Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual.

Slides:



Advertisements
Similar presentations
Good Practices of Fluorescence Spectroscopy
Advertisements

LIDAR TECHNOLOGIES FOR EARTH OBSERVATION January 2008 Dr Kim Hampton Lidar Technologies Ltd.
DLC in optics Student talk Saara Hirvonen
SVOM MXT Lobster Eye Telescope Breadboard Model Testing Preliminary Results Dick Willingale Adrian Martindale, Jim Pearson, Charly Feldman, Julian Osborne.
1 ATST Imager and Slit Viewer Optics Ming Liang. 2 Optical layout of the telescope, relay optics, beam reducer and imager. Optical Layouts.
The world leader in serving science Reflection Techniques.
OL 750 Diffuse Spectral Reflectance Measurement System
A Narrow Field Lobster Eye Telescope Dick Willingale – AXRO December 2014 A Narrow Field Lobster Eye Telescope (for SVOM and similar) Dick Willingale Adrian.
What disperses radiation into component wavelengths?
Spectrum Identification & Artifacts Peak Identification.
K-Space Associates, Inc. kSA BandiT: Band-edge Thermometry.
Light Source: Globar Silicon Carbide Rod (5mm diameter, 50 mm long) Heated electrically to 1300 – 1500 K Positive temperature coefficient of resistance.
OL 750 Measurement Systems
Introduction to Remote Sensing The Electromagnetic (EM) Spectrum.
Reflection & Refraction of Light Reflection: specular (mirror) vs diffuse angle of incidence = angle of reflection Refraction: Snell’s Law n 1 sin 
Infrared Radiation 780 nm m Near, Mid and Far
Energy interactions in the atmosphere
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Integration of sensors for photogrammetry and remote sensing 8 th semester, MS 2005.
Infinity Corrected Microscope Optics
NON DESTRUCTIVE CHEMICAL ANALYSIS
Lecture 3 INFRARED SPECTROMETRY
Astronomical Spectroscopy
Photography Basics. The Process The Exposure - Camera and Lens Developing - Dark Room or PS… Printing – Darkroom or InkJet.
Satellite basics Estelle de Coning South African Weather Service
Copyright © 2002 Terabeam Corporation. All rights reserved. 1 Challenges Solar Interference Direct or reflected sunlight can saturate receivers or tracking.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
A short depth of field is focused in the foreground, but is out of focus in the immediate background. There is no middle-ground. The aperture is wide.
Chapter 34 The Wave Nature of Light; Interference
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
SCM 330 Ocean Discovery through Technology Area F GE.
EUV Maskless Lithography J. Vac. Sci. Technol. B 30, (2012); 9/25/20121K. Johnson
Video Camera Lens Fundamentals Carlo Beltrano
BASIC CONCEPT reflecting layer glass capillary wall CENTER LINE optically active layers polyimide.
Stability Requirements for Superconducting Wiggler Beamlines
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Polarization Modulation with PEM for CD
The Microscope and Forensic Identification. Magnification of Images A microscope is an optical instrument that uses a lens or a combination of lenses.
Infrared Microspectroscopy
Copyright © 2009 Pearson Education, Inc. Chapter 34 The Wave Nature of Light; Interference.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Reaction Monitoring with ReactionView ® and ReactionProbe™ In-situ contamination and surface analysis with SpotView and SpotView-SL © Remspec Corp
Infrared Microspectroscopy A training guide for using light microscopy and infrared spectroscopy to analyze materials.
Electro-optical systems Sensor Resolution
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Index-matching effect. Matching the index of refraction of the bead with the solution.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Solid-state Laser Crystal and Device Laboratory Yen-Yin Li Speaker : Yen-Yin Li Adviser : Sheng-Lung Huang Topic Report Graduate Institute of Photonics.
Infrared Spectroscopy: Comparison of Transmission and ATR Techniques Matt Herring Lewis University.
ATTENUATED TOTAL REFLECTION SPECTROSCOPY Outline Introduction to ATR technology Evanescent Waves Crystal Composition Data Collection Advantages & Disadvantages.
LAB. S4 Identification of Drugs Using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FT-IR Spectroscopy)
Research stoichiometric of heterogeneity of lithium niobate crystals by IR spectroscopy Paranin V.D., Pantelei E.
Optical Characterization Techniques
OPTICAL SOURCE : Light Emitting Diodes (LEDs)
Picture Basics Disclaimer: I am NOT a camera guy
Polarization Modulation with PEM for CD
Hyperspectral Remote Sensing
NANO 230 Micro/NanoFabrication
Instrument Considerations
Infrared Spectroscopy
OL 750 Measurement Systems
A Very Brief Introduction to Infrared Spectroscopy
Infrared Sampling Methods
Hyperspectral Remote Sensing
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Emissivity of Different Minerals: Example
What if you use a capillary, small specimen or transmission technique
Presentation transcript:

Centaurµs Centaurus Technical Review

Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual focus Manual Full Field (Glass) Aperture Simultaneous View and IR Integrated Video Integrated Contact alert

Centaurµs Centaurus Options ATR –ZnSe, Si, Ge crystals Motorized Stage Manual Stage Auto Focus Binocular Viewer MCT Detectors –Narrow, Mid, or Wide band

Centaurµs Centaurus Specifications 10x optics –N.A. = 0.71 Video and Field of View matched – 600 x 450um IR Spot size 200um Working distance –9mm Angle of Incidence – 44°- 19° Magnification 100x

Centaurµs Signal to Noise 2 minute collect at a resolution of 4 cm-1, triangular apodization, 1.0 mm square aperture with MCT A mid-band detector on Nexus Transmission mean average.028peak to peak –Signal to noise ratio3000 to 1 Reflection mean average.065 peak to peak –Signal to noise ratio1500 to 1

Centaurµs Field of View is 600 x 450 micrometers Matches the binocular viewer

Centaurµs 12 um Kevlar™ fiber

Centaurµs Superior performance of Targeting™ in a Single Aperturing System 12 µm fiber 12 x 40 µm aperture Targeting Vs. single aperture after the sample

Centaurµs Dark Mirror Coating Eliminates HeNe Blocks HeNe Reflects IR Radiation 98% of Gold

Centaurµs Transmission Multi layered laminate 4 layers 30 to 60 um layers

Centaurµs Transmission Nylon Fiber

Centaurµs Palm Oil

Centaurµs Reflection External Reflection –Reflection absorption –Specular Reflection Internal reflection (ATR) –Znse, Ge, and Si

Centaurµs Specular Reflection Apoxy Resin

Centaurµs Reflection Absorbtion High signal to noise 30 second acquisition time

Centaurµs ATR ZnSe, Ge, Si Energy throughput comparable to InspectIR Frequency test using Toluene No spectral artifacts

Centaurµs ATR Frequency/Artifacts Test

Centaurµs ZnSe ATR Ink on Business Card High signal to noise Equivalent Performance to InspectIR Use with or without aperture

Centaurµs Si ATR Crystal

Centaurµs GE ATR Crystal Shallow depth of penetration Good for carbon or filled samples