National Laboratory The E951 Targetry Program Targetry Meeting CERN September 19, 2003.
Cryogenic Summary - K. C. Wu Testing D2L102 in MAGCOOLJune, 02 Difference between D2L102 and D2L101 Operating Summary Cooldown to 100 K and 6 K Test Condition.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
UITF ODH Assessment UITF Safety Review May 10, 2016.
Shrikant_Pattalwar ICEC 26, March 7-11, 2016, Delhi 1 Horizontal Tests in a Vertical Cryostat Shrikant Pattalwar STFC Daresbury Laboratory UK.
Pixel Cooling Upgrade (2013) 1 December 20081Hans Postema - CERN.
Progress on AFC Procurement T W Bradshaw Rutherford Appleton Laboratory Harwell Science and Innovation Campus Didcot, OX11 0QX, UK
The Super-FRS Multiplet, Magnetic and Cryogenic requirements
Final Design Cryogenic and mechanical configurations
Magnet cryogenic system update.
MQXC Nb-Ti 120mm 120T/m 2m models
Proximity Cryogenics P&IDs meeting
Progress and Issues with VTS Upgrade
The report on the IBR-2 modernization
LARP Vertical Test Facility
Small Coolers for MICE MICE Collaboration Meeting RAL Michael A. Green
LN2 Circuit for MIT Test, September 2005
MERIT Review Meeting Cryogenics BNL, NY Dec. 12, 2005 Friedrich Haug
A Complete System for Operation of a Superconducting Magnet*
Nitrogen release from the TT2A cryogenic solenoid systems
Schematic diagram of the cryogenic system
Safety Moment Vacuum Trap Safety.
Presentation transcript:

TT2A Mercury Jet Experiment The Cryogenic System Roger Bennett and Yury Ivanyushenkov CCLRC, Rutherford Appleton laboratory, Chilto, Didcot, Oxon, OX11 0QX, UK

Layout of the Cryosystem

The “SPECIFICATION” of the cryogenic cycle is: 1. Initial fill of the magnet cryostat slowly over many hours -12 hours 2. Operation of the magnet on the following cycle: When the magnet is at ~80 K, empty the cryostat and neighbouring beam lines, to prevent activation by the beam, in ~2-3 minutes. After energizing the magnet, ~10 s, cool the magnet with LN2 to ~80 K in ~30 minutes or less.

Scheme agreed at CERN, December 2004, drawn by Peter Titus

Design and Costing of the Cryogenic System 1. The input line from the storage vessel to the cryostat is recommended to be 1 cm diameter bore. 2. The vent line is recommended to be 7.5 cm diameter bore to allow the cryostat to be filled in <30 minutes. 3. The total cost of manufacture, installation, commissioning and operation is estimated to be £318k. This includes controls, staff costs and taxes but not the storage container which is assumed to be supplied by CERN.

Some Issues 1.Emptying the Cryostat. It will not be possible to remove the LN2 from the horizontal and vertical parts of the line. The line is 7 cm diameter and the helium gas, used to remove the LN2 from the cryostat, will bubble through the lines rather than push it out through the vent. 2.Is it necessary to empty the cryostat before each pulse? The radioactivity of the LN2 will be quite small for only beam pulses. It is probably acceptable to release this into the atmosphere. 3. Is there a problem with the irradiation of liquid air trapped in and below the foam insulation on the large end flange of the cryostat? This needs careful consideration because of the danger of explosion of the oxygen in the liquid air under irradiation.

V1 V4 vent LN2 storage vessel ground level magnet cryostat If the cryostat is not emptied before beam pulses, this would reduce the cycle time and give a very simple cryogenic system