Product Introduction January 2009

Slides:



Advertisements
Similar presentations
The next generation of VITODENS 200
Advertisements

Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Energy Efficient Steam Systems
VF™ Series Boiler.
Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
Customer Service – International dept. STAR 24 3 E.
Sizing, Installation November 2008
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Mini 24 Presents the new. Wall-hung boiler Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Unit 206: Domestic hot water systems
TYPES OF MECHANICAL SYSTEMS
Basic Refrigeration Cycle
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
 25,000 BTU per Cell  Cell Halves Edge Seams Folded and Crimped. Individual Cells Welded Together to Form Completed Heat Exchanger Assembly.  20 Gauge.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Heating Control Devices
HIGH EFFICIENCY WATER HEATERS - Residential Gas - Polaris ®
Millivolt Troubleshooting Guide Gas Products NOVA SIT Valves 1) Thermocouple Millivolt Check 2) Safety Magnet Testing 3) Thermopile Millivolt Check 4)
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.
Objective of the session.
11-1 Copyright  2010 McGraw-Hill Australia Pty Ltd PowerPoint slides to accompany Puffett, Hossack, Stone, Burn & Miles, Gasfitting 2e Chapter 11 OPERATION.
Furnace Troubleshooting
Gas Furnace Controls Part 4.
35” CONDENSING GAS FURNACES Vent and Combustion Air System Design & Installation 1 Add Distributor Art and Text Here.
Unit 208: Central heating systems
Customer Service VICTRIX 90 Central heating only, wall hung condensing boiler.
DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers Ferroli Ferroli, in line with its position as a comfort.
Engineer Presentation
Project Summary. Mission Statement To develop a Volumetric Flow Sensor to measure the volume of gas flowing through a quadrant and into the combustion.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Product Introduction.
STEAM HEATING.
Hydronic Mechanical Controls
Gas Furnace Planned Maintenance
© 2011 Rinnai America Corporation TANKLESS WATER HEATING TECHNOLOGY For Commercial.
Gas Turbine Power Plant
HVAC523 Basic Subsystems.
Product and Accessories
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
CHILLED WATER AIR-CONDITIONING SYSTEMS
RELIABILITY ON DEMAND INTRODUCING A COMPLETE LINE OF TANKLESS GAS WATER HEATERS.
Simplicity Series The 1st Fuel-Convertible Concentric Vent
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
Water Heaters 101 Residential Gas and Electric. Outline Basic water heater features Residential gas overview Residential electric overview Q&A.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – March 2011eere.energy.gov COMBUSTION BASICS HEATING SYSTEMS FOR ENERGY AUDITORS AND INSPECTORS.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
Fan Coil Controller FC/S 1.1
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Easy 40 Gallon Tank Replacement
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
Hot water Systems Heaters.
Hot Water Systems Cylinders and Systems.
XP PLUS Intro High Efficiency Circulating Water Heater
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
NEW ARISTON STORAGE BOILERS March, 2009.
Presentation transcript:

Product Introduction January 2009 Quietside ODW 099A-199A Product Introduction January 2009

ODW 099A – 199A

Line Up 4 models in 2 Chassis sizes 099 & 120 : Smaller capacities designed for lighter demand applications – Condos, apartments, cottages, townhouses or houses where low to medium demand exists 180 & 199 : High capacity for higher demand application - larger residences or any application where “performance bathing or showering” is in place

What do you get in the Box? Unit, set up for Natural Gas operation Unit Controller Vent Termination kit, including co-axial flue, termination kit and screws Isolation kit, includes Ball Valves, purge valves and ASME rated Pressure Relief Valve

What does the contractor supply? Gas piping, minimum ¾” but selected for the Btu/h input capacity of the unit Schedule 40 PVC venting including Elbow and Bird Screen for vent Water piping from cold supply to unit and hot water piping to house Wiring connection to 115V power and thermostat wire to the controller

What is the Quietside value? From one our largest competitors Unit Controller $38 Vent Termination kit $62 Isolation kit $104 Stainless Steel Vent Pipe ??? Total $204 plus venting

Delivered Domestic Hot Water Temp (DegF) Performance ODW-099A   Delivered Domestic Hot Water Temp (DegF) GPM 100 105 110 120 130 140 Min. Max. Cold 35 0.5 2.74 0.46 2.54 0.43 2.37 0.38 2.09 0.34 1.87 0.31 1.69 Water 40 0.54 2.97 0.4 2.22 0.36 1.98 0.32 1.78 Temp 45 0.59 3.24 DegF 50 0.65 3.56 55 0.72 3.95 60 0.81 4.45 65 0.92 5.08

Delivered Domestic Hot Water Temp (DegF) Performance – ODW 120A   Delivered Domestic Hot Water Temp (DegF) GPM 100 105 110 120 130 140 Min. Max. Cold 35 0.5 3.32 0.46 3.08 0.43 2.88 0.38 2.54 0.34 2.27 0.31 2.05 Water 40 0.54 3.59 0.4 2.7 0.36 2.4 0.32 2.16 Temp 45 0.59 3.92 DegF 50 0.65 4.31 55 0.72 4.79 60 0.81 5.39 65 0.92 6.16

Delivered Domestic Hot Water Temp (DegF) Performance – ODW 180A   Delivered Domestic Hot Water Temp (DegF) GPM 100 105 110 120 130 140 Min. Max. Cold 35 0.72 4.98 0.67 4.62 0.62 4.31 0.55 3.81 0.49 3.41 0.45 3.08 Water 40 0.78 5.39 0.58 4.04 0.52 3.59 0.47 3.24 Temp 45 0.85 5.88 DegF 50 0.93 6.47 55 1.04 7.19 60 1.17 8.09 65 1.34 9.24

Delivered Domestic Hot Water Temp (DegF) Performance – ODW 199A   Delivered Domestic Hot Water Temp (DegF) GPM 100 105 110 120 130 140 Min. Max. Cold 35 0.72 5.5 0.67 5.11 0.62 4.77 0.55 4.21 0.49 3.77 0.45 3.41 Water 40 0.78 5.96 5.50 0.58 4.47 0.52 3.97 0.47 3.58 Temp 45 0.85 6.50 DegF 50 0.93 7.15 55 1.04 7.95 60 1.17 8.94 65 1.34 10.22

Efficiency All units have an EF of above 0.90 New Energy Star program for On Demand is 0.82 minimum IRS tax rebates start at 0.80 Testing verified at ETL or BR Labs

S Line Condensing S Line is the name given to the flow of combustion gas through the heat exchangers Two heat exchangers, Primary and Wet Recuperative are used to transfer heat from combustion to the water

S Line Condensing

What does Condensing mean? Increased efficiency using the by products of combustion to further heat water or air

Combustion During combustion, 1 cubic Meter of Natural Gas (Methane) makes 2 cubic meters of Water Vapor (Steam)

Recuperation of Latent Waste Heat

So how does it work? As the combustion gases pass over the heat exchanger heat is transferred to the water By adding a separate heat exchanger and having the inlet water enter that first additional heat exchange can be obtained removing heat and water from the combustion gas This removed water is called condensate and must be disposed of Basic theory is the colder the water entering the wet recuperative heat exchanger the higher the efficiency but………….. And obviously the higher the water temperature entering the unit the lower the performance gains are

Condensate Condensate is acidic, the colder the water the more acidic the condensate Therefore it has to be treated and the wet recuperative has to be able to withstand this This is why condensing water heaters have only recently become a viable option

Useful advantages of condensing Lower Flue gas temperatures ODW maximum flue gas temperature is 136 DegF This allows venting in Schedule 40 PVC in all states and provinces, with zero clearance

Venting Description – Sealed combustion or Direct Vent Both Intake and Exhaust air provided to the unit Ø3” for 099 & 120 Ø4” for 180 & 199

Venting Maximum vent length is 45ft equivalent, this is a per pipe length not a total Maximum 3 Elbows in vent pipe Each Elbow = 5ft of straight pipe, therefore with 3 Elbows in the system the maximum length of straight pipe is 30ft Less elbows = more straight pipe Termination already included, designed for Side wall mounting only

Vent Connection on unit Recent experience has told us that it needs to be simple to attach the venting to the unit Plastic connection to accept either 3” or 4” pipe directly on top of the unit PVC cement is required to bond the two together

Unit Control Standard control is via a wired controller which can be mounted either adjacent to the water heater or in a bathroom An optional Priority controller is available for a total of 2 controls on the system

Controller Up and Down Buttons set the required hot water temperature from the unit Temperature can be set from 98-114 DegF in 2 DegF increments or 120, 130, 140, 150 & 160 DegF settings Factory default is 104 On/Off Button turns the Unit On or Off as required Priority button allows the second thermostat to override the main

Optional Priority Controller Priority Light is lit. This allows the Second thermostat to override the main Use if you want a hotter shower than allowed for a kid’s shower Up and Down Buttons set the required hot water temperature from the unit different to that of the main controller Temperature can be set from 98-114 DegF in 2 DegF increments or 120, 130, 140, 150 & 160 DegF settings Factory default is 104 On/Off Button turns the Unit On or Off as required

Delivered Water Temperature Control A stable delivered water temperature is of paramount importance We have 3 temperature sensors on this unit Entering Cold Water temperature Water temperature exiting the Heat Exchangers Delivered Water temperature

Delivered Water Temperature Control 2 Control valves are used Flow Control Valve Measure the flow rate through the unit and report back to the main controller Minimum flow rate for operation is 0.7 GPM

Delivered Water Temperature Control Bypass Control Valve This valve allows water to flow from supply to delivered water without passing through the heat exchanger

Why Bypass Control? Mixing in some cold water allows for a stable delivered water temperature, no peaks and troughs due to burner modulation Increases flow rate as we can provide a mixed condition water temperature Provides flow control in times of extremely high flow rates

End Result Hi Pro-Tech Reduced temperature fluctuations compared to competition and previous iterations of On Demand Water heaters

Capacity Modulation In order to provide performance across the range of flow rates available to the unit Modulation or turn down must be high, these units feature up to 8:1 turn down ratio

Modulation Range ODW 099A : 18,000 to 99,000 Btu/h

Burner Assembly Dual burner assembly using in shot type of burner

LP Gas Conversion Replace burner manifold assembly with one specific to LP Change dip switch #1 to tell the unit that it is now LP

Noise Levels Unit uses an up flow design path for the combustion air This reduces the observed noise level as the induction noise is reduced compared to the previous Quietside units

Freeze Protection 48W Ceramic heaters attached to the water pipes Thermostat controlled when inlet air temperature drops to 41 DegF

Safeties 15 Specific Error codes controlling the unit Overheat, Ignition failure, sensor errors, condensate overflow, air pressure, fan motor, flame failure, freeze protection etc Error codes displayed on the unit controller All error codes require unit to be reset, except for freeze protection

Bar code tracking system The unit and the main components such as main circuit board, pump motor, three way valve, modulating gas valve, and plate heat exchanger has an individual bar code The assemblers scan the data and save it with the bar code of the entire unit to the main server of the facility. If any problems with the components are found, you can trace where the product is installed.

Warranty Standard Warranty Residential usage 12 Years Heat Exchanger 5 Years Parts No labor allowance as standard