University of Baghdad College of engineering Ele. & Com. Dept. 3 rd Year Matlab Report of By Ahmed Alaa Part I Part II.

Slides:



Advertisements
Similar presentations
Chapter 3 Feedback Amplifiers
Advertisements

CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
Design with Root Locus Lecture 9.
Feedback Control Systems Dr. Basil Hamed Electrical & Computer Engineering Islamic University of Gaza.
Lect.7 Steady State Error Basil Hamed
CHE 185 – PROCESS CONTROL AND DYNAMICS
Voltage-Series Feedback
CHE 185 – PROCESS CONTROL AND DYNAMICS
Oscillator principle Oscillators are circuits that generate periodic signals. An oscillator converts DC power from power supply to AC signals power spontaneously.
1 Fifth Lecture Dynamic Characteristics of Measurement System (Reference: Chapter 5, Mechanical Measurements, 5th Edition, Bechwith, Marangoni, and Lienhard,
RF & Microwave Engineering
Transient and steady state response (cont.)
Feedback Control Systems
Review last lectures.
ME 270 Final Project Presentation Operational Amplifiers.
Chapter 8 - Feedback 1 - Desensitize The Gain 2 - Reduce Nonlinear Distortions 3 - Reduce The Effect of Noise 4 – Control The Input And Output Impedances.
Combined State Feedback Controller and Observer
A Differentiator Circuit.  All of the diagrams use a uA741 op amp. ◦ You are to construct your circuits using an LM 356 op amp.  There is a statement.
Topic 28: Direct Sensing 28.1 Sensing devices
Basic feedback theory and Oscillators by D. V
Inverting Amplifier. Introduction An inverting amplifier is a type of electrical circuit that reverses the flow of current passing through it. This reversal.
Differential Amplifier
Proportional control Consider forward path gain A Feedback and Control If the size of the loop gain is large, that is if |A  >> 1, then or.
Low Level Control. Control System Components The main components of a control system are The plant, or the process that is being controlled The controller,
Feedback Control system
PID CONTROLLERS By Harshal Inamdar.
DC Motor Speed Modeling in Simulink
Chapter 6 Analysis of Feedback Control Systems Prof. Shi-Shang Jang Chemical Engineering Department National Tsing-Hua University Hsin Chu, Taiwan June,
Frequency Response Analysis and Stability
Modern Control System EKT 308 Steady-State and Stability.
Features of PID Controllers
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Modern Control System EKT 308
Chapter 3 Feedback Circuits BY: PN NORIZAN BINTI MOHAMED NAWAWI EKT 214 – Analog Electronic CIRCUIT II.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
1 Steady-State Error M. Sami Fadali Professor of Electrical Engineering University of Nevada.
Intelligent Robot Lab Pusan National University Intelligent Robot Lab Chapter 7. Forced Response Errors Pusan National University Intelligent Robot Laboratory.
Control Systems Lect.3 Steady State Error Basil Hamed.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
 The differentiator or differentiating amplifier is as shown in figure.  This circuit will perform the mathematical operation of differentiation.
Feedback Amplifier By : Mohanish R. Chaubal –
CONTROL SYSTEM ENGINEERING
FEEDBACK CIRCUITS CLASSIFICATION OF AMPLIFIER CONCEPT OF FEEDBACK
E212 – Analog Electronic II
Automatic Control Theory CSE 322
Control Systems EE 4314 Lecture 12 March 17, 2015
Modern Control Systems EKT 308
Chapter 7 The Root Locus Method The root-locus method is a powerful tool for designing and analyzing feedback control systems The Root Locus Concept The.
Digital and Non-Linear Control
Automatic Control Theory CSE 322
International Africa University Faculty of Engineering Eight Semester
Feedback Amplifiers.
Basic Design of PID Controller
Chapter 9 Design via Root Locus <<<4.1>>>
Steady-State Errors System & Control Engineering Lab.
Features of PID Controllers
Root Loci Analysis (3): Root Locus Approach to Control System Design
UNIT-II TIME RESPONSE ANALYSIS
SIGNAL FLOW GRAPH.
Compensators.
Frequency Response Techniques
UNIVERSITI MALAYSIA PERLIS SCHOOL OF ELECTRICAL SYSTEM ENGINEERING
7-4 Control System Design by Frequency Response Approach
B.Tech – II – ECE – II SEMESTER ACE ENGINEERING COLLEGE
PID Controller Design and
INTRODUCTION TO CONTROL SYSTEMS
Frequency Response Techniques
Exercise 1 For the unit step response shown in the following figure, find the transfer function of the system. Also find rise time and settling time. Solution.
By: Nafees Ahamad, AP, EECE, Dept. DIT University, Dehradun
By: Nafees Ahamad, AP, EECE, Dept. DIT University, Dehradun
Presentation transcript:

University of Baghdad College of engineering Ele. & Com. Dept. 3 rd Year Matlab Report of By Ahmed Alaa Part I Part II

Objectives The general characteristics of a closed loop system provided by speed and position control for an electric motor using MATLAB Procedure PART ONE: POSITION CONTROL SYSTEM 1.Run the MATLAB program on a PC 2.Give the simulink for the block diagram shown in fig.4 3.For the gain KA=3 set the feedback gain K1 to: 0,0.2,0.4,0.5,0.6,1,3,5,10 4.Draw the output response with the step input signal for each case 5.From the output response calculate the following time constants values (Delay time td,tr,tp,ts, and the maximum %OS (Mp) (only for cases that k=0 up to 0.6) PART TWO: SPEED CONTROL SYSTEM 1.Give the simulink for the block diagram shown in fig.5 2.Set the step i/p of a final value of 1 and step time of 0 with k=10 ; kg=1 3.Draw the o/p response with step i/p signal 4.From the o/p response calculate the following time constants values (Delay time td,ts,tr,Mp,tp) 5.Repeat 3 and 4 for the following values of a step input final values (2,3,4,5,6,7,8,9,10) Page 1

Page 2 Discussion 1.What is the benefits of using feedback paths in control system, is it good to increase the feedback paths in these systems ? Why ? 2.Derive the overall transfer function of the position control CLS from the basic equations. the most important advantages is available when negative feedback used increasing stability, bandwidth and for +ve feedback ; an oscillation is probably occurs when BA=1 if we increased the number of feedback paths, a great stability is composed with this case but with an increasing noise i.e if the number of passive elements is increased in a circuit a noise will happen For a CLS: G(s)=A/1+BA A is OLTF for fig 2-b A=Km/s(1+Ts) KA is the preamplifier gain Om is the gear unit gain At=KA(A)(Om) At=KAKmOm/s(1+Ts) G(s)=KAKmOm/s(1+Ts)+KAKmOm

Page 3 3.What is the effect of changing the values of KA and K1 on the response of the position control system? 4.Reason out why the error decreases as the system gain increases in speed control system Increasing k1 will increase Ts i.e the time is taken by system to reach its steady state is increased ; if k1=0 i.e f.b path removed. An oscillation is occurred before the system reaches steady state ; increasing KA will increase the Mp (max. %OS) Increasing KA if K1 exists make no difference For KA=1 ; K1=0 For KA=3 ; K1=0 For KA=10 ; K1=1 System gain k is directly proportional with error constant i.e Kv Kv=lim skG(s) as s approaches 0 And error(ramp)=1/Kv Hence the error will decrease if k increased

Page 4 5.Compare between the theoretical and practical results for both systems and comment on your results. For step II Ts=4/zWn ; z=0.5 and Wn=1 Ts=8 sec [equal to the practical] from these experiments we found that k of feedforward of a system with unity one path feedback will affects the Mp.. Oscillation is increased when k is increased ; the other k i.e of feedback is affects the o/p magnitude. Unity case is preferred for control systems. Adding another path of feedback will increase the stability. Adding with a value of k ( of the feedback) will decrease Ts.( for procedure step 1) Mp,Ts,Tp and Tr remains constant even if we increased the final value of a step i/p