Non-Invasive Blood Pressure Device for Use in fMRI Imaging Applications November 18, 2004 Jose Alvarado Ben Huh Sanjeet Rangarajan Dr. André Diedrich Dr.

Slides:



Advertisements
Similar presentations
Key Stage 4 Magnetic Resonance Imaging Watching the brain at work
Advertisements

Electronics Cooling MPE 635
Piotr Wolański Warsaw University of Technology, Warsaw, Poland.
Optical Fiber. Prepared By AbdulRahman AlKhayyat Mohamed Felimban.
Michael Ghoorchian. Fiber Optic An optical fiber is a glass or plastic fiber that carries light along its length so it acts as a Wave guide. Mostly made.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques  Pipeline systems  Transmission lines  Pipe.
Fiber Optics BASIC FIBER OPTIC LINK.
Michael Shadrin 4/25/11 Comp 089.  The evolution of modern technology played a crucial role in advancing medicine.  Computer technology has become an.
Ventricle Chamber Valve Imaging Chamber ECG Machine Aortic Compliance Chamber Buffer Chamber Secondary Compliance Chamber Flow Meter Pressure Sensors DAQ.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques ä Pipeline systems ä pipe networks ä measurements.
Electromagnetic Flowmeter Why use flow meters What is a magnetic flow meter – How do they work – How are the different from other meters Items that will.
8. Power in electric circuits
Basic Electricity.
Cutting Edge Technologies Presented By: Ms Uzma Awan.
Vinai Hudda.  What we know so far  Who can contribute to Reduce Rolling Resistance  Tyre Industry’s Role  Pneumatic Tyre – Awareness Level  Effect.
Electricity, Electronics And Ham Radio “Kopertroniks” By Nick Guydosh 4/12/07.
Fiber Optics LINK LOSS BUDGET.
Introduction to Engineering and Technology Concepts Optical and Fluid Technologies.
1 Chapter Two Electrical & Computer Engineering Specialization.
Chapter 2.  Types of Network  Circuit Switched & Packet Switched  Signaling Techniques  Baseband & Broadband  Interference  Transmission Medium.
Introduction to Engineering and Technology Concepts Unit Four Chapter Three – Optical and Fluid Technologies.
In Engineering --- Designing a Pneumatic Pump Introduction System characterization Model development –Models 1, 2, 3, 4, 5 & 6 Model analysis –Time domain.
A System View of Optical Fiber Communication prt.2 AbdulRahman AlKhayyat Mohamed Felimban
 What is fiber-optic communication?  Method of transmitting information from one place to another  Sending pulses of light through optical fiber 
Sensors are mostly electronic devices used to monitor or capture something.
Brain Research Methods Maddie Coates. Direct Brain Stimulation Direct brain stimulation is when a device is sends a weak electrical current to disrupt.
Transmittance Measurement Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
Erik Simpanen September 27 th, 2011 BME 281. Heart Disease  A generic term for referring to numerous different forms of sicknesses that effect the heart.
Lecture 8 Cable Certification & Testing:. Cable Distribution Cable Distribution Equipment UTP (Unshielded Twisted Pair) UTP Cable Termination Tools UTP.
Introduction to Engineering and Technology Concepts Unit Five Chapter Two – Medical Technologies.
Generator and Transformer. Moving Conductor If a straight conductor is moved in a path perpendicular to a magnetic field, a current is induced in the.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
Non-Invasive Blood Pressure Waveform Monitoring in Mice By Andrew McClellan Laura Miller.
Optical Imaging of Intrinsic Cortical Signals Group #24 Shivani Shah, Ania Warczyk, Alia Durrani, Daniel Maxwell, Timothy Chen.
Methodology PET and MRI scanning How do we investigate the brain?
Brain Research Methods.
Measuring Monkey Eye Movement in the MRI Team Members: Josh Anders Betsy Appel Bryan Baxter Alyssa Walsworth Client: Luis Populin,Ph. D. Advisor: Justin.
Non-Invasive Blood Pressure Device for Use in fMRI Imaging Applications February 18, 2005 Jose Alvarado Benjamin Huh Sanjeet Rangarajan Dr. André Diedrich.
WIEGAND TECHNOLOGY Christmas is almost here ! Oupps! Sorry…Wrong topic… Christmas is almost here ! Oupps! Sorry…Wrong topic…
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
Non-Invasive Blood Pressure Device for Use in fMRI Imaging Applications February 18, 2005 Jose Alvarado Benjamin Huh Sanjeet Rangarajan Dr. André Diedrich.
Transformer Gas Tester Agenda Application Historical Solutions RKI’s Solution Features & Benefits Marketing.
Authors: Noor Mohammed Dr. M.Z. Hossain Dr. Sumon Saha
A Cost Effective Centralized Single parameter Patient Monitoring System Abstract Lack of Medical monitoring equipment's in rural areas of underdeveloped.
Abstract Client Expectations References Acknowledgments Richard Bamberg, Dustin Gardner, Matt Kudek, Chelsea Wanta Advisor: Willis Tompkins, Ph.D. Client:
Signal conditioning Noisy. Key Functions of Signal Conditioning: Amplification Filter  Attenuation  Isolation  Linearization.
WIRELESS CHARGING Presented by: K.MAHESH (08T81A1236)
3 Fiber-Optic Cable Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives  Explain how fiber-optic cable.
Islamic Azad University, Bandar Gaz Ahmad Bahrami Subject article : Optical fiber Fall 89.
A MR Compatible Pressure Transducer with Data Acquisition Software Program Mark Crowe Viral Patel Advisor: Dr. David Pickens.
Biology and Behavior Neuroscience  Scientific study of the brain and of the links between brain activity and behavior.
Continuous Passive Motion Hand Rehabilitation. Design Team Project Sponsors: Bert Lariscy, Vanderbilt University EE graduate Crystal Bates, Occupational.
Indexing and Retrieval of Dyanamic Brain Images: Communication Within the Human Brain Author: Arnav Sheth Supervisor: Dr. Lawrence Shepp, Statistics Department,
Lecture (11): Water Distribution Systems
A System View of Optical Fiber Communication
Price Sheet Review.
Introduction to Computers
A System View of Optical Fiber Communication prt.2
HEMODYNAMIC SIMULATOR II P09026
Satish Pradhan Dnyanasadhana college, Thane
Instrument to Detect Thromboemboli in Blood
January 21, 2004 Students Advisors Jose Alvarado Ben Huh
Continuous Passive Motion Hand Rehabilitation
COMMUNICATION ENG. PROF. A.M.ALLAM
Fibre Optic Transmission
Electroencephalogram (EEG)
Chapter 5 – Distributed Elements
Multi-Channel Gustometer
Presentation transcript:

Non-Invasive Blood Pressure Device for Use in fMRI Imaging Applications November 18, 2004 Jose Alvarado Ben Huh Sanjeet Rangarajan Dr. André Diedrich Dr. John Gore Dr. Richard Shiavi StudentsAdvisors

Background Functional Magnetic-Resonance Imaging (fMRI) has recently allowed novel insights into the function of individual brain sites. Patients with baroreflex failure have extremely labile blood pressure due to loss of buffering function of blood pressure control. Higher centers of the brain stem and cortical structures may have potentiating effects on changes in autonomic outflow. Measuring blood pressure continuously during fMRI procedures could provide numerous benefits to the study of autonomic disorders.

The Problem Current commercial devices such as the FINAPRES, FINOMETER, and PORTAPRES are able to continuously measure blood pressure but not in the presence of magnetic fields. The electrical sensor system for the finger cuff as well as the pneumatic pump interfere with the highly sensitive fMRI magnet.

Market Analysis Use for only in research and hospital settings. Large market potential because of applications in other MRI and fMRI studies. An optical continuous non-invasive blood pressure measuring device could be used in conjunction with electromagnetical trackers which are used in image guided surgery. Profit will come from selling the design of the fMRI compatible finger cuff to pre-existing companies that manufacture the cuffs. Perhaps too specific of an item to be able to market the device independently and for this reason it could be a better to sell the design to a current company.

Our Solution Retrofit finger cuff blood pressure devices to use optical transmission techniques instead of electrical transmission techniques. Replace electrical cables and sensors with optical components: Fit cuff with an optical cable terminator. Develop an fiber-optic interface compatible with existing commercially available electrical systems. Design fMRI compatible shielding. Extend length between cuff and electrical components without losing pneumatic function.

Estimated Design Cost

Completed Tasks We have tested what we expected to be the first limiting factor, how far the pneumatic pump can be extended from the patient and still ensure proper cuff inflation. Prediction: The small radius of the air tubes used with the FINAPRES creates a large resistance to flow with increasing tube length. Limited pump pressure leads to insufficient air supply to the cuff. Experimental Result: Using tubing of the same diameter as the manufacturer, the maximum extension length was found to be around 10 ft.

Current Work Currently we are testing tubing of varying radii and stiffness to determine the maximum length of extension while maintaining accurate blood pressure readings. We are consulting with Dr. Gore about the possibility of shielding the electrical components in the case that an ideal extension length is unattainable using the manufacturer’s pneumatic pump.

Future Work Contact Dr. Gore at the Vanderbilt University Institute for Imaging Science to become acclimated with the facility and learn about typical fMRI processes. The Imaging Institute’s fMRI scanner will eventually be used to test our design. Dr. Duco Jansen will be contacted to ask for his expertise on selecting appropriate fiber-optic components. Use experimental parameters to predict the necessary wavelength LED to ensure a proper signal and the photodetector needed to properly capture the transmitted light.

Questions Questions?