Biochemical instrumental analysis-14

Slides:



Advertisements
Similar presentations
Sampling and Measurement for Volatile Organic Compounds
Advertisements

1 Making and staining a wet mount Refer to the Practical Manual Introduction Sections F.1 and F.2.
Review of Analytical Methods for Nutrient Parameters focusing on Nitrates An Overview By Michael Jackman Chemistry Expert.
MLAB 2401: Clinical Chemistry Keri Brophy-Martinez
ORYX Microbatch Screening Ran Meged -1-. Microbatch oil protein & reagent solution -2-
Prof. of Clinical Chemistry, Mansoura University.
Cerebrospinal Fluid (CSF) Analysis for total protein
Distributor Meeting MEDICA November, 2009 Dr. Ariel Weisz R&D Department Metrolab, Argentina.
2.3 Separating the Substances in a Mixture
Automated Methods of Analysis
DETERMINATION OF BLOOD GLUCOSE CONCENTRATION
Glucose test Ms. Ibtisam alaswad Ms. Nour A. taim.
Gel Filtration Chromatography.
Assay the Activity of Creatine Kinase (CK)-total in Serum Dept.of Biochemistry.
P RINCIPLES OF C LINICAL C HEMISTRY A UTOMATION. A UTOMATION I N C LINICAL C HEMISTRY The modern clinical chemistry laboratory uses a high degree of automation.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Laboratory Equipment Lab Procedures January 12, 2010.
Mrs. Ibtisam H. Alaswad Mr. Mohammed A. Jaber
Double Beam spectrometer Provides a signal that is largely free of drift in the source and detector without requiring really expensive components Beam.
Lab Bot 800 Dual Arm Fully Automated Liquid Handling Workstation.
AUTOMATION OF ANALYSIS. Some Advantages of automation: Some applications: - quality control - process control - environmental monitoring.
Urinary System. Question of the Day Is it safe to drink your own urine?????
AUTOANALYZER T. Elsarnagawy 22/12/ Elsarnagawy, MASH
3 Laboratory Automation.
Portfolio InCCA - Key Messages
Evaluation of Beckton-Dickinson PST II and SST II Blood Collection Tubes P Graham, B Martin, M Roser, G Jones Department of Chemical Pathology, St Vincent’s.
Proteomics Module Day 1 Tech talk. Experiment: Yeast protein expression changes caused by H 2 O 2 exposure. ► 2 Control groups (A and B): nothing added.
BY : Dr. Beenish Zaki, Instructor Department of Biochemistry (15 February 2012)
Errors Requesting appropriate tests Writing prescription Reading prescription Sample collection Sampling times environmental factors Drug interferences.
Blood Collection and Handling of Blood Samples. Collecting your Sample Determine which ________________ are needed. Determine the __________________ you.
P RINCIPLES OF C LINICAL C HEMISTRY A UTOMATION. A UTOMATION I N C LINICAL C HEMISTRY The modern clinical chemistry laboratory uses a high degree of automation.
Printed by Techniques for Increasing Productivity in ICP Spectrometry Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd.,
Principles of Clinical Chemistry Automation
HPLC – High Performance Liquid Chromatography
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Laboratory Equipment Lab Procedures VTHT 1202.
L ABORATORY Q UALITY C ONTROL. INTRODUCTION _A major role of the clinical laboratory is the measurement of substances in body fluids or tissues for the.
Prof. Moustafa M. Mohamed
By: EID ALATAWI Serial Dilution. Introduction: Many of the laboratory procedures involve the use of dilutions. It is important to understand the concept.
CLINICAL CHEMISTRY Introduction to basic clinical chemistry BY BRUCE MUTUA.
Enzymatic analyses on wine By Wernich Kühn Central Analytical Facility Stellenbosch University.
CLINICAL CHEMISTRY AUTO-ANALYZERS
prepared by Dr. Akaber Tarek Biochemistry Department Clinical Chemistry prepared by Dr. Akaber Tarek Biochemistry Department Clinical Chemistry prepared.
Introduction to Chemical Analysis
Veterinary Practice Laboratory Unit 1 Chapter 2 General Laboratory Equipment Copyright © 2015 by Mosby, an imprint of Elsevier Inc. All rights reserved.
Determination Of Albumin In Serum By Bromocresol Green Method
General Approach in Investigation of Haemostasis
Spectrophotometry Measuring Concentrations of Substances in Body Fluids.
Laboratory Quality Control
UV/VIS SPECTROSCOPY.
VARIOUS LABORATORY INSTRUMENTS IN ACC
General Approach of Haemostasis
Introduction to Basic Clinical Chemistry
Medical Electronics - K.Srinivasamoorthi
Beaker A beaker is a simple container, commonly used in many laboratories. There are a variety of common sizes (50-, 100-, 250-, 600- mL and 1-liter).
General Approach in Investigation of Hemostasis
دکتر جعفر علاوی طوسی، متخصص پاتولوژی
Gel Filtration Chromatography.
Cerebrospinal Fluid (CSF) Analysis for total protein
RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY.
Important Extra Information Doctors slides Doctors notes
به نام خدا تضمين کيفيت در آزمايشگاه
Lab Activity 5 Biuret Method
Lab Activity 6 Biuret Method
Gel Filtration Chromatography.
Elsarnagawy, MASH Autoanalyzer T. Elsarnagawy 22/12/1432.
Kap.11 Clinical laboratory
Aim #12: What are some other tools biologists use in the laboratory?
Automated Methods of Analysis
High performance liquid chromatography (HPLC)
Presentation transcript:

Biochemical instrumental analysis-14 Dr. Maha Al-Sedik

Automation

During the past few year, there has been a considerable increase in clinical demand for laboratory investigations. When the volume of work increased, there must be a need for work simplification.

Definition Laboratory automation: is the use of instrument and specimen processing equipment to perform clinical assay with only minimal involvement of the technologist. Another definition is mechanization of the laboratory work.

Sure

Why automation? 4 decrease 2 increase 1 funny Decrease human error. Decrease liability to infection. Decrease laboratory costs. Decrease time needed for the test. increase productivity. Increase number of tests for the same sample.   Employ relatively less skilled laboratory technician. 

I-Continuous flow analysers In these systems, the samples and reagents are passed sequentially through the same analytical pathway and separated by means of air bubbles.

Samples were aspirated into tubing to introduce samples into a sample holder. Bring in reagent. Create a chemical reaction. Pump the chromogen solution into incubator then cuvette for spectrophotometric analysis.

Principle of detection: Detection is by measuring absorbance by spectrophotometer through a continuous flow cuvette (cell) at a certain wavelength. When there is no sample, the sample probe is placed in distilled water to avoid blockages, clogging and precipitation.

Disadvantages: 1-The machine does not allow test selection, all tests must be performed even if not requested. 2-The machine must run continuously even when there are no tests. 3-Because of the continuous flow, reagents must be drawn at all times even when there are no tests to perform.

4-The instrument must be closely monitored all the time for air bubbles uniformity; reagent availability and tubing integrity and most important of all carry over problems. 5-They are usually large in size and occupy large space.

II-Discrete analyzers Discrete analysis is the separation of each sample and accompanying reagents in a separate container. Discrete analyzers have the capability of running multiple tests on one sample at a time or multiple samples one test at a time. They are the most popular and versatile analyzers and have almost completely replaced continuous flow.

Sample reactions are kept discrete (separated) through the use of separate reaction cuvettes, cells, slides, or wells that are disposed of following chemical analysis. This keeps sample and reaction carryover to a minimum but increases the cost per test due to disposable products.

Hitachi 902 Analyzer

How it work? The Operator selects the test(s) he would like to run and enters the Sample IDs and any other information for the analysis. Sample test tubes and reagent bottles are loaded onto the system. The run is started.

The system uses its robotic arm, sample needle and syringe to mix samples and reagents in the reaction cuvettes.  Once the end point of the reaction is completed, the photometer measures the resultant absorbance.

The data is collected by the software. The data can be printed. Discrete analyzers have the capability to run multiple tests one sample at a time or multiple samples one test at a time. They are the most common analyzers.

Discrete analyzer Batch analysers Stat analysers

(A) Batch analysers: These are convenient to analyse specimen in batches ( groups ) such as of sugar, urea or creatinine etc. state testing may not be conveniently carried out on these analysers. The batch analysers can be further differentiated as semi automated. fully automated.

(B) Stat Analysers: In the case of these analysers many reagents (8 to 20 or more) can be pipetted one after another, so that various biochemical determinations can be performed on one specimen, according to the number of tests ordered for the patient.

Sample 1 glucose, urea, creatinine and electrolytes. Each sample is treated differently according to the tests requested and programmed by the operator. E.g. Sample 1 glucose, urea, creatinine and electrolytes. Sample 2 total protein, albumin, calcium. Sample 3 triglycerides, cholesterol. Sample 4 bilirubin, ALT, AST, ALP.

III-Centrifugal Analyzer Samples and reagents are added in a specially designed centrifugal type cuvette that has three main compartments. Sample is added from the sample cup by auto-sampler into the sample compartment of the centrifugal cuvette. The reagent probe into the reagent compartment of the centrifugal cuvette adds Reagent.

Both sample and reagents are allowed to equilibrate to the reaction temperature. Mixing of sample and reagent occurs when the rotor holding the cuvette is spun at high speed (4000 rpm) and then sudden stop. The spinning causes the sample to be added to the reagent while the turbulence caused by sudden stop results in mixing of sample and reagent.

After mixing, the rotor is spun at 1000 rpm After mixing, the rotor is spun at 1000 rpm. The reaction mixture is pushed horizontally to the bottom of the cuvette. Principle of detection: It has clear transparent sides for spectrophotometric measurement.

Advantages: Rapid test performance analyzing multiple samples. Batch analysis is a major advantage because reactions in all cuvettes are read simultaneously.