Features of PID Controllers

Slides:



Advertisements
Similar presentations
Dynamic Behavior of Closed-Loop Control Systems
Advertisements

PID Implementation Issues
Model-based PID tuning methods Two degree of freedom controllers
ERT 210 Process Control & dynamics
PID Controllers and PID tuning
Discrete Controller Design
Dynamic Behavior of Closed-Loop Control Systems
CHE 185 – PROCESS CONTROL AND DYNAMICS
Chapter 4: Basic Properties of Feedback
Ratio Control Chapter 15.
CHAPTER V CONTROL SYSTEMS
3442 Industrial Instruments 2 Chapter 9 Controller Principles
PID Control -1 + Professor Walter W. Olson
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
Controllers With Two Degrees of Freedom
Feedback Controllers Chapter 8
Control System Design Based on Frequency Response Analysis
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Chapter Summer 2. Comparator 3. Block Blocks in Series
Dynamic Behavior and Stability of Closed-Loop Control Systems
Controller Tuning: A Motivational Example
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
CONTROL SYSTEM INSTRUMENTATION
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Process Control Instrumentation II
Process Control Instrumentation II
Feedback Controllers Chapter 8.
بسم الله الرحمن الرحيم PID Controllers
Chapter 7 PID Control.
PID Feedback Controllers PID 反馈控制器
Proportional/Integral/Derivative Control
Lecture 5: PID Control.
Hairul Nazirah bt Abdul Halim
Ch. 6 Single Variable Control
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Introduction to Process Control
PID Controller Design and
Control Systems and Adaptive Process. Design, and control methods and strategies 1.
Low Level Control. Control System Components The main components of a control system are The plant, or the process that is being controlled The controller,
Feedback Controllers Chapter 7.
Feedback Control system
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Chapter 7 Adjusting Controller Parameters Professor Shi-Shang Jang Chemical Engineering Department National Tsing-Hua University Hsin Chu, Taiwan.
PID CONTROLLERS By Harshal Inamdar.
ERT 210/4 Process Control Hairul Nazirah bt Abdul Halim Office: CHAPTER 8 Feedback.
Chapter 8 Feedback Controllers 1. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control.
Miss Hairul Nazirah bt Abdul Halim
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
Feedback Controllers Chapter 8
Process Control Methods 1. Open-Loop Control 2 Process control operations are performed automatically by either open-loop or closed-loop systems Processes.
Control Loops Tune a Fish. Control Loops Tuning of a control loop involves selecting loop parameters to ensure stable control under all operating conditions.
ERT 210/4 Process Control & Dynamics DYNAMIC BEHAVIOR OF PROCESSES :
Lecture 9: PID Controller.
Advanced control strategies. CONTROL SYSTEMS The process parameters which are measured using probes described in the previous sections may be controlled.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
1 PID Feedback Controllers PID 反馈控制器 Dai Lian-kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
EEN-E1040 Measurement and Control of Energy Systems Control I: Control, processes, PID controllers and PID tuning Nov 3rd 2016 If not marked otherwise,
Feedback Controllers Chapter 8
CHAPTER V CONTROL SYSTEMS
Controllers and Positioners
Controller Tuning: A Motivational Example
Process Control Engineering
Features of PID Controllers
Feedback Controllers Chapter 8
Proportional Control and Disturbance Changes
PID Controller Design and
Presentation transcript:

Features of PID Controllers Elimination of Derivative and Proportional Kick One disadvantage of the previous PID controllers is that a sudden change in set point (and hence the error, e) will cause the derivative term momentarily to become very large and thus provide a derivative kick to the final control element. Chapter 8

Chapter 8 Reverse or Direct Action This sudden change is undesirable and can be avoided by basing the derivative action on the measurement, ym, rather than on the error signal, e. We illustrate the elimination of derivative kick by considering the parallel form of PID control in Eq. 8-13. Replacing de/dt by –dym/dt gives Chapter 8 Reverse or Direct Action The controller gain can be made either negative or positive.

For proportional control, when Kc > 0, the controller output p(t) increases as its input signal ym(t) decreases, as can be seen by combining Eqs. 8-2 and 8-1: This controller is an example of a reverse-acting controller. When Kc < 0, the controller is said to be direct acting because the controller output increases as the input increases. Equations 8-2 through 8-16 describe how controllers perform during the automatic mode of operation. However, in certain situations the plant operator may decide to override the automatic mode and adjust the controller output manually. Chapter 8

Figure 8. 11 Reverse and direct-acting proportional controllers Figure 8.11 Reverse and direct-acting proportional controllers. (a) reverse acting (Kc > 0. (b) direct acting (Kc < 0) Chapter 8

Chapter 8 Example: Flow Control Loop Assume FT is direct-acting. 1. Air-to-open (fail close) valve ==> ? 2. Air-to-close (fail open) valve ==> ?

Chapter 8 Automatic and Manual Control Modes Automatic Mode Controller output, p(t), depends on e(t), controller constants, and type of controller used. ( PI vs. PID etc.) Manual Mode Controller output, p(t), is adjusted manually. Manual Mode is very useful when unusual conditions exist: plant start-up plant shut-down emergencies Percentage of controllers "on manual” ?? (30% in 2001, Honeywell survey) Chapter 8

Chapter 8 Example: Liquid Level Control Control valves are air-to-open Level transmitters are direct acting Chapter 8 Questions: 1. Type of controller action? 2. What type of fish?

On-Off Controllers Chapter 8 Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control due to continuous cycling of controlled variable  excessive wear on control valve. Chapter 8

On-Off Controllers (continued) Synonyms: “two-position” or “bang-bang” controllers. Chapter 8 Controller output has two possible values.

Practical case (dead band) Chapter 8

Chapter 8

Chapter 8 Proportional-Integral (PI) Control Response to unit step change in e: Chapter 8 Figure 8.6. Response of proportional-integral controller to unit step change in e(t).

Chapter 8 Integral action eliminates steady-state error (i.e., offset) Why??? e  0  p is changing with time until e = 0, where p reaches steady state. Transfer function for PI control Chapter 8

Chapter 8 ("repeats per minute") instead of I . For PI controllers, Some controllers are calibrated in 1/I ("repeats per minute") instead of I . For PI controllers, is not adjustable. Derivative Control Action Ideal derivative action Used to improve dynamic response of the controlled variable Derivative kick (use db/dt ) Use alone? Chapter 8

Chapter 8 PID Controller Transfer function (ideal) Ideal controller Transfer function (ideal) Chapter 8 Transfer function (actual) α = small number (0.05 to 0.20) lead / lag units

Chapter 8 Controller Comparison P - Simplest controller to tune (Kc). - Offset with sustained disturbance or setpoint change. PI - More complicated to tune (Kc, I) . - Better performance than P - No offset - Most popular FB controller Chapter 8 PID - Most complicated to tune (Kc, I, D) . - Better performance than PI - No offset - Derivative action may be affected by noise

Chapter 8 Typical Response of Feedback Control Systems Consider response of a controlled system after a sustained disturbance occurs (e.g., step change in the disturbance variable) Chapter 8 Figure 8.12. Typical process responses with feedback control.

Figure 8.13. Proportional control: effect of controller gain. Chapter 8 Figure 8.15. PID control: effect of derivative time.

Chapter 8 Figure 8.14. PI control: (a) effect of reset time (b) effect of controller gain.

Summary of the Characteristics of the Most Commonly Used Controller Modes 1. Two Position: Inexpensive. Extremely simple. 2. Proportional: Simple. Inherently stable when properly tuned. Easy to tune. Experiences offset at steady state. 3. Proportional plus integral: No offset. Better dynamic response than reset alone. Possibilities exist for instability due to lag introduced. Chapter 8

Chapter 8 4. Proportional plus derivative: Stable. Less offset than proportional alone (use of higher gain possible). Reduces lags, i.e., more rapid response. 5. Proportional plus reset plus rate: Most complex Rapid response No offset. Difficult to tune. Best control if properly tuned. Chapter 8

Chapter 8 Position and Velocity Algorithms for Digital PID Control A straight forward way of deriving a digital version of the parallel form of the PID controller (Eq. 8-13) is to replace the integral and derivative terms by finite difference approximations, Chapter 8 where: = the sampling period (the time between successive measurements of the controlled variable) ek = error at the kth sampling instant for k = 1, 2, …

There are two alternative forms of the digital PID control equation, the position form and the velocity form. Substituting (8-24) and (8-25) into (8-13), gives the position form, Chapter 8 Where pk is the controller output at the kth sampling instant. The other symbols in Eq. 8-26 have the same meaning as in Eq. 8-13. Equation 8-26 is referred to as the position form of the PID control algorithm because the actual value of the controller output is calculated.

In the velocity form, the change in controller output is calculated In the velocity form, the change in controller output is calculated. The velocity form can be derived by writing the position form of (8-26) for the (k-1) sampling instant: Note that the summation still begins at j = 1 because it is assumed that the process is at the desired steady state for and thus ej = 0 for . Subtracting (8-27) from (8-26) gives the velocity form of the digital PID algorithm: Chapter 8

The velocity form has three advantages over the position form: It inherently contains anti-reset windup because the summation of errors is not explicitly calculated. This output is expressed in a form, , that can be utilized directly by some final control elements, such as a control valve driven by a pulsed stepping motor. For the velocity algorithm, transferring the controller from manual to automatic mode does not require any initialization of the output ( in Eq. 8-26). However, the control valve (or other final control element) should be placed in the appropriate position prior to the transfer. Chapter 8